Advertisement for orthosearch.org.uk
Results 1 - 20 of 2287
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 34 - 34
1 Sep 2012
Friedl W Singh S Anastasiu A
Full Access

Distal radius fractures are typical and frequent fracture of elderly woman with reduced bone density. Thus implant fixation is more difficult. Dorsal and radial comminution are frequent in these patients and so reduction and angle stable osteosynthesis needed. The angle stable plate, often also multidirectional is today the most common stabilisation device. Because of the introduction of bulky and bended implants as the Micronail or Targon DR wich require difficult opening of the bone with awles we decided to test the XS radius nail witch is a 4,5mm or 3,5mm straight nail and witch is introduced after guide wire placement and over drilling with a canulated drill of the same diameter. It is locked parallel to the joint in 3 different directions with angular stability with threaded wires. Methods 16 radius sawbones were osteotomised corresponding to a A3 Fracture and stabilised with a angle stable plate (8) and XS nail (8). 1000 alternating load cycles from 20–200N were performed and the deformation was registered. Also a FE analysis with the MSC Patran/Marc softwere were performed. Also the calculated deformation in the FE study was 20% lower. Also deformation amplitude was lower with 0.31mm compared to 0.42mm in the plate group. The differences however were not significant. Both devices show good biomechanical results. The XS nail has the advantage of mainly intraosseus position, simple operation technique with introduction over a guide wire from the proc. Styloideus radii and over drilling with a canulated drill of the same size. The exposure of the N rad. superf. must be performed. First clinical evaluation is presented. Due to the results we developed a anatomically adapted XS radius nail. The results of the first 100 patients are presented. Conclusions. Both angular stable plate and XSR nail can be used in unstable distal radius fracture fixation. The mainly intraosseus position of the nail and saving of the pronator quadratus as well as lower deformation are in favour of the XSR nail. However frontal plane fractures and very comminuted fractures are better treated with a multidirectional locking plate due to technical reasones so that we use the XSR nail mainly in A3 and C1 fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 45 - 45
2 Jan 2024
Riool M Li R Hofwegen L de Boer L Loontjens J Zaat S
Full Access

Infection of implanted medical devices (biomaterials), like titanium orthopaedic implants, can have disastrous consequences, including removal of the device. These so-called biomaterial-associated infections (BAI) are mainly caused by Staphylococcus aureus and Staphylococcus epidermidis. To prevent biofilm formation using a non-antibiotic based strategy, we aimed to develop a novel permanently fixed antimicrobial coating for titanium devices based on stable immobilized quaternary ammonium compounds (QACs). Medical grade titanium implants were dip-coated in subsequent solutions of hyperbranched polymer, polyethyleneimine and 10 mM sodium iodide, and ethanol. The QAC-coating was characterized using water contact angle measurements, scanning electron microscopy, FTIR, AFM and XPS. The antimicrobial activity of the coating was evaluated against S. aureus strain JAR060131 and S. epidermidis strain ATCC 12228 using the JIS Z 2801:2000 surface microbicidal assay. Lastly, we assessed the in vivo antimicrobial activity in a mouse subcutaneous implant infection model with S. aureus administered locally on the QAC-coated implants prior to implantation to mimic contamination during surgery. Detailed material characterization of the titanium samples showed the presence of a homogenous and stable coating layer at the titanium surface. Moreover, the coating successfully killed S. aureus and S. epidermidis in vitro. The QAC-coating strongly reduced S. aureus colonization of the implant surface as well as of the surrounding tissue, with no apparent macroscopic signs of toxicity or inflammation in the peri-implant tissue at 1 and 4 days after implantation. An antimicrobial coating with stable quaternary ammonium compounds on titanium has been developed which holds promise to prevent BAI. Non-antibiotic-based antimicrobial coatings have great significance in guiding the design of novel antimicrobial coatings in the present, post-antibiotic era. Acknowledgements: This research was financially supported by the Health∼Holland/LSH-TKI call 2021–2022, project 25687, NACQAC: ‘Novel antimicrobial coatings with stable non-antibiotic Quaternary Ammonium Compounds and photosensitizer technology'


