Advertisement for orthosearch.org.uk
Results 1 - 20 of 33
Results per page:
Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 401 - 401
1 Oct 2006
Ibrahim T Ong S Taylor G
Full Access

Background: Aseptic loosening of total joint arthroplasty is characterised by osteolysis caused by osteoclasts and macrophages. Osteolysis occurs by acidification and dissolution of hydroxyapatite crystals then proteolysis of the bone collagen matrix. N-Telopeptide (NTx) and deoxypyridinolone (DPD) represent highly specific markers for bone resorption. Aim: To investigate whether urinary NTx and DPD generated in-vivo can be used as bone markers in a small animal model of wear debris induced osteolysis. Materials and Methods: 41 and 38 urinary samples were collected from mice at autopsy four weeks following either the implantation of clinically relevant ceramic particles or sham surgery into their femora and assayed for NTx and DPD respectively. Bone markers were corrected for urinary creatinine. Results: The mean urinary NTx concentration for mice that underwent the implantation of clinically relevant ceramic particles was 95.0 nM BCE/mM creatinine compared to 85.3 nM BCE/mM creatinine for mice who had sham surgery (p = 0.8, 95%CI: −29.0 to 30.7). The mean urinary DPD concentration for mice that underwent the implantation of clinically relevant ceramic particles was 5.3 nM DPD/mM creatinine compared to 4.0 nM DPD/ mM creatinine for mice who had sham surgery (p = 0.07, 95%CI: −2.8 to 1.4). Conclusion: The absolute values of NTx and DPD increased in mice that underwent the implantation of clinically relevant ceramic particles compared to sham surgery even though this was not statistically significant. Extending the post operative interval might allow both NTx and DPD to be utilised as bone markers of osteolysis in our small animal model of aseptic loosening


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 398 - 398
1 Oct 2006
Ibrahim T Ong S Taylor G
Full Access

Background: The commonest cause of long term failure of total joint arthroplasty is aseptic loosening. As a result, many patients will require complex revision surgery that is not only technically challenging but associated with poorer results. Revisions procedures are also associated with higher morbidity and costs. Aim: To quantify osteolysis in a small animal model of aseptic loosening. This model can then be utilised for screening therapeutic agents to inhibit aseptic loosening. Materials and Methods: 7 time mated female mice were injected with radioactive calcium 45 on day 14 of gestation. The 52 offsprings were divided into 2 equal groups and subjected to either the implantation of clinically relevant ceramic particles or sham surgery into their femora. The non-operated femora were used as control. Animals were killed 4 weeks following surgery. Femora were retrieved, dissolved and radioactivity measured as outcome (CPM/mg = Counts Per Minute per milligram). A Linear mixed effects model was utilised to examine the difference in outcome between the 2 groups. Results: The mean scintillation count for sham surgery was 388 CPM/mg compared to 449 CPM/mg in the control femora. The mean scintillation count for ceramic particles was 351 CPM/mg compared to 420 CPM/mg in the control femora. The mean effect on outcome of surgery with ceramic particles relative to sham surgery was estimated at 16.7 CPM/mg (95CI%: 0.9 to 32.5 CPM/mg; p = 0.025). Conclusion: We have successfully shown that this model can quantify osteolysis. However, the difference detected between sham surgery and ceramic particles was biologically small displaying the inert properties of ceramic. Extending the post surgery interval might show a larger difference between sham surgery and ceramic particles and permit quantitative analysis of therapeutic agents to be screened to inhibit aseptic loosening


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 391 - 391
1 Jul 2008
Mills L Noble B Fenwick S Simpson H
Full Access

