Introduction. The interaction between the mobile components of total elbow replacements (TER) provides additional constraint to the elbow motion. Semi-constrained
Summary Statement. Discovery system produced effective functional improvement in both primary and revision total elbow replacement. The incidence of major complications was in an acceptable range. Introduction. The search for the ideal elbow prosthesis continues as instability and loosening remain the prime reasons for total elbow replacement (TER) failure. The Discovery Elbow System (Biomet) is one of the latest generations of linked prosthesis and has been used in UK since 2003. We report outcome of
As a treatment for end-stage elbow joint arthritis, total elbow replacement (TER) results in joint motions similar to the intact joint; however, bearing wear, excessive deformations and/or early fracture may necessitate early revision of failed implant components. Compared to hips, knees and shoulders, very little research has been focused on the evaluation of the outcomes of
Background. The quest for the perfectly designed elbow prosthesis continues as instability and loosening remain the foremost reasons for the failure of total elbow replacement (TER). The Discovery® Elbow System (Biomet, UK) (Figure 1), which has been used in UK since 2003, is one of the latest generations of linked prosthesis. This system was designed to decrease polyethylene-bushing wear, improve anatomic stem design, restore elbow joint biomechanics, and produce a hinge that could be easily revised. This report describes the short term outcome of
Purpose of study:. Total elbow replacement (TER) is one of the surgical options for treatment of severe haemophilic arthropathy of the elbow. There are only a few small series described in the literature. The goal of our study was to evaluate our cases and add these data to the known literature. Methods:. A retrospective analysis of a series of 8
Of 81 elbow replacements performed over a seven-year period, 11 were total elbow revision (TER) procedures, which were done on two men and nine women with a mean age of 61 years (40 to 70). Seven of the patients had rheumatoid arthritis, three had post-traumatic osteoarthritis and one had haemophilia. The reason for revision was aseptic loosening in eight patients and aseptic loosening with fracture in the other three. The prostheses revised were the Souter in eight patients, the Kudo in one, the GSB I in one and the Dee in one. In revision
We retrospectively analysed a single surgeon series of 22
Introduction. Primary Total Elbow Replacement (TER) is gaining popularity as a primary treatment option for osteoporotic fractures of the elbow, particularly in patients with low demand. The aim of this study was to assess the clinical and functional efficacy of
An inclusive classification system is required if valid comparisons are to be made between the various types of implants used for total elbow replacement (TER). The aim of the study was to consider the characteristics of the prostheses developed for
Cobb and Morrey (1997) reported the use of Total Elbow Replacement (TER) for patients with distal humerus fractures. In this paper, 48% of the patients had a previous history of inflammatory arthropathy. Our aim was to determine the role of
Introduction. The aim of this study is to analyse the effect of the degree of coverage of the Total Elbow implant with cement and the significance of cementation index as a predictor of failure. Material/methods. Fifty elbows in forty seven patients who had undergone the Coonrad-Morrey
The aims of this study were to identify and evaluate the current literature examining the prognostic factors which are associated with failure of total elbow arthroplasty (TEA). Electronic literature searches were conducted using MEDLINE, Embase, PubMed, and Cochrane. All studies reporting prognostic estimates for factors associated with the revision of a primary TEA were included. The risk of bias was assessed using the Quality In Prognosis Studies (QUIPS) tool, and the quality of evidence was assessed using the modified Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework. Due to low quality of the evidence and the heterogeneous nature of the studies, a narrative synthesis was used.Aims
Methods
Introduction: Distal humeral fractures represent a constant challenge to the most experienced surgeon. This is the first report of the use of an unlinked prosthesis for the treatment of distal humeral fractures in elderly persons. Materials and Methods: From July 2000 to June 2001, 9 iBP elbow arthroplasties were performed in patients with acute fractures of the distal humerus. The average age of the group was 71 years. The mean interval between injury and
