Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 45 - 45
17 Nov 2023
Rix L Tushingham S Wright K Snow M
Full Access

Abstract. Objective. A common orthopaedic pain found in a wide spectrum of individuals, from young and active to the elderly is anterior knee pain (AKP). It is a multifactorial disorder which is thought to occur through muscular imbalance, overuse, trauma, and structural malalignment. Over time, this can result in cartilage damage and subsequent chondral lesions. Whilst the current gold standard for chondral lesion detection is MRI, it is not a highly sensitive tool, with around 20% of lesions thought to be mis-diagnosed by MRI. Single-photon emission computerised tomography with conventional computer tomography (SPECT/CT) is an emerging technology, which may hold clinical value for the detection of chondral lesions. SPECT/CT may provide valuable diagnostic information for AKP patients who demonstrate absence of structural change on other imaging modalities. This review systematically assessed the value of SPECT/CT as an imaging modality for knee pain, and its ability to diagnose chondral lesions for patients who present with knee pain. Methods. Using PRISMA guidelines, a systematic search was carried out in PubMed, Science Direct, and Web of Knowledge, CINAHL, AMED, Ovid Emcare and Embase. Inclusion criteria consisted of any English language article focusing on the diagnostic value of SPECT/CT for knee chondral lesions and knee pain. Furthermore, animal or cadaver studies, comparator technique other than SPECT/CT or patients with a pathology other than knee chondral lesions were excluded from the study. Relevant articles underwent QUADAS-2 bias assessment. Results. 11,982 manuscripts were identified, and the titles were screened for relevance. Seven studies were selected as being appropriate and were subjected to QUADAS-2 assessment. All 7 articles scored low for bias. Two papers deemed that the ICRS score of chondral lesions at intraoperative assessment correlated with SPECT/CT tracer uptake. Two studies concluded that MRI significantly correlated with SPECT/CT tracer uptake, with some instances whereby SPECT/CT identified more chondral lesions than MRI. Two papers compared bone scintigraphy (BS) to SPECT/CT and concluded that SPECT/CT was not only able to identify more chondral lesions than BS, but also localise and characterise the lesions. Conclusion. Evidence implies that SPECT/CT may be a useful imaging modality for the detection and localisation of cartilage lesions, particularly in discrepant cases whereby there is an absence of lesions on other imaging modalities, or a lack of correspondence with patients’ symptoms. More studies would be of value to confirm the conclusions of this review. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 13 - 13
1 Sep 2021
Patankar A Fragkakis EM Papadakos N Fenner C Ajayi B Beharry N Lupu C Bernard J Bishop T Lui DF
Full Access

Introduction. Degenerative spondylosis (DS) represents a challenging condition to diagnose and treat. There are multiple modalities to investigate DS including X-ray, MRI and CT, but symptoms may not be equivocal to DS to support the clinical findings. The investigation of metastases commonly utilises SPECT/CT for identification of areas of increased osteoblastic activity to denote disease. The aim of the study was to analyse the prevalence of asymptomatic DS in a consecutive hospital cohort of oncology patients who had SPECT/CT for investigation of metastases. Methods. Oncology patients who underwent SPECT/CT at St. George's Hospital were analysed between 2015–2019. Exclusion criteria: back pain, inflammatory disorders, metastases, trauma, infection. Radiology reports were examined for DS and anatomical distribution of tracer uptake. Results. A total of 1182 patients had a Whole-Body SPECT CT used for the spinal analysis. After exclusions (age >80 [n=260], non-cancer [n=318], back pain [n=72]), 522 reports with cancer were utilised. Mean age was 65 (4–80). Age and distribution of DS are given in the table. Conclusion. The prevalence of radiological asymptomatic DS is prevalent in large proportions of patients without back pain, and its incidence increases with age. Approximately 60% of 60 year old and 70% of 70 years old patients have asymptomatic DS in the lumbosarcal region. We conclude that SPECT/CT will detect radiographic degenerative spondylosis in an asymptomatic hospital cohort and this prevalence increase with age. Therefore, this modality of imaging must be utilised with caution when investigating potential pain generators. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 516 - 516
1 Sep 2012
Kang S Han H Lee D
Full Access

