Advertisement for orthosearch.org.uk
Results 1 - 20 of 144
Results per page:
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 35 - 35
1 Mar 2008
Xing S Boynton E
Full Access

The effect of conditioned media from implant revision membranes on tartrate resistant acid phosphatase (TRAP) secretion following PE exposure was investigated. Human Monocytes were cultured on PE/collagen coverslips, and 50 uls of culture media, conditioned media from implant revision membranes, or conditioned media from synovium was added. Cultured media were collected, and analyzed for TRAP activity. Statistical analysis showed significantly greater release of TRAP in the media with the supplement of the conditioned media from implant revision membranes, indicating that the unknown factors in the conditioned media could accelerate monocyte-macrophage TRAP secretion. Identifying and blocking of the factors would be beneficial for long-term implant performance. The purpose of this study was to investigate the effect of conditioned media from implant revision membranes on monocyte-macrophage tartrate resistant acid phosphatase (TRAP) secretion. Conditioned media from implant revision membranes significantly enhanced monocyte-macrophage TRAP secretion following PE exposure in vitro. Since TRAP has been related to bone resorption, identifying and blocking factors stimulating monocyte-macrophage TRAP section would be beneficial for preventing peri-implant bone resorption. Monocytes isolated from human blood were cultured on PE/collagen coverslips, and 50 uls of fresh culture media, conditioned media from implant revision membrane, or conditioned media from synovium was added at time zero, day two and four. Cultured media were collected at day two, four and six, and analyzed for TRAP activity. As previously reported the conditioned media from the revision membranes contained TRAP activity greater than synovial membranes. Therefore the accumulative TRAP activity after culturing macrophages with PE was corrected by subtracting TRAP activity measured in the conditioned media prior to DNA normalization. Statistical analysis showed significantly greater release of TRAP in media with addition of the conditioned media from implant revision membrane when compared with either conditioned media from synovium or fresh culture media (p< 0.01, n=3). This result indicates that certain unknown soluble factors in the conditioned media from implant revision membrane could accelerate monocyte-macrophage TRAP secretion. Since TRAP enzyme has been related to bone resorption, greater TRAP secretion could lead to peri-implant osteolysis and subsequent implant loosening. Identifying and blocking of those factors would be ultimately beneficial for implant long-term clinical performance. Funding: Canadian Orthopaedic Research Foundation and Arthritis Society


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 102 - 102
1 May 2016
Daniel J Ziaee H McMinn D
Full Access

Objectives. To examine mortality and revision rates among patients with osteoarthritis undergoing hip arthroplasty and to compare these rates between patients undergoing cemented or uncemented procedures and to compare outcomes between men undergoing stemmed total hip replacements and Birmingham hip resurfacing. Main outcome measures. Hip arthroplasty procedures were linked to the time to any subsequent mortality or revision (implant failure). Flexible parametric survival analysis methods were used to analyse time to mortality and also time to revision. Comparisons between procedure groups were adjusted for age, sex, American Society of Anesthesiologists (ASA) grade, and complexity. Results. Multivariable survival analyses identified a higher mortality rate for patients undergoing cemented compared with uncemented total hip replacement (adjusted hazard ratio 1.11, 95% confidence interval 1.07 to 1.16); conversely, there was a lower revision rate with cemented procedures (0.53, 0.50 to 0.57). These translate to small predicted differences in population averaged absolute survival probability at all time points. For example, compared with the uncemented group, at eight years after surgery the predicted probability of death in the cemented group was 0.013 higher (0.007 to 0.019) and the predicted probability of revision was 0.015 lower (0.012 to 0.017). In multivariable analyses restricted to men, there was a higher mortality rate in the cemented group and the uncemented group compared with the Birmingham hip resurfacing group. In terms of revision, the Birmingham hip resurfacings had a similar revision rate to uncemented total hip replacements. Discussion. There is a small but significant increased risk of revision with uncemented rather than cemented total hip replacement, and a small but significant increased risk of death with cemented procedures. It is not known whether these are causal relations or caused by residual confounding. Compared with uncemented and cemented total hip replacements, Birmingham hip resurfacing has a significantly lower risk of death in men of all ages. Previously, only adjusted analyses of hip implant revision rates have been used to recommend and justify use of cheaper cemented total hip implants. Our investigations additionally consider mortality rates and suggest a potentially higher mortality rate with cemented total hip replacements, which merits further investigation. These results have now been confirmed by other Centres as well. [1,2] Our findings agree with those of Kendal et al who confirm that those undergoing metal-on-metal hip resurfacing have reduced mortality in the long term (up to 10 years) compared with those undergoing total hip replacement and that this difference persisted after extensive adjustment for confounding factors. Although residual confounding is possible, the observed effect size is large


