Aims. Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial. Methods. The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival. Results. A total of 407 patients who underwent UKA were included in the study. The mean age of patients was 61.8 years, and the mean follow-up period of the patients was 91.7 months. The mean Knee Society Score (KSS) preoperatively and at the last follow-up were 64.2 and 89.7, respectively (p = 0.001). Overall, 28 patients (6.9%) with UKA underwent revision due to prosthesis loosening (16 patients), dislocation (eight patients), and persistent pain (four patients). Cox proportional hazards model analysis identified
Many factors can negatively impact acetabular component positioning including poor visualization, increased patient size, inaccuracies of mechanical guides, and inconsistent precision of conventional instruments and techniques, and changes in patient positioning. Improper orientation contributes to increased dislocation rates, leg length discrepancies, altered hip biomechanics, component impingement, acetabular component migration, bearing surface wear, and pelvic osteolysis thus affecting revision rates and long-term survivorship. Despite the established definitions of acetabular safe zones, recent analysis of U.S. Medicare THA data found dislocation rates during the first six months to be 3.9% for primary surgeries and 14.4% for revision surgeries. Accurate and precise acetabular component orientation during initial THA is an increasingly important factor in decreasing revision THA; a recent report cites instability and dislocation as the primary cause of revision accounting for 22.5% of cases. Larger femoral heads and alternative bearing couples are less tolerant of variation in acetabular orientation and thus are poor substitutes for proper acetabular component placement. Variability in acetabular orientation has been reported to have both an inter-surgeon and an intra-surgeon component; pre-surgical templating combined with intraop-erative measurements is subject to inconsistencies and errors. Current methods for determining acetabular orientation include preoperative imaging such as CT scans, intraoperative imaging such as plain radiographs and fluoroscopy, and intraoperative anatomical tests. Combining the concepts of patient-specific morphology (PSM) and quantitative technologies (QuanTech) such as computer-assisted navigation (CAN) has the potential to maximise range of motion and to further improve acetabular component orientation through improved accuracy and precision. PSM refers to the practice of allowing the form and structure of the patient’s hip joint to guide surgical reconstruction and component placement thus creating an individualised and more accurate “target zone”; unlike “safe zones,” PSM does not rely on averages. Although gross anatomic changes may make it difficult to use PSM, certain structures may be used as guide-posts for orientation, alignment, and stability in most patients. At present, there are three options when considering anatomic landmarks as guides for acetabular component placement: bony landmarks, soft tissue landmarks, or a combination. QuanTech has been shown to increase the precision of component placement by reducing intra-surgeon deviation. Some pitfalls of current CAN techniques result from maintaining camera line of sight during surgery, registration process, and pin placement. Performing THA using smaller incisions can impose additional complications as well as risks for errors in component positioning; QuanTech has the potential to provide greater visualization and precision, thus decreasing the impact of those constraints. THA has become one of the most common and successful orthopaedic procedures; its efficacy at relieving pain and its ability to help patients have improved quality of life is without dispute yet results continue to vary with inter-surgeon and intra-surgeon differences. As the population needing THA increases, the prevalence of complications and problems will increase, even if the percentage of complications decreases. Coupling PSM with QuanTech such as CAN may allow the surgeon to decrease variability and more consistently implant THA components based on each patient’s individualized requirements. The goal of combining PSM and CAN is to further reduce inter-and intra-surgeon variation, thereby decreasing outliers, complications, and revision rates, and possibly narrowing the gap between specialist and generalist. More accurate and precise acetabular component orientation correlates with better hip biomechanics, translating into better function, fewer dislocations, fewer impingements, maximized safe range of motion, less wear, and therefore less aseptic loosening and improvements in survivorship of primary THA. Decreasing revision rates, combined with the benefits listed above, could translate into increased THA survivorship, improved patient satisfaction, and decreased economic burden on the entire healthcare system.
