Mortality rates reported by the National Joint Registry for England
and Wales (NJR) were higher following cemented total knee replacement
(TKR) compared with uncemented procedures. The aim of this study
is to examine and compare the effects of cemented and uncemented
TKR on the activation of selected markers of inflammation, endothelium,
and coagulation, and on the activation of selected cytokines involved
in the various aspects of the systemic response following surgery. This was a single centre, prospective, case-control study. Following
enrolment, blood samples were taken pre-operatively, and further
samples were collected at day one and day seven post-operatively.
One patient in the cemented group developed a deep-vein thrombosis
confirmed on ultrasonography and was excluded, leaving 19 patients
in this cohort (mean age 67.4, (Objective
Methods
Joint replacement implants, especially in their modular forms, are subjected to wear and corrosion at various sites in their articulation, such as the bearing surfaces, the undersurface of the insert, the femoral head-neck junction and the implant or polymethylmethacrylate-bone interface. Movement of the bearing surfaces is not the only cause, as faulty implant positioning can initiate wear through impingement between two parts of the articulation. These wear products of polyethelene or metal, in particulate form, are influential to the ultimate fate of the prostheses through the initiation of local and systemic immune reactions. These debris are phagocytised by macrophages and phagocytised proteins are partly degraded in intracellular vesicles, where they become associated with the major histocompatability complex molecule HLA-DR. This molecule when transported to the cell membrane, interacts with CD4+ lymphocytes to activate an immune response and initiate the production of interleukin1b, interleukin 6 and tumor necrosing factor a. These cytokines mediate the inflammatory response and activate osteoclasts causing periprosthetic osteolysis. Polyethelene and metal wear particles, in addition to their local effects, can be disseminated beyond the periprosthetic tissues and reach distant organs and regional lymphnodes. The concentrations of certain elements of metallic implants, such as iron, cobalt, chromium or titanium have been detected in lymphnodes, the liver and the spleen in levels a lot higher than normal, especially in patients with loose prostheses and, less so, in patients with stable prostheses. The reported values of metal ions in published series vary. Thus certain investigators (Brodner et al) have reported continuous systemic cobalt release during a five year follow-up period and in levels slightly above detection values, while others (Clarke et al, Lohtka et al) have reported consistently high levels of cobalt and chromium ions in metal on metal articulations. The diameter of the femoral head appears to be a significant factor. In surface hip replacements with large diameter heads the amount of detected metal ions was significantly higher compared with total hip replacements with use of 28mm diameter femoral heads. In that type of replacement the levels of cobalt was 50 times higher than normal and of chromium 100 times higher. Polyethelene particles, similarily have been detected in paraaortic lymphnodes in percentages similar to metal ions. However the detection of PE particles in the liver or the spleen was less, compared to metal ions, possibly due to the difficulty of modern methods to detect PE particles of submicrometre size. The relevance of the dissemination of metal ions and of PE wear debris in organs distal to the operated joint need to be carefully evaluated since certain of these elements are known carcinogens. Two studies have reported slight increase of haemopoeitic cancers in patients with cobalt alloy implants and in patients with metal on metal devices, while others have documented the development of malignant tumours in the vicinity of total hip replacements. Since prostheses with metal on metal bearing surfaces are used more and more frequently in younger patients, these patients require careful monitoring for longer periods.