Bone & Joint Research
Vol. 12, Issue 6 | Pages 362 - 371
1 Jun 2023
Xu D Ding C Cheng T Yang C Zhang X

Aims. The present study aimed to investigate whether patients with inflammatory bowel disease (IBD) undergoing joint arthroplasty have a higher incidence of adverse outcomes than those without IBD. Methods. A comprehensive literature search was conducted to identify eligible studies reporting postoperative outcomes in IBD patients undergoing joint arthroplasty. The primary outcomes included postoperative complications, while the secondary outcomes included unplanned readmission, length of stay (LOS), joint reoperation/implant revision, and cost of care. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were calculated using a random-effects model when heterogeneity was substantial. Results. Eight retrospective studies involving 29,738 patients with IBD were included. Compared with non-IBD controls, patients with IBD were significantly more likely to have overall complications (OR 2.11 (95% CI 1.67 to 2.66), p < 0.001), medical complications (OR 2.15 (95% CI 1.73 to 2.68), p < 0.001), surgical complications (OR 1.43 (95% CI 1.21 to 1.70), p < 0.001), and 90-day readmissions (OR 1.42 (95% CI 1.23 to 1.65), p < 0.001). The presence of IBD was positively associated with the development of venous thromboembolism (OR 1.60 (95% CI 1.30 to 1.97), p < 0.001) and postoperative infection (OR 1.95 (95% CI 1.51 to 2.51), p < 0.001). In addition, patients with IBD tended to experience longer LOS and higher costs of care. Conclusion. The findings suggest that IBD is associated with an increased risk of postoperative complications and readmission after joint arthroplasty, resulting in longer hospital stay and greater financial burden. Surgeons should inform their patients of the possibility of adverse outcomes prior to surgery and make appropriate risk adjustments to minimize potential complications. Cite this article: Bone Joint Res 2023;12(6):362–371


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 16 - 16
23 Feb 2023
Tay M Bolam S Coleman B Munro J Monk A Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand. Unicompartmental knee arthroplasty (UKA) is effective for patients with isolated compartment osteoarthritis, however the procedure has higher revision rates. Long-term survivorship and accurate characterisation of revision reasons are limited by a lack of long-term data and standardised revision definitions. We aimed to identify survivorship, risk factors and revision reasons in a large UKA cohort with up to 20 years follow-up. Patient, implant and revision details were recorded through clinical and radiological review for 2,137 consecutive patients undergoing primary medial UKA across Auckland, Canterbury, Counties Manukau and Waitematā DHB between 2000 and 2017. Revision reasons were determined from review of clinical, laboratory, and radiological records for each patient using a standardised protocol. To ensure complete follow-up data was cross-referenced with the New Zealand Joint Registry to identify patients undergoing subsequent revision outside the hospitals. Implant survival, revision risk and revision reasons were analysed using Cox proportional-hazards and competing risk analyses. Implant survivorship at 15 years was comparable for cemented fixed-bearing (cemFB; 91%) and uncemented mobile-bearing (uncemMB; 91%), but lower for cemented mobile-bearing (cemMB; 80%) implants. There was higher incidence of aseptic loosening with cemented implants (3–4% vs. 0.4% uncemented, p<0.01), osteoarthritis (OA) progression with cemMB implants (9% vs. 3% cemFB/uncemMB; p<0.05) and bearing dislocations with uncemMB implants (3% vs. 2% cemMB, p=0.02). Compared with the oldest patients (≥75 years), there was a nearly two-fold increase in risk for those aged 55–64 (hazard ratio 1.9; confidence interval 1.1-3.3, p=0.03). No association was found with gender, BMI or ASA. Cemented mobile-bearing implants and younger age were linked to lower implant survivorship. These were associated with disease progression and bearing dislocations. The use of cemented fixed-bearing and uncemented mobile-bearing designs have superior comparable long-term survivorship


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 15 - 15
1 Jun 2023
Oomatia A Lu W Al Muderis M
Full Access

