With the drawdown from Afghanistan focus turns towards future operations, and their demands on the DMS. Training for surgeons deploying to military operations will have to take into account the decreased opportunities and experience gained by current conflicts. The aim is to focus on current UK
Freehand distal interlocking of intramedullary nails remains a challenging task. If not performed correctly it can be a time consuming and radiation expensive procedure. Recently, the AO Research Institute developed a new training device for Digitally Enhanced Hands-on
Skills simulation is increasingly used as a training tool in postgraduate
Skills simulation is increasingly used as a training tool in postgraduate
Background. Visual representation help make the ever-increasing data more attractive, thought provoking and informative. In the field of
Introduction: Most surgeons agree on basic parameters defining a successful joint replacement procedure. However, the process of acquiring the skills to achieve this level of success on a reproducible basis is much less straightforward. In reality, it is generally not possible to impart
Background. Hip fractures affect 1.6 million people globally per annum, associated with significant morbidity and mortality. A large proportion are extracapsular neck of femur fractures, treated with the dynamic hip screw (DHS). Mechanical failure due to cut-out is seen in up to 7% of DHS implants. The most important predictor of cut-out is the tip-apex distance (TAD), a numerical value of the lag screw”s position in the femoral head. This distance is determined by the psychomotor skills of the surgeon guided by fluoroscopic imaging in theatre. With the current state of
Freehand distal interlocking of intramedullary nails is technical demanding and prone to handling issues. It requires the surgeon to precisely place a screw through the nail under x-ray. If not performed accurately it can be a time consuming and radiation expensive procedure. The aims of this study were to assess construct and face validity of a new training device for distal interlocking of intramedullary nails. 53 participants (29 novices and 24 experts) were included. Construct validity was evaluated by comparing simulator metrics (number of x-rays, nail hole roundness, drill tip position and accuracy of the drilled hole) between experts and novices. Face validity was evaluated by means of a questionnaire concerning training potential and quality of simulated reality using a 7-point Likert scale (range 1-7). Mean realism of the training device was rated 6.3 (range 4-7) and mean training potential as well as need for distal interlocking training was rated 6.5 (range 5-7) with no significant differences between experts and novices, p≥0.236. All participants stated that the simulator is useful for procedural training of distal nail interlocking, 96% would like to have it at their institution and 98% would recommend it to their colleagues. Total number of x-rays were significantly higher for novices (20.9±6.4 vs. 15.5±5.3), p=0.003. Successful task completion (hit the virtual nail hole with the drill) was significantly higher in experts (p=0.04; novices hit: n=12; 44,4%; experts hit: n=19; 83%). The evaluated training device for distal interlocking of intramedullary nails yielded high scores in terms of training capability and realism. Furthermore, construct validity was established as it reliably discriminates between experts and novices. Participants see a high further training potential as the system may be easily adapted to other surgical task requiring screw or pin position with the help of x-rays.
The COVID-19 pandemic has disrupted all segments of daily life, with the healthcare sector being at the forefront of this upheaval. Unprecedented efforts have been taken worldwide to curb this ongoing global catastrophe that has already resulted in many fatalities. One of the areas that has received little attention amid this turmoil is the disruption to trainee education, particularly in specialties that involve acquisition of procedural skills. Hand surgery in Singapore is a standalone combined programme that relies heavily on dedicated cross-hospital rotations, an extensive didactic curriculum and supervised hands-on training of increasing complexity. All aspects of this training programme have been affected because of the cancellation of elective surgical procedures, suspension of cross-hospital rotations, redeployment of residents, and an unsustainable duty roster. There is a real concern that trainees will not be able to meet their training requirements and suffer serious issues like burnout and depression. The long-term impact of suspending training indefinitely is a severe disruption of essential medical services. This article examines the impact of a global pandemic on trainee education in a demanding surgical speciality. We have outlined strategies to maintain trainee competencies based on the following considerations: 1) the safety and wellbeing of trainees is paramount; 2) resource utilization must be thoroughly rationalized; 3) technology and innovative learning methods must supplant traditional teaching methods; and 4) the changes implemented must be sustainable. We hope that these lessons will be valuable to other training programs struggling to deliver quality education to their trainees, even as we work together to battle this global catastrophe.
