Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 50 - 50
1 Feb 2021
Sanchez E Schilling C Grupp T Giurea A Verdonschot N Janssen D
Full Access

Introduction. Cementless total knee arthroplasty (TKA) implants use an interference fit to achieve fixation, which depends on the difference between the inner dimensions of the implant and outer dimensions of the bone. However, the most optimal interference fit is still unclear. A higher interference fit could lead to a superior fixation, but it could also cause bone abrasion and permanent deformation during implantation. Therefore, this study aims to investigate the effect of increasing the interference fit from 350 µm to 700 µm on the primary stability of cementless tibial implants by measuring micromotions and gaps at the bone-implant interface when subjected to two loading conditions. Methods. Two cementless e.motion® tibial components (Total Knee System, B. Braun) with different interference fit and surface coating were implanted in six pairs of relatively young human cadaver tibias (47–60 years). The Orthoload peak loads of gait (1960N) and squat (1935N) were applied to the specimens with a custom made load applicator (Figure 1A). The micromotions (shear displacement) and opening/closing gaps (normal displacement) were measured with Digital Image Correlation (DIC) in 6 different regions of interest (ROIs - Figure 1B). Two General Linear Mixed Models (GLMMs) were created with micromotions and interfacial gaps as dependent variables, bone quality, loading conditions, ROIs, and interference fit implants as independent variables, and the cadaver specimens as subject variables. Results. No significant difference was found for the micromotions between the two interference fit implants (gait p=0.755, squat p=0.232), nor for interfacial gaps (gait p=0.474, squat p=0.269). In contrast, significant differences were found for the ROIs in the two dependent variables (p < 0.001). The micromotions in the anterior ROIs (AM and AL) showed fewer micromotions for the low interference fit implant (Figure 2). More closing gaps (negative values) were seen for all ROIs (Figure 3), except in AM ROI during squat, which showed opening gaps (positive values). The posterior ROIs (PM and PL) showed more closing than seen in the anterior ROIs (AM and AL) for both loading configurations. Discussion. The results presented here demonstrate that increasing the interference fit from 350 µm to 700 µm does not affect the micromotions at the implant-bone interface of tibial TKA. While micromotions values were all below the threshold for bone ingrowth (40 µm), closing gaps were quite substantial (∼−150 µm). Since cementless e.motion® TKA components with an interference fit of 350 µm had shown a survival rate of 96.2% after 8.3 years postoperatively, interfacial gaps can be expected to be within a threshold value that can guarantee good primary stability. Moreover, increasing the interference fit to 700 µm can be considered a good range for an interference fit. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 40 - 40
1 Feb 2017
Berahmani S Hendriks M Janssen D Verdonschot N
Full Access

The primary stability of an uncemented femoral total knee replacement component is provided by press-fit forces at the bone-implant interface. This press-fit is achieved by resecting the bone slightly larger than the inner dimensions of the implant, resulting in a so-called interference fit. Previous animal studies have shown that an adequate primary stability is required to minimize micromotions at the bone-implant interface to achieve bone-ingrowth, which provides the secondary (long-term) fixation. It is assumed that during implantation a combination of elastic and plastic deformation and abrasion of the bone will occur, but little is known about what happens at the bone-implant interface and how much interference fit eventually is achieved. Purpose of this study was therefore to assess the actual and effective interference fit and the amount of bone damage during implantation of an uncemented femoral knee component. In this study, five cadaveric distal femora were prepared and femoral knee components were implanted by an experienced surgeon. Micro-CT scans and conventional CT-scans were obtained pre- and post-implantation for geometrical measurements and to measure bone mineral density. In addition, the position of the implant with respect to the bone was determined by optical scanning of the reconstructions (Figure.1). By measuring the differences in surface geometry, assessments were made of the cutting error, the actual interference fit, the amount of bone damage, and the effective interference fit. Our analysis showed an average cutting error of 0.67± 0.17 mm, which pointed mostly towards bone under-resections. We found an average actual AP interference fit of 1.48± 0.27 mm, which was close to the nominal value of 1.5 mm. We observed combinations of bone damage and elastic deformation in all bone specimens (Figure. 2), which showed a trend to be related with bone density. Higher bone density tended to lead to lower bone damage and higher elastic deformation (Figure. 3). The results of the current study indicate different factors that interact while implanting an uncemented femoral knee component. This knowledge can be used to fine-tune design criteria of femoral components and obtain adequate primary stability for all patients in a more predictable way


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 238 - 238
1 Dec 2013
Berahmani S Janssen D Wolfson D De Waal Malefijt M Verdonschot N
Full Access