The purpose of this study was to validate the usefulness of SPECT/CT as an evaluation method for determining treatment and prognosis for patellofemoral cartilage lesions, based on MRI and arthroscopic findings. From August 2009 to February 2010, SPECT/CT was performed on 80 patients (24 male and 56 female, average 53.3 years old) with chronic anterior knee pain who had no degenerative changes or patellar malalignment on plain radiographs. Radioisotope uptake findings on patellofemoral joint from SPECT/CT were classified into three grades by one nuclear medicine specialist. In the patients who demonstrated poor improvements after conservative treatments, MRI and arthroscopy were performed. Patellofemoral cartilage conditions under arthroscopic finding (ICRS grades) were compared with SPECT/CT grading. In all cases, there were increased uptakes on patellofemoral joints. Eighteen cases showed low uptake (Group 1), 22 cases showed medium uptake (Group 2) and 40 cases high uptake (Group 3). At the follow-up examination after mean 1.7 months, 16 cases of Group 1 (89%), 14 cases of Group 2 (64%) and 28 cases of Groups3 (70%) responded positively to the conservative treatments. For those 22 cases showing poor improvement, MRI and arthroscopy were done. Damage or thinning of patellofemoral cartilage, subchondral cyst, edema and fissuring were observed in every case that underwent MRI. Every arthroscopic case was found that there was patellofemoral cartilage damage. Each of ICRS grade I and grade II was found in 2 cases from Group 1. Two cases of grade II, 4 cases of grade III, and 2 cases of grade IV were found in Group 2. Two cases of grade II, 4 cases of grade III, and 6 cases of grade IV were found in Group 3. There was significant difference in the success rate of conservative treatment between SPECT/CT grade 1 and 2 or 3. And there was significant association between SPECT/CT grade and ICRS grade (P=0.034). SPECT/CT could be a useful modality in determining the treatment and prognosis for patellofemoral cartilage lesions compared with MRI and arthroscopic findings


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 27 - 27
1 Nov 2014
Bilal A Boddu K Hussain S Mulholland N Vivian G Edmonds M Kavarthapu V
Full Access

Introduction:. Charcot arthropathy is a complex condition affecting diabetic patients with neuropathy. Diagnosis of acute Charcot arthropathy particularly in absence of any perceptible trauma is very challenging as clinically it can mimic osteomyelitis and cellulitis. Delay in recognition of Charcot arthropathy can result in gross instability of foot and ankle. Early diagnosis can provide an opportunity to halt the progression of disease. We report the role of SPECT /CT in the early diagnosis and elucidation of the natural progression of the disease. Methods:. Our multidisciplinary team analysed the scans of neuropathic patients presented with acute red, hot, swollen foot with normal radiological findings (Eichenholtz stage 0), attending the diabetic foot clinic from 2009–2013. The patients were selected from our database, clinic and nuclear medicine records. Initial workup included the assessment of peripheral neuropathy, temperature difference, between the feet, serum inflammatory markers and weight bearing dorsoplantar, lateral and oblique x-rays. All patients had three dimensional triple Phase Bone Scan using 800Mbq . 99m. Tc HDP followed by CT scan. Those patients with obvious radiological findings and signs of infection were excluded. Results:. We evaluated 193 scans in 189 patients. One hundred and forty nine patients showed increase in focal radionuclide uptake at ligament insertion or subchondral bone with a positive predictive value of 77 percent. Forty four out of 193 were negative for Charcot changes and they were not treated as Charcot. These patients did not develop any Charcot changes in the mean follow up of 8 months, indicating a clinically false positive rate of 23%. Conclusion:. SPECT/CT scan is a highly sensitive and specific tool for early diagnosis and accurate localisation of Charcot neuroarthropathy as clinical examination results in high false positive rate. SPECT/CT also helps to understand the natural progression of this disease


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 95 - 95
1 Dec 2017
Falstie-Jensen T Daugaard H Lange J Ovesen J Søballe K
Full Access

