Advertisement for orthosearch.org.uk
Results 1 - 20 of 139
Results per page:
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 24 - 24
1 Mar 2010
Bourne RB Chesworth BM Davis AM Charron KDJ
Full Access

Purpose: The purpose of this study was to determine the reasons for patient dissatisfaction after primary TKA.

Method: Primary TKA patients (n=2513) entered into the Ontario Joint Replacement Registry (OJRR) with decision date and one year follow-up data (WOMAC, expectations, satisfaction and willingness to undergo surgery) were analyzed to determine the factors that might be associated with patients who were not satisfied with their total knee replacement.

Results: The majority of patients were satisfied with their TKA (n=1939, 81%), but 169 (7%) were uncertain and 281 (12%) were not satisfied. Pre-operative expectations were important as 89% of patients who did not have their expectations met and 40% who had no expectations were dissatisfied with their TKA. Factors that affected patient satisfaction for their TKA, controlling for age, comorbidity and post-operative complications were better pre-operative WOMAC function scores (p25 point improvement).

Conclusion: In this province-wide study, one in five TKA patients were not satisfied with their surgery at one-year follow-up. It is important that patients, surgeons and healthcare payers recognize significant factors that can lead to patient dissatisfaction and help patients establish realistic expectations prior to undergoing TKA surgery.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 921 - 925
9 Nov 2021
Limberg AK Wyles CC Taunton MJ Hanssen AD Pagnano MW Abdel MP

Aims

Varus-valgus constrained (VVC) devices are typically used in revision settings, often with stems to mitigate the risk of aseptic loosening. However, in at least one system, the VVC insert is compatible with the primary posterior-stabilized (PS) femoral component, which may be an option in complex primary situations. We sought to determine the implant survivorship, radiological and clinical outcomes, and complications when this VVC insert was coupled with a PS femur without stems in complex primary total knee arthroplasties (TKAs).

Methods

Through our institution’s total joint registry, we identified 113 primary TKAs (103 patients) performed between 2007 and 2017 in which a VVC insert was coupled with a standard cemented PS femur without stems. Mean age was 68 years (SD 10), mean BMI was 32 kg/m2 (SD 7), and 59 patients (50%) were male. Mean follow-up was four years (2 to 10).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 14 - 14
10 Feb 2023
Vertesich K Staats K Böhler C Koza R Lass R Giurea A
Full Access

The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Aim of this study was to investigate long term results of a new RH prosthesis (EnduRo®, B Braun, Germany), which uses carbon-fiber reinforced poly-ether-ether-ketone (CFR PEEK) as a new bearing material, first time used in knee arthroplasty. Fifty-six consecutive patients, who received the EnduRo® RH prosthesis were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. Min. Follow up was 7 and mean follow up 9,3 years. Clinical examination included Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and range of motion (ROM). Competing risk analysis was assessed for survival with respect to indication and failure mode. KSS, WOMAC, OKS, and ROM significantly improved from the preoperative to the follow up investigations (p < 0.0001). There was no difference in clinical outcome between the primary and the revision group. The overall cumulative incidence for revision for any reason was 23.6% and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). The evaluated RH prosthesis provided reliable and durable results with a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of cases. The use of this RH system in primary patients showed high survival rates. Long-term functional and clinical results proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 118 - 118
23 Feb 2023
Zhou Y Dowsey M Spelman T Choong P Schilling C
Full Access

Approximately 20% of patients feel unsatisfied 12 months after primary total knee arthroplasty (TKA). Current predictive tools for TKA focus on the clinician as the intended user rather than the patient. The aim of this study is to develop a tool that can be used by patients without clinician assistance, to predict health-related quality of life (HRQoL) outcomes 12 months after total knee arthroplasty (TKA). All patients with primary TKAs for osteoarthritis between 2012 and 2019 at a tertiary institutional registry were analysed. The predictive outcome was improvement in Veterans-RAND 12 utility score at 12 months after surgery. Potential predictors included patient demographics, co-morbidities, and patient reported outcome scores at baseline. Logistic regression and three machine learning algorithms were used. Models were evaluated using both discrimination and calibration metrics. Predictive outcomes were categorised into deciles from 1 being the least likely to improve to 10 being the most likely to improve. 3703 eligible patients were included in the analysis. The logistic regression model performed the best in out-of-sample evaluation for both discrimination (AUC = 0.712) and calibration (gradient = 1.176, intercept = -0.116, Brier score = 0.201) metrics. Machine learning algorithms were not superior to logistic regression in any performance metric. Patients in the lowest decile (1) had a 29% probability for improvement and patients in the highest decile (10) had an 86% probability for improvement. Logistic regression outperformed machine learning algorithms in this study. The final model performed well enough with calibration metrics to accurately predict improvement after TKA using deciles. An ongoing randomised controlled trial (ACTRN12622000072718) is evaluating the effect of this tool on patient willingness for surgery. Full results of this trial are expected to be available by April 2023. A free-to-use online version of the tool is available at . smartchoice.org.au.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 45 - 45
1 Oct 2022
Fes AF Pol AP Pérez-Prieto D Gomez PH Alier A Verdié LP Garcia JCM
Full Access