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 29 - 29
24 Nov 2023
Riool M Li R van Hofwegen L Vavilthota N de Boer L Loontjens J Zaat S
Full Access

Aim. The use of medical devices has grown significantly over the last decades, and has become a major part of modern medicine and our daily life. Infection of implanted medical devices (biomaterials), like titanium orthopaedic implants, can have disastrous consequences, including removal of the device. For still not well understood reasons, the presence of a foreign body strongly increases susceptibility to infection. These so-called biomaterial-associated infections (BAI) are mainly caused by Staphylococcus aureus and Staphylococcus epidermidis. Formation of biofilms on the biomaterial surface is generally considered the main reason for these persistent infections, although bacteria may also enter the surrounding tissue and become internalized within host cells. To prevent biofilm formation using a non-antibiotic based strategy, we aimed to develop a novel permanently fixed antimicrobial coating for titanium devices based on stable immobilized quaternary ammonium compounds (QACs). Method. Medical grade titanium implants (10×4×1 mm) were dip-coated in a solution of 10% (w/v) hyperbranched polymer, subsequently in a solution of 30% (w/v) polyethyleneimine and 10 mM sodium iodide, using a dip-coater, followed by a washing step for 10 min in ethanol. The QAC-coating was characterized using water contact angle measurements, scanning electron microscopy, FTIR, AFM and XPS. The antimicrobial activity of the coating was evaluated against S. aureus strain JAR060131 and S. epidermidis strain ATCC 12228 using the JIS Z 2801:2000 surface microbicidal assay. Lastly, we assessed the in vivo antimicrobial activity in a mouse subcutaneous implant infection model with S. aureus administered locally on the QAC-coated implants prior to implantation to mimic contamination during surgery. Results. Detailed material characterization of the titanium samples showed the presence of a homogenous and stable coating layer at the titanium surface. Moreover, the coating successfully killed S. aureus and S. epidermidis in vitro. The QAC-coating strongly reduced S. aureus colonization of the implant surface as well as of the surrounding tissue, with no apparent macroscopic signs of toxicity or inflammation in the peri-implant tissue at 1 and 4 days after implantation. Conclusions. An antimicrobial coating with stable quaternary ammonium compounds on titanium has been developed which holds promise to prevent BAI. Non-antibiotic-based antimicrobial coatings have great significance in guiding the design of novel antimicrobial coatings in the present, post-antibiotic era


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 89 - 89
1 Nov 2021
Zderic I Caspar J Blauth M Weber A Koch R Stoffel K Finkemeier C Hessmann M Gueorguiev B
Full Access

