Advertisement for orthosearch.org.uk
Results 1 - 20 of 22
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 120 - 120
1 Feb 2020
Gonzalez FQ Fattori A Lipman J Negro ND Brial C Figgie M Hotchkiss R Pressacco M Wright T
Full Access

Introduction. The interaction between the mobile components of total elbow replacements (TER) provides additional constraint to the elbow motion. Semi-constrained TER depend on a mechanical linkage to avoid dislocation and have greater constraint than unconstrained TER that rely primarily in soft tissue for joint stability. Greater constraint increases the load transfer to the implant interfaces and the stresses in the polyethylene components. Both of these phenomena are detrimental to the longevity of TER, as they may result in implant loosening and increased damage to the polyethylene components, respectively[1]. The objective of this work was to compare the constraint profile in varus-valgus and internal-external rotation and the polyethylene stresses under loads from a common daily activity between two semi-constrained TER, Coonrad/Morrey (Zimmer-Biomet) and Discovery® (DJO), and an unconstrained TER, TEMA (LimaCorporate). Methods. We developed finite element (FE) models of the three TER mechanisms. To reduce computational cost, we did not include the humeral and ulnar stems. Materials were linear-elastic for the metallic components (E. Ti6Al4V. =114.3 GPa, E. CoCr. =210 GPa, v=0.33) and linear elastic-plastic for the polyethylene components (E=618 MPa, v=0.46; S. Y. =22 MPa; S. U. =230.6 MPa; ε. U. =1.5 mm/mm). The models were meshed with linear tetrahedral elements of sizes 0.4–0.6 mm. We assumed a friction coefficient of 0.02 between metal and polyethylene. In all simulations, the ulnar component was fixed and the humeral component loaded. We computed the constraint profiles in full extension by simulating each mechanism from 8° varus to 8° valgus and from 8° internal to 8° external rotation. All other degrees-of-freedom except for flexion extension were unconstrained. Then, we identified the instant during feeding that generated the highest moments at the elbow[2], and we applied the joint forces and moments to each TER to evaluate the stresses in the polyethylene. To validate the FE results, we experimentally evaluated the constraint of the design with highest polyethylene stresses in pure internal-external rotation and compared the results against those from a FE model that reproduced the experimental setup (Fig.1-a). Results. For each design, the constraint profiles in varus-valgus (Fig.2-a) were similar to internal-external rotation (Fig.2-b). All designs showed a lax zone in which the mechanisms rotated freely and an engagement zone in which the mobile components contacted, resulting in load transfer. The laxity of the Coonrad/Morrey and the Discovery® was similar and lower than that of the TEMA. After engagement, the stiffness of the TEMA was less than that of the Discovery® and the Coonrad/Morrey. The TEMA showed the lowest polyethylene stresses of all three designs under demanding loads during feeding. Only Discovery® and Coonrad/Morrey had zones reaching permanent deformation (Fig.3). For the Coonrad/Morrey, with the highest polyethylene stresses, the experimental and computational constraint profiles were similar (Fig.1-b). Discussion. The TEMA unconstrained design transferred less moment than semi-constrained designs, reducing the burden on the implant interfaces. Moreover, the TEMA design had lower stresses in the polyethylene components due to the combination of less constraint and a lack of sharp edges on the articular surfaces. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 273 - 273
1 Jul 2014
Alizadehkhaiyat O Vishwanathan K Frostick S
Full Access

