header advert
Results 1 - 15 of 15
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 63 - 63
17 Apr 2023
MacLeod A Dal Fabbro G Grassi A Belvedere C Nervuti G Casonato A Leardini A Gil H Zaffagnini S
Full Access

High tibial osteotomy (HTO) is a joint preserving alternative to knee replacement for medial tibiofemoral osteoarthritis in younger, more active patients. The procedure is technically challenging and limited also by ‘one size fits all’ plates which can result in patient discomfort necessitating plate removal. This clinical trial evaluated A novel custom-made HTO system – TOKA (3D Metal Printing LTD, Bath, UK) for accuracy of osteotomy correction and improvements in clinical outcome scores. The investigation was a single-arm single-centre prospective clinical trial (IRCCS Istituto Ortopedico Rizzoli; ClinicalTrials.gov NCT04574570), with recruitment of 25 patients (19M/6F; average age: 54.4 years; average BMI: 26.8), all of whom received the TOKA HTO 3D planning and surgery. All patients were predominantly diagnosed with isolated medial knee osteoarthritis and with a varus deformity under 20°. Patients were CT scanned pre- and post-operatively for 3D virtual planning and correctional assessment. All surgeries were performed by the lead clinical investigator – a consultant knee surgeon with a specialist interest in and clinical experience of HTO. On average, Knee Society Scores (KSS) improved significantly (p<0.001) by 27.6, 31.2 and 37.2 percentage points respectively by 3-, 6- and 12-months post-surgery respectively. Other measures assessed during the study (KOOS, EQ5D) produced similar increases. Our early experience using custom implants is extremely promising. We believe the reduced profile of the plate, as well as the reduced invasiveness and ease of surgery contributed to faster patient recovery, and improved outcome scores compared to conventional techniques. These clinical outcome results compare very favourably other case-series with published KOOS scores using different devices


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 56 - 56
1 Dec 2022
Bishop E Kuntze G Clark M Ronsky J
Full Access

Individuals with multi-compartment knee osteoarthritis (KOA) frequently experience challenges in activities of daily living (ADL) such as stair ambulation. The Levitation “Tri-Compartment Offloader” (TCO) knee brace was designed to reduce pain in individuals with multicompartment KOA. This brace uses novel spring technology to reduce tibiofemoral and patellofemoral forces via reduced quadriceps forces. Information on brace utility during stair ambulation is limited. This study evaluated the effect of the TCO during stair descent in patients with multicompartment KOA by assessing knee flexion moments (KFM), quadriceps activity and pain. Nine participants (6 male, age 61.4±8.1 yrs; BMI 30.4±4.0 kg/m2) were tested following informed consent. Participants had medial tibiofemoral and patellofemoral OA (Kellgren-Lawrence grades two to four) diagnosed by an orthopaedic surgeon. Joint kinetics and muscle activity were evaluated during stair descent to compare three bracing conditions: 1) without brace (OFF); 2) brace in low power (LOW); and 3) brace in high power (HIGH). The brace spring engages from 60° to 120° and 15° to 120° knee flexion in LOW and HIGH, respectively. Individual brace size and fit were adjusted by a trained researcher. Participants performed three trials of step-over-step stair descent for each bracing condition. Three-dimensional kinematics were acquired using an 8-camera motion capture system. Forty-one spherical reflective markers were attached to the skin (on each leg and pelvis segment) and 8 markers on the brace. Ground reaction forces and surface EMG from the vastus medialis (VM) and vastus lateralis (VL) were collected for the braced leg. Participants rated knee pain intensity performing the task following each bracing condition on a 10cm Visual Analog Scale ranging from “no pain” (0) to “worst imaginable pain” (100). Resultant brace and knee flexion angles and KFM were analysed during stair contact for the braced leg. The brace moment was determined using brace torque-angle curves and was subtracted from the calculated KFM. Resultant moments were normalized to bodyweight and height. Peak KFMs were calculated for the loading response (Peak1) and push-off (Peak2) phases of support. EMG signals were normalized and analysed during stair contact using wavelet analysis. Signal intensities were summed across wavelets and time to determine muscle power. Results were averaged across all 3 trials for each participant. Paired T-tests were used to determine differences between bracing conditions with a Bonferroni adjustment for multiple comparisons (α=0.025). Peak KFM was significantly lower compared to OFF with the brace worn in HIGH during the push-off phase (p Table 1: Average peak knee flexion moments, quadriceps muscle power and knee pain during stair descent in 3 brace conditions (n=9). Quadriceps activity, knee flexion moments and pain were significantly reduced with TCO brace wear during stair descent in KOA patients. These findings suggest that the TCO assists the quadriceps to reduce KFM and knee pain during stair descent. This is the first biomechanical evidence to support use of the TCO to reduce pain during an ADL that produces especially high knee forces and flexion moments. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 27 - 27
1 Nov 2016
Hofmann A
Full Access