Anterior approach total hip arthroplasty (AA-THA) has a steep learning curve, with higher complication rates in initial cases. Proper surgical case selection during the learning curve can reduce early risk. This study aims to identify patient and radiographic factors associated with AA-THA difficulty using Machine Learning (ML). Consecutive primary AA-THA patients from two centres, operated by two expert surgeons, were enrolled (excluding patients with prior hip surgery and first 100 cases per surgeon). K- means prototype clustering – an unsupervised ML algorithm – was used with two variables - operative duration and surgical complications within 6 weeks - to cluster operations into difficult or standard groups. Radiographic measurements (neck shaft angle, offset, LCEA, inter-teardrop distance, Tonnis grade) were measured by two independent observers. These factors, alongside patient factors (BMI, age, sex, laterality) were employed in a multivariate logistic regression analysis and used for k-means clustering. Significant continuous variables were investigated for predictive accuracy using Receiver Operator Characteristics (ROC). Out of 328 THAs analyzed, 130 (40%) were classified as difficult and 198 (60%) as standard. Difficult group had a mean operative time of 106mins (range 99–116) with 2 complications, while standard group had a mean operative time of 77mins (range 69–86) with 0 complications. Decreasing inter-teardrop distance (odds ratio [OR] 0.97, 95% confidence interval [CI] 0.95–0.99, p = 0.03) and right-sided operations (OR 1.73, 95% CI 1.10–2.72, p = 0.02) were associated with operative difficulty. However, ROC analysis showed poor predictive accuracy for these factors alone, with area under the curve of 0.56. Inter-observer reliability was reported as excellent (ICC >0.7). Right-sided hips (for right-hand dominant surgeons) and decreasing inter-teardrop distance were associated with case difficulty in AA-THA. These data could guide case selection during the learning phase. A larger dataset with more complications may reveal further factors.
Global surgical literature suggests that female trainees have less operative autonomy than their male counterparts. This pilot study had the primary objective to identify difference in autonomy by gender, and to power a national study to carry out further quantitative and qualitative research on this. This was a retrospective, cross-sectional study utilising eLogbook data for all orthopaedic trainees (ST2-8) and consultants with CCT date 2016–2021 in a single Scottish deanery. The primary outcome measure was percentage of procedures undertaken as lead surgeon. 15 trainees and four recent consultants participated, of which 12 (63%) were male (mean grade 5.2), and 7 (37%) were female (mean grade 4.3). Trainees were lead surgeon on 64% of procedures (17595/27558), with autonomy rising with grade (37% ST1 to 85% ST8, OR 9.4). Operative autonomy was higher in male vs female trainees (66.5% and 61.4% respectively, p=<0.0001), with female trainees more likely to operate with a supervisor present (STU/S vs P/T, f 48%:13%, m 45%:20%). This pilot study found that there was a significant difference in operative autonomy between male and female trainees, however this may be explained by differences in mean grade of male vs female trainees. Five trainees took time OOT, 4/5 of whom were female. Extension to a national multi-centre study should repeat the quantitative method of this study with additional qualitative analysis including assessing effect of time OOT to explore the reason for any gender discrepancies seen across different deaneries in the UK.
