INTRODUCTION. Component impingement in total hip arthroplasty (THA) can cause implant damage or dislocation. Dual mobility (DM) implants are thought to reduce dislocation risk, but impingement on metal acetabular bearings may cause femoral component notching. We studied the prevalence of (and risk factors for) femoral notching with DM across two institutions. METHODS. We identified 37 patients with minimum 1-year radiographic follow-up after primary (19), revision (16), or conversion (2) THA with 3 distinct DM devices between 2012 and 2017. Indications for DM included osteonecrosis, femoral neck fracture, concomitant spinal or neurologic pathology, revision or conversion surgery, and history of prosthetic hip dislocation. Most recent radiographs were reviewed and assessed for notching. Acetabular anteversion and abduction were calculated as per Widmer (2004). Records were reviewed for dislocations and reoperations. RESULTS. 2/37 of cases demonstrated femoral component notching, best seen on Dunn views (available in 7/37 cases).
Background. Scapular notching causes glenoid bone loss after a reverse total shoulder arthroplasty (rTSA). The goal of this study was to assess the influence of prosthesis design on notching. Methods. Prospective, single surgeon cohort. Two different rTSA designs were consecutively implanted and compared: 25 Delta III rTSAs and 57 Delta Xtend rTSAs in 80 patients.
Introduction:
Introduction: In most of the reported series, scapular notching in inverse shoulder arthroplasty has been identified as a major problem. Therefore, a novel concept has been developed in order to minimize the incidence and the evolution (pathophysiology) of scapular notching. The current cohort study is now large enough to examine the results with special attention on notching. Methods: A dual peg design of the metaglene with CaP coating provides high primary and secondary stability. “Geometrical” notching is reduced by inferior (eccentric) fixation of the glenosphere on the metaglene, beveling of the medial part of the humeral inlay, and by the choice of three different sizes of the glenosphere (36, 39 and 42). “Biological” notching is addressed by inversion of the components: the epiphysis – as the mobile part – is metallic. Its contact to the scapula, should this occur, cannot lead to polyethylene wear. This study is a prospective multicentric study on Affinis Inverse and Affinis Fracture Inverse shoulder prosthesis (Mathys Ltd Bettlach, Switzerland), which is running in 7 European hospitals since December 2007. All cases but two (lost to follow-up) are included. Preoperative and all postoperative radiographs were reviewed.
This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture. Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk.Aims
Methods
Scapular notching is of concern in reverse shoulder arthroplasty and has been suggested as a cause of glenoid loosening. Our purpose was to analyze in a large series the characteristics and the consequences of the notch and then to enlighten the causes in order to seek some solutions to avoid it. 430 consecutive patients (457 shoulders) were treated by a reverse prosthesis for various etiologies between 1991 and 2003 and analyzed for this retrospective multicenter study. Adequate evaluation of the notch was available in 337 shoulders with a follow-up of 47 months (range, 24–120 months). The notch has been diagnosed in 62% cases at the last follow-up. Intermediate reviews show that the notch is already visible within the first postoperative year in 82% of these cases. Frequency and grade extension of the notch increase significantly with follow-up (p<
0.0001) but notch, when present, is not always evolutive. At this point of follow-up, scapular notch is not correlated with clinical outcome. There is a correlation with humeral radiolucent lines, particularly in metaphyseal zones (p=0.005) and with glenoid radiolucent lines around the fixation screws (p=0.006). Significant preoperative factors are: cuff tear arthropathy (p=0.0004), muscular fatty infiltration of infraspinatus (p=0.01), narrowing of acromio-humeral distance (p<
0.0001) and superior erosion of the glenoid (p=0.006). It was more frequent with superolateral approach than with deltopectoral approach (p<
0.0001) and with standard cup than with lateralized cup (p=0.02). We conclude that scapular notching is frequent, early and sometimes evolutive but not unavoidable. Preoperative superior glenoid erosion is significantly associated with a scapular notch, possibly due to the surgical tendency to position the baseplate with superior tilt and/or in high position which has been demonstrated to be an impingement factor. Preoperative radiographic planning and adapted glenoid preparation are of concern.