Introduction: Atrophic nonunion is a well recognised complication of long bone fractures. Clinical trials show that BMP-2 accelerates healing and reduces nonunion in open tibial fractures. We are interested in a natural small molecule that has been previously demonstrated to stimulate angiogenesis in vivo. Our aim is to assess the two treatments in the prevention of nonunion. The small animal model we used is a non-critical size defect of the tibia deprived it of its blood supply by surgical stripping of the periosteum and curetting of the local endosteum thus closely reflecting the clinical situation. The outcomes were measured by radiographic assessment and histology. Methods: Wistar rats were treated with either the angiogenic molecule (0.1% or 0.003%), BMP-2 or vehicle alone (PBS) soaked in a type I collagen sponge. All animals underwent a 2mm osteotomy, stripping of the periosteum and endosteum proximally and distally for the length of the diameter of the tibia. Fluorescent markers were injected at 2 weekly intervals. The rats were sacrificed at 8 weeks. Both tibiae were disarticulated; fixator and soft tissues were removed and AP and lateral X-rays were taken. Subjective assessment of the healing on X-ray was carried out in two ways; using a radiographic scoring system and by grey scale analysis. The samples were embedded, sectioned and stained for new bone formation. Results: Bridging or potential to bridge was seen in a number of animals on x-ray. Bridging or potential to bridge was judged to be present in 72.22% of the BMP-2 group and 66.67% of the high dose group compared to 22.22% of the control group. Histological analysis is being performed to confirm these findings. Discussion: Atrophic nonunion is a serious clinical complication, unfortunately BMP-2 is a highly costly treatment option and therefore alternative molecular therapies are much sought after. We describe here an angiogenic molecule has some potential in preventing formation of nonunion


Bone & Joint Research
Vol. 3, Issue 6 | Pages 203 - 211
1 Jun 2014
Onur T Wu R Metz L Dang A

Objectives

Our objective in this article is to test the hypothesis that type 2 diabetes mellitus (T2DM) is a factor in the onset and progression of osteoarthritis, and to characterise the quality of the articular cartilage in an appropriate rat model.

Methods

T2DM rats were obtained from the UC Davis group and compared with control Lewis rats. The diabetic rats were sacrificed at ages from six to 12 months, while control rats were sacrificed at six months only. Osteoarthritis severity was determined via histology in four knee quadrants using the OARSI scoring guide. Immunohistochemical staining was also performed as a secondary form of osteoarthritic analysis.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 31 - 31
14 Nov 2024
Bal Z Takakura N
Full Access

Introduction. Femoral head osteonecrosis (FHO) is a condition in which the inadequate blood supply disrupts osteogenic-angiogenic coupling that results in diminishment of femoral perfusion and ends up with FHO. The insufficient knowledge on molecular background and progression pattern of FHO and the restrictions in obtaining human samples bring out the need for a small animal trauma model to research FHO aetiology. Hence, this study aims to develop a mouse trauma model to elucidate the molecular mechanisms behind FHO. Method. Left femoral head was dislocated from the hip joint, ligamentum teres was cut, and a slight circular incision was done around the femoral neck of 8-week-old male C57BL/6J mice to disrupt the blood supply to femoral head. Right hip joint was left unoperated as control. Animals (n=5 per time point) were sacrificed on 2-3-4-6-8-10-12 weeks, and ex-vivo µCT was taken to assess bone structural parameters. Haematoxylin/eosin (HE)- and immunohistochemical-staining (IHCS) for CD31 and EMCN were done to observe histology and marrow-specific H-type vascular structures, respectively. Result. μCT assessment showed trabecular bone loss and decreased BV/TV from 2 to 8 weeks in FHO side. HE staining displayed the increased number of empty lacunae was observed in FHO side as early as 24h after operation. By 4. th. week, IHCS results displayed the invasion of the epiphyseal plate by H-type blood vessels in FHO side, while the epiphyseal plate was observed intact in control side. Also, by 6. th. week the HE-staining showed the presence of bone marrow necrosis and bone fat accumulation in FHO side. Conclusion. Trabecular bone loss, increased number of empty lacunae, bone fat imbalance and bone marrow necrosis are reported as the signs of osteonecrosis. Thus, our results are coherent with the literature and indicated that we were able to effectively generate a trauma model for FHO in mice for the first time in literature


Bone & Joint Research
Vol. 3, Issue 7 | Pages 230 - 235
1 Jul 2014
van der Jagt OP van der Linden JC Waarsing JH Verhaar JAN Weinans H

Objectives

Electromagnetic fields (EMF) are widely used in musculoskeletal disorders. There are indications that EMF might also be effective in the treatment of osteoporosis. To justify clinical follow-up experiments, we examined the effects of EMF on bone micro-architectural changes in osteoporotic and healthy rats. Moreover, we tested the effects of EMF on fracture healing.