The anatomic resection approach is based on the patient's unique anatomy adjusting for worn cartilage or bone loss. The femoral component is aligned around the primary transverse distal femoral axis around which the tibia follows a multi-radius of curvature. The tibia cut is made according to the patient's native anatomy adjusting for worn cartilage and bone loss, and applying an anatomic amount of tibial slope. This technique minimises the need for ligamentous releases to a large degree preserving the competence of the patient's soft tissue. Ligament and capsular releases can be used in difficult cases. Adjustments for the natural varus up to 3 degrees and slope of the tibial bone cut (3 – 10 degrees) further aids in knee balancing. The final alignment may not agree with a neutral hip-knee-ankle mechanical alignment on full length standing x-rays, leaving varus knees in slight varus, and valgus legs in neutral. Since little or no balance is required, this operation can be performed efficiently. Personalise the reconstruction and alignment as much as possible for each patient. The traditional “one size fits all” method where all patients have a center hip, knee, and ankle alignment needs to be reevaluated and reserved for the valgus leg


Bone & Joint Open
Vol. 4, Issue 11 | Pages 899 - 905
24 Nov 2023
Orfanos G Nantha Kumar N Redfern D Burston B Banerjee R Thomas G

Aims

We aim to evaluate the usefulness of postoperative blood tests by investigating the incidence of abnormal results following total joint replacement (TJR), as well as identifying preoperative risk factors for abnormal blood test results postoperatively, especially pertaining to anaemia and acute kidney injury (AKI).

Methods

This is a retrospective cohort study of patients who had elective TJR between January and December 2019 at a tertiary centre. Data gathered included age at time of surgery, sex, BMI, American Society of Anesthesiologists (ASA) grade, preoperative and postoperative laboratory test results, haemoglobin (Hgb), white blood count (WBC), haematocrit (Hct), platelets (Plts), sodium (Na+), potassium (K+), creatinine (Cr), estimated glomerular filtration rate (eGFR), and Ferritin (ug/l). Abnormal blood tests, AKI, electrolyte imbalance, anaemia, transfusion, reoperation, and readmission within one year were reported.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 496 - 506
5 Jul 2023
Theunissen WWES Van der Steen MC Van Veen MR Van Douveren FQMP Witlox MA Tolk JJ

Aims

The aim of this study was to identify the information topics that should be addressed according to the parents of children with developmental dysplasia of the hip (DDH) in the diagnostic and treatment phase during the first year of life. Second, we explored parental recommendations to further optimize the information provision in DDH care.