Pegs are often used in cementless total knee replacement (TKR) to improve fixation strength. Studies have demonstrated that interference fit, surface properties, bone mineral density (BMD) and viscoelasticity affect the performance of press-fit designs. These parameters also affect the insertion force and the bone damage occurring during insertion. We aimed to quantify the effect of the aforementioned parameters on the short-term fixation strength of cementless pegs. 6 mm holes were drilled in twenty-four human femora. BMD was measured using calibrated CT-scans, and randomly assigned to samples. Pegs were produced to investigate the effect of interference fit (diameters 6.5 and 7.6 mm), surface treatment (smooth and rough- porous-coating [friction coefficient: 1.4]) and bone relaxation (relaxation time 0 and 30 min) and interactions were studied using a DOE method. Two additional rough surfaced peg designs (diameters 6.2 and 7.3 mm) were included to scrutinize interference. Further, a peg based on the LCS Porocoat® (DePuy Synthes Joint Reconstruction, Leeds, UK) was added as a clinical baseline. In total seven designs were used (n = 10 for all groups). Pegs were inserted and extracted using an MTS machine (Figure 1), while recording force and displacement. Bone damage was defined as the difference between the cross-sectional hole area prior to and after the test. BMD and interference fit were significant factors for insertion force. BMD had a significant positive correlation with pull-out force and subsequent analyses were therefore normalised for BMD. . Pull-out force increased significantly with interference for both surface coatings at time 0 (p < 0.05). However, after 30 minutes the effect remained significant for rough pegs only (p < 0.05-Figure 2A). Pull-out force reduced significantly with roughness for both peg diameters at time 0 (p < 0.001). However, after 30 minutes the effect remained significant for small pegs only (p < 0.05-Figure 2A). The time dependant interaction was only significant for smooth pegs in both diameters (p < 0.05-Figure 2A). Additionally, the pull-out force increased with diameter in a non-linear manner for the rough pegs (Figure 2B). The two surface treatments were not significantly different to the clinical comparator. Interference fit was the only significant factor for bone damage. BMD was significant for insertion and pull-out forces, reinforcing the need to account for this factor in biomechanical studies and clinical practice. This study also highlights the importance of time in studying bone interactions, with surface treatment and interference showing different interaction effects with relaxation time. Although smooth pegs initially have a higher pull-out force, this effect reduces over time whereas the pullout force for rough pegs is maintained. Smooth pegs also show time sensitivity in relation to interference and the benefit of increased interference reduces over time, whereas it is maintained in rough pegs. This may be explained by different damage (compressive and abrasive) mechanisms associated with different surface treatments. In conclusion, BMD and interference fit are significant factors for initial fixation. Bone relaxation plays an important role as it reduces the initial differences between groups. Therefore, these findings should be strongly considered in the design development of cementless TKR


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 150 - 150
1 May 2016
Geraldes D Jeffers J Hansen U Amis A
Full Access

Most glenoid implants rely on centrally located large fixation features to avoid perforation of the glenoid vault in its peripheral regions [1]. Upon revision of such components there may not be enough bone left for the reinsertion of an anatomical prosthesis, resulting in a large cavity that resembles a sink hole. Multiple press-fit small pegs would allow for less bone resection and strong anchoring in the stiffer and denser peripheral subchondral bone [2], whilst producing a more uniform stress distribution and increased shear resistance per unit volume [3] and avoiding the complications from the use of bone cement. This study assessed the best combination of anchoring strength, assessed as the ratio between push in and pull out forces (Pin/Pout), and spring-back, measured as the elastic displacement immediately after insertion, for five different small press-fitted peg configurations (Figure 1, left) manufactured out of UHMWPE cylinders (5 mm diameter and length). 16 specimens for each configuration were tested in two types of Sawbones solid bone substitute: hard (40 PCF, 0.64 g/cm3, worst-case scenario of Pin) and soft (15 PCF, 0.24 g/cm3, worst-case scenario of spring-back and Pout). Two different interference-fits, Ø, were studied by drilling holes with 4.7 mm and 4.5 mm diameter (Ø 0.3 and Ø 0.5, respectively). A maximum Pin per peg of 50 N was defined, in order to avoid fracture of the glenoid bone during insertion of multiple pegs. The peg specimens were mounted into the single-axis screw-driven Instron through a threaded fixture. A schematic of the experimental set up is made available (Figure 1, centre). The peg was pushed in vertically for a maximum of 5 mm at a 1 mm/s rate, under displacement control, recording Pin. The spring-back effect was assessed by switching to load control and reducing the load to zero. The peg was then pulled out at a rate of 1 mm/s, recording Pout. The test profile is depicted in Figure 1 (right). Average Pout/Pin, spring back (in mm) and force-displacement curves for all 80 specimens tested are shown in Figure 2. These were split into groups according to the type of bone substitute and interference-fit, with the right column showing the average values for the Pin. High repeatability among samples of the same configuration tested is noted. Configurations #1, #3 and #5 all exceed the maximum Pin per peg for at least one type of bone. Configuration #2 has the lowest Pin of all (best thread aspect ratio), followed by configuration #4 (thinner threads). The peg configurations #4 and #2 had the highest Pin/Pout. The peg configurations with lowest spring-back after insertion were configuration #2 and #4. Interference fit of Ø 0.3 mm was shown to reduce Pin below maximum limit of 50 N without great influence in spring-back


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 130 - 130
1 Feb 2003
Stitson D Vendittoli P Bracy D Dalziel R
Full Access

Disturbance of lung function during hip arthroplasty surgery is well recognised and, until now, only reported secondary to femoral instrumentation. We present a case report of per-operative acute pulmonary embolism that followed the insertion of an intereference fit acetabular component during hip resurfacing arthroplasty. A subsequent prospective study of per-operative lung function revealed that 9 out of 10 patients experienced an increase in pulmonary shunt value of up to 30% following socket insertion. The changes in shunt values were significant (p=0.009). We have highlighted for the first time the significant physiological disturbances that occur upon insertion of solid interference fit acetabular components, which although apparently transient, may prove life threatening


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 229 - 229
1 May 2012
Yasui Y Takao M Matsushita T
Full Access