Breast and other cancers commonly metastasize to bone to cause bone destruction, pain, fractures hypercalcemia and muscle weakness. Recently, we described a specific molecular mechanism by which bone-derived transforming growth factor (TGF)-beta, released as a consequence of tumor-induced bone destruction causes muscle dysfunction, before the loss of muscle mass. Circulating TGF-beta induces oxidation of the ryanodine receptor (RYR1) on the sarcoplasmic reticulum of skeletal muscle to induce calcium leak and muscle weakness. Blocking TGF-beta, or its release from bone (with bisphosphonates), preventing oxidation of or stabilizing RyR1 all prevented muscle weakness in mouse models of breast cancer bone metastases. In addition to these effects on skeletal muscle, circulating TGF-beta may act on beta cells of the pancreas to impair insulin secretion and result in glucose intolerance. These and other potential
Aim. Bone and implant-associated infections caused by microorganisms that grow in biofilm are difficult to treat because of persistence and recurrence. Systemic administration of antibiotics is often inefficient because the poor vascularization of the site of infection. This issue has led to the development of biomaterials capable to locally deliver high doses of therapeutic agents to the injured bone with minimal
Periprosthetic joint infection (PJI) in geriatric and/or multimorbid patients is an enormous challenge for orthopaedic surgeons. Revision procedures have also been demonstrated to expose patients to higher infection risks. Prior patient stratification according to presumed infection risks, followed by a more potent local antibiotic prophylaxis protocol with selective use of DALBC, is an interesting strategy to decrease the burden of PJI in high risk patients. The PubMed & EMBASE databases were screened for publications pertaining to the utilization of DALBC in cement for infection prophylaxis & prosthesis fixation. 6 preclinical & 7 clinical studies were identified which met the inclusion criteria and were stratified by level of clinical evidence. Only those studies were considered which compared the PJI outcome in the DALBC vs the SALBC group. (1). DALBC have been shown to exert a much stronger and longer lasting inhibition of biofilm formation on many PJI relevant bacteria (gram-positive and gram-negative pathogens) than single gentamicin-only containing cements. (2). DALBC use (COPAL G+C) in the intervention arm of 7 clinical studies has led to a significant reduction of PJI cases in a) cemented hemiarthroplasty procedures (3 studies, evidence level I and III), in b) cemented septic revision surgeries (2 studies, evidence level III), in c) cemented aseptic knee revisions (1 study, evidence level III) and in d) cemented primary arthroplasties in multi-morbid patients (1 study, evidence level III-IV). These benefits were not associated with more
Surgical site infections following orthopaedic surgery are a serious complication associated with increased morbidity and mortality. Intra-wound antibiotic powder may be able to provide infection prophylaxis locally with less
Background. Chronic low back pain is strongly linked to degeneration of the intervertebral disc (IVD), which currently lacks any targeted treatments. This study explores NPgel, a biomaterial combined with notochordal cells (NC), developmental precursor cells, as a potential solution. NCs, known for anti-catabolic effects on IVD cells, present a promising avenue for regenerating damaged IVD tissue. Methods. Bovine IVDs underwent enzymatic degeneration before NPgel (+/- NC) injection. Degenerated bovine IVDs were cultured under biomechanical loading for 21 days. Histology and immunohistochemistry assessed NC survival, phenotype, and matrix production. Within an in vivo sheep pilot study, NPgel (+/- NC) was injected into degenerated IVDs, blood was taken, and immune cell activation was monitored via flow cytometry over three months post-injection. Results. Within the ex vivo model, IVDs injected with NPgel (+/- NC) exhibited increased matrix expression and deposition. Viable NCs were detected post-culture, indicating survival and matrix production. In the in vivo model, NPgel injection into sheep IVDs did not significantly increase activation of immune cells compared to controls, suggesting no
There is a lack of carriers for the local delivery of rifampicin (RIF), one of the cornerstone second defence antibiotic for Staphylococcus aureus deep bone infections (DBIs). RIF is also associated with
An increase in metal ion levels is seen after implantation of all MoM hip prosthesis due to release from the surface directly, more so during articulation and corrosion of the bearing surfaces. The bearing surfaces in MoM prosthesis consist of cobalt, chromium and molybdenum. Several case-reports of cobalt toxicity due to a MoM prosthesis have been published in the last decade. Cobalt intoxication may lead to a variety of symptoms: neuro-ocular toxicity (tinnitus, vertigo, deafness, blindness, convulsions, headaches and peripheral neuropathy), cardiotoxicity and thyroid toxicity. Nausea, anorexia and unexplained weight loss have been described.