The clinical impact of scapular notching is controversial. Some reports suggest it has no impact while others have demonstrated it does negatively impact clinical outcomes. The goal of this clinical study is to analyze the pre- and post-operative outcomes of 415 patients who received rTSA with one specific prosthesis (Equinoxe; Exactech, Inc). 415 patients (mean age: 72.2yrs) with 2 years minimum follow-up were treated with rTSA for CTA, RCT, and OA by 8 fellowship trained orthopaedic surgeons. 363 patients were deemed to not have a scapular notch by the implanting surgeon at latest follow-up (72.1 yrs; 221F/131M) whereas 52 patients were deemed to have a scapular notch at latest follow-up (73.3 yrs; 33F/19M). Outcomes were scored using SST, UCLA, ASES, Constant, and SPADI metrics; active abduction, forward flexion, and internal/external rotation were also measured to quantify function. Average follow-up was 38.1 months (No Notch: 37.2; Notch: 44.4). A two-tailed, unpaired t-test identified differences (p<0.05) in pre-operative, post-operative, and pre-to-post improvements.Introduction
Methods
There has been increased focus on understanding the risk factors associated with scapular notching in reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the effect of scapular morphology and surgical technique on the occurrence of scapular notching using the notching index as a comprehensive predictive tool. Ninety-one patients treated with a primary RSA were followed for a minimum of 24 months. Using a previously published notching index formula ((PSNA × 0.13) + (PGRD)), a notching index value for all patients was calculated. Radiographic assessment of patients were grouped by Nerot grade of scapular notching, group mean differences for prosthetic scapular neck angle (PSNA), peg glenoid rim distance (PGRD), preoperative scapular neck angle (SNA), notching index and clinical outcomes were compared.Background
Methods
The intact femur geometry was derived from a CT dataset of a cadaveric femur and CT numbers were converted into a realistic distribution of material properties. The FE intact mesh was based on an experimentally validated mesh of a human femur. The femur was segmented into 22 neck sections. The loading condition was modelled to represent an instant at 10% of gait where all muscle forces were included. The femoral neck regions were compared between the models to evaluate the effect of notch sizes on stress distribution. Maximum tensile stresses were compared to the ultimate tensile stress (UTS) of cortical and cancellous bone.
Hip resurfacing has many advantages such as proximal bone conservation and easy revision including conversion to total hip arthroplasty. The major complication in the hip resurfacing is notching at the lateral cortical bone and fracture of the neck. In this research, we simulated the range of direction of reaming without causing notch. One left femur model was used for the simulation. The femoral head was fitted by a sphere and the origin of Cartesian coordinate was set at the center of the sphere. The simulation was made by imposing a cylindrical cut to the femoral head in varying direction and location. The existence of notching was decided comparing the maximum distance from reaming axis to neck section contour and the radius of cylindrical cut. If the maximum distance is bigger than the radius of cut, the notching exists and vice versa. We simulated existence of notching by varying inclination(α) from 20 to 70 degrees, anteversion(β) from 0 to 30 degree and depth passing through the head center(d) from 0 to 5mm. The implant used for the simulation was Durom®, Zimmer©. We selected the implant size that is close to the fitted sphere of femoral head. No notching was made for any direction when the depth d was less than 2mm. When the depth was 3mm, notching did not generate in the range of α from 43 degrees to 60 degrees and β from 0 to 25 degrees. When the range of depth was from 4mm to 5mm, notching did not generate in ranges of α from 41 degrees to 60 degrees and β from 0 to 29 degrees. The no-notching angle range had tendency increasing slightly when the depth was increased. The angle between the stem of the implant and the neck shaft axis without notching can be calculated from the angle α. When the depth was from 4mm to 5mm, the corresponding angle between stem of implant and the shaft axis was from 120 degrees to 139 degrees.
Fourteen hips with osteoarthritis had femoral head blood flow measured with laser Doppler flowmeter while undergoing during total hip replacement through a modified lateral approach. Mean age sixty-five years (48–77); eight males &
six females. Two measurements were taken within the femoral head one after anterior hip dislocation and one after simulated notching of the femoral neck. All hips had a significant decrease in blood flow with a median percentage decrease of 76% (range 4.4–90.4). During surface arthroplasty of the hip, notching of the femoral neck may not only mechanically weaken the bone but also put the femoral head at risk of osteonecrosis. To evaluate femoral head blood supply in patients with osteoarthrtis of the hip undergoing simulated notching of the femoral neck during total hip replacement and its potential implications in hip resurfacing. During surface arthroplasty of the hip, notching of the femoral neck may not only mechanically weaken the femoral neck but also put the femoral head at risk of osteonecrosis and subsequent femoral loosening. It would appear that the retinacular vessels (extraosseous blood supply) are as important in the arthritic femoral head as they are in the nonarthritic state, contradicting the notion that arthritic femoral heads in humans rely mainly on an intraosseous blood supply. Fourteen hips with a diagnosis of degenerative arthritis had femoral head blood flow measured with laser Doppler flowmeter while undergoing during total hip replacement through a modified lateral approach. With the femoral head exposed and leg in neutral position, a 3.5mm drill hole was made into the anterior lateral quadrant and the fiber optic probe of the laser Doppler flowmeter (Moor Instruments, Wilmington Delaware, 20mW laser, wavelength 780nm) was inserted. Mean age was sixty-five years (48–77). Eight males and six females. Two measurements were taken one after anterior hip dislocation and one after simulated notching of the femoral neck. All but four hips had a significant decrease of more than 50% in blood flow after neck notching with a median percentage change of 76% (range 4.4–90.4), p<
0.001.
This study was designed to determine the risk of femoral neck fracture after anterior or posterior notching of the femoral neck. The anterior femoral neck is under tensile forces during gait similarly to the superior neck [6].