Introduction. Osseointegration has emerged as a promising alternative to rehabilitating with a traditional socket mounted prosthesis. Advantages have been reported to include improved functional mobility, better osseoperception, improved comfort, reduced pain, better biomechanical alignment and better gait, which all lead to a less restricted lifestyle and significantly improved quality of life. A major concern of the Osseointegrated approach lies in the risk of infections occurring from the permanent transcutaneous opening often referred to as the stoma. Several systematic reviews have indicated that the occurrence of minor infections can be quite common, serious complications are reported to be rare. In addition to commonly anticipated complications including fractures, surgical debridements or revisions, we have identified several significant events in which a patient may require to be readmitted and go through additional surgery. The objective of this study is to examine the rate of occurrence and reports on the best management practices of serious complications across a multi-centre review of more than 1000 osseointegration surgeries. Materials & Methods. A detailed analysis has been performed on all osseointegration surgeries performed by the Osseointegration Group of Australia and it's affiliates between since 2010. The majority of surgeries took place in Australia, the United States, the Middle East as well as in Europe. All events leading to a re-admission and subsequent re-operation have been identified through hospital operation records and pooled together for meta-analysis. Events identified include: revision of implants, periprosthetic fracture fixation, surgical debridement due to infections, neurectomies and soft- tissue refashioning. Results. Over 800 surgeries have been identified with a minimum 12-month follow-up time and included in this study. These included tibial, femoral and humeral, radial-ulnar and transpelvic osseointegration cases. The majority of these were performed using a single stage protocol. While general complications such as infection and soft tissue refashioning are common, serious events such as revision and fracture are rare. Interestingly, the rate of debridements and soft-tissue refashions were found to be higher among patients who were operated using a two-stage surgery. Among all cases, there were a total of 399 re-operation events recorded which occurred among 163 patients, indicating a high recurrence rate among the same patients. We recorded a total of 112 washouts, 93 neurectomies, 117 soft tissue refashions, 53 implant revisions and 24 periprosthetic fracture fixations. Conclusions. Many events leading to readmission after the primary surgery may not necessarily be graded as a complication of the osseointegration technique. This study has identified several addition possible reasons in which an osseointegration patient may need to be re-admitted into hospital for additional surgery. It was identified that through the implementation of improved surgical techniques and rehabilitation protocols, the rate of several of these re-operation events can be largely reduced, thus improving the overall outcomes of patients undergoing osseointegration surgery


Aims. The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit. Methods. A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. A total of 89 consecutive patients (89 knees) were included with 47 females (52.8%) and a median age of 74 years (interquartile range 66 to 79). The main indications were aseptic loosening with instability (39.4%; n = 35) and infection (37.1%; n = 33) with the majority of patients managed through two-stage approach. The mean follow-up was 7.4 years (2 to 16). The overall rate of reoperation, for any cause, was 10.1% (n = 9) with a rate of implant revision of 6.7% (n = 6). Only two cases required surgery for patellofemoral complications. Kaplan-Meier implant-survivorship analysis was 93.3% at ten years, using revision for any cause as an endpoint. Conclusion. This implant achieved high ten-year survivorship with a low complication rate, particularly patellofemoral complications. These can be avoided by ensuring central patella tracking and appropriate tension of the patellofemoral joint in this posterior hinge design. Cite this article: Bone Jt Open 2022;3(3):205–210


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2022
Lu W Oomatia A Muderis MA
Full Access

Introduction. Osseointegration has been established as a promising approach for the reconstruction of amputated limbs, particularly for amputees suffering from traditional socket prosthesis (TSP). While Osseointegration was originally developed with a screw fixation design, several Osseointegration devices adopting a modern press-fit design have also been introduced. In this study, medium-term outcomes for patients with the two most common press-fit osseointegration implant used worldwide are analysed. Materials and Methods. This is a cross-sectional analysis containing a cohort of Osseointegration patients treated in several centres worldwide. We analyzed a total of 93 patients with an average follow-up time of 6.52 years. Functional, Mobility and patient reported outcomes were collected pre-operatively and during follow-up. All postoperative adverse events (infection, revision surgery, fractures, and implant failures) were also analyzed. Results. Crude analysis of the data indicated that all 93 patients continue to use their osseointegrated prosthesis. Significant improvements for all outcome measures were observed. However, several adverse events including 19 implant revisions, 8 periprosthetic fractures and 43 surgical debridements were also reported. A detailed analysis was performed on each adverse event type to evaluate possible causes. Conclusions. At 5 years post-surgery, Osseointegration continues to provide amputees with improvements on function and quality of life which were previously unattainable with socket prosthesis. However, the benefits are accompanied with a relatively high risk of adverse events. Further research in standardizing clinical practice and the development of better implant may offer a reduction to these risks