Methods

EMF (20 Gauss) was examined in rats (aged 20 weeks), which underwent an ovariectomy (OVX; n = 8) or sham-ovariectomy (sham-OVX; n = 8). As a putative positive control, all rats received bilateral fibular osteotomies to examine the effects on fracture healing. Treatment was applied to one proximal lower leg (three hours a day, five days a week); the lower leg was not treated and served as a control. Bone architectural changes of the proximal tibia and bone formation around the osteotomy were evaluated using in vivo microCT scans at start of treatment and after three and six weeks.


Bone & Joint Research
Vol. 10, Issue 11 | Pages 714 - 722
1 Nov 2021
Qi W Feng X Zhang T Wu H Fang C Leung F

Aims. To fully verify the reliability and reproducibility of an experimental method in generating standardized micromotion for the rat femur fracture model. Methods. A modularized experimental device has been developed that allows rat models to be used instead of large animal models, with the aim of reducing systematic errors and time and money constraints on grouping. The bench test was used to determine the difference between the measured and set values of the micromotion produced by this device under different simulated loading weights. The displacement of the fixator under different loading conditions was measured by compression tests, which was used to simulate the unexpected micromotion caused by the rat’s ambulation. In vivo preliminary experiments with a small sample size were used to test the feasibility and effectiveness of the whole experimental scheme and surgical scheme. Results. The bench test showed that a weight loading < 500 g did not affect the operation of experimental device. The compression test demonstrated that the stiffness of the device was sufficient to keep the uncontrollable motion between fracture ends, resulting from the rat’s daily activities, within 1% strain. In vivo results on 15 rats prove that the device works reliably, without overburdening the experimental animals, and provides standardized micromotion reproductively at the fracture site according to the set parameters. Conclusion. Our device was able to investigate the effect of micromotion parameters on fracture healing by generating standardized micromotion to small animal models. Cite this article: Bone Joint Res 2021;10(11):714–722


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 147 - 147
1 Jul 2020
Godbout C Nauth A Schemitsch EH Fung B Lad H Watts E Desjardins S Cheung KLT
Full Access

The Masquelet or induced membrane technique (IMT) is a two-stage surgical procedure used for the treatment of segmental bone defects. In this technique, the defect is first filled with a polymethyl methacrylate (PMMA) spacer, which triggers the formation of a membrane that will encapsulate the defect. During the second surgery, the spacer is carefully removed and replaced by autologous bone graft while preserving the membrane. This membrane is vascularized, contains growth factors, and provides mechanical stability to the graft, all of which are assumed to prevent graft resorption and promote bone healing. The technique is gaining in popularity and several variations have been introduced in the clinical practice. For instance, orthopaedic surgeons now often include antibiotics in the spacer to treat or prevent infection. However, the consequences of this approach on the properties of the induce membrane are not fully understood. Accordingly, in a small animal model, this study aimed to determine the impact on the induced membrane of impregnating spacers with antibiotics frequently used in the IMT. We surgically created a five-mm segmental defect in the right femur of 25 adult male Sprague Dawley rats. The bone was stabilized with a plate and screws before filling the defect with a PMMA spacer. Animals were divided into five equal groups according to the type and dose of antibiotics impregnated in the spacer: A) no antibiotic (control), B) low-dose tobramycin (1.2 g/40 g of PMMA), C) low-dose vancomycin (1 g/40 g of PMMA), D) high-dose tobramycin (3.6 g/40 g of PMMA), E) high-dose vancomycin (3 g/40 g of PMMA). The animals were euthanized three weeks after surgery and the induced membranes were collected and divided for analysis. We assessed the expression of selected genes (Alpl, Ctgf, Runx2, Tgfb1, Vegfa) within the membrane by quantitative real-time PCR. Moreover, frozen sections of the specimens were used to quantify vascularity by immunohistochemistry (CD31 antigen), proliferative cells by immunofluorescence (Ki-67 antigen), and membrane thickness. Microscopic images of the entire tissue sections were taken and analyzed using FIJI software. Finally, we measured the concentration of vascular endothelial growth factor (VEGF) in the membranes by ELISA. No significant difference was found among the groups regarding the expression of genes related to osteogenesis (Alpl, Runx2), angiogenesis (Vegfa), or synthesis of extracellular matrix (Ctgf, Tgfb1) (n = four or five). Similarly, the density of proliferative cells and blood vessels within the membrane, as well as the membrane thickness, did not vary substantially between the control, low-dose, or high-dose antibiotic groups (n = four or five). The concentration of VEGF was also not significantly influenced by the treatment received (n = four or five). The addition of tobramycin or vancomycin to the spacer, at the defined low and high doses, does not significantly alter the bioactive characteristics of the membrane. These results suggest that orthopaedic surgeons could use antibiotic-impregnated spacers for the IMT without compromising the induced membrane and potentially bone healing