Introduction and Objective. Intramedullary nails are frequently used for treatment of unstable distal tibia fractures. However, insufficient fixation of the distal fragment could result in delayed healing, malunion or nonunion. The quality of fixation may be adversely affected by the design of both the nail and locking screws, as well as by the fracture pattern and bone density. Recently, a novel concept for angular stable nailing has been developed that maintains the principle of relative stability and introduces improvements expected to reduce nail toggling, screw migration and secondary loss of reduction. It incorporates polyether ether ketone (PEEK) inlays integrated in the distal and proximal canal portions of the nail for angular stable screw locking. The nail can be used with new standard locking screws and low-profile retaining locking screws, both designed to enhance cortical fixation. The low-profile screws are with threaded head, anchoring in the bone and increasing the surface contact area due to the head's increased diameter. The objective of this study was to investigate the biomechanical competence of the novel angular stable intramedullary nail concept for treatment of unstable distal tibia fractures, compared with four other nail designs in an artificial bone model under dynamic loading. Materials and Methods. The distal 70 mm of thirty artificial tibiae (Synbone) were assigned to 5 groups for distal locking using either four different commercially available nails – group 1: Expert Tibia Nail (DePuy Synthes); group 2: TRIGEN META-NAIL with Internal Hex Captured Screws (Smith & Nephew); group 3: T2 Alpha with Locking Screws (Stryker); group 4: Natural Nail System featuring StabiliZe Technology (Zimmer) – or the novel angular stable TN-Advanced nail with low-profile screws (group 5, DePuy Synthes). The distal locking in all groups was performed using 2 mediolateral screws. All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading in internal rotation until failure, with monitoring by means of motion tracking. Results. Initial nail toggling of the distal tibia fragment in group 5 was significantly lower as compared with group 3 in varus (p=0.04) or with groups 2 and 4 in flexion (p≤0.02). In addition, the toggling in varus was significantly lower in group 1 versus group 4 (p<0.01). Moreover, during dynamic loading, within the course of the first 10,000 cycles the movements of the distal fragment in terms of varus, flexion, internal rotation, as well as axial and shear displacements at the fracture site, were all significantly lower in group 5 compared with group 4 (p<0.01). Additionally, group 5 demonstrated significantly lower values for flexion versus groups 2 and 3 (p≤0.04), for internal rotation versus group 1 (p=0.03), and for axial displacement versus group 3 (p=0.03). A trend to significantly lower values was detected in group 5 versus group 1 for varus, flexion and shear displacement – with p ranging between 0.05 and 0.07 – and versus group 3 for shear displacement (p=0.07). Cycles to failure were highest in group 5 with a significant difference to group 4 (p<0.01). Conclusions. From a biomechanical perspective, the novel angular stable intramedullary nail concept with integrated PEEK inlays and low-profile screws provides ameliorated resistance against nail toggling and loss of reduction under static and dynamic loading compared with other commercially available intramedullary nails used for fixation of unstable distal tibia fractures


Abstract. INTRODUCTION. The anatomic distal femoral locking plate (DF-LCP) has simplified the management of supracondylar femoral fractures with stable knee prostheses. Osteoporosis and comminution seem manageable, but at times, the construct does not permit early mobilization. Considerable soft tissue stripping during open reduction and internal fixation (ORIF) may delay union. Biological plating offsets this disadvantage, minimizing morbidity. Materials. Thirty comminuted periprosthetic supracondylar fractures were operated from October 2010 to August 2016. Fifteen (group A) were treated with ORIF, and fifteen (group B) with closed (biological) plating using the anatomical DF-LCP. Post-operatively, standard rehabilitation protocol was followed in all, with hinged-knee-brace supported physiotherapy. Clinico-radiological follow-up was done at 3 months, 6 months, and then yearly (average duration, 30 months), and time to union, complications, failure rates and function were evaluated. Results. Average time to union was 4.5 months (range, 3–6 months) in group A, and 3.5 months (range, 2.5–5 months) in group B. Primary bone grafting was done in twelve patients (all group A). At final follow-up, all fractures had healed, and all (but two) patients were walking unsupported, with no pain or deformity, with average knee range of motion (ROM) of 90° (range, 55 to 100°). Two patients had superficial infection (group A), two had knee stiffness (group A), one had shortening of 1.5cm (group B) and one had valgus malalignment of 10 degrees (group B). Conclusion. Biological plating in comminuted supracondylar fractures about stable TKA prostheses is an excellent option, may obviate need for bone grafting, and reducing complications


Bone & Joint Open
Vol. 4, Issue 9 | Pages 713 - 719
19 Sep 2023
Gregersen MG Justad-Berg RT Gill NEQ Saatvedt O Aas LK Molund M