Summary Statement. Discovery system produced effective functional improvement in both primary and revision total elbow replacement. The incidence of major complications was in an acceptable range. Introduction. The search for the ideal elbow prosthesis continues as instability and loosening remain the prime reasons for total elbow replacement (TER) failure. The Discovery Elbow System (Biomet) is one of the latest generations of linked prosthesis and has been used in UK since 2003. We report outcome of TER using this system. Methods. A total of 100 TERs (75 primary, 25 revisions) were performed between 2003 and 2010. The main primary underlying pathologies for TER were advanced rheumatoid arthritis (N=58), osteoarthritis (N=35), acute fractures (N=7). There were 60 female and 40 male patients with an average age of 62 years. The outcome assessment included pain, patient satisfaction, Liverpool Elbow Score (LES), range of movement, and imaging during a mean follow-up period of 48.5 months. Major complications are also reported. Results. For the whole patient group (primary + revision), the LES was significantly (p<0.001) improved from 3.79+/−1.71 to 6.36+/−1.85There were significant improvements in elbow flexion from 100°+/−24 to 118°+17, supination from 38°+/−26 to 50°+/−25 and pronation from 48°+/−22 to 61°+/−21. Mean improvement in flexion-extension and pronation-supination arc was 20° and 25°, respectively. 64% of cases were completely pain-free and at the final follow-up (compared to 7% preoperatively). Only 6% of patients scored “Not Satisfied” at the final follow-up. LES improvement was significantly higher in the primary TER compared to revision TER (p<0.05). Imaging reviewed for 60 cases showed loosening in 4% of patients. Other main complications included deep infection (N=2), ulnar neuropathy (N=3), pre-prosthetic fracture (N=2), and prosthetic failure (N=1). Discussion. TER using the Discovery Elbow System is an effective arthroplasty in terms of functional improvement, pain relief and range of motion in both primary and revision patients. TER resulted in no/mild pain in 78% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 20° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSBIII (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 25° in pronation-supination arc in our series is also comparable to that of 21–28° reported the Coonrad-Morrey and 27–33° for Discovery prostheses. An infection rate of 2% is lower than several other reports for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy (3%) was lower compared to GSBIII TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 146 - 146
1 Mar 2017
Kia DS Willing R
Full Access

As a treatment for end-stage elbow joint arthritis, total elbow replacement (TER) results in joint motions similar to the intact joint; however, bearing wear, excessive deformations and/or early fracture may necessitate early revision of failed implant components. Compared to hips, knees and shoulders, very little research has been focused on the evaluation of the outcomes of TER, possible failure mechanisms and the development of optimal designs. The current study aims to develop computational models of TER implants in order to analyze implant behaviour; considering contact stresses, plastic deformations and damage progression. A geometrical model of a TER assembly was developed based on measurements from a Coonrad-Morrey TER implant (Zimmer, Inc., Warsaw, IN). Ultra high molecular weight polyethylene (UHMWPE) nonlinear elasto-plastic material properties were assigned to the humeral and ulnar bushings. A frictional penalty contact formulation with a coefficient of friction of 0.04 was defined between all of the surfaces of the model to take into account every possible interaction between different implant components in vivo. The loading scenario applied to the model includes a flexion-extension motion, a joint force reaction with variable magnitude and direction and a time varying varus-valgus (VV) moment with a maximum magnitude of 13 N.m, simulating a chair-rise scenario as an extreme loading condition. An explicit dynamic finite element solver was used (ABAQUS Explicit, Dassault Systèmes, Vélizy-Villacoublay, France), due to improved capabilities when performing large deformation analyses. Model results were compared directly with corresponding experimental data. Experimental wear tests were performed on the abovementioned implants using a VIVO (AMTI, Watertown, MA) six degree-of-freedom (6-DOF) joint motion simulator apparatus. The worn TER bushings were scanned after the test using micro computed tomography (µCT) imaging techniques, and reconstructed as 3D models. Comparisons were made based on the sites of damage and deformed geometries between the numerical results and experimental test data. In addition to that, parametric geometrical models were developed using worn geometry of the retrievals in order to account for primary wear and deformations while simulating long-term contact stress and secondary damage progression on the bushings (Fig. 1). Contact pressure distributions on the humeral and ulnar bushings correlate with the sites of damage as represented by the µCT data and gross observation of clinical retrievals. Furthermore, deformation patterns and kinematics of the components are in good agreement with the experimental results (Fig.2). Excessive plastic deformations are evident in both the numerical and the experimental results close to the regions with high contact pressures. Simulating parametric initially-worn geometries results in the formation of secondary damage zones, as well as redistribution of contact stresses and contact locations (Fig. 3). The results demonstrate UHMWPE bushing damage due to different loading protocols. Numerical results demonstrate strong agreement with experimental data based on the location of deformation and creep on bushings and exhibit promising capabilities for predicting the damage and failure mechanisms of TER implants. For figures/tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 2 - 2
1 Mar 2013
Alizadehkhaiyat O Vishwanathan K Frostick S Al Mandhari A
Full Access