Bone & Joint Research
Vol. 1, Issue 11 | Pages 289 - 296
1 Nov 2012
Savaridas T Wallace RJ Muir AY Salter DM Simpson AHRW

Objectives. Small animal models of fracture repair primarily investigate indirect fracture healing via external callus formation. We present the first described rat model of direct fracture healing. Methods. A rat tibial osteotomy was created and fixed with compression plating similar to that used in patients. The procedure was evaluated in 15 cadaver rats and then in vivo in ten Sprague-Dawley rats. Controls had osteotomies stabilised with a uniaxial external fixator that used the same surgical approach and relied on the same number and diameter of screw holes in bone. Results. Fracture healing occurred without evidence of external callus on plain radiographs. At six weeks after fracture fixation, the mean stress at failure in a four-point bending test was 24.65 N/mm. 2. (. sd. 6.15). Histology revealed ‘cutting-cones’ traversing the fracture site. In controls where a uniaxial external fixator was used, bone healing occurred via external callus formation. Conclusions. A simple, reproducible model of direct fracture healing in rat tibia that mimics clinical practice has been developed for use in future studies of direct fracture healing


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 6 - 6
1 Oct 2018
Naudie DD Paish AD Nikolov HN Chmiel T El-Warrak AO Welch ID Teeter MG Holdsworth DW
Full Access

Introduction. As new innovations are developed to improve the longevity of joint replacement components, preclinical testing is necessary in the early stages of research into areas such as osseointegration, metal-cartilage wear and periprosthetic joint infection (PJI). Large-animal studies that test load-bearing components are expensive, however, requiring that animals be housed in special facilities that are not available at all institutions. Comparably, small animal models, such as the rat, offer several advantages including lower cost. Load-bearing implants remain difficult to manufacture via traditional methods in the sizes required for small-animal testing. Recent advances in additive manufacturing (3D metal-printing) have allowed for the creation of miniature joint replacement components in a variety of medical-grade metal alloys. The objective of this work is to create and optimize an image-based 3D-printed rat hip implant system that will allow in vivo testing of functional implant properties in a rat model. Methods. A database of n=25 previously-acquired, 154μm micro-CT volumes (eXplore Locus Ultra, GE Medical) of male Sprague-Dawley rats (390–610g) were analyzed to obtain spatial and angular relationships between several anatomical features of the proximal rat femora. Mean measurements were used to guide the creation of a femoral implant template in computer-aided design software (Solidworks, Dassault Systemes). Several different variations were created, including collarless and collared designs, in a range of sizes to accommodate rats of various weights. Initial prototypes were 3D-printed 316L stainless steel with subsequent iterations printed in Ti6Al4V titanium and F75 cobalt-chrome. Implants were post-processed via sandblasting, hand-polishing, ultrasonic bath, and sterilization in an autoclave. Innate surface texturing was left on manufactured stems to promote osseointegration. Surgical implantation was performed in three live Sprague-Dawley rats (900g, 500g, 750g) with preservation of muscle attachments to the greater trochanter. Micro-CT imaging and X-ray fluoroscopy were performed post-operatively on each animal at 1 day, and 1, 3, 9 and 12 weeks to evaluate gait and component positioning. Results. Implantation of components was successful and each animal was observed to ambulate on its affected limb immediately following recovery from surgery. The 900g rat, given a collarless 316L stainless steel component, was kept for 11 months post-implantation before succumbing to old age. Micro-CT and fluoroscopic findings revealed no evidence of implant subsidence. The 500g animal, given a collarless 316L stainless steel implant, showed evidence of implant subsidence at 3 weeks, with full subsidence and hip dislocation at 12 weeks. The 750g rat, given a collared F75 cobalt-chrome implant, was observed ambulating on its affected limb, but experienced implant rotation and failure at 9 weeks. Conclusions. We report the first hip hemi-arthroplasty in a rat using a 3D-printed metal implant. This model aims to provide a low-cost platform for studying osseointegration, metal-cartilage interactions, and PJI using a functional, loaded implant. Efforts to further optimize the surgical approach will be made to reduce early implant loosening. A study with larger sample sizes is needed to determine if implants can be installed repeatedly, without complications, before the utility of this approach can be validated. Future work will include surface preparations on implant stems, with micro-CT to longitudinally track changes at the bone-metal interface, and gait analysis on a radiolucent treadmill to quantify post-operative kinematics