Trauma, including major Orthopaedic Surgery, results in an immuno-inflammatory response which is variable in
Summary Statement. A novel biomimetic polydioxanone tendon patch with woven and electrospun components is biocompatible, recapitulates native tendon architecture and creates a tissue-healing microenvironment directed by a subpopulation of regenerative macrophages. The woven component provides tensile strength while the tendon heals. Introduction. There is great interest in the use of biomimetic devices to augment tendon repairs. Ideally, implants improve healing without causing adverse local or systemic reactions. Biocompatibility remains a critical issue prior to implantation into humans, as some implants elicit a foreign body response (FBR) involving inflammation, poor wound healing and even fistulae formation. Additionally, the effect on articular cartilage locally or systemically with placement of a juxta-articular implant has not been examined. The purpose of this study is to test the in vivo biocompatibility of a novel hybrid woven and electrospun polydioxanone patch in a rat tendon transection model. Patients and Methods. Sixty Lewis rats were divided into 4 groups in which the infraspinatus was surgically transected 3 mm from its insertion. Tendons were repaired with a woven and electrospun polydioxanone patch (PDOe) and 5-0 Prolene sutures. Vicryl and Silk patches or a simple Prolene suture repair served as comparators. Animals were sacrificed at 1, 2, 4, 6 and 12 weeks to examine the biocompatibility of the implants. Immunohistochemistry was used to examine macrophage subpopulations and hematoxylin and eosin staining was used to assess foreign-body giant cells and both analyzed with a one-way ANOVA with significance set at p<.05. Articular cartilage was scrutinised with semi-quantitative analysis. Hind paw inflammatory indices were used to determine the
A recent French report suggested that cobalt metal ions released from total hip replacements (THRs) were associated with an increased risk of dilated cardiomyopathy and heart failure. If the association is causal the consequences would be significant given the millions of Orthopaedic procedures in which cobalt-chrome is used annually. We examined whether cobalt-chrome containing THRs were associated with an increased risk of all-cause mortality, heart failure, cancer, and neurodegenerative disorders. Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 375,067 primary THRs with up to 14·5 years follow-up. Implants were grouped as either containing cobalt-chrome or not containing cobalt-chrome. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. There were 132,119 individuals (35·2%) with an implant containing cobalt-chrome. There were 48,106 deaths, 27,406 heart outcomes, 35,823 cancers, and 22,097 neurodegenerative disorders. There was no evidence of an association that patients with cobalt-chrome implants had higher rates of any of the outcomes. For all-cause mortality there was a very small survival advantage for patients having a cobalt-chrome implant (restricted mean survival time 13·8=days, 95% CI=6·8-20·9). Cobalt-chrome containing THRs did not have an increased risk of all-cause mortality, heart failure, cancer, and neurodegenerative disorders into the second decade post-implantation. Our findings will reassure clinicians and patients that primary THR is not associated with
Fretting corrosion of taper junctions is long known and of great concern, because of metal ion and particle release and their related adverse local and
Introduction. Today, Uganda has the second highest rate of road accidents in Africa and the world after Ethiopia. According to the World Health Organization's Global Status Report on Road Safety 2013, Uganda is named among countries with alarmingly high road accident rates. If such trend of traffic accidents continues to increase, the health losses from traffic injuries may be ranked as the second to HIV/AIDS by 2020. These road traffic accidents often result in terrible open injuries. Open fractures are complex injuries of bone and soft tissue. They are orthopedic emergencies due to risk of infection secondary to contamination and compromised soft tissues and sometimes vascular supply and associated healing problems. Any wound occurring on the same limb should be suspected as result of open fracture until proven otherwise. The principles of management of open fracture are initial evaluation and exclusion of life threatening injuries, prevention of infection, healing of fracture and restoration of function to injured extremity. Because of the poor hygienic circumstances and the high rate of cross-infection due to the crowded patient-wards, the risk of getting a post-operative infection is relatively high. Osteoset-T® (Wright Medical) is a medical grade calcium sulfate bone graft substitute which is enhanced for use in infected sites by incorporating 4% tobramycin sulfate. The tobramycin is released locally, allowing therapeutic antibiotic levels at the graft site, while maintaining low systemic antibiotic levels. This local treatment of infection allows new bone formation in the defect site, while decreasing potential
Previous authors have suggested that the analgesic effects of intra-articular morphine may be beneficial. Clonidine has been found to potentiate the analgesic effect of morphine. Following knee arthroscopy, morphine has demonstrated equivocal effect in comparison to bupivicaine for analgesia while circumventing the issue of chondrotoxicity. There have been no studies evaluating the effect of intra-articular morphine following hip arthroscopy. The purpose of this study was to evaluate the efficacy of intra-articular morphine in combination with clonidine on pain and narcotic consumption following hip arthroscopy surgery for femoroacetabular impingement. A retrospective review was performed on 43 patients that underwent hip arthroscopy between September 2014 and May 2015 at our institution for femoroacetabular impingement. All patients received preoperative Celebrex and Tylenol per our anesthesia protocol, and 22 patients received an additional intra-articular injection of 10 mg morphine and 100 mcg of clonidine at the conclusion of the procedure. Narcotic consumption, duration of anesthesia recovery, and perioperative pain scores were compared between the two groups. We found that patients who received intra-articular morphine and clonidine used significantly less opioid analgesic in the PACU, with 23 mEq of morphine equivalents required in the intra-articular morphine and clonidine group compared to 40 mEq of opiod equivalents in the non-injection group (p=0.0259). There were no statistically significant differences in time spent in recovery prior to discharge or in VAS pain scores recorded immediately post-operatively and at one hour following surgery. In conclusion, we found that an intraoperative intra-articular injection of morphine and clonidine significantly reduced the amount of narcotic requirement following hip arthroscopy. We do believe that there may be significant benefits to this, including less