Aim. One of the most severe complications of primary total knee arthroplasty (TKA) is periprosthetic joint infection (PJI). Nowadays, the use of antibiotic-loaded cement for prevention of infection is still controversial. The aim of the present study is to evaluate the use of an antibiotic-loaded cement to reduce the infection rate in primary total knee arthroplasty. Method. Prospective randomized study, with 2893 cemented total knee arthroplasties performed between 2005 and 2010 in our institution. Two different groups were formed depending on which bone cement was used, without antibiotic (the control group) or loaded with erythromycin and colistin (the study group). All patients received the same systemic prophylactic antibiotics. The patients were followed for a minimum of twelve months. The rate of infection was analyzed according to the criteria of the Centers for Disease Control and Prevention (CDC). Results. In 1452 patients the prosthetic components were fixed using bone cement without antibiotic and in 1441 patients bone cement loaded with erythromycin and colistin was used. There were no differences between both groups in terms of demographic data (age, sex and BMI), either in operating time (p>0,05). The rate of infection was similar in both groups, being 2,0% (n=29) in the control group and 1,7% in the study group (p=0,58) at 8,7 years (SD 5,1) of follow up. In terms of prosthetic revision due to any cause (infected or aseptic), there wasn't differences between groups, performing a total of 61 revision arthroplasties in control group and 68 in study group (p>0,05). Moreover, we analyzed the erythromycin resistance rate, being no differences between both groups (p=0.6). Conclusions. The use of erythromycin and colistin-loaded bone cement in total knee arthroplasty did not lead to a decrease in the rate of infection when systemic prophylactic antibiotics were used, a finding that suggests that its use would not be indicated in the general population


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 62 - 62
1 Dec 2022
Bansal R Bourget-Murray J Brunet L Railton P Sharma R Soroceanu A Piroozfar S Smith C Powell J
Full Access

The aim of this study was to determine the incidence, annual trend, perioperative outcomes, and identify risk factors of early-onset (≤ 90 days) deep surgical site infection (SSI) following primary total knee arthroplasty (TKA) for osteoarthritis. Risk factors for early-onset deep SSI were assessed. We performed a retrospective population-based cohort study using prospectively collected patient-level data from several provincial administrative data repositories between January 2013, and March 2020. The diagnosis of early-onset deep SSI was based on published Centre for Disease Control/National Healthcare Safety Network (CDC/NHSN) definitions. The Mann-Kendall Trend Test was used to detect monotonic trends in early-onset deep SSI rates over time. The effects of various patient and surgical risk factors for early-onset deep SSI were analyzed using multiple logistic regression. Secondary outcomes were 90-day mortality and 90-day readmission. A total of 20,580 patients underwent primary TKA for osteoarthritis. Forty patients had a confirmed deep SSI within 90-days of surgery representing a cumulative incidence of 0.19%. The annual infection rate did not change over the 7-year study period (p = 0.879). Risk factors associated with early-onset deep SSI included blood transfusions (OR, 3.93 [95% CI 1.34-9.20]; p=0.004), drug or alcohol abuse (OR, 4.91 [95% CI 1.85-10.93]; p<0.001), and surgeon volume less than 30 TKA per year (OR, 4.45 [1.07-12.43]; p=0.013). Early-onset deep SSI was not associated with 90-days mortality (OR, 11.68 [0.09-90-58]; p=0.217), but was associated with an increased chance of 90-day readmission (OR, 50.78 [26.47-102.02]; p<0.001). This study establishes a reliable baseline infection rate for early-onset deep SSI after TKA for osteoarthritis through the use of a robust methodological process. Several risk factors for early-onset deep SSI are potentially modifiable or can be optimized prior to surgery and be effective in reducing the incidence of early-onset SSI. This could guide the formulation of provincial screening programs and identify patients at high risk for SSI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 5 - 5
7 Jun 2023
Prakash R Abid H Wasim A Sharma A Agrawal Y
Full Access