Aims. Treatment of Weber B ankle fractures that are stable on weightbearing radiographs but unstable on concomitant stress tests (classified SER4a) is controversial. Recent studies indicate that these fractures should be treated nonoperatively, but no studies have compared alternative nonoperative options. This study aims to evaluate patient-reported outcomes and the safety of fracture treatment using functional orthosis versus cast immobilization. Methods. A total of 110 patients with Weber B/SER4a ankle fractures will be randomized (1:1 ratio) to receive six weeks of functional orthosis treatment or cast immobilization with a two-year follow-up. The primary outcome is patient-reported ankle function and symptoms measured by the Manchester-Oxford Foot and Ankle Questionnaire (MOxFQ); secondary outcomes include Olerud-Molander Ankle Score, radiological evaluation of ankle congruence in weightbearing and gravity stress tests, and rates of treatment-related adverse events. The Regional Committee for Medical and Health Research (approval number 277693) has granted ethical approval, and the study is funded by South-Eastern Norway Regional Health Authority (grant number 2023014). Discussion. Randomized controlled trials are needed to evaluate alternative nonoperative treatment options for Weber B/SER4a ankle fractures, as current clinical guidelines are based on biomechanical reasoning. The findings will be shared through publication in peer-reviewed journals and presentations at conferences. Cite this article: Bone Jt Open 2023;4(9):713–719


Bone & Joint Open
Vol. 4, Issue 10 | Pages 728 - 734
1 Oct 2023
Fokkema CB Janssen L Roumen RMH van Dijk WA

Aims

In the Netherlands, general practitioners (GPs) can request radiographs. After a radiologically diagnosed fracture, patients are immediately referred to the emergency department (ED). Since 2020, the Máxima Medical Centre has implemented a new care pathway for minor trauma patients, referring them immediately to the traumatology outpatient clinic (OC) instead of the ED. We investigated whether this altered care pathway leads to a reduction in healthcare consumption and concomitant costs.

Methods

In this retrospective cohort study, patients were included if a radiologist diagnosed a fracture on a radiograph requested by the GP from August to October 2019 (control group) or August to October 2020 (research group), on weekdays between 8.30 am and 4.00 pm. The study compared various outcomes between groups, including the length of the initial hospital visit, frequency of hospital visits and medical procedures, extent of imaging, and healthcare expenses.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 41 - 41
10 May 2024
Sandiford NA Atkinson B Trompeter A Kendoff D
Full Access

Introduction. Management of Vancouver type B1 and C periprosthetic fractures in elderly patients requires fixation and an aim for early mobilisation but many techniques restrict weightbearing due to re-fracture risk. We present the clinical and radiographic outcomes of our technique of total femoral plating (TFP) to allow early weightbearing whilst reducing risk of re-fracture. Methods. A single-centre retrospective cohort study was performed including twenty-two patients treated with TFP for fracture around either hip or knee replacements between May 2014 and December 2017. Follow-up data was compared at 6, 12 and 24 months. Primary outcomes were functional scores (Oxford Hip or Knee score (OHS/OKS)), Quality of Life (EQ-5D) and satisfaction at final follow-up (Visual Analogue Score (VAS)). Secondary outcomes were radiographic fracture union and complications. Results. Mean OHS and OKS was 50.25, EQ-5D score was >4 for all modalities, VAS was 64.4/100. Radiographs demonstrated bony union in 58% at 3 months and 76% at 6 months. We identified no case of re-fracture however non-union occurred in 4 patients. No other operative complications were identified. Conclusion. These results suggest that TFP may be a safe, viable option for management of periprosthetic fractures around stable implants allowing the benefit of early weightbearing, satisfactory outcomes and low re-fracture risk


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 107 - 107
1 Dec 2020
Omidi-Kashani F Binava R Arki ZM Keshtan FG Madarshahian D
Full Access

Objective. Lumbar spinal stenosis (LSS) is a common spinal disorder mostly caused by the arthritic process. In cases with refractory complaints or significant neurologic deficit, decompressive surgery with or without instrumented fusion may be indicated. We aimed to investigate the surgical outcome of multi-level LSS in the patient with stable spine treated by simple decompression versus decompression and instrumented fusion. Methods: We retrospectively studied 51 patients (25 male, 26 female) with stable multi-level (>2 levels) LSS who were treated by decompressive surgery alone (group A, 31 cases) and decompression and instrumented fusion (group B, 20 cases) and followed them for more than two years. The patients’ disability and pain were assessed with Oswestry Disability Index (ODI) and Visual Analogue Scale (VAS), respectively. At the last follow-up visit, patient satisfaction with surgery was also scored. Results: The two groups were homogeneous in terms of age, sex, severity of disability and pain. Surgery could significantly improve pain and disability in both groups. Preoperative ODI in group A and B were 51.0±23.7 and 54.5±22.9, respectively, however at the last follow-up visit these parameters improved to 23.1±21.1 and 36.6±21.4 showing a statistical significance. Mean patient satisfaction with surgical intervention was also higher in the simple decompression group, but this difference was not significant. Conclusion: In surgical treatment of the patients with multi-level but stable LSS, simple decompression versus decompression and instrumented fusion could achieve more disability improvement for more than two years of follow-up