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 9 - 9
1 Apr 2022
Lu W Oomatia A Muderis MA
Full Access

Introduction. Advantages of osseointegration have been reported to include improved functional mobility, better osseoperception, improved comfort, reduced pain, better biomechanical alignment and gait, which all lead to a less restricted lifestyle and significantly improved quality of life. A major concern of the Osseointegrated approach lies in the risk of infections occurring from the permanent transcutaneous opening often referred to as the stoma. Materials and Methods. Detailed analysis has been performed on all osseointegration surgeries performed by the Osseointegration Group of Australia and it's affiliates since 2010. All events leading to a re-admission and subsequent re-operation have been identified through hospital operation records and pooled together for meta-analysis. Events identified include: revision of implants, periprosthetic fracture fixation, surgical debridement due to infections, neurectomies and soft- tissue refashioning. Results. Majority of these cases were performed following the single-stage protocol. Among all cases, there were a total of 399 re-operation events recorded which occurred among 163 patients, indicating a high recurrence rate among the same patients. We recorded a total of 112 washouts, 93 neurectomies, 117 soft tissue refashions, 53 implant revisions and 24 periprosthetic fracture fixations. Conclusions. In this study, we have identified several addition possible reasons in which an osseointegration patient may need to be re-admitted into hospital for additional surgery. It was identified that through the implementation of improved surgical techniques and rehabilitation protocols, the rate of several of these re-operation events can be largely reduced, thus improving the overall outcomes of patients undergoing osseointegration surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 2 - 2
23 Jun 2023
Hube R Zimmerer A Nonnenmacher L Najfeld M Fischer M Wassilew GI
Full Access

The use of trabecular metal (TM.) shells supported by two TM augments in the footing technique has been described as a potential option for the treatment of Paprosky 3B acetabular defects. The aim of this study was to assess the mid implant survivorship and radiological and clinical outcomes after acetabular revision using this technique. We undertook a retrospective, double-centre series of 39 hips in 39 patients (15 male, 24 female) treated with the footing technique using a TM shell supported by two TM augments, for severe acetabular bone loss between 2007 and 2020. The mean age at the time of surgery was 62,9 (28 to 86) years. The mean follow-up was 5,4 (1,5 to 15) years. The cumulative mid survivorship of the implant with revision for any cause was 89%. 3 hips (7,6%) required further revision due to aseptic loosening, and 1 (2,8%) required revision for infection. The mean Harris Hip Score improved significantly from 48 (29 to 65) preoperatively to 79 points (62 to 98) at the latest follow-up (p < 0.001). The reconstruction of Paprosky 3B acetabular defects with TM shells and two augments in footing-technique showed excellent mid-term results. This technique appears to be a viable option for treating these defects


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 23 - 23
2 Jan 2024
Dragonas C Waseem S Simpson A Leivadiotou D
Full Access

The advent of modular implants aims to minimise morbidity associated with revision of hemiarthroplasty or total shoulder arthroplasty (TSA) to reverse shoulder arthroplasty (RSR) by allowing retention of the humeral stem. This systematic review aimed to summarise outcomes following its use and reasons why modular humeral stems may be revised. A systematic review of Pubmed, Medline and EMBASE was performed according to PRISMA guidelines of all patients undergoing revision of a modular hemiarthroplasty or TSA to RSR. Primary implants, glenoid revisions, surgical technique and opinion based reports were excluded. Collected data included demographics, outcomes and incidence of complications. 277 patients were included, with a mean age of 69.8 years (44-91) and 119 being female. Revisions were performed an average of 30 months (6-147) after the index procedure, with the most common reason for revision being cuff failure in 57 patients. 165 patients underwent modular conversion and 112 underwent stem revision. Of those that underwent humeral stem revision, 18 had the stem too proximal, in 15 the stem was loose, 10 was due to infection and 1 stem had significant retroversion. After a mean follow up of 37.6 months (12-91), the Constant score improved from a mean of 21.8 to 48.7. Stem revision was associated with a higher complication rate (OR 3.13, 95% CI 1.82-5.39). The increased use of modular stems has reduced stem revision, however 40% of these implants still require revision due to intra-operative findings. Further large volume comparative studies between revised and maintained humeral stems post revision of modular implants can adequately inform implant innovation to further improve the stem revision rate