Background. The quest for the perfectly designed elbow prosthesis continues as instability and loosening remain the foremost reasons for the failure of total elbow replacement (TER). The Discovery® Elbow System (Biomet, UK) (Figure 1), which has been used in UK since 2003, is one of the latest generations of linked prosthesis. This system was designed to decrease polyethylene-bushing wear, improve anatomic stem design, restore elbow joint biomechanics, and produce a hinge that could be easily revised. This report describes the short term outcome of TER using the Discovery® Elbow System. Patients and Methods. A total of 60 TERs including 48 primary and 12 revisions were performed between 2003 and 2008. Patients included 21 males (37%) and 36 females (63%) with a mean age of 63 years. The indications for primary TER were advanced rheumatoid arthritis (n=19), osteoarthritis (n=16), post traumatic osteoarthritis (n=9), acute fractures (n=3), and haemophilic arthropathy (n=1). The outcome was assessed using pain score, Liverpool Elbow Score (LES), and range of movement during a mean follow-up of 26 months. Associated complications were documented. Radiological assessment included evaluation for loosening, instability and periprosthetic fractures. Results. The mean LES was significantly (p<0.001) improved from 3.8 (±1) pre-operatively to 6.9 (±2) at the final follow- up. Significant improvements were noted in elbow flexion from 100° (±22) to 120° (±15), supination from 41° (±28) to 65° (±20) and pronation from 52° (±22) to 72° (±18). There was no significant change in elbow extension. Mean improvement in flexion-extension and pronation-supination arc was 22° and 44°, respectively. 46 cases (77%) were completely pain-free at the final follow-up. The main complications included deep infection (4 cases – treated with staged revision TER), postoperative ulnar neuropathy (3 cases–treated with decompression), intra-operative fractures of medial condyle (3 cases – treated non-operatively with brace), and elbow haemarthrosis (1 case). Discussion. TER with Discovery® Elbow System resulted in either no pain or mild pain in 87% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 22° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSB III (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 44° in pronation-supination arc in our series is also comparable to that of 31–67° reported for GSB III and higher than the Coonrad-Morrey prosthesis (21–28°). In terms of complications, an infection rate of 6.7% is consistent with those reported for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy was lower compared to GSB III TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%). While the survival of Discovery TER was 93%, the survival of GSB III (5–6 years) and Coonrad-Morrey (5 years) has been reported as 71–85% and 72–90%. The results indicate that Discovery® Elbow System is an effective device for total elbow arthroplasty in terms of functional improvement, pain relief and range of motion at short-term follow-up


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 76 - 76
1 Aug 2013
Vrettos B Vochteloo A Roche S
Full Access

Purpose of study:. Total elbow replacement (TER) is one of the surgical options for treatment of severe haemophilic arthropathy of the elbow. There are only a few small series described in the literature. The goal of our study was to evaluate our cases and add these data to the known literature. Methods:. A retrospective analysis of a series of 8 TER's (5 patients) was performed. Patients were seen in clinic and evaluated by physical examination, a VAS score for pain, the Mayo Elbow Performance Score (MEPS, 100 points=excellent) and X-rays of the affected elbow. Mean follow-up was 91 (4–236) months, and 103 months when we excluded a patient with only 4 months follow-up. Primary diagnosis was Hemophilia type A in 4 and von Willebrand disease in 1 patient. 2 patients were positive for Hepatitis C and 3 for HIV. Mean age at primary surgery was 46.7 (31.8–63.1) years. Results:. The mean VAS score for pain improved from 7.9 to 0.5 and the mean Mayo Elbow Performance Score from 36 to 93. The arc for flexion/extension improved from 68° to 91° and from to 75° to 153° for pro- and supination. Revision surgery was performed in 3 out of 8 TER's; 1 because of loosening of the humeral component (18.7 years postop), 1 for loosening of the ulnar component (9.9 years postoperatively) and 1 due to a late deep infection, 4 years postoperatively. The last case was treated with an excision arthroplasty, the others with a revision. No replacement currently shows signs of loosening. Conclusion:. This is a small retrospective study, as are the other studies on TER in haemophilic patients. It demonstrated excellent clinical outcome and an acceptable survival rate of a TER, with a mean follow-up of 7.6 years even in this young patient population