The National Health Service produces over 500,000 tonnes of waste and 25 mega tonnes of CO2 annually. Operating room waste is segregated into different streams which are recycled, disposed of in landfill sites, or undergo costly and energy-intensive incineration processes. By assessing the quantity and recyclability of waste from primary hip and knee arthroplasty cases, we aim to identify strategies to reduce the carbon footprint of arthroplasty surgery. Data was collected prospectively at a tertiary orthopaedic hospital, in the theatres of six arthroplasty surgeons between April – July 2022. Fifteen primary total hip arthroplasty (THA) and 16 primary total knee arthroplasty (TKA) cases were included; revision and complex primary cases were excluded. Waste was categorised into non-hazardous waste, hazardous waste, recycling, sharps, and linens. Each waste category was weighed. Items disposed as non-hazardous waste were catalogued for a sample of 10 TKA and 10 THA cases. Recyclability of items was determined from packaging. Average total waste generated for THA and TKA were 14.46kg and 17.16kg respectively, with TKA generating significantly greater waste (p < 0.05). On average only 5.4% of waste was recycled in TKA and just 2.9% in THA cases. The mean recycled waste was significantly greater in TKA cases compared to THA, 0.93kg and 0.42kg respectively (p < 0.05). Hazardous waste represented the largest proportion of the waste streams for both TKA (69.2%) and THA (73.4%). On average TKA generated a significantly greater amount (11.87kg) compared to THA (10.61kg), p < 0.05. Non-hazardous waste made up 15.1% and 11.3% of total waste for TKA and THA respectively. In the non-hazardous waste, only two items (scrub brush packaging and sterile towel packaging) were identified as recyclable based on packaging. We estimate that annually total hip and knee arthroplasty generates over 2.7 million kg of waste in the UK. Through increased use of recyclable plastics for packaging, combined with clear labelling of items as recyclable, medical suppliers can significantly reduce the carbon footprint of arthroplasty. Our data highlight only a very small percentage of waste is recycled in total hip and knee arthroplasty cases


Bone & Joint Open
Vol. 5, Issue 9 | Pages 758 - 765
12 Sep 2024
Gardner J Roman ER Bhimani R Mashni SJ Whitaker JE Smith LS Swiergosz A Malkani AL

Aims. Patient dissatisfaction following primary total knee arthroplasty (TKA) with manual jig-based instruments has been reported to be as high as 30%. Robotic-assisted total knee arthroplasty (RA-TKA) has been increasingly used in an effort to improve patient outcomes, however there is a paucity of literature examining patient satisfaction after RA-TKA. This study aims to identify the incidence of patients who were not satisfied following RA-TKA and to determine factors associated with higher levels of dissatisfaction. Methods. This was a retrospective review of 674 patients who underwent primary TKA between October 2016 and September 2020 with a minimum two-year follow-up. A five-point Likert satisfaction score was used to place patients into two groups: Group A were those who were very dissatisfied, dissatisfied, or neutral (Likert score 1 to 3) and Group B were those who were satisfied or very satisfied (Likert score 4 to 5). Patient demographic data, as well as preoperative and postoperative patient-reported outcome measures, were compared between groups. Results. Overall, 45 patients (6.7%) were in Group A and 629 (93.3%) were in Group B. Group A (vs Group B) had a higher proportion of male sex (p = 0.008), preoperative chronic opioid use (p < 0.001), preoperative psychotropic medication use (p = 0.01), prior anterior cruciate ligament (ACL) reconstruction (p < 0.001), and preoperative symptomatic lumbar spine disease (p = 0.004). Group A was also younger (p = 0.023). Multivariate analysis revealed preoperative opioid use (p = 0.012), prior ACL reconstruction (p = 0.038), male sex (p = 0.006), and preoperative psychotropic medication use (p = 0.001) as independent predictive factors of patient dissatisfaction. Conclusion. The use of RA-TKA demonstrated a high rate of patient satisfaction (629 of 674, 93.3%). Demographics for patients not satisfied following RA-TKA included: male sex, chronic opioid use, chronic psychotropic medication use, and prior ACL reconstruction. Patients in these groups should be identified preoperatively and educated on realistic expectations given their comorbid conditions. Cite this article: Bone Jt Open 2024;5(9):758–765