In this study we reviewed all Total Elbow Replacements (TER) done in our hospital over eight years period (1997 – 2005), 21 patients (16 females, 5 males) were available for follow up and four were lost (two died and two moved out of the region) with average age of 65 years (range 44 – 77), all procedures were done by two upper limb surgeons (CHB & RGW). 16 patients (14 females, 2 males) had the procedure for Rheumatoid Arthritis and 5 patients (3 males, 2 females) undergone the procedure for post-traumatic arthritis. The average follow up was 61 months (range 12 – 120 months), the Mayo Clinic performance index, the DASH scores and activities of daily living (adopted from Secec Elbow Score) assessment tools were used. In addition, all patients were assessed for loosening using standard AP and lateral radiographs. Sixteen patients had Souter-Starthclyde prosthesis whilst three had Kudo and two had Conrad-Moorey prosthesis. All procedures were done through dorsal approach and all were cemented, the ulnar nerve was not transposed in any of the cases. The average elbow extension lag was 27 degrees (range 15 – 35) with flexion up to 130 degrees (range 110 – 140). Supination was 65 degrees (range 15 – 90) and pronation was 77 (range 55 – 90). The average DASH score was 51.3 (range 19 – 95), the Mayo elbow score was 82 (range 55 – 100) and the average Activities of daily living Secec Score was 17 (range 10 – 20). There were four complications, three ulnar nerve paresis which recovered and one wound complication which needed a flap cover. Two needed revision surgery, one for a periprosthetic fracture and one for loosening. Two patients showed radiological signs of loosening but were asymptomatic. The survival rate with revision as the end point is 95% for aseptic loosening and 90% for any other reason. Our study proves
In this study we reviewed all Total Elbow Replacements (TER) done in our hospital over eight years period (1997 – 2005), 21 patients (16 females, 5 males) were available for follow up and four were lost (two died and two moved out of the region) with average age of 65 years (range 44 – 77), all procedures were done by two upper limb surgeons (CHB & RGW). 16 patients (14 females, 2 males) had the procedure for Rheumatoid Arthritis and 5 patients (3 males, 2 females) undergone the procedure for post-traumatic arthritis. The average follow up was 61 months (range 12 – 120 months), the Mayo Clinic performance index, the DASH scores and activities of daily living (adopted from Secec Elbow Score) assessment tools were used. In addition, all patients were assessed for loosening using standard AP and lateral radiographs. Sixteen patients had Souter-Starthclyde prosthesis whilst three had Kudo and two had Conrad-Moorey prosthesis. All procedures were done through dorsal approach and all were cemented, the ulnar nerve was not transposed in any of the cases. The average elbow extension lag was 27 degrees (range 15 – 35) with flexion up to 130 degrees (range 110 – 140). Supination was 65 degrees (range 15 – 90) and pronation was 77 (range 55 – 90). The average DASH score was 51.3 (range 19 – 95), the Mayo elbow score was 82 (range 55 – 100) and the average Activities of daily living Secec Score was 17 (range 10 – 20). There were four complications, three ulnar nerve paresis which recovered and one wound complication which needed a flap cover. Two needed revision surgery, one for a periprosthetic fracture and one for loosening. Two patients showed radiological signs of loosening but were asymptomatic. The survival rate with revision as the end point is 95% for aseptic loosening and 90% for any other reason. Our study proves
Aim of study To determine the radiographic changes which can be regarded as indicative of probable eventual aseptic clinical loosening. Methods 150 TERs performed in 121 adult rheumatoid patients (95 female) with a mean age of 59 years (34–81) were followed up for a mean of 8 years. All X-rays until the final review or revision of each
The June 2013 Shoulder &
Elbow Roundup360 looks at: whether suture anchors are still the gold standard; infection and revision elbow arthroplasty; the variable success of elbow replacements; sliding knots; neurologic cuff pain and the suprascapular nerve; lies, damn lies and statistics; osteoarthritis; and one- or two-stage treatment for the infected shoulder revision.