The material and design of knee components can have a considerable effect on the contact characteristics of the tibial post. This study aimed to analyze the stress distribution on the tibial post when using different grades of polyethylene for the tibial inserts. In addition, the contact properties of fixed-bearing and mobile-bearing inserts were evaluated. Three different grades of polyethylene were compared in this study; conventional ultra high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (HXLPE), and vitamin E-stabilized polyethylene (VEPE). In addition, tibial baseplates with a fixed-bearing and a mobile-bearing insert were evaluated to understand differences in the contact properties. The inserts were implanted in neutral alignment and with a 10° internal malrotation. The contact stress, von Mises stress, and equivalent plastic strain (PEEQ) on the tibial posts were extracted for comparison.Aims
Methods
Ligament reconstruction following multi-ligamentous knee injuries involves graft fixation in bone tunnels using interference screws (IS) or cortical suspensory systems. Risks of IS fixation include graft laceration, cortical fractures, prominent hardware, and inability to adjust tensioning once secured. Closed loop suspensory (CLS) fixation offers an alternative with fewer graft failures and improved graft-to-tunnel incorporation. However, graft tensioning cannot be modified to accommodate errors in tunnel length evaluation. Adjustable loop suspensory (ALS) devices (i.e., Smith & Nephew Ultrabutton) address these concerns and also offer the ability to sequentially tighten each graft, as needed. However, ALS devices may lead to increased graft displacement compared to CLS devices. Therefore, this study aims to report outcomes in a large clinical cohort of patients using both IS and CLS fixation. A retrospective review of radiographic, clinical, and patient-reported outcomes following ligament reconstruction from a Level 1 trauma centre was completed. Eligible patients were identified via electronic medical records using ICD-10 codes. Inclusion criteria were patients 18 years or older undergoing ACL, PCL, MCL, and/or LCL reconstruction between January 2018 and 2020 using IS and/or CLS fixation, with a minimum of six-month post-operative follow-up. Exclusion criteria were follow-up less than six months, incomplete radiographic imaging, and age less than 18 years. Knee dislocations (KD) were classified using the Schenck Classification. The primary outcome measure was implant removal rate. Secondary outcomes were revision surgery rate, deep infection rate, radiographic fixation failure rate, radiographic
The periclavicular space is a conduit for the brachial plexus and subclavian-axillary vascular system. Changes in its shape/form generated by alteration in the anatomy of its bounding structures, e.g. clavicle malunion, cause distortion of the containing structures, particularly during arm motion, leading to syndromes of thoracic outlet stenosis etc., or alterations of scapular posture with potential reduction in shoulder function. Aim of this study was developing an in vitro methodology for systematic and repeatable measurements of the clinically poorly characterized periclavicular space during arm motion using CT-imaging and computer-aided 3D-methodologies. A radiolucent frame, mountable to the CT-table, was constructed to fix an upper torso in an upright position with the shoulder joint lying in the isocentre. The centrally osteotomized humerus is fixed to a semi-circular bracket mounted centrally at the end of the frame. All arm movements (ante-/retroversion, abduction/elevation, in-/external rotation) can be set and scanned in a defined and reproducible manner. Clavicle fractures healed in
Periprosthetic femoral fractures are increasingly seen in recent years, adding considerable burden to the National Health Service. These require complex revision or fixation and prolonged post-operative care, with significant morbidity with associated costs. The purpose of this study was to assess whether the size of femoral cement mantle is associated with periprosthetic femoral fractures (PPF). This retrospective study was carried out on a cohort of 49 patients (Fracture Group - FG) who previously had a revision procedure following a proximal PPF between 2010 and 2021. Inclusion criteria – all primary cemented total hip replacements (THR). Exclusion criteria – complex primary THR, any implant