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 573 - 581
1 Jun 2024
van Houtert WFC Strijbos DO Bimmel R Krijnen WP Jager J van Meeteren NLU van der Sluis G

Aims. To investigate the impact of consecutive perioperative care transitions on in-hospital recovery of patients who had primary total knee arthroplasty (TKA) over an 11-year period. Methods. This observational cohort study used electronic health record data from all patients undergoing preoperative screening for primary TKA at a Northern Netherlands hospital between 2009 and 2020. In this timeframe, three perioperative care transitions were divided into four periods: Baseline care (Joint Care, n = 171; May 2009 to August 2010), Function-tailored (n = 404; September 2010 to October 2013), Fast-track (n = 721; November 2013 to May 2018), and Prehabilitation (n = 601; June 2018 to December 2020). In-hospital recovery was measured using inpatient recovery of activities (IROA), length of stay (LOS), and discharge to preoperative living situation (PLS). Multivariable regression models were used to analyze the impact of each perioperative care transition on in-hospital recovery. Results. The four periods analyzed involved 1,853 patients (65.9% female (1,221/1,853); mean age 70.1 years (SD 9.0)). IROA improved significantly with each transition: Function-tailored (0.9 days; p < 0.001 (95% confidence interval (CI) -0.32 to -0.15)), Fast-track (0.6 days; p < 0.001 (95% CI -0.25 to -0.16)), and Prehabilitation (0.4 days; p < 0.001 (95% CI -0.18 to -0.10)). LOS decreased significantly in Function-tailored (1.1 days; p = 0.001 (95% CI -0.30 to -0.06)), Fast-track (0.6 days; p < 0.001 (95% CI -0.21 to -0.05)), and Prehabilitation (0.6 days; p < 0.001 (95%CI -0.27 to -0.11)). Discharge to PLS increased in Function-tailored (77%), Fast-track (91.6%), and Prehabilitation (92.6%). Post-hoc analysis indicated a significant increase after the transition to the Fast-track period (p < 0.001 (95% CI 3.19 to 8.00)). Conclusion. This study highlights the positive impact of different perioperative care procedures on in-hospital recovery of patients undergoing primary TKA. Assessing functional recovery, LOS, and discharge towards PLS consistently, provides hospitals with valuable insights into postoperative recovery. This can potentially aid planning and identifying areas for targeted improvements to optimize patient outcomes. Cite this article: Bone Joint J 2024;106-B(6):573–581


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 49 - 49
1 Dec 2022
Khalik HA Wood T Tushinski D Gazendam A Petruccelli D Bali K
Full Access

Primary hip and knee joint replacements in Canada have been estimated to cost over $1.4 billion dollars annually, with revision surgery costing $177 million. The most common cause of revision arthroplasty surgery in Canada is infection. Periprosthetic joint infections (PJIs) are a devastating though preventable complication following arthroplasty. Though variably used, antibiotic laden bone cement (ALBC) has been demonstrated to decrease PJIs following primary total knee arthroplasty (TKA). Unfortunately, ALBC is costlier than regular bone cement (RBC). Therefore, the aim of this study was to determine if the routine use of ALBC in primary TKA surgery is a cost-effective practice from the perspective of the Canadian healthcare system. A decision tree was constructed using a decision analysis software (TreeAge Software, Williamstown, Massachusetts) to a two-year time horizon comparing primary TKA with either ALBC or RBC from the perspective of a single-payer healthcare system. All costs were in 2020 Canadian dollars. Health utilities were in the form of quality adjusted life years (QALYs). Model inputs for cost were derived from regional and national databases. Health utilities and probability parameters were derived from the latest literature. One-way deterministic sensitivity analysis was performed on all model parameters. The primary outcome of this analysis was an incremental cost-effectiveness ratio (ICER) with a willingness-to-pay (WTP) threshold of $50,000 per QALY. Primary TKA with ALBC (TKA-ALBC) was found to be more cost-effective compared to primary TKA with RBC (TKA-RBC). More specifically, TKA-ALBC dominated TKA-RBC as it was less costly on the long term ($11,160 vs. $11,118), while providing the same QALY (1.66). The ICER of this cost-utility analysis (CUA) was $-11,049.72 per QALY, much less than the WTP threshold of $50,000 per QALY. The model was sensitive to costs of ALBC-TKA as well as the probability of PJI following ALBC-TKA and RBC-TKA. ALBC ceased to be cost effective once the cost of ALBC was greater than $223.08 CAD per bag of cement. The routine use of ALBC in primary TKA is a cost-effective practice in the context of the Canadian healthcare system as long as the cost of ALBC is maintained at a reasonable price and the published studies to-date keep supporting the efficacy of ALBC in decreasing PJI following primary TKA. Further, this analysis is very conservative, and ALBC is likely much more cost-effective than presented. This is due to this model's revision surgery cost parameter being based on the average cost of all revision TKA surgery in Canada, regardless of etiology. Considering many PJIs require two-stage revisions, the cost parameter used in this analysis for revision surgery is an underestimate of true cost. Ultimately, this is the first cost-effectiveness study evaluating this topic from the perspective of the Canadian healthcare system and can inform future national guidelines on the subject matter