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 52 - 52
23 Feb 2023
Full Access

THA in patients with acetabular bone defects is associated with a high risk of dislocation. Dual mobility (DM) cups are known to prevent and treat chronic instability. The aim of this study was to evaluate the dislocation rate and survival of jumbo DM cups. This was a retrospective, continuous, multicenter study of all the cases of jumbo DM cup implantation between 2010 and 2017 in patients with acetabular bone loss (Paprosky 2A: 46%, 2B: 32%, 2C: 15% and 3A: 6%). The indications for implantation were revisions for aseptic loosening of the cup (n=45), aseptic loosening of the femoral stem (n=3), bipolar loosening (n=11), septic loosening (n=10), periprosthetic fracture (n=5), chronic dislocation (n=4), intraprosthetic dislocation (n=2), cup impingement (n=1), primary posttraumatic arthroplasty (n=8), and acetabular dysplasia (n=4). The jumbo cups used were COPTOS TH (SERF), which combines press-fit fixation with supplemental fixation (acetabular hook, two superior flanges with one to four screws, two acetabular pegs). A bone graft was added in 74 cases (80%). The clinical assessment consisted of the Harris hip score. The primary endpoint was surgical revision for aseptic acetabular loosening or the occurrence of a dislocation episode. In all, 93 patients were reviewed at a mean follow-up of 5.3 ± 2.3 years [0, 10]. As of the last follow-up, the acetabular cup had been changed in five cases: three due to aseptic loosening (3.2%) and two due to infection (2.1%). The survivorship free of aseptic loosening was 96.8%. Three patients (3%) suffered a dislocation. At the last follow-up visit, the mean HSS scores were 72.15, (p < 0.05). Use of a jumbo DM cup in cases of acetabular bone defects leads to satisfactory medium-term results with low dislocation and loosening rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 20 - 20
17 Nov 2023
van Duren B France J Berber R Matar H James P Bloch B
Full Access

Abstract. Objective. Up to 20% of patients can remain dissatisfied following TKR. A proportion of TKRs will need early revision with aseptic loosening the most common. The ATTUNE TKR was introduced in 2011 as successor to its predicate design The PFC Sigma (DePuy Synthes, Warsaw, In). However, following reports of early failures of the tibial component there have been ongoing concerns of increased loosening rates with the ATTUNE TKR. In 2017 a redesigned tibial baseplate (S+) was introduced, which included cement pockets and an increased surface roughness to improve cement bonding. Given the concerns of early tibial loosening with the ATTUNE knee system, this study aimed to compare revision rates and those specific to aseptic loosening of the ATTUNE implant in comparison to an established predicate as well as other implant designs used in a high-volume arthroplasty centre. Methods. The Attune TKR was introduced to our unit in December 2011. Prior to this we routinely used a predicate design with an excellent long-term track record (PFC Sigma) which remains in use. In addition, other designs were available and used as per surgeon preference. Using a prospectively maintained database, we identified 10,202 patients who underwent primary cemented TKR at our institution between 01/04/2003–31/03/2022 with a minimum of 1 year follow-up (Mean 8.4years, range 1–20years): 1) 2406 with ATTUNE TKR (of which 557 were S+) 2) 4652 with PFC TKR 3) 3154 with other cemented designs. All implants were cemented using high viscosity cement. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Matched cohorts were selected from the ATTUNE subsets (original and S+) and PFC groups using the nearest neighbor method for radiographic analysis. Radiographs were assessed to compare the presence of radiolucent lines in the Attune S+, standard Attune, and PFC implants. Results. At a mean of 8.4 years follow-up, 308 implants underwent revision equating to 3.58 revisions per 1000 implant-years. The lowest risk of revision was noted in the ATTUNE cohort with 2.98 per 1000-implant-years where the PFC and All Other Implant groups were 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision across all cemented implants with 76% (65/88) of involving loosening of the tibia. Survival analysis comparing the ATTUNE cohort to the PFC and All Other Cemented Implant cohorts showed no significant differences for: all-cause revision, aseptic loosening, or tibial loosening (p=0.15,0.77,0.47). Radiolucent lines were detected in 4.6%, 5.8%, and 5.0% of the ATTUNE S+, standard ATTUNE, and PFC groups respectively. These differences were not significant. Conclusion. This study represents the largest non-registry review of the original and S+ ATTUNE TKR in comparison to its predicate design as well as other cemented implants. There appears to be no significant increased revision rate for all-cause revision or aseptic loosening. Radiographic analysis also showed no significant difference in peri-implant radiolucency. It appears that concerns of early loosening may be unfounded. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 29 - 29
1 Jul 2022
Bishi H Afzal I Wang C Stammers J Mitchell P Field R Alazzawi S
Full Access