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 9 - 9
1 Mar 2005
Vrettos B Roche S
Full Access

Of 81 elbow replacements performed over a seven-year period, 11 were total elbow revision (TER) procedures, which were done on two men and nine women with a mean age of 61 years (40 to 70). Seven of the patients had rheumatoid arthritis, three had post-traumatic osteoarthritis and one had haemophilia. The reason for revision was aseptic loosening in eight patients and aseptic loosening with fracture in the other three. The prostheses revised were the Souter in eight patients, the Kudo in one, the GSB I in one and the Dee in one. In revision TER, one long stem Souter prosthesis was used, two Pretoria, one GSB 3 and seven Morrey. The mean time from primary to revision TER was 10 years (2 to 31). At a mean follow-up of 30 months (6 to 48), all except one patient were pain-free and the arc of flexion had increased by 30°. Complications included one dislocation, one radial nerve palsy, which recovered after six months, and one aseptic loosening. There were no cases of sepsis. Revision TER is a technically demanding procedure with a high risk of complications. In this series patient satisfaction was high. Our policy is to use a hinged prosthesis, preferably the Morrey, in revision TER


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 5 - 5
1 Dec 2014
Williams H Madhusudhan T Sinha A
Full Access

TER is a viable surgical option in patients with advanced RA with painful stiff elbows. We retrospectively analysed 22 TER performed in 21 patients over a 12 year period by a single surgeon, with a mean follow up of 64 months (10–145). Disability of the arm, shoulder and hand (DASH) scores were performed pre-operatively and post-operatively in patients through postal questionnaires. The mean age was 59.1 years (32–78). There were 12 women and 9 men. The mean pre-operative DASH score was 72.3 (45.0–91.7) and post-operatively improved to 46.8 (21.7–94.2). Complications included infection, peri-operative fracture, peri-prosthetic fracture and aseptic loosening. There were 6 revisions performed, 2 for peri-prosthetic fracture, 2 for infection, 1 for intra-operative fracture and 1 for symptomatic aseptic loosening. Four patients had died due to unrelated causes. The 10 year survival rate with symptomatic aseptic loosening as the end point was 93% and revisions for all reasons was 69%. Follow up radiographs (in those without revision) were reviewed and 10 had satisfactory positioning of the prosthesis, 5 had loosening of the humeral or radial component and 1 had inadequate cement mantle but was clinically asymptomatic. TER is a rewarding procedure in with advanced RA. Our results are comparable to other published studies


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 32 - 32
1 Dec 2014
Williams H Madhusudhan T Sinha A
Full Access

We retrospectively analysed a single surgeon series of 22 TER in 21 patients over a 12 year period. The mean age and follow up was 59.1 years and 64 months respectively. DASH scores assessed pre and post op confirmed a significant improvement. Complications included infection, intra-operative fracture, peri-prosthetic fracture and aseptic loosening. 6 revisions were performed for various reasons.4 patients had died due to unrelated causes. The 10 year survival rate with symptomatic aseptic loosening as the end point was 93%. 5 patients had radiological loosening but were clinically asymptomatic. TER is a rewarding procedure in with advanced RA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 85 - 85
1 May 2012
Abbas G Chuter G Williams J
Full Access