The purpose of this study is to evaluate risk factors for distal construct failure (DCF) in posterior spinal instrumented fusion (PSIF) in adolescent idiopathic scoliosis (AIS). We observed an increased rate of DCF when the pedicle screw in the lowest instrumented vertebra (LIV) was not parallel to the superior endplate of the LIV, however this has not been well studied in the literature. We hypothesise a more inferiorly angled LIV screw predisposes to failure and aim to find the critical angle that predisposes to failure. A retrospective cohort study was performed on all patients who underwent PSIF for AIS at the Starship Hospital spine unit from 2010 to 2020. On a lateral radiograph, the angle between the superior endplate of the LIV was measured against its pedicle screw trajectory. Data on demographics, Cobb angle, Lenke classification, instrumentation density, rod protrusion from the most inferior screw, implants and reasons for revision were collected. Of 256 patients, 10.9% (28) required at least one revision. The rate of DCF was 4.6% of all cases (12 of 260) and 25.7% of revisions were due to DCF. The mean trajectory angle of DCF patients compared to all others was 13.3° (95%CI 9.2° to 17.4°) vs 7.6° (7° to 8.2°), p=0.0002. The critical angle established is 11°, p=0.0076. Lenke 5 and C curves, lower preoperative Cobb angle, titanium only rod constructs and one surgeon had higher failure rates than their counterparts. 9.6% of rods protruding less than 3mm from its distal screw disengaged. We conclude excessive inferior trajectory of the LIV screw increases the rate of DCF and a screw trajectory greater than 11° predisposes to failure. This is one factor that can be controlled by the surgeon intraoperatively and by avoiding
Aims. The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. Methods. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. Results. Five shoulders underwent revision surgery (3.5%); three for rotator cuff failure, one for infection, and one for component
Introduction. Total knee replacement (TKR) is an established and effective surgical procedure in case of advanced osteoarthritis. However, the rate of satisfied patients amounts only to about 75 %. One common cause for unsatisfied patients is the anterior knee pain, which is partially caused by an increase in patellofemoral contact force and abnormal patellar kinematics. Since the malpositioning of the tibial and the femoral component affects the interplay in the patellofemoral joint and therefore contributes to anterior knee pain, we conducted a computational study on a cruciate-retaining (CR) TKR and analysed the effect of isolated femoral and tibial component malalignments on patellofemoral dynamics during a squat motion. Methods. To analyse different implant configurations, a musculoskeletal multibody model was implemented in the software Simpack V9.7 (Simpack AG, Gilching, Germany) from the SimTK data set (Fregly et al.). The musculoskeletal model comprised relevant ligaments with nonlinear force-strain relation according to Wismans and Hill-type muscles spanning the lower extremity. The experimental data were obtained from one male subject, who received an instrumented CR TKR. Muscle forces were calculated using a variant of the computed muscle control algorithm. To enable roll-glide kinematics, both tibio- and patellofemoral joint compartments were modelled with six degrees of freedom by implementing a polygon-contact-model representing the detailed implant surfaces. Tibiofemoral contact forces were predicted and validated using data from experimental squat trials (SimTK). The validated simulation model has been used as reference configuration corresponding to the optimal surgical technique. In the following, implant configurations, i.e. numerous combinations of relative femoral and tibial component alignment were analysed:
Aims. Appropriate acetabular component placement has been proposed for prevention of postoperative dislocation in total hip arthroplasty (THA). Manual placements often cause outliers in spite of attempts to insert the component within the intended safe zone; therefore, some surgeons routinely evaluate intraoperative pelvic radiographs to exclude excessive acetabular component
Recurrent dislocation following total hip arthroplasty (THA) is a complex, multifactorial problem that has been shown to be the most common indication for revision THA. At our center, we have tried to approach the unstable hip by identifying the primary cause of instability and correcting that at the time of revision surgery. Type 1:.