We tested the femora flexed at 25° flexion to simulate loading as seen during stair ascent. [3] The posterior 5mm notched femoral necks were tested in extension to simulate sporting activities like running. The results were compared to the control group in neutral alignment using a one- way ANOVA:
Neutral (Control) 4303.09 ± 911.04N Superior 5mm 2423.07 ± 424.16N p=0.003 Anterior 5mm in 25° flexion 3048.11 ±509.24N p=0.087 Posterior 5mm in 25° extension3104.61±592.67N p=0.117 The anterior 5mm notch tested in single-leg stance and anterior notch in flexion displayed lower compressive loads to failure (3374.64N and 3048.11N). The mean load to failure value for the posterior 5mm notches in extension was 3104.62N compared to 4303.09N for the control group. Our data suggests that anterior and posterior 2mm notches are not significantly weaker in axial compression. The anterior 5mm notches was not significant in axial compression (p=0.38), but trended towards significance in flexion (p=0.087). A 5mm posterior notch was not significant. (p=0.995, p=0.117). The 5mm superior notch group was significantly weaker with axial compression supporting previous published data (p=0.003).
Despite the high success rates of Reverse Shoulder replacements, complications of instability & scapular notching are a concern. Factors reducing relative motion of implant to underlying bone which include lateral offset to centre of rotation, screw & central peg insertion angle and early osteo-integration are maximized in the Trabecular Metal Reverse total shoulder system. We present clinico-radiological outcomes over 72 months. Analysis of a single surgeon series of 140 Reverse total shoulder replacements in 135 patients was done. Mean age was 72(range 58– 87 yrs); 81 females: 54 males. Indications were Rotator cuff arthropathy {n= 88} (63%); Osteo-arthritis with dysfunctional cuff {n= 22}(15%); post-trauma{n=23} (15%); revision from hemiarthroplasty {n=3} (2.4%) and from surface replacement {n=4} (2.8%) All patients were assessed using pre-operative Constants and Oxford scores and clinical & radiographic reviews with standard X-Rays at 6 weeks, 3, 6,12 months and yearly thereafter. X rays included an AP view in 45 degrees of external rotation and modified axillary view. Inferior Scapular notching using the Nerot-Sirveaux grades and Peg Glenoid Rim Distance were looked into by a consultant musculoskeletal radiologist/ Orthopaedic surgeon/ Senior Fellow (post CCT) or a specialist Trainee (ST4 and above). Pain on the visual analogue scale decreased by 98% (9.1 to 0.8) (p<0.01). Constant score improved by 81.8% (12.4 to 68.1) (p<0.05), Oxford shoulder score by 76.7% (56 to 13) (p<0.05). 95.6% of Humeral stems had no radiolucent lines and 4.4% had < 2mm of lucency. Scapular notching was calculated using Sirveaux grades with Peg scapular base angle distance (PSBA) measurements on PACS with Siemens calibration (grade 1= 4 (2.8%); grade 2 =1; grade 3 =0; grade 4=0). 3.57% showed radiographic signs of scapular notching at 72 months. Range of Peg Glenoid Rim Distance was 1.66 to 2.31 cm. Power analysis showed 65 patients were needed to have an 80% power to detect relation of Peg Glenoid Rim Distance to Scapular notching. A likelihood ratio test from Logistic regression model to check correlation of Peg Glenoid Rim Distance to Scapular notching gave a p value of 0.0005. A likelihood ratio from Logistic regression gave a p value of 0.0004 for Infraglenoid Scapular spurs. Highest incidence of spurring was seen in Reverse Total Shoulder Replacements done for Trauma and lowest in patients who got the procedure for Osteoarthritis. Complications included two glenosphere revisions; two stitch abscesses and two Acromial fractures in patients who had a fall two years after the procedure. Improved surgical outcomes can be attributed to surgical technique and implant characteristics. Trabacular metal promotes early osteointegration which resists shearing action of Deltoid on Glenoid component. This allows early mobilisation. Deltoid split approach preserves integrity of Subscapularis and Acromial osteotomy and lateral clavicle excision improve exposure and prevent Acromion fracture. Positioning the Glenoid component inferiorly on the Glenoid decreases incidence of Scapular notching. Our mid-term validated outcomes are promising with only 3.57% Grade I/II radiographic signs of scapular notching. Long term studies (10 year follow ups) are necessary to confirm its efficacy.
A three dimensional femoral finite element model was constructed and molded with a femoral component constructed from the dimensions of a Birmingham Hip Resurfacing. The model was created with a superior femoral neck notch of increasing depths.
Surgeons performing hip resurfacing ante-vert and translate the femoral component anterior to maximize head/neck offset and educe impingement. The anterior femoral neck is under tensile forces during gait similarly to the superior neck [6]. This study was esigned to determine the risk of femoral neck fracture after anterior or posterior notching of the femoral neck.