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 7 - 7
10 Oct 2023
Chambers M Madeley N
Full Access

Stable Weber B fractures are typically treated non-operatively without complications but require close monitoring due to concerns over potential medial deltoid ligament injuries and the risk of delayed talar shift. Following recent evidence suggesting this is unlikely, a functional protocol with early weight bearing was introduced at Glasgow Royal Infirmary (GRI) following a pilot audit. This study aims to evaluate the risk of delayed talar shift in isolated Weber B fractures managed with functional bracing and early weight-bearing, particularly if signs of medial ligament injury are present. We conducted a retrospective review of 148 patients with isolated Weber B fractures without talar shift at presentation that were reviewed at the virtual fracture clinic at our institution between July 2019 and June 2020. The primary outcome was the incidence of delayed talar shift. Secondary outcomes were other complications and adherence to protocol. 48 patients had medial signs present and of these 1 (2%) showed possible talar shift on X-rays at 4 weeks, and was kept under review. This patient had a normal medial clear space at 3 months. No patients with medial signs not documented (n=19) or not present (n=81) had delayed talar shift. 10% of patients (n=15) had at least 1 complication: delayed union (n=2); non-union (n=3); ongoing pain (n=14). Functional bracing with early weight-bearing is a safe, effective protocol for managing isolated Weber B fractures without initial talar shift. This study concludes that the risk of delayed talar shift is low in all patients, with or without medial signs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 7 - 7
23 Jun 2023
van Hellemondt GG Faraj S de Windt T van Hooff M Spruit M
Full Access

Pelvic discontinuity (PD) is a detrimental complication following total hip arthroplasty (THA). The aim of this study was to assess the clinical and radiological results of patients with PD who were revised using a custom-made triflange acetabular component (CTAC). This is a single centre prospective study of patients with PD following THA who were treated with a CTAC. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Clinical and radiological complications, including reasons for revisions were registered. Trends over time are described and tested for significance and clinical relevance. 18 females with 22 CTACs were included with a mean age of 73.5 years (SD 7.7). There were significant improvements between baseline and final follow-up in HOOS (p<0.01), mOHS (p<0.01), EQ-5D-3L utility (p<0.01), EQ-5D-3L NRS (p<0.01), VAS pain rest (p<0.01), and VAS pain activity (p<0.01). A minimal clinically important improvement in mOHS and the HOOS was observed in 16 patients (73%) and 14 patients (64%), respectively. Definite healing of the PD was observed in 19 hips (86%). Complications included six cases with broken screws (27%), four cases (18%) with bony fractures, and one case (4.5%) with sciatic nerve paresthesia. One patient with concurrent bilateral PD had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage. This is the first prospective assessment in clinical outcome of patients with PD who were treated with a CTAC. We have demonstrated that CTAC in patients with THA acetabular loosening and PD can result in stable constructs with no mechanical failures. Moreover, clinically relevant improvements in health-related quality of life at two years’ follow-up was observed


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 52 - 52
1 May 2012
Dalal S Barrie J
Full Access