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 522 - 529
1 Mar 2021
Nichol T Callaghan J Townsend R Stockley I Hatton PV Le Maitre C Smith TJ Akid R

Aims. The aim of this study was to develop a single-layer hybrid organic-inorganic sol-gel coating that is capable of a controlled antibiotic release for cementless hydroxyapatite (HA)-coated titanium orthopaedic prostheses. Methods. Coatings containing gentamicin at a concentration of 1.25% weight/volume (wt/vol), similar to that found in commercially available antibiotic-loaded bone cement, were prepared and tested in the laboratory for: kinetics of antibiotic release; activity against planktonic and biofilm bacterial cultures; biocompatibility with cultured mammalian cells; and physical bonding to the material (n = 3 in all tests). The sol-gel coatings and controls were then tested in vivo in a small animal healing model (four materials tested; n = 6 per material), and applied to the surface of commercially pure HA-coated titanium rods. Results. The coating released gentamicin at > 10 × minimum inhibitory concentration (MIC) for sensitive staphylococcal strains within one hour thereby potentially giving effective prophylaxis for arthroplasty surgery, and showed > 99% elution of the antibiotic within the coating after 48 hours. There was total eradication of both planktonic bacteria and established bacterial biofilms of a panel of clinically relevant staphylococci. Mesenchymal stem cells adhered to the coated surfaces and differentiated towards osteoblasts, depositing calcium and expressing the bone marker protein, osteopontin. In the in vivo small animal bone healing model, the antibiotic sol-gel coated titanium (Ti)/HA rod led to osseointegration equivalent to that of the conventional HA-coated surface. Conclusion. In this study we report a new sol-gel technology that can release gentamicin from a bioceramic-coated cementless arthroplasty material. In vitro, local gentamicin levels are in excess of what can be achieved by antibiotic-loaded bone cement. In vivo, bone healing in an animal model is not impaired. This, thus, represents a biomaterial modification that may have the potential to protect at-risk patients from implant-related deep infection. Cite this article: Bone Joint J 2021;103-B(3):522–529


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 15
1 Mar 2002
Brooks R Rushton M Wimhurst J Rushton N
Full Access