There have been few reports with efficient treatments for neglected distal tibiofibular syndesmosis disruption. Here we will report four cases of successful anatomical reconstruction with autologous gracilis tendon, using the interference fit anchoring (IFA) system. All four cases were males between 20 and 58 years of age at the time of surgery (mean age 36 years). The post-injury period to surgery was between 7 and 59 months (mean 20.1 months), with the consultation period being from 5 to 19 months (mean 9.5 months). Radiographs at the time of injuries were all malleolar fractures of pronation-external rotation (PE) stage 3 in the Lauge-Hansen classification. Stress tests for distal tibiofibular syndesmosis were positive in all cases (dilation more than 2 mm). Arthroscopic drilling was conducted in two cases with a cartilaginous injury of trochlea of talus. Distal tibiofibular syndesmosis was anatomically repositioned and was fixed with screws after bony and soft tissues within the tibiofibular syndesmosis were removed and fibular adhesion was dissected. Ipsilateral autologous gracilis tendon was passed through foramen in the insertion of the anterior inferior tibiofibular tendon on tibia and fibula, and was fixated using the IFA system. The preoperative Japanese society for surgery of the foot (JSSF) score was from 26 to 74 points (mean 43.5) and postoperative JSSF score was from 67 to 100 (mean 89.5). In a case where there was a poor outcome, five years of post injury had passed before the surgery. Although the JSSF score improved to 67 points postoperatively (from the preoperative score of 26) in this case, arthroscopic arthrodesis was conducted 5 months postoperatively due to persistent pain. Anatomical reconstruction with autologous gracilis tendon using the IFA system showed a favorable functional prognosis overall. However, there was a case with progressive degenerated changes of injured distal tibiofibular syndesmosis due to a prolonged post-injury period resulted in a poor outcome


Bone & Joint Research
Vol. 7, Issue 3 | Pages 226 - 231
1 Mar 2018
Campi S Mellon SJ Ridley D Foulke B Dodd CAF Pandit HG Murray DW

Objectives. The primary stability of the cementless Oxford Unicompartmental Knee Replacement (OUKR) relies on interference fit (or press fit). Insufficient interference may cause implant loosening, whilst excessive interference could cause bone damage and fracture. The aim of this study was to identify the optimal interference fit by measuring the force required to seat the tibial component of the cementless OUKR (push-in force) and the force required to remove the component (pull-out force). Materials and Methods. Six cementless OUKR tibial components were implanted in 12 new slots prepared on blocks of solid polyurethane foam (20 pounds per cubic foot (PCF), Sawbones, Malmo, Sweden) with a range of interference of 0.1 mm to 1.9 mm using a Dartec materials testing machine HC10 (Zwick Ltd, Herefordshire, United Kingdom) . The experiment was repeated with cellular polyurethane foam (15 PCF), which is a more porous analogue for trabecular bone. Results. The push-in force progressively increased with increasing interference. The pull-out force was related in a non-linear fashion to interference, decreasing with higher interference. Compared with the current nominal interference, a lower interference would reduce the push-in forces by up to 45% (p < 0.001 One way ANOVA) ensuring comparable (or improved) pull-out forces (p > 0.05 Bonferroni post hoc test). With the more porous bone analogue, although the forces were lower, the relationship between interference and push-in and pull-out force were similar. Conclusions. This study suggests that decreasing the interference fit of the tibial component of the cementless OUKR reduces the push-in force and can increase the pull-out force. An optimal interference fit may both improve primary fixation and decrease the risk of fracture. Cite this article: S. Campi, S. J. Mellon, D. Ridley, B. Foulke, C. A. F. Dodd, H. G. Pandit, D. W. Murray. Optimal interference of the tibial component of the cementless Oxford Unicompartmental Knee Replacement. Bone Joint Res 2018;7:226–231. DOI: 10.1302/2046-3758.73.BJR-2017-0193.R1


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 125 - 125
1 Apr 2019
Sanchez E Schilling C Grupp TM Verdonschot N Janssen D
Full Access

Introduction. Although cementless press-fit femoral total knee arthroplasty (TKA) components are routinely used in clinical practice, the effect of the interference fit on primary stability is still not well understood. Intuitively, one would expect that a thicker coating and a higher surface roughness lead to a superior fixation. However, during implant insertion, a thicker coating can introduce more damage to the underlying bone, which could adversely influence the primary fixation. Therefore, in the current study, the effect of coating thickness and roughness on primary stability was investigated by measuring the micromotions at the bone-implant interface with experimental testing. Methods. A previous experimental set-up was used to test 6 pairs of human cadaveric femurs (47–60 years, 5 females) implanted with two femoral component designs with either the standard e.motion (Total Knee System, B. Braun, Germany) interference fit of 350 µm (right femurs) or a novel, thicker interference fit of 700 µm (left femurs). The specimens were placed in a MTS machine (Figure 1) and subjected to the peak loads of normal gait (1960N) and squat (1935N), based on the Orthoload dataset for Average 75. Varus/valgus moments were incorporated by applying the loads at an offset relative to the center of the implants, leading to a physiological mediolateral load distribution. Under these loads, micromotions at the implant-bone interface were measured using Digital Image Correlation (DIC) at different regions of interest (ROIs – Figure 1). In addition, DIC was used to measure opening and closing of the implant-bone interface in the same ROIs. Results. After comparing the micromotions and opening of the two implant designs, we found no significant differences between the standard and novel coating. Loading was a significant factor for both opening (P<0.0001) and micromotions (P=0.019), where the squat produced higher micromotions than gait. Opening was seen anteriorly (MA, LA), and was higher during squat. Closing was noticed distally (MD, LD), particularly during gait (Figure 2). During gait (Figure 3), the highest micromotions were found in the posterior condyles (CM, MP), followed by the medial anterior region (MA). For squat, the largest micromotions were in the anterior flange (ANT), followed by the distal regions (LD, MD). Discussion. In the current study, the primary stability of the same implant with two different coating thicknesses was evaluated. The results demonstrate that increasing the coating thickness does not automatically influence the primary stability of a femoral TKA component. This is likely due to abrasion and damage of the underlying trabecular during implant insertion, which also was observed in previous experiments. The exact relation between coating thickness or interference fit and primary implant stability still remains subject to debate. Obviously, the primary implant stability is compromised when the interference fit is too low. However, the current results suggest that there is a threshold beyond which further improvement of the fixation is not possible. The exact magnitude of this threshold is unknown, and may depend on coating characteristics and bone quality, and requires further evaluation, possibly utilizing a hybrid approach of experimental and computational techniques