Introduction. Primary Total Elbow Replacement (TER) is gaining popularity as a primary treatment option for osteoporotic fractures of the elbow, particularly in patients with low demand. The aim of this study was to assess the clinical and functional efficacy of TER as a primary treatment for comminuted distal humerus fractures in the elderly. Methods. We retrospectively reviewed twenty-three patients (22 females and 1 male) who were treated with primary total elbow replacement for complex, intra-articular fractures of the distal humerus in the elderly between March 2000 and January 2010. The average age of the patients was seventy-five years (ranging from 66 to 94 years). Postoperative elbow function was assessed using the Mayo Elbow Performance Score. The radiological assessment was performed using antero-posterior and lateral radiographs done at follow-up appointments. Results. The average duration of follow up was 6 years. Overall, the mean Mayo elbow performance score was 93 points out of 100. The arc of flexion averaged at 94.3degrees. One patient developed blisters at her arm postoperatively but resolved with dressings. Two patients (8.6%) had mild pain at two years post surgery but there was no evidence of implant loosening or evidence of infection. One patient developed superficial infection which was treated with antibiotics. Nineteen (82%) of the twenty-three elbows had neither a complication nor further surgery from the time of TER to the recent follow up. Conclusions. Our review suggests that total elbow replacement as a primary treatment for comminuted distal humerus fractures in the elderly can give good to excellent results both in the short and the long term basis. When osteosynthesis is not a feasible option, especially in older patients who place lower demands on the joint, total elbow replacement can be considered a the primary treatment


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 196 - 196
1 Jul 2002
Pooley J Singh R
Full Access

An inclusive classification system is required if valid comparisons are to be made between the various types of implants used for total elbow replacement (TER). The aim of the study was to consider the characteristics of the prostheses developed for TER in order to classify these into clearly defined categories. A descriptive term such as ‘surface replacement’ is unhelpful as this would embrace every design.A classification based solely upon degree of resistance to movement –‘constraint’-is untenable. ‘Constrained’ or ‘fully constrained’ accurately describes a uni-axial hinge, but the term ‘semi-constrained’ defies description. The terms ‘unconstrained’ or ‘non-constrained’ applied to a joint defy understanding. If articulating surfaces offer no resistance to movement as these terms imply, then there can be no contact between those articulating surfaces. A definable, inclusive classification can be formulated by considering the mechanical characteristics of the articulating surfaces of each design. Every design of TER can be classified into one of two broad groups, Linked or Unlinked. We define linked components as those offering resistance to distraction which includes snap-fit designs. Each of these two groups can then be sub-divided into ‘congruous’ or ‘non-congruous’ designs depending upon the shape of the articulating surfaces. This classification can therefore be summarised as: Linked Congruous – original uni-axial hinge, snap fit designs; Linked Non-congruous – ‘sloppy hinge’; Unlinked Congruous – eg. Capitellocondylar,Souter/ Strathclyde,Roper-Tuke etc; and Unlinked Non-congruous – Kudo, iBP


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 190 - 190
1 Jul 2002
Garcia J Mykula R Stanley D
Full Access

Cobb and Morrey (1997) reported the use of Total Elbow Replacement (TER) for patients with distal humerus fractures. In this paper, 48% of the patients had a previous history of inflammatory arthropathy. Our aim was to determine the role of TER as treatment for complex distal humeral fractures in elderly patients with no previous history of inflammatory arthropathy. These patients have greater functional demands. The complexity of the original injury was graded according to the AO Mullers’ classification of supracondylar humeral fractures. All patients were reviewed clinically and radiographically. Their daily activities and general post-operative quality of life was estimated with the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire. The Mayo elbow performance score was used for functional evaluation. Implant survivorship was assessed. Fourteen patients (11 female and three male) underwent a Coonrad-Morrey TER via a standard posterior approach for humeral fractures. Their mean age was 73 years (range 61–84 years) at the time of injury. Ten patients had suffered a C3 injury, two a B3 and two an A3 according to the AO classification. The mean time to surgery after their injury was 8 days (range: 1–21 days). Complications: one myocardial infarct and one superficial wound infection. Mean time to follow-up was three years and two months (range: 9–66 months). Nine (64%) reported no pain, four (29%) had mild pain with activity and one had mild pain at rest. The mean arc of extension-flexion movement was 24°–125°. Supination: mean = 90° (range: 70°–100°). Pronation: mean = 70° (range: 50°–110°). No elbow was unstable. The mean DASH score was 22.6 (range: 0.92–63.3). Zero reflects no disability, 100 reflects most severe disability. The mean Mayo elbow performance score was 90 (range: 80–100). X-rays revealed that all implants were well fixed with no evidence of loosening. One patient had severe hypertrophic bone