Abstract. Introduction. In revision knee arthroplasty, rotating hinge implants (RHK) have been considered to result in higher complication rates and lower survivorship when compared to constrained condylar implants (CCK). The aims of this study were to compare patient reported outcome measures (PROMs), complication rates and survivorship of RHK and CCK used in revision arthroplasty at a single, high volume elective orthopaedic centre with previously validated bespoke database. Methodology. One hundred and eight patients who underwent revision knee arthroplasty with either CCK or RHK and matched our inclusion criteria were identified. EQ5D, Health State and Oxford Knee Scores were collected pre-operatively and at 1 year post-operatively. Complication data was collected at 6 weeks, 6 months, 1 year and 2 years post-operatively. NJR data was interrogated, in addition to our own database, to investigate implant survival. Results. There was no statistically significant difference between RHK and CCK in implant survival at two to twelve years of follow up. In addition, we observed no statistically significant difference in the PROMs scores and complication rates of the two implants. Conclusion. This study shows that both the RHK and CCK remain viable options in revision arthroplasty, the implant survival and complication rate were comparable. We recommend prospective randomised control trials with long-term follow up to further investigate the use of CCK and RHK implants in revision knee arthroplasty


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 82 - 82
1 Oct 2022
Scheper H Mahdad R Elzer B Löwik C Zijlstra W Gosens T van der Lugt J van der Wal R Poolman R Somford M Jutte P Bos K Kooijman C Maree H Nelissen R Visser LG De Boer MG
Full Access

Background. The duration and extent of postoperative wound leakage after joint arthroplasty in patients with or without a complicated course, like a prosthetic joint infection (PJI), is currently unknown. Adequate differentiation between normal postoperative wound leakage and wound leakage due to a postoperative PJI is important and prevents unnecessary surgical procedures. We investigated the association between postoperative wound leakage and development of PJI in patients who used a previously developed mobile wound care app. Methods. A multicenter, prospective cohort study with patients aged 18 years or older after primary implantation or revision of a total joint arthroplasty. During 30 post-operative days after arthroplasty, patients recorded their wound status in the woundcare app. An algorithm calculated a daily score from imputed data. If the daily score exceeded a predefined threshold, the patients received an alert that advised them to contact their physician. Results. Of 1020 included patients from 11 centers, 14 patients developed a PJI. Of 1006 patients without PJI, any form of postoperative wound leakage occurred in 51%, 12%, 7% and 3% during the 1. st. , 2. nd. , 3. rd. and 4. th. postoperative week, respectively. Median duration of wound leakage was eight days (IQR 3.5–12.5) for patients with PJI and two days (IQR 0–4) for patients without PJI (p <0.001). In total, 498 (49%) patients received 2589 alerts. Receiving an alert was not predictive for the development of a PJI. The odds ratio for a PJI was higher in patients with wound leakage compared to patients without wound leakage: OR 1.76 (0.59–5.29), OR 45.42 (10.04–205.53), OR 16.76 (3.68–76.28) and OR 18.09 (1.59–205.66) in the 1. st. , 2. nd. , 3. rd. and 4. th. postoperative week, respectively. Conclusion. In patients who received a knee or hip arthroplasty, the odds ratios for PJI were significantly increased in patients with postoperative wound leakage. However, the high absolute number of patients with wound leakage and no PJI showed that wound leakage alone is not a sensitive, i.e. discriminative, indicator to guide the decision whether to reoperate patients for a suspected PJI. The abstract was submitted on behalf of the Woundcare app study group: H.M.J. van der Linden, Leiden University Medical Centre; D. Broekhuis, Leiden University Medical Centre; M. de Jong, Leiden University Medical Centre; M.R. Benard, Alrijne Hospital; A.P. Wassenaar, Alrijne hospital; A.S.B. Mol, Alrijne Hospital; M. Rutgers, Reinier Haga Orthopedic Center; J.Pasma, Reinier Haga Orthopedic Center; R. Bazuin, Reinier Haga Orthopedic Center; N. Mathijssen, Reinier Haga Orthopedic Center; C.E. Van Der Wijngaart, Onze Lieve Vrouwe Gasthuis; N.W. Willigenburg, Onze Lieve Vrouwe Gasthuis; M.E. Van Der Hoorn, Onze Lieve Vrouwe Gasthuis; B. Dijkstra, Medical Center Leeuwarden; L.D. De Jong, Rijnstate Hospital; H. Haan, University Medical Centre Groningen; M. Stevens, University Medical Centre Groningen; M. Reijman, Erasmus Medical Centre Rotterdam; H. Hoogeboom, Nijsmellinghe Medical Centre; C. Meijer, Park Medical Centre + all authors listed above this article