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 2 - 2
1 Dec 2021
Thompson O Stefánsdóttir A W-Dahl A Robertsson O Gordon M Lindgren V
Full Access

Aim. Strenuous efforts to minimize postoperative infection rates have been made, including the Swedish nation-wide initiative Prosthesis Related Infections Shall be Stopped (PRISS). The aim of this study was to calculate the incidence rate of periprosthetic joint infections (PJI) following primary total knee arthroplasty (TKA) before and after PRISS. Method. All 45,438 primary TKAs registered in the Swedish knee arthroplasty register (SKAR) during 2007–2008 and 2012–2013 were included. Matched data on antibiotic prescriptions were obtained from the Swedish Prescribed Drug Register (SPDR). All patients with ≥28 days of continuous antibiotic treatment within 2 years of primary surgery had their medical charts reviewed to identify cases of PJI. Results. 644 PJIs were identified, equaling a 2-year cumulative incidence rate of 1.42% (95% CI: 1.31–1.53). The incidence rate was 1.41% before PRISS and 1.43% after. Diagnosis was made within 30 days of primary TKA in 52%, and within 90 days in 73% of the cases. 603 cases were reoperated. Debridement with exchange of the insert was performed in 32.1% and 62.5% of cases before and after PRISS respectively. Conclusions. No reduction in cumulative PJI incidence was seen after the PRISS initiative


Bone & Joint Open
Vol. 3, Issue 1 | Pages 35 - 41
9 Jan 2022
Buchalter DB Nduaguba A Teo GM Kugelman D Aggarwal VK Long WJ

Aims. Despite recent literature questioning their use, vancomycin and clindamycin often substitute cefazolin as the preoperative antibiotic prophylaxis in primary total knee arthroplasty (TKA), especially in the setting of documented allergy to penicillin. Topical povidone-iodine lavage and vancomycin powder (VIP) are adjuncts that may further broaden antimicrobial coverage, and have shown some promise in recent investigations. The purpose of this study, therefore, is to compare the risk of acute periprosthetic joint infection (PJI) in primary TKA patients who received cefazolin and VIP to those who received a non-cephalosporin alternative and VIP. Methods. This was a retrospective cohort study of 11,550 primary TKAs performed at an orthopaedic hospital between 2013 and 2019. The primary outcome was PJI occurring within 90 days of surgery. Patients were stratified into two groups (cefazolin vs non-cephalosporin) based on their preoperative antibiotic. All patients also received the VIP protocol at wound closure. Bivariate and multiple logistic regression analyses were performed to control for potential confounders and identify the odds ratio of PJI. Results. In all, 10,484 knees (90.8%) received cefazolin, while 1,066 knees (9.2%) received a non-cephalosporin agent (either vancomycin or clindamycin) as preoperative prophylaxis. The rate of PJI in the cefazolin group (0.5%; 48/10,484) was significantly lower than the rate of PJI in the non-cephalosporin group (1.0%; 11/1,066) (p = 0.012). After controlling for confounding variables, the odds ratio (OR) of developing a PJI was increased in the non-cephalosporin cohort compared to the cefazolin cohort (OR 2.389; 1.2 to 4.6); p = 0.01). Conclusion. Despite the use of topical irrigant solutions and addition of local antimicrobial agents, the use of a non-cephalosporin perioperative antibiotic continues to be associated with a greater risk of TKA PJI compared to cefazolin. Strategies that increase the proportion of patients receiving cefazolin rather than non-cephalosporin alternatives must be emphasized. Cite this article: Bone Jt Open 2022;3(1):35–41


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 62 - 62
1 Dec 2021
Wang Q Goswami K Xu C Tan T Clarkson S Parvizi J
Full Access