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 73 - 73
1 Feb 2017
Kirking B
Full Access

Shortened humeral stem implants can be advantageous as they preserve more of the patient's bone and are not limited by the canal for placement in the proximal body. However, traditional longer stems may help stabilize the implant through interaction with the dense cortical bone of the canal. We developed an FEA model to gage the contributions of design features such as stem length, coatings, and interference fit. Models were constructed in FEMAP and solved using the NX Nastran advanced nonlinear static solver. The Turon (DJO Surgical) implant geometry was imported from a Solidworks CAD file and bone geometry was taken from a statistical shape model by Materialise representing the mean humeral geometry of 95 healthy humeri (avg age = 69.9 years). Implant and cancellous bone were considered to be linear homogeneous materials, and the cortical shell was modeled as orthotropic. Interference fits between the implant and cancellous bone surfaces were modeled using the gap feature of NX Nastran with friction coefficients corresponding to the surface finish. Loading was applied through a control node located at the center for the replacement head. Two loading conditions were analyzed, one representing torsion about the neck axis with a magnitude of 3140 Nm and one representing the peak load vector during activities of daily living. Using resection plane nodes at the intersection of the implant and bone, the histograms of micromotion and the associated 5. th. , 50. th. , and 95. th. percentile values were calculated. For a traditional length stem, the dominate effect on the predicted micromotion at the resection plane was the interference fit in the coating region. The contribution of a traditional length stem to resection plane micromotion was complex and depended on the presence of the stem and the amount of interference fit in the coating region


Bone & Joint Research
Vol. 9, Issue 7 | Pages 402 - 411
1 Aug 2020
Sanghani-Kerai A Coathup M Brown R Lodge G Osagie-Clouard L Graney I Skinner J Gikas P Blunn G

Aims. For cementless implants, stability is initially attained by an interference fit into the bone and osteo-integration may be encouraged by coating the implant with bioactive substances. Blood based autologous glue provides an easy, cost-effective way of obtaining high concentrations of growth factors for tissue healing and regeneration with the intention of spraying it onto the implant surface during surgery. The aim of this study was to incorporate nucleated cells from autologous bone marrow (BM) aspirate into gels made from the patient’s own blood, and to investigate the effects of incorporating three different concentrations of platelet rich plasma (PRP) on the proliferation and viability of the cells in the gel. Methods. The autologous blood glue (ABG) that constituted 1.25, 2.5, and 5 times concentration PRP were made with and without equal volumes of BM nucleated cells. Proliferation, morphology, and viability of the cells in the glue was measured at days 7 and 14 and compared to cells seeded in fibrin glue. Results. Overall, 2.5 times concentration of PRP in ABG was capable of supporting the maximum growth of cells isolated from the BM aspirate and maintain their characteristics. Irrespective of PRP concentration, cells in ABG had statistically significantly higher viability compared to cells in fibrin glue. Conclusion. In vitro this novel autologous gel is more capable of supporting the growth of cells in its structure for up to 14 days, compared to commercially available fibrin-based sealants, and this difference was statistically significant. Cite this article: Bone Joint Res 2020;9(7):402–411


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 59 - 59
1 Mar 2017
van Arkel R Ghouse S Ray S Nai K Jeffers J
Full Access