To assess screw
Recurrent dislocation following total hip arthroplasty (THA) is a complex, multifactorial problem that has been shown to be the most common indication for revision THA. At our center, we have tried to approach the unstable hip by identifying the primary cause of instability and correcting that at the time of revision surgery. Type 1:
Recurrent dislocation following total hip arthroplasty (THA) is a complex, multifactorial problem that has been shown to be the most common indication for revision THA. At our center, we have tried to approach the unstable hip by identifying the primary cause of instability and correcting that at the time of revision surgery. Type 1:
Management of recurrent instability of the hip requires careful assessment to determine any identifiable causative factors. While plain radiographs can give a general impression, CT is the best methodology for objective measurement. Variables that can be measured include: prosthetic femoral anteversion, comparison to contralateral native femoral anteversion, total offset from the medial wall of the pelvis to the lateral side of the greater trochanter, comparison to total offset on the contralateral side, acetabular inclination, & acetabular anteversion. Wera et al describe potential causes of instability. These are typed into I. Acetabular Component
Spezializing in subfields of Orthopaedics is common in anglo-american countries for more than 20 years. IThe aim of this paper is to demonstrate the necessity of fellowship programms in extremity orientated subfileds of orthopaedics. Analyzing the results of ankle arthrodesis performed by general orthopaedic surgeons campared to ankle arthrodesis performed by spezialized foot and ankle surgeons the difference in results will be demonstrated. Patients and methods. In 40 patients an ankle arthrodesis was performed between 1998 and 2012. Group A was formed by 20 consecutive patients treated by spezial trained Foot and Ankle surgeons and group B was formed by 20 patients treted by general orthopaedic surgeons. The average age in group A at the time of surgery was 59,9y (34 to79y) compared to 63,4y (41 to 80y) in group B. The average follow up was 34 months respectively 32 months after surgery. The study included a spezial questionnaire with the AOFAS score and rating of patients dissatisfaction. The successful healing of the arthrodesis was determied by using standardized radiographs, Furthermore a pedobarography, and a videoanalyzis of the walking was incuded. Results. All procedures in group A were performed using an anterior approach. Neither pseudarthroses, equinus or other malositions were detected in this group. In group B wurdenin 16 patients an anterior and in 4 patients a lateral approach was used. Complications included 3 pseudarthroses, 4 equinus
Introduction. Recurrent dislocation following total hip arthroplasty (THA) is a complex, multifactorial problem that has been shown to be the most common indication for revision THA. The purpose of this study was to classify causes of instability and evaluate outcomes based on an algorithmic approach to treatment. Methods. Two surgeons performed 77 consecutive revisions for instability. Patients had a mean of 2 (range, 0 to 6) prior operative attempts to resolve their instability. Subjects were divided into 6 types based on the etiology of instability: I)
There has recently been an increase in the number of hip replacement procedures performed through an anterior approach. Every procedure has a risk profile, and in the case of a new procedure or technique it is important to investigate the incidence of complications. The aim of this study is to identify the complications encountered in the first 100 patients treated with the minimally invasive anterior approach. This is a case series of the first 100 hips treated and were assessed for complications. These were classified according to the severity and outcome [1]. The 100 hip comprised of 98 patients; 46 males and 52 females with an average operation age on 70.1 (±9.38) years. There were 2 bilateral procedures. Specific patient selection criteria were used. All complications occurred within one month of surgery. Complications such as fracture, deep vein thrombosis (DVT), cup
Background:. Varus-valgus constrained (VVC) implants are used in cases of severe valgus deformity, attenuated medial collateral ligament and difficulty in balancing the medial and lateral gaps of the knee. The increased constraint has been postulated to lead to more stress at the bone-implant interface and early loosening. The objective of this study was to compare the wear characteristics of the polyethylene liner in VVC prosthesis with the posterior-stabilized (PS) prosthesis and identify the factors leading to more wear in the VVC tibial inserts. Methods:. This was a retrieval analysis of all VVC liners collected from patients who underwent revision surgery from 1999 to 2011. These patients were matched to another group with posterior-stabilized inserts who underwent revision in the same time period. These two groups of patients were similar in terms of their demographic data and implant dimensions. Inserts were divided into 16 zones and a microscopic analysis of surface damage was carried out. We determined overall damage with a scoring system. Pre-revisions radiographs were reviewed and analyzed for correlation with the wear profile. Results:. There was significantly more damage in the posts of the VVC group (13.0 ± 5.0, compared to 4.7 ± 1.9 in the PS group) (p < 0.001). There was no difference in the backside wear, or wear in the medial and lateral compartments. Within the VVC group, the total damage score and cold flow damage were significantly higher with excessive joint line changes (≥ 5 mm). The excessive joint line elevation was associated with rotational wear pattern of the post (p = 0.004). The total abrasion and pitting scores were also higher in knees without proper restoration of the limb alignment (> 3° varus or valgus). Femoral component
Introduction:. Recurrent dislocation following total hip arthroplasty (THA) is a complex, multifactorial problem that has been shown to be the most common indication for revision THA. The purpose of this study was to classify causes of instability and evaluate outcomes based on an algorithmic approach to treatment. Methods:. Two surgeons performed 77 consecutive revisions for instability. Patients had a mean of 2 years (range, 0 to 6) prior operative attempts to resolve their instability. Subjects were divided into 6 types based on the etiology of instability: I)