Aim. Whether laminar airflow (LAF) in the operating room (OR) is effective for decreasing periprosthetic joint infection (PJI) following total joint arthroplasty (TJA) remains a clinically significant yet controversial issue. This study investigated the association between operating room ventilation systems and the risk of PJI in TJA patients. Method. We performed a retrospective observational study on consecutive patients undergoing primary total knee arthroplasty (TKA) and total hip arthroplasty (THA) from January 2013-September 2017 in two surgical facilities within a single institution, with a minimum 1-year follow-up. All procedures were performed by five board-certified arthroplasty surgeons. The operating rooms at the facilities were equipped with LAF and turbulent ventilation systems, respectively. Patient characteristics were extracted from clinical records. PJI was defined according to Musculoskeletal Infection Society criteria within 1-year of the index arthroplasty. A multivariate logistic regression model was performed to explore the association between LAF and risk of 1-year PJI, and then a sensitivity analysis using propensity score matching (PSM) was performed to further validate the findings. Results. A total of 6,972 patients (2,797 TKA, 4,175 THA) were included. The incidence of PJI within 1 year for patients from the facility without laminar flow was similar at 0·4% to that of patients from the facility with laminar flow at 0·5%. In the multivariate logistic regression analysis, after all confounding factors were taken into account, the use of LAF was not significantly associated with reduction of the risk of PJI. After propensity score matching, there was no significant difference in the incidence of PJI within 1 year for patients between the two sites. Conclusions. The use of LAF in the operating room was not associated with a reduced incidence of PJI following primary TJA. With an appropriate perioperative protocol for infection prevention, LAF does not seem to play a protective role in PJI prevention


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 104 - 104
1 Nov 2021
Camera A Tedino R Cattaneo G Capuzzo A Biggi S Tornago S
Full Access

Introduction and Objective. Difficult primary total knee arthroplasty (TKA) and revision TKA are high demanding procedures. Joint exposure is the first issue to face off, in order to achieve a good result. Aim of this study is to evaluate the clinical and radiological outcomes of a series of patients, who underwent TKA and revision TKA, where tibial tubercle osteotomy (TTO) was performed. Materials and Methods. We retrospectively reviewed a cohort of 79 consecutives TKAs where TTO was performed, from our Institution registry. Patients were assessed clinically and radiographically at their last follow-up (mean, 7.4 ± 3.7 years). Clinical evaluation included the Knee Society Score (KSS), the pain visual analogue scale (VAS), and range of motion. Radiological assessment included the evaluation of radiolucent lines, osteolysis, cortical bone hypertrophy, time of bone healing of the TTO fragment, and the hardware complication. Results. KSS raised from 40.7 ± 3.1 to 75 ± 4.3 (p < 0.0001). Knee flexion increased from 78.7 ± 9.9° to 95.0 ± 9.5° (p < 0.0001), and VAS improved from 7.9 ± 0.9 to 3.8 ± 1 (p < 0.0001). No signs of loosening or evolutive radiolucency lineswere found. Osteolytic areas around the stem were detected. No significant association was found between the implant design and the outcomes, while aseptic loosening showed significantly better results. Complications were: 4 painful hardware, 3 late periprosthetic infections, 1 extension lag of 5°, and 3 flexion lag. Conclusions. Our experience suggests the use of TTO to improve the surgical approach in difficult primary TKA or revision TKA. A strict surgical technique leads to good results with low risk of complications


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 51 - 51
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Outcomes for guided motion primary total knee arthroplasty (TKA) in obese patients are unknown. 1,684 consecutive patients underwent 2,059 primary TKAs with a second-generation guided motion implant between 2011–2017 at three European and seven US sites. Of 2,003 (97.3%) TKAs in 1,644 patients with BMI data: average age 64.5 years; 58.4% females; average BMI 32.5 kg/m2; 13.4% had BMI ≥ 40 kg/m2. Subjects with BMI ≥ 40 kg/m2 had longest length of hospital stay (LOS) at European sites; LOS similar at US sites. Subjects with BMI ≥ 40 kg/m2 (P=0.0349) had longest surgery duration. BMI ≥ 40 kg/m2 had more re-hospitalizations or post-TKA reoperations than BMI < 40 kg/m2 (12.7% and 9.2% at five-year post-TKA, P<0.0495). Surgery duration and long-term complication rates are higher in patients with BMI ≥ 40 kg/m2, but device revision risk is not elevated


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 83 - 83
1 Mar 2021
McAleese T Quinn M Graves S Clark G
Full Access