Methods

A qualitative study with semi-structured interviews was conducted between September and December 2020. A purposive sample of parents of children aged younger than one year, who were treated for DDH with a Pavlik harness, were interviewed until data saturation was achieved. A total of 20 interviews with 22 parents were conducted. Interviews were audio recorded, transcribed verbatim, independently reviewed, and coded into categories and themes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVII | Pages 20 - 20
1 May 2012
Hak P Jones M
Full Access

Background. Many Accident and Emergency units employ a “one size fits all” policy with regard to referring patients with musculoskeletal injury for further review in fracture clinic. This may result in inappropriate timings of review in the clinic wasting patient time, clinic time and hospital resources. Aim. Our firm employs a rapid review of all radiographs and A&E notes of all musculoskeletal injury patients referred to our fracture clinic on a weekly basis. We aimed to investigate the impact this review has on the running of our clinic and what benefits were gained. Patients and Methods. Over a three month period all the rapid trauma review meetings were audited with respect to time taken; number of referrals; outcome of referral and staff members present. During this time an audit of the number of patients reviewed in fracture clinic by the Consultant orthopaedic surgeon was also undertaken to allow the average time taken for review of a patient in the clinic to be established. Results and Discussion. Over the three month period 117 patients were reviewed with 44(38%) being given a later appointment; 6(5%) being given an earlier appointment; 8(7%) being discharged to general practice or physiotherapy and 4(3%) being referred to a different clinic. Man time taken to review was 2.4minutes per patient. Mean time for review in fracture clinic was 12.6minutes. Taking the changes to later appointment, discharges and changes to different clinic to be inappropriate referrals, 4.7 occurred per review meeting. This equated to a mean time saved per fracture clinic of 60.6 minutes. Conclusion. This data supports the use of a rapid trauma review meeting to ensure appropriate timing of review of musculoskeletal injury patients. It saves time wasted on inappropriate reviews, saves patient dissatisfaction with being seen unnecessarily and allows patients who should be reviewed more promptly to be identified and reviewed appropriately


Bone & Joint Research
Vol. 11, Issue 4 | Pages 189 - 199
13 Apr 2022
Yang Y Li Y Pan Q Bai S Wang H Pan X Ling K Li G

Aims

Treatment for delayed wound healing resulting from peripheral vascular diseases and diabetic foot ulcers remains a challenge. A novel surgical technique named ‘tibial cortex transverse transport’ (TTT) has been developed for treating peripheral ischaemia, with encouraging clinical effects. However, its underlying mechanisms remain unclear. In the present study, we explored the potential biological mechanisms of TTT surgery using various techniques in a rat TTT animal model.

Methods

A novel rat model of TTT was established with a designed external fixator, and effects on wound healing were investigated. Laser speckle perfusion imaging, vessel perfusion, histology, and immunohistochemistry were used to evaluate the wound healing processes.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 152 - 159
22 May 2020
Oommen AT Chandy VJ Jeyaraj C Kandagaddala M Hariharan TD Arun Shankar A Poonnoose PM Korula RJ

Aims

Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips.

Methods

In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 140 - 140
1 Sep 2012
Marquez A Patel R Stulberg SD
Full Access

Introduction. Many uncemented femoral implant designs have had successful outcomes in total hip arthroplasty (THA). Different uncemented stem designs achieve initial and long term stability through shape, size, coating and fit. There is increasing emphasis on bone preservation, particularly in younger and more active patients. The desire to optimize load transfer has led to the development of short stems that seek to achieve fixation in the proximal femur. Short stems designed to achieve stability by engaging the metaphysis or the proximal femoral necks are currently in clinical use. The purpose of this study was to examine the extent to which five stems designed to achieve proximal fixation contact the bone in the proximal femur. Using three-dimensional CT models of 30 femurs, we assessed the fit, fill and contact of each of the five different implants. Methods. Using three-dimensional computerized templating software designed to navigate robotic surgery, pre-operative CT scans of 30 patients were analyzed. Each of five femoral implant designs (TRILOCK, ARC, ABGII, CITATION, ACCOLADE) was then optimized for size and fit based on manufacturer technique guide and design rationale. The proximal femoral metaphysis was divided into four zones in the axial plane. Five contact points were determined on the frontal plane using anatomical landmarks. Each zone was assessed for cortical contact and fill of the bone-implant interface. We graded contact from 1 to 5, with 5 being 100% contact. Results. In the 150 different templates analyzed significant variability existed in contact areas of the proximal femur depending on implant design and femoral morphology. High femoral neck resection design (ARC) had the greatest contact area in the most proximal zones (Figure 1). The ABG II and Trilock stems had comparable contact in the antero-medial zones, while the ABG II had greater fill in the sagittal plane (Figures 2 & 3). The Trilock was the only stem that consistently achieved lateral cortical contact at the distal landmarks. All stems showed a pattern of mostly posteromedial contact proximally and mostly anteromedial distally. Discussion. To our knowledge, this is the first study to examine the contact points of metaphyseal engaging stems in the proximal femur. By directly comparing implant contact points in the same femur we found significant variability in the extent of fit, fill and contact of the metaphysis. These differences in proximal femoral contact are like to have implications for fixation in bone of varying quality and for long term proximal bone remodeling