Background. Periprostetic joint infections (PJI) are often difficult to diagnose, to treat and often leave the patient with severe impaired function. The presence of low virulent bacteria is frequently discovered in apparent aseptic revisions of shoulder arthroplasties and pose a challenge to diagnose preoperatively. Dual Isotope In111 Leucocyte/ Tc99 Bone Marrow SPECT CT scan (L/BMS) is considered the radionuclide gold standard in preoperative diagnosing PJI with reported high specificity and sensitivity in hip and knee arthroplasties. Unfortunately, it is labour-intensive and expensive to perform and documentation using L/BMS on shoulder arthroplasties lack. Aim. To investigate if L/BMS succeeds in detecting shoulder PJI compared to tissue cultures obtained perioperatively. Method. All patients referred to a highly-specialised shoulder department with a painful or stiff shoulder-arthroplasty were included in the cohort. To diagnose infection as a possible cause of arthroplasty failure a L/BMS was planned for all patients. If the arthroplasty was revised, 5 tissue biopsies were obtained from the most infection-suspicious site during revision. Biopsies were cultured in broth and on plates for 14 days due to the high frequency of low virulent infection in shoulder revisions. Infection was defined as growth of the same bacteria in 3 or more of 5 the biopsies. Results. During the observation period 71 patients were referred. Revision surgery was performed in 62% of the patients (44/71) of which 29 also had been examined by L/BMS. A microbiological diagnose was available for all. The most predominant organism isolated was P. Acnes. Two patients both had a positive L/BMS and positive cultures. Negative L/BMS and negative cultures were found in 20 patients. The remaining 7 patients had negative L/BMS, but positive cultures. The two patients with a positive L/BMS both showed overt clinical signs of infection. L/BMS show a sensitivity 0.22 95%CI(0–0.49) and specificity 1.00 95%CI(1.00–1.00) in detecting shoulder PJI. The Positive Predictive Value is 1.00 95%CI(1.00–1.00) and Negative Predictive Value 0.74 95%CI(0.57–0.90). No patients infected with P. Acnes resulted in a positive scintigraphy nor had they preoperative or perioperative signs of infection. Conclusion. Only patients with severe infectious symptoms of shoulder PJI resulted in positive L/BMS. Hence, the scan added nothing to the preoperative clinical diagnose. In111 Leucocyte/ Tc99 Bone Marrow SPECT CT scan cannot be recommended as a standard screening procedure when evaluating failed shoulder arthroplasties for possible infection


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 71 - 71
1 Dec 2016
Lopez D Moore E Nickerson E Norrish A
Full Access

Aim. To demonstrate the use of indium-111 white-cell labelled SPECT CT (In111-WC-SPECT-CT) in bone infection. Method. This novel imaging modality is useful in bone infection. We present three cases of complex osteomyelitis to illustrate this. All were imaged with conventional modalities, but conclusive diagnosis could not be achieved. In111-WC-SPECT-CT was used to provide the definitive imaging that allowed successful treatment. Results. Case 1- A 29 y/o Male with spina bifida presented with chronic calcaneal osteomyelitis. Previous treatment included debridement, but recurrent infection ensued. MRI showed widespread changes consistent with infection throughout the calcaneus and a below knee amputation was planned. In111-WC-SPECT-CT (Figure 1) showed a distinct localised nidus of infection. A targeted sequestrectomy was performed and the patient has been infection free for four years. He was spared the amputation. Case-2- A 73 y/o male presented with a radiation induced colo-cutaneous fistula and pelvic chronic osteomyelitis. Surgical treatment included multiple debridements and sequestrectomy. He re-presented pain with pain in his pelvis six months later. MRI was performed and oedema seen in the bone. This was presumed to be infection and further surgery was planned. An In111-WC-SPECT-CT was then performed and confirmed no residual bone infection. The patient was spared surgery. Case-3- A 38 y/o female was involved in an RTA 6 months prior to presentation. She underwent fixation of her tibia with skin grafting for an open fracture. There was clinical suspicion of deep infection. The metalwork made MRI difficult to interpret. An In111-WCC-SPECT-CT confirmed infection around the metal screw and this evidence instigated a prolonged course of antibiotics to suppress the infection. The screw will be removed after the fracture heals. Conclusions. In-111-WC-SPECT-CT is an emerging imaging modality. We present three cases of complex bone and joint infection; where this imaging has altered the course of treatment


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 65 - 65
1 Sep 2012
Singh V Parthipun A Sott A
Full Access

Aim

Single-photon emission computed tomography is a new imaging modality combining high detail CT with highly sensitive triple phase nuclear bone scanning to help clinicians in diagnosis and management of various conditions. Little has been published about its particular usefulness in foot and ankle pathology. We conducted a prospective study to evaluate the role of SPECT for the same.