Implant loosening is one of the primary mechanisms of failure for hip, knee, ankle and shoulder arthroplasty. Many established implant fixation surfaces exist to achieve implant stability and fixation. More recently, additive manufacturing technology has offered exciting new possibilities for implant design such as large, open, porous structures that could encourage bony ingrowth into the implant and improve long-term implant fixation. Indeed, many implant manufacturers are exploiting this technology for their latest hip or knee arthroplasty implants. The purpose of this research is to investigate if the design freedoms offered by additive manufacturing could also be used to improve initial implant stability – a precursor to successful long-term fixation. This would enable fixation equivalent to current technology, but with lower profile fixation features, thus being less invasive, bone conserving and easier to revise. 250 cylindrical specimens with different fixation features were built in Ti6Al4V alloy using a Renishaw AM250 additive manufacturing machine, along with 14 specimens with a surface roughness similar to a conventional titanium fixation surface. Pegs were then pushed into interference fit holes in a synthetic bone material using a dual-axis materials testing machine equipped with a load/torque-cell (figure 1). Specimens were then either pulled-out of the bone, or rotated about their cylindrical axis before being pulled out to quantify their ability to influence initial implant stability. It was found that additively manufactured fixation features could favourably influence push-in/pull-out stability in one of two-ways: firstly the fixation features could be used to increase the amount pull-out force required to remove the peg from the bone. It was found that the optimum fixation feature for maximising pull-out load required a pull-out load of 320 N which was 6× greater than the least optimum design (54 N) and nearly 3× the maximum achieved with the conventional surface (120 N). Secondly, fixation features could also be used to decrease the amount of force required to insert the implant into bone whilst improving fixation (figure 2). Indeed, for some designs the ratio of push-in to pull-out was as high as 2.5, which is a dramatic improvement on current fixation surface technology, which typically achieved a ratio between 0.3–0.6 depending on the level of interference fit. It was also found that the additively manufactured fixation features could influence the level of rotational stability with the optimum design resisting 3× more rotational torque compared to the least optimum design. It is concluded that additive manufacturing technology could be used to improve initial implant stability either by increasing the anchoring force in bone, or by reducing the force required to insert an implant whilst maintaining a fixed level of fixation. This defines a new set of rules for implant fixation using smaller low profile features, which are required for minimally invasive device design


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 43 - 43
1 Jan 2016
Berahmani S Janssen D Wolfson D De Waal Malefijt M Verdonschot N
Full Access

A durable biological fixation between implant and bone depends largely on the micro-motions [Pilliar et al., 1986]. Finite element analysis (FEA) is a numerical tool to calculate micro-motions during physiological loading. However, micromotions can be simulated and calculated in various ways. Generally, only a single peak force of an activity is applied, but it is also possible to apply discretized loads occurring during a continuous activity, offering the opportunity to analyze incremental micro-motions as well. Moreover, micro-motions are affected by the initial press-fit. We therefore aimed to evaluate the effect of different loading conditions and calculation methods on the micro-motions of an uncemented femoral knee component, while varying the interference-fit. We created an FE model of a distal femur based on calibrated CT-scans. A Sigma® Cruciate-Retaining Porocoat® (DePuy Synthes, Leeds, UK) was placed following the surgical instructions. A range of interference-fits (0–100 µm) was applied, while other contact parameters were kept unchanged. Micro-motions were calculated by tracking the projection of implant nodes onto the bone surface. We defined three different micro-motions measures: micro-motions between consecutive increments of a full loading cycle (incremental), micro-motions for each increment relative to the initial position (reference), and the largest distance between projected displacements, occurring during a discretized full cycle (resulting) (Fig. 1A). Four consecutive cycles of normal gait and squat movements were applied, in different configurations. In the first configuration, incremental tibiofemoral and patellofemoral contact forces were applied, which were derived from Orthoload database using inverse dynamics [Fitzpatrick et al., 2012]. Secondly, we applied the same loads without the patellofemoral force, which is often used in experimental set-ups. Finally, only the peak tibiofemoral force was applied, as a single loading instance. We calculated the average of micro-motions of all nodes per increment to compare different calculation techniques. The percentage of area with resulting micro-motions less than 5 µm was also calculated. The percentage of surface area was increased non-linearly when the interference fit changed from 0 to 100 µm particularly for squat movement. Tracking nodes over multiple cycles showed implant migration with interference-fits lower than 30µm (Fig. 1A). Loading configurations without the patellofemoral force, and with only the peak tibiofemoral force slightly overestimated and underestimated the resulting micro-motions of squat movement, respectively; although, the effect was less obvious for the gait simulation when no patella force was applied. Both incremental and reference micro-motions underestimated the resulting micro-motions (Fig. 1B). Interestingly, the reference micro-motions followed the pattern of the tibiofemoral contact force (Fig. 1B). The calculation technique has a substantial effect on the micro-motions, which means there is a room for interpretation of micro-motions analyses. This furthermore stresses the importance of validation of the predicted micro-motions against experimental set-ups. In addition, the minor effect of loading configurations indicates that a simplified loading condition using only the peak tibiofemoral force is suitable for experimental studies. From a clinical perspective, the migration pattern of femoral components implanted with a low interference fit stresses the role of an adequate surgical technique, to obtain a good initial stability


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 9 - 9
1 Feb 2021
Soltanihafshejani N Bitter T Janssen D Verdonschot N
Full Access