The imminent introduction of the new Trauma & Orthopaedic (T&O) curriculum, and the implementation of the Improving
Computer assisted navigation (CAN) has been shown to significantly improve the overall alignment obtained after total knee arthroplasty (TKA). Human error and the use of conventional jigs may be the reasons for the inaccuracy of conventional TKA. The impact of computer assisted equipment in surgeon training has not yet been established. Three orthopaedic trainees participated in this prospective study to assess the impact of CAN upon intraoperative alignment. Each trainee’s first five (early group) and last five (late group) TKA’s were included in the study during their three month training period. A total of 30 patients were included in the study. The accuracy of conventional jig positioning was assessed simultaneously using navigation equipment. After this assessment, the actual bony resection was performed using CAN equipment. There was a consistent trend towards improved accuracy between the early and late groups in the majority of parameters assessed. In the early group, the coronal plane tibial alignment was found to be outside the acceptable three degree range in 11 out of 15. In the late group this improved to two out of 15 (p<
0.05). An average of 2.8 degrees of tibial jig deviation during pinning was noted in the early group which improved to one degree in late group. The accuracy of jig placement in both groups was improved by CAN. Computer assisted navigation is helpful in improving the accuracy of trainee surgeons and should prove a useful adjunct in
Conventional fracture courses utilise prefabricated sawbones that are not realistic or patient specific. The aim of this study is to determine the feasibility of creating 3D fracture models and utilising them in fracture courses to teach surgical technique. We selected an AO type 2R3C2 fracture that underwent open reduction internal fixation. De-identified CT scan images were converted to a stereolithography (STL) format. This was then processed using Computer Aided Design (CAD) to create a virtual 3D model. The model was 3D printed using a combination of standard thermoplastic polymer (STP) and a porous filler to create a realistic cortical and cancellous bone. A case-based sawbone workshop was organised for residents, unaccredited registrars, and orthopaedic trainees comparing the fracture model with a prefabricated T-split distal radius fracture. Pre-operative images aided discussion of fixation, and post-operative x-rays allowed comparison between the participants fixation. Participants were provided with identical reduction tools. We created a questionnaire for participants to rate their satisfaction and experience using a Likert scale. The 3D printed fracture model aided understanding and appreciation of the fracture pattern and key fragments amongst residents and unaccredited trainees. Real case-based models provided a superior learning experience and environment to aid teaching. The generic sawbone provided easier drilling and inserting of screws. Preliminary results show that the cost of 3D printing can be comparable to generic sawbones. It is feasible to create a fracture model with a real bone feel. Further research and development is required to determine the optimum material to use for a more realistic feel. The use of 3D printed fracture models is feasible and provides an alternative to generic sawbone fracture models in providing
Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure. This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR) were recorded for each attempt.Background
Methods
Training within surgery is changing from the traditional Halstedian apprenticeship model. There is need for objective assessment of trainees, especially their technical skills, to ensure they are safe to practice and to highlight areas for development. In addition, due to working time restrictions in both the UK and the US, theatre time is being limited for trainees, reducing their opportunities to learn such technical skills. Simulation is one adjunct to training that can be utilised to both assess trainees objectively, and provide a platform for trainees to develop their skills in a safe and controlled environment. The insertion of a dynamic hip screw (DHS) relies on complex psychomotor skills to obtain an optimal implant position. The tip-apex distance (TAD) is a measurement of this positioning, used to predict failure of the implant. These skills can be obtained away from theatre using workshop bone simulation, however this method does not utilise fluoroscopy due to the associated radiation risks. FluoroSim is a novel digital fluoroscopy simulator that can recreate digital radiographs with workshop bone simulation for the insertion of a DHS guide-wire. In this study, we present the training effect demonstrated on FluoroSim. The null hypothesis states that no difference will be present between users with different amounts of exposure to FluoroSim. Medical students were recruited from three London universities and randomised into a training (n=23) and a control (n=22) cohort. All participants watched a video explanation of the simulator and task and were blinded to their allocation. Training participants completed 10 attempts in total, 5 attempts in week one, followed by a one week wash out period, followed by 5 attempts in week 2. The control group completed a single attempt each week. For each attempt, 5 metrics were recorded; TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR).Background
Methods
Since the emergence of the COVID-19 pandemic, the NHS has been under unprecedentedpressure. Elective surgery had ceased, and trauma surgery has decreased dramatically.
Abstract. Introduction. Challenges in
Aims. The aims of this study were to describe the demographic, socioeconomic, and educational factors associated with core surgical trainees (CSTs) who apply to and receive offers for higher