Abstract. Objectives. Patella resurfacing in primary total knee arthroplasty (TKA) remains a contentious issue. Australian rates of patellar resurfacing are 66.6%, significantly higher compared to UK rates of 8–15% and Swedish rates of 2%. Resurfacing has gained popularity in Australia since registry data has shown decreased revision rates with no increase in patellar component related complications. We present for discussion an analysis of 113,694 total knee arthroplasties using commonly implanted prostheses in the UK. Methods. We included all TKA's since the Australian register's conception on 01/09/1999 for a primary diagnosis of osteoarthritis involving the use of either the Triathlon or Duracon implant with and without patellar components. The primary outcome of the study was time to revision for Triathlon's resurfaced and non-resurfaced prosthesis compared to the Duracon's equivalent data. We also analysed the reasons for revision between the 4 groups, type of revision and complication rates. We then compared minimally stabilised and posterior stabilised prostheses. Results. The cumulative revision rate for Triathlon prostheses with resurfacing after 12 years was 3.2% (95% CI, 2.9% to 3.6%) compared to 5.6% (95% CI, 5.0% to 6.2%) without resurfacing. Duracon's equivalent data was 6.3% with resurfacing and 5.9% without resurfacing. Triathlon prosthesis with resurfacing have much lower rates of revision due to loosening, patellofemoral pain, patellar erosion compared to unresurfaced Triathlon prostheses. Conclusion. Triathlon with re-surfacing has lower revision rates regardless of age or BMI. Previous concerns regarding patellofemoral loosening, tibial wear, maltracking relate to Duracon only, indicating the importance of implant specific studies. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 98 - 98
1 Mar 2021
Yaghmour KM Hossain F Konan S
Full Access

Abstract. Objective. In this systematic review we aim to analyse the economical impact of using Negative Pressure Wound Therapy (NPWT) in primary total knee arthroplasty (TKA). Methods. Four medical electronic databases were searched. Eligible studies included those investigating the costs of NPWT in primary TKA. Exclusion criteria included studies investigating cost of NPWT not related to primary TKA. We also excluded studies with poor scientific methodology. We retrieved and analysed data on dressing costs and hospital length of stay (LOS). Results. Three studies (359 patients) reported on dressing and associated health care costs, and two further studies (330 patients) reported on hospital LOS in primary TKA. The cost of NPWT ranged between £125 and £196; with an average cost of £155, compared to £23 for the regular surgical dressing. The hospital LOS in NWPT patients ranged from 1.9 – 3.8 days, while LOS in patients managed with regular surgical dressing ranged between 2.3 – 4.7 days. The hospital LOS accounted for delayed discharge due to wound complications. Any extended LOS secondary to medical comorbidities or for other reasons were not included here. Conclusion. Our pooled analysis found a decrease in hospital LOS from wound related problems when using NWPT instead of regular dressings after accounting for other variables responsible for LOS. If the mean cost of overnight inpatient hospital stay for elective TKA is estimated as £275, the range of overnight admission cost for one TKA patient would be £522 - £1045 when NPWT dressing is used, and £632.5 - £1292 when using regular dressings. The cost savings from reduced LOS amounts to £110 - £247 per patient when NPWT is used. We hypothesize that in primary TKA patients with high risk of wound related problems that may delay discharge from hospital, there may be an overall cost saving when using NWPT dressings. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 14 - 14
1 Oct 2020
Mayman DJ Elmasry SS Chalmers BP Sculco PK Kahlenberg C Wright TE Westrich GH Imhauser CW Cross MB
Full Access

Introduction. Surgeons commonly resect additional distal femur during primary total knee arthroplasty (TKA) to correct a flexion contracture. However, the effect of joint line proximalization on TKA kinematics is unclear. Thus, our goal was to quantify the effect of additional distal femoral resection on knee extension and mid-flexion laxity. Methods. Six computational knee models with TKA-specific capsular and collateral ligament properties were implanted with a contemporary posterior-stabilized TKA. A 10° flexion contracture was modeled to simulate a capsular contracture. Distal femoral resections of +2 mm and +4 mm were simulated for each model. The knees were then extended under standardized torque to quantify additional knee extension achieved. Subsequently, varus and valgus torques of ±10 Nm were applied as the knee was flexed from 0° to 90° at the baseline, +2 mm, and +4 mm distal resections. Coronal laxity, defined as the sum of varus and valgus angulation with respective torques, was measured at mid-flexion. Results. With +2 mm and +4 mm of distal femoral resection, the knee extended an additional 4°±0.5° and 8°±0.75°, respectively. At 30° and 45°of flexion, baseline laxity averaged 4.8° and 5.0°, respectively. At +2 mm resection, mean coronal laxity increased by 3.1° and 2.7° at 30° and 45°of flexion, respectively. At +4 mm resection, mean coronal laxity increased by 6.5° and 5.5° at 30° and 45° of flexion, respectively. Maximal increased coronal laxity for a +4 mm resection occurred at a mean 16° (range, 11–27°) of flexion with a mean increased laxity of 7.8° from baseline. Conclusion. While additional distal femoral resection in primary TKA increases knee extension, the consequent joint line elevation induces up to 8° of coronal laxity in mid-flexion in this computational model. As such, posterior capsular release prior to resecting additional distal femur to correct a flexion contracture should be considered