Evaluation of the effectiveness of biodegradable bone substitute with high doses of antibiotics in cavitary osteomyelitis and infected nonunions. The authors evaluated 8 cases, 5 of them related to osteomyelitis with bone sequestration and other 3 regarding infected nonunions. All of them had in common the persistence of infection after antibiotic therapy. All infections were confirmed by microbiological studies. In all cases the surgeons conducted a thorough surgical debridement and filling of bone defects with Herafill®. Later a tight clinical, analytical and imagiological control was performed. Five of the cases were a success with simultaneous healing of the bone loss and treatment of the infection. These corresponded to the cases of cavitary osteomyelitis. In the remaining 3 cases, despite infection eradication, union was not achieved and additional surgical procedures were required for definitive treatment of nonunion. In the treatment of bone infection, use of high doses of antibiotics at the site is a consensus as it allows eradication of the infection with lower
Metal-on-metal bearing surfaces were used frequently until recently because of the potential for decreased wear and the ability to use large femoral heads which can reduce instability. However, data reported in the Australian registry over the past 5 years demonstrated an increase in failure rates compared to metal-on-polyethylene bearings. In addition, adverse local tissue reactions (ALTR) associated with pseudotumors and destruction of the soft tissue around the joint have led to revision of these implants. Unfortunately, at the present time there is no optimal management strategy that has been delineated for metal-on-metal implants because of a lack of evidence. The biologic response to metal-on-metal implants is usually local but may be systemic. The management of these patients is complex because patients may have pseudotumors and/or elevated metal ion levels and be asymptomatic. In addition, there are a number of intrinsic causes (loosening, infection, iliopsoas tendinitis) and extrinsic causes (spinal disease, trochanteric bursitis) that can be a source of pain. There is no evidenced based approach to manage these patients and no single test should be used to determine treatment. A thorough clinical evaluation is essential and blood tests are necessary to rule out infection. Imaging studies including plain radiographs and a MARS MRI are needed to evaluate either the stability of the prosthesis and to assess for the presence of pseudotumors and soft tissue destruction around the implant. Patients with symptomatic hips and evidence of muscle involvement on MRI require revision. Finally, the clinician must always be aware of the potential for
This study aimed to determine the optimal formulation of antibiotic-loaded bone cement (ALBC) for periprosthetic joint infection (PJI) using both in vitro and in vivo models incorporating various combinations of gram-positive and gram-negative antibiotics. The in vitro antibiotic release characteristics and antibacterial capacities of ALBCs loaded with either 4 g of vancomycin or teicoplanin and 4 g of ceftazidime, imipenem, or aztreonam were measured against methicillin-susceptible S. aureus, methicillin-resistant S. aureus, coagulase-negative staphylococci, Pseudomonas aeruginosa and Escherichia coli. ALBC spacers with superior in vitro antibacterial capacity were then implanted into ten patients (five females and five males between 29 and 75 years of age) diagnosed with chronic hip/knee PJIs and antibacterial activities within joint fluid were measured. The average duration of ALBC spacer implantation was 80 days (range, 36–155 days). Antibiotic concentrations and antibacterial activities of joint fluid at the site of infection were measured during the initial period as well as several months following spacer implantation. Cement samples loaded with vancomycin/ceftazidime or teicoplanin/ceftazidime exhibited equal or longer antibacterial duration against test bacteria as compared with other ALBCs. Joint fluid samples exhibited antibacterial activity against the test microorganisms including ATCC strains and clinically isolated strains. There were no adverse
Introduction. Wear plays a key role in the clinical outcome of total hip replacements (THR). In addition, increased frictional moment can stress the implant interfaces which may lead to high torsional loadings in the intermodular taper junction (fretting) and cup loosening and to the development of noise (squeaking). Against the background of larger head diameters (increased range of motion and decreased risk of dislocation), the friction induced by the joint articulation is of particular interest. As of now, the investigation of friction with the use of relevant joint kinematics and loadings are limited to numerical studies. Experimental approaches use simplified models which do not take into consideration complex activities. Thus, with the aim of this study is the identification of articular frictional moments that consider critical in vivo loading conditions and kinematics as well as the clinical cup inclination, head size and clearance of ceramic-on-ceramic hip bearings. Materials and Methods. A standard hip simulator (Minibionix 852 with 4 DOF Hip setup, MTS, Eden Prairie, USA) was modified in order to allow for high-precision friction measurements during head-insert articulation in all 6 DOF (MC2.5D-500, AMTI, Boston, USA). Disturbing