Introduction. Many common fractures are inherently stable, will not displace and do not require plaster casting to achieve union in a good position. Nevertheless, many patients with stable fractures are advised that they need a cast, despite the potential for stiffness, skin problems and thromboembolism. Attempts to challenge this practice often meet the argument that patients prefer a cast for pain relief. We analysed five years of a single consultant's fracture clinic to see how many patients with stable foot and ankle fractures chose a cast after evidence-based counselling. Materials and methods. All patients with stable fractures of the ankle or metatarsals seen between 1st June 2005 and 31st May 2010 were included. Displaced or potentially unstable ankle fractures, Jones fractures and fractures involving the Lisfranc joint were excluded. Patients were advised functional treatment but offered a cast if they wished. Patients were documented prospectively as part of a larger audit, including demographics, diagnosis and treatment in the emergency department and fracture clinic. Results. 93 patients had stable ankle fractures. One (1%) chose a cast, 77 an ankle brace and 14 the RICE regime. One was advised a cast for neurological deformity. 105 patients had fifth metatarsal fractures outside the “non-” zone. 19 (18%) chose casts and 86 followed the RICE regime. 50 patients had other stable metatarsal fractures 15 (30%) chose casts. 86% of patients had casts applied in the emergency department. Discussion. The majority of patients with stable foot and ankle fractures do not wish to wear a cast once they understand it will not affect their outcome. In many cases this decision could have been reached in the emergency department with appropriate guidelines and education, preventing patient inconvenience and possible adverse events. Conclusion. Most patients are happy with evidence-based functional treatment of stable fractures


Bone & Joint Research
Vol. 4, Issue 10 | Pages 170 - 175
1 Oct 2015
Sandberg OH Aspenberg P

Objectives. Healing in cancellous metaphyseal bone might be different from midshaft fracture healing due to different access to mesenchymal stem cells, and because metaphyseal bone often heals without a cartilaginous phase. Inflammation plays an important role in the healing of a shaft fracture, but if metaphyseal injury is different, it is important to clarify if the role of inflammation is also different. The biology of fracture healing is also influenced by the degree of mechanical stability. It is unclear if inflammation interacts with stability-related factors. Methods. We investigated the role of inflammation in three different models: a metaphyseal screw pull-out, a shaft fracture with unstable nailing (IM-nail) and a stable external fixation (ExFix) model. For each, half of the animals received dexamethasone to reduce inflammation, and half received control injections. Mechanical and morphometric evaluation was used. Results. As expected, dexamethasone had a strong inhibitory effect on the healing of unstable, but also stable, shaft fractures. In contrast, dexamethasone tended to increase the mechanical strength of metaphyseal bone regenerated under stable conditions. Conclusions. It seems that dexamethasone has different effects on metaphyseal and diaphyseal bone healing. This could be explained by the different role of inflammation at different sites of injury. Cite this article: Bone Joint Res 2015;4:170–175


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims

Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.

Methods

A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 74 - 74
1 Aug 2013
Fleming M Dachs R du Plessis J Vrettos B Roche S
Full Access

Purpose:. To review the union rates, outcomes and complications of angular stable plating of lateral third clavicle fractures. Method:. Between 2007 and 2010 angular stable plates were used in the fixation for seventeen patients with displaced lateral third clavicle fractures (Allman Group II, Type 2). These were identified from surgical log books and operation codes. The surgical and clinical notes as well as X-rays were reviewed. The patients were contacted telephonically. An Oxford Shoulder Score and questions relating to plate removal, scar pain and return to activities were asked. Three patients were not contactable. Results:. There were 16 males. The average age was 44. The average time to union was 3 months (range 2 to 4). There were no complications. The average Oxford Shoulder Score was 13 (range 12–19). No plates have required removal but 2 patients have requested removal for discomfort. All but 3 patients have returned to full activity. Conclusion:. The use of angular stable plates for fixation of type 2 lateral end of clavicle fractures results in excellent union rates by 3 months with only 3 patients requesting elective plate removal. This is in contrast to hook plates which require mandatory removal. No other complication was encountered


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 199 - 199
1 Mar 2003
Masry ME El Assuity IW Chan D
Full Access