This study investigated the effects of wear particles, produced from a number of implant materials, at the bone-implant interface using a small animal model. Particles were prepared from metal, ceramic and polymer replacement joint components or implant grade stock by grinding the materials against a diamond embedded grinding pad. The mean diameter of the particles ranged from 1.5mm to 3.2mm. Sterilised particles were suspended in sterile saline containing 2% v/v male Sprague-Dawley serum at a concentration of 109 particles per ml. Seventy-two male Sprague-Dawley rats were assigned to twelve groups of six animals. A ceramic pin was inserted into the right tibia of each animal. Six groups were assigned a particle type with one group acting as vehicle control. 100ml of particle suspension or vehicle was injected into each knee joint at 8, 10 and 12 weeks following implantation and the animals were killed 2 weeks later. Of the remaining five groups, four were assigned a particle type and one was the vehicle control. These animals were injected with 100ml of particle suspension or vehicle at 20, 22 and 24 weeks following pin implantation and were killed 2 weeks later. The tibia and femora were removed, disarticulated and processed for histology. The total gap between pin and bone, including fibrous tissue, was measured. Specimens showed no signs of infection either clinically or in the histopathology. All materials tested produced lesions at the bone-implant interface. A significant difference was seen between metal injected vs. vehicle control animals and aluminium oxide injected vs. vehicle controls. Particles of stainless steel produced the greatest response and this finding may have implications for the use of metal on metal articulations aimed at eliminating polyethylene wear


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 97 - 97
1 Mar 2009
Egermann M Ito K Hofstetter W Richards P
Full Access

Introduction: Osteoporosis, a major public health burden, is associated with increased fracture risk. Fracture healing in osteoporosis is altered with reduced callus formation and impaired biomechanical properties of newly formed bone leading to high risk of fixation failure. Experimental data have shown decreased healing potential in aged animals and in animal models of post-menopausal bone loss. It is unclear whether fracture healing is similarly impaired in senile osteoporosis. The objective of this study is to investigate fracture healing in a small animal model of senile osteoporosis, senescence-accelerated mouse prone 6 (SAMP6). Materials & Methods: A mid-femur osteotomy was created in SAMP6-mice (n=24) and senescence-resistant inbred strains (SAMR1) (n=24) were used as controls. The osteotomy was rigidly fixed using a newly developed screw-plate-implant (MouseFix). Fracture healing was evaluated at 7, 14, 28 and 42 days after surgery using micro-CT and histomorphometry. Biochemical marker for bone formation (osteocalcin) and bone resorption (TRAP5b) were evaluated from serum samples. MSC were extracted from the femurs of mice and cultured in vitro and differentiated into either osteoblasts or adipocytes using standard induction media. Results: Studies carried out in vitro confirmed that MSC isolated from the bone marrow of SAMP6 mice had a reduced tendency to differentiate toward the osteoblast cell lineage as previously reported in human osteoporotic patients. Although osteoblastogenesis was clearly impaired, the formation of new bone in SAMP6 mice was comparable to that observed in SAMR1 mice. Similar results were found for histomorphometry data analyzing the degree of bone mineralisation. Interestingly, osteocalcin levels were significantly increased in serum samples from osteoporotic mice at day 7 and 14 following fracture. Discussion: The data presented here indicates that fracture healing proceeds normally in a mouse model for senile osteoporosis. This finding supports the clinical observation that although fracture fixation is difficult in osteoporosis, healing potential seems to be unchanged. MSC from osteoporotic patients as wells as from SAMP6-mice show reduced proliferation rate together with adipogenic rather than osteogenic differentiation pattern. However, decreased cell dynamics seems not to influence diaphyseal fracture healing. Other sources of MSC other than bone marrow-derived MSC may therefore be pivotal in determining the outcome of intramembranous bone repair in both normal and osteoporotic bone


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 77 - 77
1 Mar 2009
Kaspar K Matziolis G Kasper G Bail H Duda G
Full Access