Introduction. The fixation of press-fit orthopaedic devices depends on the mechanical properties of the bone that is in contact with the implants. During the press-fit implantation, bone is compacted and permanently deformed, finally resulting in the mechanical interlock between implant and bone. For the development and design of new devices, it is imperative to understand these non-linear interactions. One way to investigate primary fixation is by using computational models based on Finite Element (FE) analysis. However, for a successful simulation, a proper material model is necessary that accurately captures the non-linear response of the bone. In the current study, we combined experimental testing with FE modeling to establish a Crushable Foam model (CFM) to represent the non-linear bone biomechanics that influences implant fixation. Methods. Mechanical testing of human tibial trabecular bone was done under uniaxial and confined compression configurations. We examined 62 human trabecular bone samples taken from 8 different cadaveric tibiae to obtain all the required parameters defining the CFM, dependent on local bone mineral density (BMD). The derived constitutive rule was subsequently applied using an in-house subroutine to the FE models of the bone specimens, to compare the model predictions against the experimental results. Results. The crushable foam model provided an accurate simulation of the experimental compression test, and was able to replicate the ultimate compression strength measured in the experiments [Figure 1]. The CFM was able to simulate the post-failure behavior that was observed in the experimental specimens up to strain levels of 50% [Figure 2]. Also, the distribution of yield strains and permanent displacement was qualitatively very similar to the experimental deformation of the bone specimens [Figure 3]. Conclusion. The crushable foam model developed in the current study was able to accurately replicate the mechanical behavior of the human trabecular bone under compression loading beyond the yield point. This advanced bone model enables realistic simulations of the primary fixation of orthopaedic devices, allowing for the analysis of the influence of interference fit and frictional properties on implant stability. In addition, the model is suitable for failure analysis of reconstructions, such as the tibial collapse of total knee arthroplasty. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 481 - 481
1 Dec 2013
Kurdziel M Wiater B Moravek J Pinkas D Wiater JM
Full Access

Purpose:. Glenoid loosening persists as a common cause of anatomic total shoulder arthroplasty (TSA) failure. Considering radiographic evidence of loosening as an endpoint, TSA has a reported survivorship of only 51.5% at 10 years. Component loosening may be related to cementation and it is postulated that poor cement penetration and heat-induced necrosis may partially be responsible. There is a growing interest among surgeons to minimize or abandon cement fixation and rely on biologic fixation to the polyethylene for long-term fixation. De Wilde et al. reported promising early clinical and radiographic results using a pegged, all-polyethylene ingrowth glenoid design implanted without cement. The goal of this study was to compare glenoid micromotion in an all-polyethylene, centrally fluted pegged glenoid using 3 cement fixation techniques. Materials and Methods:. Glenoid components (Anchor Peg Glenoid, Depuy Orthopaedics, Warsaw, IN, USA) (Figure 1) were implanted in polyurethane foam testing blocks with 3 different fixation methods (n = 5 per group). Group I glenoids were implanted with interference fit fixation with no added cement. Group II was implanted with a hybrid fixation, where only the peripheral pegs were cemented. Group III glenoids were fully cemented for implantation. Glenoid loosening was characterized according to ASTM Standard F-2028. The glenoid component and a 44 mm humeral head were mounted to a materials testing frame (858 Mini Bionix II, MTS Crop., Eden Prairie, MN, USA) with a 750N applied joint compressive force (Figure 1). A humeral head subluxation displacement of ± 0.5 mm was experimentally calculated as a value that simulates glenoid rim loading that may occur at higher load activities. For characterization of glenoid loosening, the humeral head was cycled 50,000 times along the superior-inferior glenoid axis, simulating approximately 5 years of device service. Glenoid distraction, compression, and superior-inferior glenoid migration were recorded with two differential variable reluctance transducers fixed to the glenoid prosthesis. Results:. All glenoid components completed the 50,000 cycles of humeral head translation successfully. With respect to glenoid distraction (Figure 2), interference fit fixation had significantly greater distraction compared to both hybrid and fully cemented fixation (p < 0.001). Hybrid fixation also displayed significantly higher distraction compared to fully cemented fixation (p < 0.001). In terms of glenoid compression (Figure 2), hybrid cementation had significantly greater compression compared to both interference-fit and fully cemented fixation (p < 0.001). Discussion:. This is the first biomechanics study comparing glenoid micromotion of a centrally fluted, pegged component using 3 different fixation techniques. Of all fixation methods, the fully cemented components displayed the least amount of motion in all parameters. Hybrid fixation exhibited lower distraction, higher compression, and comparable translation compared to interference-fit fixation. Results may indicate the differences in early motion and suggest little to no advantage of peripheral peg cementation over no cement with respect to initial fixation. Future studies are warranted to further evaluate interference-fit fixation as a viable option for implantation of a central fluted, all-polyethylene glenoid component


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 49 - 49
1 May 2019
Rajgopal A
Full Access

Management of severe bone loss in total knee arthroplasty presents a formidable challenge. This situation may arise in neglected primary knee arthroplasty with large deformities and attritional bone loss, in revision situations where osteolysis and loosening have caused large areas of bone loss and in tumor situations. Another area of large bone loss is frequently seen in periprosthetic fractures. Trabecular metal (TM) with its dodecahedron configuration and modulus of elasticity between cortical and cancellous bone offers an excellent bail out option in the management of these very difficult situations. Severe bone loss in the distal femur and proximal tibia lend themselves to receiving the TM cones. The host bone surfaces need to be prepared to receive these cones using a high speed burr. The cones acts as a filler with an interference fit through which the stemmed implant can be introduced and cemented. All areas of bone void is filled with morselised cancellous bone fragments. We present our experience of 64 TM cones (28 femoral, 36 tibial cones) over a 10-year period and our results and outcomes for the same. We have had to revise only one patient for recurrence of the tumor for which the cone was implanted in the first place. We also describe our technique of using two stacked cones for massive distal femoral bone loss and its outcomes. We found excellent osteointegration and new host bone formation around the TM construct. The purported role of possible resistance to infection in situations using the TM cones is also discussed. In summary we believe that the use of the TM cones offers an excellent alternative to massive allografts, custom and/or tumor implants in the management of massive bone loss situations


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 37 - 37
1 Jan 2019
Taylor MEC Wilcox RK Mengoni M
Full Access