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 62 - 62
1 Oct 2020
Garceau SP Warschawski YS Tang A Sanders EB Schwarzkopf R Backstein D
Full Access

Introduction. The effect of using thicker liners in primary total knee arthroplasty (TKA) on functional outcomes and aseptic failure rates remains largely unknown. As such, we devised a multicenter study to assess both the clinical outcomes and survivorship of thick vs thin liners after primary TKA. Methods. A search of our institutional databases was performed for patients having undergone bilateral (simultaneous or staged) primary TKA with similar preoperative and surgical characteristics between both sides. Two cohorts were created: thick liners and thin liners. Outcomes collected were as follows: change in Knee Society Score (DKSS), change in range of motion, and aseptic revision. Ad hoc power analysis was performed for DKSS (α ¼ 0.05; power ¼ 80%). Differences between cohorts were assessed. Results. 195 TKAs were identified for each cohort. DKSS and change in range of motion in the thin vs thick cohorts were similar: 51.4 vs 51.6 (P ¼ .86) and 11.1 vs 10.0 (P ¼ .66), respectively. No difference in aseptic revision rates were observed between thin and thick cohorts: all cause (4.1%, 3.1%; P ¼ .59), aseptic loosening (0.5%, 0.5%; P ¼ 1.0), instability (0.5%, 0.5%; P ¼ 1.0), all-cause revision for stiffness (3.1%, 2.1%; P ¼ .52), manipulation under anesthesia (2.1%, 2.1%; P ¼ 1.0), and liner exchange (0.5%, 0%; P ¼ .32). Conclusion. The results of this study suggest that both rates of revision surgery and clinical outcomes are similar for TKAs performed with thick and thin liners. Preoperative factors are likely to play an important role in liner thickness selection, and emphasis should be placed on ensuring sound surgical technique


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 30 - 30
1 Oct 2020
Lombardi AV Duwelius PJ Morris MJ Hurst JM Berend KR Crawford DA
Full Access

Background. The purpose of this study is to evaluate the early perioperative outcomes after primary knee arthroplasty with the use of a smartphone-based exercise and educational platform compared to a standard of care control group. Methods. A multicenter prospective randomized control trial was conducted evaluating the use of the mymobility smartphone-based care platform for primary total knee arthroplasty (TKA) and unicondylar knee arthroplasty (UKA). Patients in the control group (224 patients) received the respective institution's standard of care typically with formal physical therapy. Those randomized to mymobility treatment group (192 patients) were provided an Apple Watch and mymobility smartphone application. The treatment group was not initially prescribed physical therapy, but could if their surgeon determined it necessary. Early outcomes assessed included 90-day knee range of motion, KOOS Jr scores, 30-day single leg stance (SLS) time, Time up and Go (TUG) time and need for manipulation under anesthesia (MUA). There was no significant difference in age, BMI or gender between groups. Results. The 90-day knee flexion was not significantly different between controls (118.3±11.8) and mymobility (118.8 ±12) (p=0.7), nor was knee extension (1.6 ±3.5 vs. 1 ±3.1, p=0.16). KOOS Jr scores were not significantly different between control group (74 ±13.1) and mymobility group (71 ±13.3) (p=0.06). 30-day SLS was 22.3 ± 19.5 sec in controls and 24 ± 20.8 sec in mymobility (p=0.2). 30-day TUG times were 16 ± 44.3 sec in control and 15 ± 40.6 sec in mymobility (p=0.84). MUAs were performed in 4.02% of patients in the control group and 2.8% in the mymobility group (p=0.4%). Conclusion. The use of the mymobility care platform demonstrated similar early outcomes to traditional care models, while providing communication and insights into patient engagement with the care plan. There was no significant difference in 90-day range of motion or need for MUA