Introduction: Currently used small animal models of a critical size defect do not sufficiently simulate the biologically unreactive situation in an atrophic non-union. Furthermore, models using intramedullary nails are of little, and poorly standardised, biomechanical stability. This is a characteristic known to promote callus formation though, rather leading to a hypertrophic non-union. The aim of this study was to establish an atrophic non-union model in the rat femur under well defined biomechanical conditions and with minimised interactions between the processes in the healing zone and the implant by using external fixation. MATERIALS AND METHODS: 80 male Sprague Dawley rats were randomly divided into two groups (non-union vs. control). All animals received an osteotomy (app. 0.5 mm gap) of the left femur, stabilised with a custom made external fixator. In the non-union group the periosteum was cauterised 2mm distal and proximal of the osteotomy, and the bone marrow was removed. X-rays were performed once weekly. Animals were sacrificed at 14 or 56 days post-operation. At both time points the femurs of 16 animals of each group underwent histological/histomorphometrical and immunhis-tochemical analyses (PMMA or paraffin embedding). Additionally at 56 days 8 animals of each group were tested biomechanically. The maximum torsional failure moment and the torsional stiffness were determined in relation to the intact femur. Post-mortem x-rays were evaluated in a descriptive manner. RESULTS: At 14 days the histology and radiology showed considerable mineralised periosteal callus in the control group, while the non-union group only showed very little periosteal callus, distant to the osteotomy. At 56 days the control group was completely, or at least partially, bridged by mineralised callus. The non-union group did not show a bridging of the osteotomy gap in any of the animals, moreover the bone ends were resorbed and the gap widened. The relative mean torsional stiffness was significantly larger (p< 0.001) in the control group compared to the non-union group (136.2±34.5% vs. 2.3±1.2%). In the non-union group no maximal torsional failure moment could be detected for the osteotomised femurs. In the control group it was 134.2±79.1%, relative to the intact femur. DISCUSSION: The cauterisation of the periosteum and the removal of the bone marrow, in combination with a high stiffness of the external fixator may create an atrophic non-union under well defined biomechanical conditions and with minimised interactions between the healing zone and the implant. This model will allow better standardised investigations on the subject of atrophic non-unions


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 4 - 5
1 Jan 2003
Reed A Joyner C Isefuku S Brownlow H Simpson A
Full Access

Atrophic non-unions are usually attributed to impaired blood supply but the events that lead to atrophic non-union remain poorly understood. Recent studies. 1,. 2. have shown that vascularity is not reduced in established non-unions but these studies have not examined vascularity at an early stage. The aims of this study were to: 1) develop and validate a clinically relevant small animal model of atrophic non-union and 2) test the hypothesis that the vessel density of atrophic non-unions reaches that of normal healing bones but at a later time point. Twenty eight adult female Wistar rats underwent application of a novel circular frame external fixator to the right tibia under general anaesthesia. The fixator construct was standardised, with eight needles that were drilled through the skin into the proximal and distal metaphyses of the tibia. An osteotomy was performed with a 1mm burr under irrigation. The periosteum was removed on 14 of the 28 animals using a scalpel and the intramedullary canal was curetted. Both insults were performed proximally and distally for a distance equivalent to 1 diameter of the tibia. A 1mm gap was introduced at the osteotomy site and the wound was closed. Once the animal had recovered it was allowed unrestricted weight bearing. Anteroposterior X rays were performed every 2 weeks. Animals were killed at 1, 3, 8 and 16 weeks. Callus areas were measured from X rays using an image analysis system. The average callus area was calculated for each rat every 2 weeks as an indicator of callus production. Specimens were fixed, decalcified, embedded in paraffin wax and 6 ìm sections were stained with H& E. Vascularity was assessed immunohistochemically with monoclonal antibody against smooth muscle actin. The total number of blood vessels in the interfragmentary gap was counted. At 8 and 16 weeks post-osteotomy all animals where stripping and curetting had been performed went on to an atrophic non-union. All animals where this was not performed went on to unite successfully. Histological observations support these radiological findings. Significantly less callus formed in the non-unions than in those that united. There were significantly fewer vessels in the non-unions at week 1 compared to the controls but, by 8 weeks the blood vessel density in the established atrophic non-unions had reached the same level as the vessel density during normal healing. An atrophic non-union model that closely resembles the clinical situation has been developed and validated in rats. The results support the hypothesis that the number of vessels in atrophic non-unions reaches the same level as in those that unite but at a later time point. It is concluded that diminished vessel density within the first 3 weeks may prevent fractures from uniting


Bone & Joint Research
Vol. 12, Issue 3 | Pages 212 - 218
9 Mar 2023
Buchalter DB Kirby DJ Anil U Konda SR Leucht P

Aims

Glucose-insulin-potassium (GIK) is protective following cardiac myocyte ischaemia-reperfusion (IR) injury, however the role of GIK in protecting skeletal muscle from IR injury has not been evaluated. Given the similar mechanisms by which cardiac and skeletal muscle sustain an IR injury, we hypothesized that GIK would similarly protect skeletal muscle viability.