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 452 - 452
1 Nov 2011
Scuderi G
Full Access

Surgical instrumentation for total knee arthroplasty has improved the accuracy, reproducibility and reliability of the procedure. In recent years, minimally invasive surgery introduced instrumentation that was reduced in size to fit within the smaller operative field; with this move the impact and influence of technology became proportionately larger. The introduction of computer navigation is an attempt to improve the surgeon’s visibility in a limited operative field, improve the position of the resection guides, and ultimately the position of the final components. While it may be appealing to rely on computer navigation to perform a TKA, it is not artificial intelligence and does not make any of the surgical decisions. The procedure still is surgeon directed with navigation serving as a tool of confirmation with the potential for improvements in surgical accuracy and reproducibility. The accuracy of TKA has always been dependent upon the surgeon’s judgment, experience, ability to integrate images, utilize pre-operative radiographs, knowledge of anatomic landmarks, knowledge of knee kinematics, and hand eye co-ordination. Recent advances in medical imaging, computer vision and patient specific instrumentation have provided enabling technologies, which in a synergistic manner optimize the accurate performance of the surgery. The successful use of this technology requires that it not replace the surgeon, but support the surgeon with enhanced intra-operative feedback, integration of pre-operative and intra-operative information, and visual dexterity during the procedure. In developing smart tools or robotic systems, the technology must be: safe; accurate; compatible with the operative field in size and shape, as well be able to be sterilized; and must show measurable benefits such as reduced operative time, reduced surgical trauma and improved clinical outcomes. Advocates believe this is attainable and robotic assisted TKA can achieve levels of accuracy, precision and safety not accomplished by computer assisted surgery. Smart instruments and robotic surgery are helping us take the next step into the operating room of the future. The role of robots in the operating room has the potential to increase as technology improves and appropriate applications are defined. Joint replacement arthroplasty may benefit the most due to the need for high precision in placing instruments, aligning the limb and implanting components. In addition, this technology will reduce the number of instruments needed for the procedure potentially further improving efficiency in the operating room. As technology advances, robots may be commonplace in the surgical theater and potentially transform the way total knee arthroplasty is done in the future. Robotic surgery and smart tools are new innovative technologies and it will remain to be seen if history will look on its development as a profound improvement in surgical technique or a bump on the road to something more important


Bone & Joint Research
Vol. 8, Issue 6 | Pages 224 - 225
1 Jun 2019
Wilkinson JM


Bone & Joint 360
Vol. 6, Issue 4 | Pages 41 - 43
1 Aug 2017
de Bono J


Bone & Joint 360
Vol. 6, Issue 2 | Pages 37 - 39
1 Apr 2017
Khan T


Bone & Joint 360
Vol. 4, Issue 6 | Pages 1 - 1
1 Dec 2015
Ollivere B


Bone & Joint 360
Vol. 5, Issue 1 | Pages 1 - 1
1 Feb 2016
Ollivere B