Material and Methods

Fifty patients were seen in a tertiary referral foot and ankle clinic presenting with a variety of foot and ankle conditions. SPECT-CT was requested when a definitive clinical diagnosis could not be reached after thorough clinical examination and plain radiography. Pathology shown by SPECT-CT was taken as the final diagnosis and interventional surgical management carried out accordingly. Patients were subsequently seen in the follow up clinic to evaluate the outcome of their treatment.


Bone & Joint Research
Vol. 11, Issue 6 | Pages 398 - 408
22 Jun 2022
Xu T Zeng Y Yang X Liu G Lv T Yang H Jiang F Chen Y

Aims. We aimed to evaluate the utility of . 68. Ga-citrate positron emission tomography (PET)/CT in the differentiation of periprosthetic joint infection (PJI) and aseptic loosening (AL), and compare it with . 99m. Tc-methylene bisphosphonates (. 99m. Tc-MDP) bone scan. Methods. We studied 39 patients with suspected PJI or AL. These patients underwent . 68. Ga-citrate PET/CT, . 99m. Tc-MDP three-phase bone scan and single-photon emission CT (SPECT)/CT. PET/CT was performed at ten minutes and 60 minutes after injection, respectively. Images were evaluated by three nuclear medicine doctors based on: 1) visual analysis of the three methods based on tracer uptake model, and PET images attenuation-corrected with CT and those not attenuation-corrected with CT were analyzed, respectively; and 2) semi-quantitative analysis of PET/CT: maximum standardized uptake value (SUVmax) of lesions, SUVmax of the lesion/SUVmean of the normal bone, and SUVmax of the lesion/SUVmean of the normal muscle. The final diagnosis was based on the clinical and intraoperative findings, and histopathological and microbiological examinations. Results. Overall, 23 and 16 patients were diagnosed with PJI and AL, respectively. The sensitivity and specificity of three-phase bone scan and SPECT/CT were 100% and 62.5%, 82.6%, and 100%, respectively. Attenuation correction (AC) at 60 minutes and non-AC at 60 minutes of PET/CT had the same highest sensitivity and specificity (91.3% and 100%), and AC at 60 minutes combined with SPECT/CT could improve the diagnostic efficiency (sensitivity = 95.7%). Diagnostic efficacy of the SUVmax was low (area under the curve (AUC) of ten minutes and 60 minutes was 0.814 and 0.806, respectively), and SUVmax of the lesion/SUVmean of the normal bone at 60 minutes was the best semi-quantitative parameter (AUC = 0.969). Conclusion. 68. Ga-citrate showed the potential to differentiate PJI from AL, and visual analysis based on uptake pattern of tracer was reliable. The visual analysis method of AC at 60 minutes, combined with . 99m. Tc-MDP SPECT/CT, could improve the sensitivity from 91.3% to 95.7%. In addition, a major limitation of our study was that it had a limited sample size, and more detailed studies with a larger sample size are warranted. Cite this article: Bone Joint Res 2022;11(6):398–408