Methods

A total of 20 C57BL/6 male mice (10 control, 10 GIK) sustained a hindlimb IR injury using a 2.5-hour rubber band tourniquet. Immediately prior to tourniquet placement, a subcutaneous osmotic pump was placed which infused control mice with saline (0.9% sodium chloride) and treated mice with GIK (40% glucose, 50 U/l insulin, 80 mEq/L KCl, pH 4.5) at a rate of 16 µl/hr for 26.5 hours. At 24 hours following tourniquet removal, bilateral (tourniqueted and non-tourniqueted) gastrocnemius muscles were triphenyltetrazolium chloride (TTC)-stained to quantify percentage muscle viability. Bilateral peroneal muscles were used for gene expression analysis, serum creatinine and creatine kinase activity were measured, and a validated murine ethogram was used to quantify pain before euthanasia.


Bone & Joint Research
Vol. 13, Issue 8 | Pages 383 - 391
2 Aug 2024
Mannala GK Rupp M Walter N Youf R Bärtl S Riool M Alt V

Aims

Bacteriophages infect, replicate inside bacteria, and are released from the host through lysis. Here, we evaluate the effects of repetitive doses of the Staphylococcus aureus phage 191219 and gentamicin against haematogenous and early-stage biofilm implant-related infections in Galleria mellonella.

Methods

For the haematogenous infection, G. mellonella larvae were implanted with a Kirschner wire (K-wire), infected with S. aureus, and subsequently phages and/or gentamicin were administered. For the early-stage biofilm implant infection, the K-wires were pre-incubated with S. aureus suspension before implantation. After 24 hours, the larvae received phages and/or gentamicin. In both models, the larvae also received daily doses of phages and/or gentamicin for up to five days. The effect was determined by survival analysis for five days and quantitative culture of bacteria after two days of repetitive doses.


Bone & Joint Research
Vol. 12, Issue 1 | Pages 58 - 71
17 Jan 2023
Dagneaux L Limberg AK Owen AR Bettencourt JW Dudakovic A Bayram B Gades NM Sanchez-Sotelo J Berry DJ van Wijnen A Morrey ME Abdel MP

Aims

As has been shown in larger animal models, knee immobilization can lead to arthrofibrotic phenotypes. Our study included 168 C57BL/6J female mice, with 24 serving as controls, and 144 undergoing a knee procedure to induce a contracture without osteoarthritis (OA).

Methods

Experimental knees were immobilized for either four weeks (72 mice) or eight weeks (72 mice), followed by a remobilization period of zero weeks (24 mice), two weeks (24 mice), or four weeks (24 mice) after suture removal. Half of the experimental knees also received an intra-articular injury. Biomechanical data were collected to measure passive extension angle (PEA). Histological data measuring area and thickness of posterior and anterior knee capsules were collected from knee sections.


Bone & Joint Research
Vol. 11, Issue 7 | Pages 503 - 512
25 Jul 2022
Wu Y Shao Y Xie D Pan J Chen H Yao J Liang J Ke H Cai D Zeng C

Aims

To verify whether secretory leucocyte protease inhibitor (SLPI) can promote early tendon-to-bone healing after anterior cruciate ligament (ACL) reconstruction.

Methods

In vitro: the mobility of the rat bone mesenchymal stem cells (BMSCs) treated with SLPI was evaluated by scratch assay. Then the expression levels of osteogenic differentiation-related genes were analyzed by real-time quantitative PCR (qPCR) to determine the osteogenic effect of SLPI on BMSCs. In vivo: a rat model of ACL reconstruction was used to verify the effect of SLPI on tendon-to-bone healing. All the animals of the SLPI group and the negative control (NC) group were euthanized for histological evaluation, micro-CT scanning, and biomechanical testing.


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims

Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model.

Methods

A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.