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 333 - 333
1 Mar 2004
Havelin L Espehaug B Furnes O Lie S Vollset S Enges¾ter L
Full Access

Aims: The mid- and long-term results of uncemented cups are uncertain. The aim of this study was to assess their results and to compare them with the most common cemented cup, the Charnley. Material and methods: In the study we included only patients under the age of 60 that had been operated with one of the 10 most common uncemented cup brands or the Charnley cup. Only brands that had been in use for at least 6 years were included. There were only minor differences among the brands concerning age, gender and diagnosis. Survival percentages were calculated with the Kaplan-Meier method. Results: With all cup revisions (change of cup or polyethylene liner) as end-point, the overall 5 year survival probability was 97% (95% CI: 96.3 97.3) which decreased to 86% (95% CI: 84.4 Ð 87.5) at 10 years. The 10 years survival varied from 74% for the Atoll cup to 88% for the Optiþx and the Harris-Galante cup, whereas for the cemented Charnley cup the 10 years survival probability was 94%. For the uncemented cups the increase in revision risk after 6 years was mainly due to wear and osteolysis. For the HA-coated cups also aseptic loosening increased after 6 years of follow-up. Conclusion: Uncemented cups in young patients had good short-term results. At 10 years of follow-up for the investigated uncemented cup brands, the results were inferior to the Charnley cup.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_20 | Pages 4 - 4
1 Apr 2013
Kiran M Jariwala A Wigderowitz C
Full Access

Introduction. The aim of this study is to analyse the effect of the degree of coverage of the Total Elbow implant with cement and the significance of cementation index as a predictor of failure. Material/methods. Fifty elbows in forty seven patients who had undergone the Coonrad-Morrey TER were included in the study. The post-operative radiographs were evaluated for the cementation index. Failures and revisions were documented. Statistical analysis was done to evaluate the cementation index as a predictor of failure. Results. The mean period of follow up was 4.67 ± 2.85 years. The mean cementation index of the humerus (CIH) was 1.22 ± 0.28 (range 0.7 to 2.1). The mean cementation index of the ulna (CIU) was 1.10 ± 0.18 (range 0.77 to 1.72). The Kolmogorov-Smirnov test, used to test the type of distribution, showed that both the indices had a normal distribution (p > 0.05). Both the humeral and ulnar cementation indices were not found to be statistically significant predictors of failure (p > 0.05). Conclusions. The cementation index is an objective method of assessment of the coverage of the implant with cement. In the present series, the cementation index of the humerus varied from 0.7 to 2.1 and that of the ulna varied from 0.77 to 1.72 but both were not found to be statistically significant. A larger study with adequate follow-up should be done to establish the minimum cement mantle that can be considered adequate for the long term survivorship of the prosthesis


Bone & Joint Research
Vol. 13, Issue 5 | Pages 201 - 213
1 May 2024
Hamoodi Z Gehringer CK Bull LM Hughes T Kearsley-Fleet L Sergeant JC Watts AC

Aims

The aims of this study were to identify and evaluate the current literature examining the prognostic factors which are associated with failure of total elbow arthroplasty (TEA).