Introduction. The degree of cartilage degeneration assessed intraoperatively may not be sufficient as a criterion for patellar resurfacing in total knee arthroplasty (TKA). However, single-photon emission tomography/computed tomography (SPECT/CT) is useful for detecting osteoarthritic involvement deeper in the subchondral bone. The purpose of the study was to determine whether SPECT/CT reflected the cartilage lesion underneath the patella in patients with end-stage osteoarthritis (OA) and whether clinical outcomes after TKA without patellar resurfacing differed according to the severity of patellofemoral (PF) OA determined by visual assessment and SPECT/CT findings. Methods. This study included 206 knees which underwent TKA. The degree of cartilage degeneration was graded intraoperatively according to the International Cartilage Repair Society grading system. Subjects were classified into four groups according to the degree of bone tracer uptake (BTU) on SPECT/CT in the PF joint. The Feller's patella score and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were assessed preoperatively and postoperative 1 and 2 years. Results. The increased BTU in the PF joint was associated with more severe degenerative cartilage changes underneath the patella (P < 0.001). The risk for the presence of denudated cartilage was greater in the high uptake group (odds ratio = 5.89). There was no association between clinical outcomes and visual grading of patellar cartilage degeneration or the degree of BTU on SPECT/CT. Discussion and Conclusions. The visual assessment of the degree of cartilage degeneration underneath the patella and preoperative SPECT/CT evaluation of the PF joint were not predictive of clinical outcome after TKA with unresurfaced patella


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 76 - 76
1 Mar 2012
Iranpour F Konala P Cobb JP Friederich N Hirschmann MT
Full Access

Introduction. SPECT/CT might be a promising diagnostic modality in patients with painful total knee arthroplasty. It was the purpose of our study to introduce a novel standardised SPECT/CT algorithm for assessing patients with painful primary total knee arthroplasty and to evaluate its clinical applicability and inter- and intra-observer variation and reliability. Methods. A novel SPECT/CT localisation scheme, which consists of 9 tibial, 9 femoral and 4 patellar regions on standardised transverse, coronal, and sagittal slices was introduced. It was assessed in 18 consecutive patients with painful knees after total knee arthroplasty. The localisation and level of the tracer uptake on SPECT/CT were noted using a color coded 10 steps graded scale (0-100). The inter and intra-observer reliability were assessed. The femoral and tibial prosthetic component position was assessed in the CT images after 3D reconstruction and aligning them to standardised frames of reference. The average root mean square difference±standard deviations and ranges of these measured angles are presented along with the intraclass correlation coefficients for inter- and intraobserver reliability. Results. The localisation scheme was useful and easily applicable in all 18 cases. The novel classification using the SPECT/CT for the femoral, the tibial and patellar region was reliable. The measurements of component position in SPECT/CT images were highly reliable and feasible in all cases with sufficient visibility of the landmarks. The mean intra-observer difference between the rotational alignment measurements of tibial and femoral components was less than 2° (2SD 1°). The intra-observer variability for these measurements was less than 1 degree (2SD 1°). Conclusions. The introduced algorithm using SPECT/CT in patients after total knee arthroplasty, which combines mechanical (assessment of 3D rotational alignment of the prosthesis in the inherent CT data) and metabolic data (SPECT/CT localisation scheme), was highly reliable and useful. We propose its use in larger scaled clinical studies to investigate its clinical value


Bone & Joint 360
Vol. 2, Issue 4 | Pages 19 - 21
1 Aug 2013

The August 2013 Spine Roundup. 360 . looks at: SPECT CT and facet joints; a difficult conversation: scoliosis and complications; time for a paradigm shift? complications under the microscope; minor trauma and cervical injury: a predictable phenomenon?; more costly all round: incentivising more complex operations?; minimally invasive surgery = minimal scarring; and symptomatic lumbar spine stenosis


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_10 | Pages 40 - 40
1 Oct 2019
Suresh S Shafafy R Fakouri B Isaac A Panchmatia J
Full Access