Osteochondral (OC) grafting is one available method currently used to repair full thickness cartilage lesions with good results clinically when grafting occurs in patients with specific positive prognostic factors. However, there is poor understanding of the effect of individual patient and surgical factors. With limited tissue availability, development of Finite Element (FE) models taking into account these variations is essential. The aim of this study was to evaluate the effect of altering the material properties of OC grafts and their host environment through computer simulation. A generic FE model (ABAQUS CAE 2017) of a push-out test was developed as a press-fit bone cylinder (graft) sliding inside a bone ring (host tissue). Press-fit fixation was simulated using an interference fit. Overlap between host and graft (0.01mm–0.05mm) and coefficient of friction (0.3–0.7) were varied sequentially. Bone Young's moduli (YM) were varied individually between graft and host within the range of otherwise derived tissue moduli (46MPa, 82MPa, 123MPa). Increasing both overlap and frictional coefficient increased peak dislodging force independently (overlap: 490% & frictional coefficient: 176% across range tested). Increasing bone modulus also increased dislodging force, with host bone modulus (107%, 128%, and 140% increase across range, when Graft YM = 123MPa, 82 MPa, and 46MPa, respectively) having a greater influence than graft modulus (28%, 19% and 10% increase across range, when Host YM = 123 MPa, 82MPa and 46MPa, respectively). As anticipated increasing overlap and friction caused an increase in force necessary to dislodge the graft. Importantly, differentially changing the graft and host material properties changed the dislodging force indicating that difference between graft and host may be an important factor in the success or failure clinically of osteochondral grafting


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 41 - 41
1 Aug 2017
Meneghini R
Full Access

Cementless fixation in TKA has been inconsistently adopted since its early use but is increasing due to a number of factors, predominantly related to a demand for improved survivorship in younger patients. Modern biomaterials have demonstrated optimal bone ingrowth and have also contributed to a renewed confidence by surgeons to utilise cementless fixation in TKA. With a modern design and appropriate surgical technique, optimal mechanical stability of new designs have been demonstrated and can build upon the excellent long-term outcomes that have rivaled traditional cemented TKA. Paramount to obtaining successful long-term osseointegration and clinical survivorship with cementless fixation is an awareness of the past failure mechanisms to improve implant modern implant design, and should also guide meticulous surgical technique. A robust implant design with optimal surgical technique is critical to success when employing cementless fixation in TKA. The tried and true principles of sufficient mechanical stability to minimise micromotion of an osteoconductive implant surface with intimate contact against viable bone are essential to allow osseointegration and long-term survivorship. The surgical techniques and tips for “getting it right” include: 1.) Meticulous planar cuts - Prevention of saw blade deviation (particularly anterior femoral cortex and sclerotic medial tibial plateau), Appropriate tolerances in cutting guides (particularly 4-in-1 femoral cutting guide), Appropriate interference fit for tibial keel/stem, patella planar cut, Perfect planar cut on tibial surface confirmed with “4-corner test”. 2.) Implantation of components to maximise mechanical stability - Intimate implant contact with bone (minimizing gaps), Consider bone slurry to minimise gaps, Prevention of femoral component flexion with impaction, Ensure parallel position of tibial baseplate with tibial cut surface during impaction, Peripheral fixation on tibial baseplate, either screws or pegs, to provide supplemental fixation and stability in titanium tray designs


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 60 - 60
1 Apr 2017
Paprosky W
Full Access

Acetabular distraction for the treatment of chronic pelvic discontinuity was first described by Sporer and Paprosky. The authors advocate the posterolateral approach for exposure of the posterior ilium and posterior column, The patient is secured in the lateral decubitus position. Following a systematic approach to surgical exposure, acetabular component removal should be performed with “cup out” osteotomes resulting in minimal iatrogenic bone loss. Following component removal and confirmation of a chronic discontinuity determine the integrity of the remaining AS and PI columns. If porous metal augments are needed for primary stabilization, the augments are placed prior to cup insertion for reconstruction of the AS and/or PI column. Next, Kirschner (K) wires (size 2.4) are placed in the remaining AS and PI bone so that the distractor can be secured in an extra-acetabular position. The distractor is placed over the K-wires allowing for lateral or peripheral acetabular distraction and resultant medial or central compression at the discontinuity. With the distractor in an extra-acetabular position, hemispherical reamers are used until an interference fit is achieved between the native or augmented AS and PI columns. The acetabulum should be reamed on reverse to avoid excessive removal of host bone. When the proper acetabular component size has been reached, the reamer will disengage from the reamer handle and the reamer can be used as a surrogate acetabular shell; when the acetabulum is maximally distracted, the entire construct will move as a unit. Crushed cancellous allograft is used to bone graft the discontinuity and reamed on reverse. A revision tantalum cup is inserted with continual distraction using the distractor. Cement is applied to the augment surface prior to cup insertion in order to utilise the construct. Following cup insertion, the distractor and K-wires are removed. Adjuvant screw fixation is performed, with a minimum of 4 screws, and placing at least one of the screws inferiorly for fixation in the superior public ramus or ischium to prevent abduction failure of the construct. In the setting of severely osteoporotic bone and inadequate screw fixation, an augment placed posterosuperiorly can be used for supplemental fixation. This augment is also unitised to the cup with cement at the same time as the liner is cemented into the cup. Bone wax is placed over the exposed tantalum surface of the posterosuperior augment to minimise soft-tissue ingrowth into the augment