Methods

Electronic literature searches were conducted using MEDLINE, Embase, PubMed, and Cochrane. All studies reporting prognostic estimates for factors associated with the revision of a primary TEA were included. The risk of bias was assessed using the Quality In Prognosis Studies (QUIPS) tool, and the quality of evidence was assessed using the modified Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. Due to low quality of the evidence and the heterogeneous nature of the studies, a narrative synthesis was used.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 67 - 67
1 Jan 2003
Kalogrianitis S Rawal A Pydisetty R Sinopidis C Yin Q Frostick S
Full Access

Introduction: Distal humeral fractures represent a constant challenge to the most experienced surgeon. This is the first report of the use of an unlinked prosthesis for the treatment of distal humeral fractures in elderly persons. Materials and Methods: From July 2000 to June 2001, 9 iBP elbow arthroplasties were performed in patients with acute fractures of the distal humerus. The average age of the group was 71 years. The mean interval between injury and TER was 11 days. The follow-up period averaged 12 months (range 5 to 16). Results: Functional outcome was evaluated with patient-completed questionnaires. All patients had a flexion contracture of the elbow ranging from 15 to 30 degrees. All patients were able to perform daily activities, pain relief was satisfactory and patient satisfaction was high. All elbows met the criteria for functional motion and were stable at the latest follow-up examination. There were no major complications such as dislocation, ulnar nerve dysfunction or deep infection. Conclusion: Unlinked non-congruous elbow arthroplasty when combined with a surgical exposure that allows proper soft tissue balance and instrumentation that enables correct positioning of the components can be a successful alternative in the management of acute distal humeral fractures in selected patients when conventional fixation is not a viable option


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 59 - 59
1 Jun 2012
Elnikety S
Full Access

In this study we reviewed all Total Elbow Replacements (TER) done in our hospital over eight years period (1997 – 2005), 21 patients (16 females, 5 males) were available for follow up and four were lost (two died and two moved out of the region) with average age of 65 years (range 44 – 77), all procedures were done by two upper limb surgeons (CHB & RGW). 16 patients (14 females, 2 males) had the procedure for Rheumatoid Arthritis and 5 patients (3 males, 2 females) undergone the procedure for post-traumatic arthritis. The average follow up was 61 months (range 12 – 120 months), the Mayo Clinic performance index, the DASH scores and activities of daily living (adopted from Secec Elbow Score) assessment tools were used. In addition, all patients were assessed for loosening using standard AP and lateral radiographs. Sixteen patients had Souter-Starthclyde prosthesis whilst three had Kudo and two had Conrad-Moorey prosthesis. All procedures were done through dorsal approach and all were cemented, the ulnar nerve was not transposed in any of the cases. The average elbow extension lag was 27 degrees (range 15 – 35) with flexion up to 130 degrees (range 110 – 140). Supination was 65 degrees (range 15 – 90) and pronation was 77 (range 55 – 90). The average DASH score was 51.3 (range 19 – 95), the Mayo elbow score was 82 (range 55 – 100) and the average Activities of daily living Secec Score was 17 (range 10 – 20). There were four complications, three ulnar nerve paresis which recovered and one wound complication which needed a flap cover. Two needed revision surgery, one for a periprosthetic fracture and one for loosening. Two patients showed radiological signs of loosening but were asymptomatic. The survival rate with revision as the end point is 95% for aseptic loosening and 90% for any other reason. Our study proves TER has good medium term results with good functional outcome and high patient satisfaction rate


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 7 - 7
1 Apr 2012
Elnikety S Singh BI Kamal T El-Husseiny M Brooks CH Wetherell RG
Full Access