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims. The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. Methods. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. Results. Five shoulders underwent revision surgery (3.5%); three for rotator cuff failure, one for infection, and one for component malposition. Survivorship of the implant was 95.4% (95% confidence interval 90.1% to 97.9%) at five and nine years. Mean OSS improved significantly compared to preoperative values from 19.0 (1 to 35) to 43.3 (7 to 48) (p < 0.001). Radiological analysis was undertaken for 99 shoulders. This revealed humeral RLLs in one case (1%), glenoid RLLs in 15 cases (15.2%), and radiological rotator cuff failure in 22 cases (22.2%). Conclusion. This prospective cohort study shows encouraging short- to mid-term survivorship and clinical and radiological results for the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis. Level of Evidence: IV. Cite this article: Bone Jt Open 2021;2(1):58–65


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 127 - 127
1 Nov 2021
Batailler C Lording T Naaim A Servien E Cheze L Lustig S
Full Access

Introduction and Objective. In recent studies, robotic-assisted surgical techniques for unicompartmental knee arthroplasty (UKA) have demonstrated superior implant positioning and limb alignment compared to a conventional technique. However, the impact of the robotic-assisted technique on clinical and functional outcomes is less clear. The aim of this study was to compare the gait parameters of UKA performed with conventional and image-free robotic-assisted techniques. Materials and Methods. This prospective, single center study included 66 medial UKA, randomized to a robotic-assisted (n=33) or conventional technique (n=33). Gait analysis was performed on a treadmill at 6 months to identify changes in gait characteristics (walking speed, each degree-of-freedom: flexion–extension, abduction–adduction, internal-external rotation and anterior-posterior displacement). Clinical results were assessed at 6 months using the IKS score and the Forgotten Joint Score. Implants position was assessed on post-operative radiographs. Results. Post-operatively, the whole gait cycle was not significantly different between groups. In both groups there was a significant improvement in varus deformity between the pre- and post-operative gait cycle. There was no significant difference between the two groups in clinical scores, implant position, revision and complication rates. Conclusions. No difference of gait parameters could be identified between medial UKA performed with image-free robotic-assisted technique or with conventional technique


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 34 - 34
1 Aug 2021
Ramavath A Leong J Siney P Kay P Divecha H Board T
Full Access

Principles of bone preservation and restoration of biomechanical alignment should be followed during revision total hip arthroplasty (THA). Where possible, conservative femoral revision techniques and even reconstructive de-escalation involving using primary stems should be considered. This study aims to investigate the outcome of patients who have undergone conservative femoral revision THA in our Institution. We retrospectively identified patients from our Institution's revision arthroplasty database who had cemented, or un-cemented primary stems implanted during revision THA of a previous stemmed femoral implant. Our primary outcome measure was all-cause re-revision THA with a secondary outcome measure of improvement in Oxford hip score (OHS). Radiographic evidence of stem loosening and post-op complications were recorded. Between 02/12/2014 to 12/12/2019, there were 226 patients identified with a mean follow up of 2 years (1–5 years). The majority of cases were represented by Paprosky type 1 (63%) and type 2 (25%) femoral defects. There were 45 patients (20%) who underwent impaction bone grafting (IBG) and 43 patients (19%) who had a cement in cement (CinC) femoral revision and cemented primary stem in 137 (60%), 1 uncemented stem with no IBG or CinC revision. Kaplan Meier survival for all-cause re-revision THA was 93.7% (95% CI: 88.3 – 100) at 3 years. The reasons for re-revision included 4 periprosthetic fractures, 4 dislocations, 1 deep infection, 1 loosening of femoral component and 1 loosening of acetabular component. Pre- and post-operative OHS scores were available in 137 hips (60%) with a mean improvement of 13. Radiographic review revealed 7% of cases with evidence of loosening in 1 or more Gruen zones. Our early results support the use of conservative femoral revision THA techniques where appropriate, with low complication and re-revision rates. Revisions using primary femoral components, where appropriate, should be considered in surgical planning to avoid unnecessary reconstructive escalation