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 6 - 6
1 Apr 2018
Schulze C Vogel D Bader R Kluess D Haas H
Full Access

Introduction. Modern acetabular cups require a convenient bone stock for sufficient cup fixation. Thereby, fixation stability is influenced by the chosen interference fit of the acetabular cup, the cup surface structure, circularity of the reamed acetabulum and by the acetabular bone quality. The ideal implantation situation of the cup is commonly compromised by joint dysplasia and acetabular bone defects. The aim of the present experimental study was to characterise implant fixation of primary acetabular cups in case of definite acetabular cavity defects. Materials and Methods. For the experimental determination bone substitute blocks (100 × 100 × 50 mm) made of polymethacrylimide (PMI) foam with a density of 7 pcf were used. The created acetabular defect situations were derived from the defect classification according to Paprosky. The defect geometries in the PMI foam blocks were realised by a CNC drilling machine. Thereby the defects are described in the dorso-ventral direction by the angle α and in medio-lateral direction by the angle β (given as angle combination α/β) related to the centre of rotation of the reamed cavity. For the lever-out tests the defect types IIb and IIIa (each with different α and β angles) were considered and compared to the intact fixation situation. Therefore, a macrostructured titanium cup (Allofit, Zimmer GmbH, Wintherthur, Switzerland) with an outer diameter of 56 mm were displacement-controlled (v = 20 mm/min) pushed into the 2 mm diametric under reamed PMI-foam cavities. Three cups were inserted until the cup overhang pursuant to surgical technique was reached. Subsequently the cups were displacement-controlled (v = 20 mm/min) levered out via a rod which was screwed into the implant pole by perpendicular displacement (U. axial. ) of the rod in direction of the defect aperture. The lever-out moments were calculated by multiplying the first occurring force maximum (F. max. ) with the effective lever arm length (l. lever. ), whereby moments caused by the deadweight of the rod were considered. Primary stability was defined by the first maximum lever-out moment. Results. The calculated lever-out moments were in a range from 15.5 ± 1.4 Nm to 1.4 ± 0.5 Nm. Defects with a 90° dorso-ventral opening angle showed 57 ± 17% lower lever-out moments. Defects with a 120° dorso-ventral opening angle showed 80 ± 6% lower lever-out moments compared to the cup fixation into intact cavities. Moreover, medio-lateral angles greater than 20° reduced the lever-out moment by 79 ± 12% compared to the intact cavities. Conclusion. The determined lever-out moments underline the reduction of fixation stability of acetabular cup by loss of circumferential rim and absent of superior wall support of the acetabular bone. Thereby, the fixation stability is influenced by the degree of dorso-ventral and medio-lateral defect manifestation. Hence, the fixation stability depends on the cavity surface and in particular the surface of the bone-implant interface in the fixation zone of the acetabular cup Thus, dorso-ventral defect sizes with greater opening angle than 60° and medio-lateral defect sizes greater than 20° are critically for sufficient fixation of primary acetabular cup implants


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 129 - 129
1 Feb 2017
Garcia-Rey E Cimbrelo EG
Full Access

Background and aim. Total hip replacement (THR) in young patients has been associated to higher revision rates than in older population. Different conditions may lead to end-stage arthritis of the hip in these patients. We compared the clinical and radiological outcome of two different groups of young and very young patients who underwent a ceramic-on-ceramic THR. Patients and Methods. 120 hips were prospectively followed for a mean of 10.4 years (range, 5 to 17). 38 patients (46 hips) were less than 30 years old (group 1), and, 68 (74 hips) were between 31 and 40 years old (group 2). Weight (p<0.001) and physical activity level were greater in group 2 (p<0.001). Preoperative function (p=0.03) and range of mobility (p=0.03) were worse in group 1. Primary osteoarthritis was not found in any case. Rheumatoid juvenile arthritis was the most frequent diagnosis in group 1 and avascular necrosis of the femoral head in group 2. A femoral funnel-shaped type 1 according to Dorr was more frequent in group 2 (p=0.04). The same ceramic-on-ceramic uncemented THR was used in all cases. Screws for cup fixation were only used when strictly needed. We analysed the clinical results according to the Merle-D´Aubignè and Postel scale, the postoperative radiological reconstruction of the hip and the radiological appearance of cup loosening. Kaplan-Meier survivorship analysis was used to estimate the cumulative probability of not having a revision surgery. Results. Screw use required to obtain a secured interference fit of the acetabular component was found more frequently in group 1 (p=0.01). Postoperative pain (p=0.002) and function (p=0.002) were better in group 1. Mean acetabular abduction angle of the cup was greater in group 1 (p=0.03) and reconstruction to the hip rotation center according to Ranawat (p=0.01) was better in group 2. Placement of the acetabular component inside the Lewinnek´s zone and stem position were similar in both groups. No hips were revised due to complications related to ceramic or to stem loosening. Three cups were revised for aseptic loosening in group 1 and four in group 2. The survival rate for cup aseptic loosening at 15 years was 92.3% (95% CI: 83.7 to 100) for group 1 and 93.1% (95% CI: 85.3 to 99.9) for group 2 (Log rank, p=0.88). Conclusion. Ceramic-on-ceramic uncemented THR is an excellent option for young and very young patients. Despite worse preoperative conditions in patients under the age of 30 years, a similar clinical outcome was found in this series