Background Context. SPECT-CT is a hybrid imaging modality, which has become very well established in the diagnosis of inflammatory, vascular and malignant processes affecting the spine. However, little evidence exists on its application with degenerative pathologies. Purpose & Study Design. Systematic review on the use of SPECT-CT in the diagnosis of degenerative facet joint arthropathy. Patient Sample. 824 patients across 10 studies conducted over the last 6 years (2012 – 2018), with a mean age of 51.8 years old. All studies excluded patients with malignancy, infection or inflammatory aetiologies or those related to acute trauma. Only degenerative pathologies of the lumbar spine in an adult population were included. Methods. A systematic review of the literature available on the topic was conducted using the PubMed, Cochrane, Medline and Embase online databases of journal articles. Results. Five studies focused on SPECT-CT alone / versus CT. Two focused on SPECT-CT vs MRI, and three focussed on SPECT-CT guided facet joint injections. Of these 10 studies, seven concluded with results supporting SPECT CT's use, two reported discordance between SPECT-CT findings with those diagnosed from clinical examination / MRI scans, and one study's conclusions were equivocal. Conclusion. SPECT-CT shows promise as an imaging adjunct in assisting with the diagnosis and subsequent treatment of degenerative facet joint arthropathies. In patients whose MRI scans reveal multiple potential pain generators, SPECT-CT could help differentiate between clinically significant sources of pain and may even serve a purpose in guiding facet joint injections in patients with inconclusive MRI / CT scans. No conflicts of interest. No funding obtained


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 100 - 100
1 Nov 2018
McAuley N McQuail P Nolan K Gibson D McKenna J
Full Access

Osteonecrosis is a potentially devastating condition with poorly defined pathogenesis that can affect several anatomical areas with or without a previous traumatic insult. Post traumatic osteonecrosis (PON) in the foot and ankle has been commonly described in the talus and navicular but rarely in the distal tibia. PON of the distal tibia is a rarely reported and infrequent complication of fracture dislocations of the ankle. Its scarcity can lead to misdiagnosis and inappropriate management due to a lack of clinical knowledge or suspicion with resultant severe functional compromise. We aim to highlight the clinical and radiological features of PON of the distal tibia and report the findings in a series of four patients following a fracture dislocation of the ankle. Three patients sustained a SER4 fracture dislocation and one patient sustained a PER4 fracture dislocation in keeping with standard patterns of injury seen in most trauma units. In each case, PON of the distal tibia presented with progressive anterolateral tibial plafond collapse and valgus deformity of the ankle. The radiological features previously reported in the literature are based on plain film x-ray, CT and MRI but no description of SPECT-CT findings. One of the patients in the series underwent SPECT-CT following clinical suspicion of PON and thus we describe the findings not previously reported. Our objective is to highlight this rare condition as a potential cause for ongoing pain following fracture dislocation of the ankle as well as advocating the use of SPECT/CT as a useful imaging modality to aid in the diagnosis


Bone & Joint Open
Vol. 5, Issue 4 | Pages 367 - 373
26 Apr 2024
Reinhard J Lang S Walter N Schindler M Bärtl S Szymski D Alt V Rupp M

Aims

Periprosthetic joint infection (PJI) demonstrates the most feared complication after total joint replacement (TJR). The current work analyzes the demographic, comorbidity, and complication profiles of all patients who had in-hospital treatment due to PJI. Furthermore, it aims to evaluate the in-hospital mortality of patients with PJI and analyze possible risk factors in terms of secondary diagnosis, diagnostic procedures, and complications.

Methods

In a retrospective, cross-sectional study design, we gathered all patients with PJI (International Classification of Diseases (ICD)-10 code: T84.5) and resulting in-hospital treatment in Germany between 1 January 2019 and 31 December 2022. Data were provided by the Institute for the Hospital Remuneration System in Germany. Demographic data, in-hospital deaths, need for intensive care therapy, secondary diagnosis, complications, and use of diagnostic instruments were assessed. Odds ratios (ORs) with 95% confidence intervals (CIs) for in-hospital mortality were calculated.


Bone & Joint Research
Vol. 1, Issue 5 | Pages 86 - 92
1 May 2012
Amarasekera HW Roberts P Costa ML Parsons N Achten J Griffin DR Williams NR

Objectives

To study the vascularity and bone metabolism of the femoral head/neck following hip resurfacing arthroplasty, and to use these results to compare the posterior and the trochanteric-flip approaches.

Methods

In our previous work, we reported changes to intra-operative blood flow during hip resurfacing arthroplasty comparing two surgical approaches. In this study, we report the vascularity and the metabolic bone function in the proximal femur in these same patients at one year after the surgery. Vascularity and bone function was assessed using scintigraphic techniques. Of the 13 patients who agreed to take part, eight had their arthroplasty through a posterior approach and five through a trochanteric-flip approach.