Introduction: Allen and Ferguson in 1982 described five stages of compression extension injury to the cervical spine; the first stage that was considered as a stable injury involves fracture of the articular process, pedicle or lamina which may be associated with a rotary spondylolisthesis. This fracture pattern, which is not uncommonly missed on the initial X-rays, can be diagnosed using CT scanning especially if patients present with root symptoms. This fracture will be usually treated conservatively as a stable injury. In practice we found out that this type of bony fracture might present later on with subluxation and/or persistence of symptoms even if treated in rigid immobilisation devices including halo jacket. The hypothesis around this fracture pattern will be a hyperextension mechanism combined with a degree of lateral tilt and rotation producing an anterior annular disruption under tension and a unilateral posterolateral mass or laminar fracture under compression with a resultant rotational instability around the intact lateral mass. Material and Methods: Ten patients with stage I compression extension injury who presented with subluxation were studied prospectively aiming for addressing the patho-anatomy and define a method for treatment. All the cases presented with neurological manifestations, nine cases with root symptoms and one case with incomplete cord injury. The treatment consisted of early closed reduction followed by anterior fusion and fixation. Results and Conclusion: All patients showed neurological improvement. Radiological union was achieved in all the patients with maintenance of the alignment. In conclusion, extension compression injury type I (fracture of the bony posterior elements) is usually a stable injury but if there is additional failure of the disc this segment will be rendered rotationally unstable. Despite the limited number of patients in this series the results of early anterior fusion with fixation were very satisfactory encouraging the recommendation for using this type of treatment


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 467 - 467
1 Apr 2004
Tay A Nivbrant B Roehrl S Li M
Full Access

Introduction Debonding at the cement-prosthesis interface leading to stem movement and abrasion, has been proposed as initiating events in aseptic loosening of cemented total hip arthroplasties. A polished tapered or an absolutely stable stem possibly minimises this risk. This study evaluated a cemented, precoated femoral stem for stable fixation. Methods The study included 24 patients, mean age of 64 years (48 to 78) undergoing single total hip arthroplasty for osteoarthritis. All were treated with cemented Definition (Stryker) stems which are straight, chromium-cobalt, with an integrated proximal polymethylmethacrylate mantle. One surgeon using fourth generation cementation techniques performed all surgeries. UHMWPE cups and Zirconia heads were used. At the time of surgery, tantalum markers were inserted into the femur, cement and stem for Radiostereometric analysis (RSA) of migration. Measurements were performed at two, 12 and 24 months intervals. Standard radiographs and Harris Hip Scores were obtained post-operatively and at two years. Results During the first two years post-operatively the stems were shown to be absolutely fixed within the cement mantle and the mantle itself stable with the femur. At two years the mean subsidence of the stem in relation to the femur was 0.00 mm (SD 0.1), while the cement mantle subsided 0.2 mm (SD 0.2) in relation to the femur. The femoral head mean rotation was 0.02 retroversion. Postoperative radiolucent lines of > 1 mm where present in a mean of 1.4% (0 to 5%) of the cement-bone interfaces. This remained unchanged at two years (0 to 3%). Stems were in average positioned 0.8 in varus (1.2 valgus to 4.0 varus). Harris Hip Scores improved from a mean of 46 (23 to 68) pre-operatively to 93 (57 to 100) at two years. Conclusions This is the first stem where no migration could be detected during the first two years. These results so far indicate good long-term performance of this precoated stem


Bone & Joint Open
Vol. 5, Issue 2 | Pages 123 - 131
12 Feb 2024
Chen B Duckworth AD Farrow L Xu YJ Clement ND

Aims

This study aimed to determine whether lateral femoral wall thickness (LWT) < 20.5 mm was associated with increased revision risk of intertrochanteric fracture (ITF) of the hip following sliding hip screw (SHS) fixation when the medial calcar was intact. Additionally, the study assessed the association between LWT and patient mortality.