Full Access

Arthroplasty has consistently shown ‘beneficial and often dramatic improvements in quality of life'. In developed healthcare systems arthroplasty has evolved to minimised complications through evidence-based implant selection, rigorous infection control and high volume training. The Children's Surgical Centre has performed 256 THAs since 2007, We aim to assess the outcome of arthroplasty in a LMIC. Our primary outcome was all cause of re-operation and our secondary outcome was any complications not requiring return to theatre. A retrospective review of all consecutive THA since 2007 was conducted. Electronic and physical case notes were reviewed and basic demographics, indication for THA, risk factors for complications, implant combinations and complications were recorded. Statistical analysis was performed using MedCalc. A total of 256 THA were identified in 225 patients. The mean age was 43, with a M2:1F ratio. The most common pathologies were (1)AVN (44%), (2)OA (11%) and (3)DDH (11%). Revision rate was 13%. The mean time from implantation to revision was 2.8 years (0–9). The most common reasons for revision were (1)stem fracture (5.8%), (2)aseptic loosening (4.8%) and (3)infection (2.7%). Six different stems have been use over the time period. The best surviving were the Zimmer ML Taper and the UMA Muller stems. The UMA C-Stem was the worst performing which suffered 100% stem fracture. 109 complications were identified in 85 patients (33.2%). The three most common complications were (1)aseptic loosening (10.5%) (2)stem fracture (5.8%) and (3)dislocation (5.8%). Previous surgery (n=44) was found to be a significant risk for complications but not infection. OHS initially improved but began to decline after year 3. Patients present to CSC with neglected hip pathology, disability and significant pre-operative deformity. These patients benefit from THA and the initially high complication rates at CSC are declining suggesting the apex of the ‘learning curve' has passed. Cheap poorly manufactured implants continue to cause catastrophic failure


Bone & Joint Open
Vol. 5, Issue 8 | Pages 688 - 696
22 Aug 2024
Hanusrichter Y Gebert C Steinbeck M Dudda M Hardes J Frieler S Jeys LM Wessling M

Aims

Custom-made partial pelvis replacements (PPRs) are increasingly used in the reconstruction of large acetabular defects and have mainly been designed using a triflange approach, requiring extensive soft-tissue dissection. The monoflange design, where primary intramedullary fixation within the ilium combined with a monoflange for rotational stability, was anticipated to overcome this obstacle. The aim of this study was to evaluate the design with regard to functional outcome, complications, and acetabular reconstruction.

Methods

Between 2014 and 2023, 79 patients with a mean follow-up of 33 months (SD 22; 9 to 103) were included. Functional outcome was measured using the Harris Hip Score and EuroQol five-dimension questionnaire (EQ-5D). PPR revisions were defined as an endpoint, and subgroups were analyzed to determine risk factors.


Bone & Joint Research
Vol. 13, Issue 10 | Pages 535 - 545
2 Oct 2024
Zou C Guo W Mu W Wahafu T Li Y Hua L Xu B Cao L

Aims

We aimed to determine the concentrations of synovial vancomycin and meropenem in patients treated by single-stage revision combined with intra-articular infusion following periprosthetic joint infection (PJI), thereby validating this drug delivery approach.

Methods

We included 14 patients with PJI as noted in their medical records between November 2021 and August 2022, comprising eight hip and seven knee joint infections, with one patient experiencing bilateral knee infections. The patients underwent single-stage revision surgery, followed by intra-articular infusion of vancomycin and meropenem (50,000 µg/ml). Synovial fluid samples were collected to assess antibiotic concentrations using high-performance liquid chromatography.