In this study we reviewed all Total Elbow Replacements (TER) done in our hospital over eight years period (1997 – 2005), 21 patients (16 females, 5 males) were available for follow up and four were lost (two died and two moved out of the region) with average age of 65 years (range 44 – 77), all procedures were done by two upper limb surgeons (CHB & RGW). 16 patients (14 females, 2 males) had the procedure for Rheumatoid Arthritis and 5 patients (3 males, 2 females) undergone the procedure for post-traumatic arthritis. The average follow up was 61 months (range 12 – 120 months), the Mayo Clinic performance index, the DASH scores and activities of daily living (adopted from Secec Elbow Score) assessment tools were used. In addition, all patients were assessed for loosening using standard AP and lateral radiographs. Sixteen patients had Souter-Starthclyde prosthesis whilst three had Kudo and two had Conrad-Moorey prosthesis. All procedures were done through dorsal approach and all were cemented, the ulnar nerve was not transposed in any of the cases. The average elbow extension lag was 27 degrees (range 15 – 35) with flexion up to 130 degrees (range 110 – 140). Supination was 65 degrees (range 15 – 90) and pronation was 77 (range 55 – 90). The average DASH score was 51.3 (range 19 – 95), the Mayo elbow score was 82 (range 55 – 100) and the average Activities of daily living Secec Score was 17 (range 10 – 20). There were four complications, three ulnar nerve paresis which recovered and one wound complication which needed a flap cover. Two needed revision surgery, one for a periprosthetic fracture and one for loosening. Two patients showed radiological signs of loosening but were asymptomatic. The survival rate with revision as the end point is 95% for aseptic loosening and 90% for any other reason. Our study proves TER has good medium term results with good functional outcome and high patient satisfaction rate


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 214 - 215
1 May 2006
Hallett A Lockerbie L Souter W
Full Access

Aim of study To determine the radiographic changes which can be regarded as indicative of probable eventual aseptic clinical loosening. Methods 150 TERs performed in 121 adult rheumatoid patients (95 female) with a mean age of 59 years (34–81) were followed up for a mean of 8 years. All X-rays until the final review or revision of each TER were independently reviewed by the principal author. The cement/bone interface around each component was divided into Zones and any radiolucencies were graded within each Zone. This data was then analysed to determine in which zones and at which grading of severity, radiolucencies are of importance in predicting aseptic loosening. ResultsHumeral Components Radiolucencies occurred quite frequently in Zones 1& 5. Where they became active and progressive, the usual pattern was for them to extend into Zones 2 and 4 and eventually into Zone 3. The incidence of lucencies of all grades of severity in Zones 1& 5 with standard humeral components was 55 and 53% respectively, in Zones 2& 4 29 and 33%, and Zone 3 18%. The significance of the radiolucencies also varied markedly in the different Zones. In Zones 1& 5, only 22% went on eventually to complete lines > Grade 3 severity in all Zones, 14% eventually requiring revision, while in Zones 2& 4, the corresponding figures were 36% with 22% requiring revision, and in Zone 3 60%, with 22% revision. The results with the long-stemmed implants showed a very similar trend, the important Zones being 2B, 4B, and 3. Ulnar Components Lucencies in Zones 1& 2 and in 3& 8 occurred in 90 & 73% of elbows respectively but are probably of little significance as only 15& 10% were later associated with the development of complete lines in other zones. The Zones of significance appear to be 5& 7, and especially Zone 6. Although lucencies were found in these Zones in only 35, 43 and 28% respectively, 49, 40 and 51% of these went on to form complete lucencies in all Zones, the eventual revision rate being 51, 21, and 32%. Conclusions Many TERs demonstrate areas of lucency on follow-up radiographs but we would argue that it is only of importance in specific locations (humeral zone 3 for the standard implant and humeral Zones 2B, 4B and 3 for the long-stemmed implant and ulnar Zones 5& 7 and especially 6) and when it is of Grade 3 severity or more. Such cases require to be monitored very regularly and carefully so as to carry out revision at the optimal time should this eventually be required


Bone & Joint 360
Vol. 6, Issue 2 | Pages 23 - 25
1 Apr 2017


Bone & Joint 360
Vol. 2, Issue 3 | Pages 27 - 29
1 Jun 2013

The June 2013 Shoulder & Elbow Roundup360 looks at: whether suture anchors are still the gold standard; infection and revision elbow arthroplasty; the variable success of elbow replacements; sliding knots; neurologic cuff pain and the suprascapular nerve; lies, damn lies and statistics; osteoarthritis; and one- or two-stage treatment for the infected shoulder revision.