Methods

This retrospective study included ITF patients aged 50 years and over treated with SHS fixation between 2019 and 2021 at a major trauma centre. Demographic information, fracture type, delirium status, American Society of Anesthesiologists grade, and length of stay were collected. LWT and tip apex distance were measured. Revision surgery and mortality were recorded at a mean follow-up of 19.5 months (1.6 to 48). Cox regression was performed to evaluate independent risk factors associated with revision surgery and mortality.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 491 - 491
1 Apr 2004
Darwono A
Full Access

Introduction The aim of this study was to assess the effectiveness of percutaneous vertebroplasty as an invervention therapy in symptomatic vertebral compression fractures on pain relief and improvement of the quality of life of the patients. The increasing elderly population is assumed to be associated with an increased incidence of osteoporotic vertebral compression fractures. These fractures lead to a severe morbidity, decreasing quality of life, worsening co-morbidity and sometimes resulting in death. It is justifiable to treat stable vertebral compression fractures by non-operative therapy. Previous studies have shown that vertebroplasty as a non-operative treatment increases the vertebral body strength, restores vertebral body stiffness, reinforces fractured bone, prevents further deformity and alleviates the local pain. Complication rates are reputed to be low. Methods This is a prospective clinical study of percutaneous vertebroplasty in treating stable vertebral compression fractures. Since January 2001, 30 patients were treated by percutaneous vertebroplasty for 58 osteoporotic compression vertebral fractures, four non-osteoporotic stable compression fractures, two compression vertebral fractures due to metastatic carcinoma of the prostate and one due to metastatic carcimona of the cervix. Bone cement PMMA (Howmedica) mixed with Vancomycin antibiotic, and Tantalum Dust Powder (Cook Medical Co) was inserted to the facture site using Oseo-Site Bone Biopsy needle (Cook Medical Co). Pre and post treatment pain, morbidity, quality of life, hospital stay, complication and long term results were evaluated. Results The average hospital stay after vertebroplasty was 2.2 days. Signficant pain relief from 9.9 (pain scale) to 1.8. Improvement of the quality of life: siting, standing, walking without a lumbar brace was achieved one day after the treatment. In some cases the delay of improvement was influenced by the co-morbidity of the patients. No complications were found during the procedure of this treatment. Conclusions Vertebroplasy provided a promisingly good result in alleviating the local pain and improving the quality of life in osteoporotic thoraco-lumbar compression fractures. Prospective and long term results should be evaluated in greater sample size for non osteoporotic stable compression fractures. Although vertebroplasty does not change the nature of carcinoma, it improves the rest of the quality of life of someone suffering from metastatic fractures. In relation to the conduct of this study, one or more of the authors has received, or is likely to receive direct material benefits


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 232 - 232
1 Jul 2008
Osarumwense D Jena D Feldman A
Full Access

Background: Ankle fractures in adults are an increasing part of the workload of orthopaedic surgeons today. Stable ankle fractures are usually managed conservatively and followed up in the fracture clinic to identify any later displacement which may lead to the need for surgical treatment. the guidelines for follow up varies from place to place with equally varying outcomes. the aim of this study was to look at the pattern and outcome of follow up of these fractures and also the influence, if any, of serial radiological imaging during this period. Methods: We retrospectively reviewed the follow up of patients who were refered to the clinic as stable ankle fractures and who were treated conservatively following their first clinic attendance. the period covered was April 2002 to march 2003 and we also assessed the documentation of medial side tenderness from the casenotes. Results: 66 patients were identified consisting of 44 Weber A, 20 Weber B and 2 Weber C fractures with an average follow up of 10weeks. 82% of cases had documented medial side tenderness. None of the Weber A fractures displaced, irrespective of weight bearing instructions and medial side tenderness. Only 2(10%) of the Weber B and 1 (50%) of the Weber C fractures required surgical intervention due to displacement detected after clinic review at week one. Conclusion: Weber A fractures are inherently stable injuries, do not displace over time and hence do not require further clinic attendances and xrays after the first consultation. Beyond the first week, regular clinic reviews and serial xrays are not necessary in the treatment of Weber B ankle fractures. The presence of medial side tenderness was a poor indicator for joint instability in this series. with proper protocols in place, these can lead to a significant decrease in the workload of orthopaedics surgeons