Abstract. Introduction. Compared to the standard Tomofix plate, the anatomical Tomofix medial
Abstract. Introduction. Surgery in patients with high body mass index (BMI) is more technically challenging and associated with increased complications post-operatively. Inferior clinical and functional mid-term results for high BMI patients undergoing
The Olympia femoral stem is a stainless steel, anatomically shaped, polished and three-dimensionally tapered implant designed for use in cemented total hip arthroplasty (THA). The primary aim of this study was to determine the long-term survivorship, radiographic outcome, and patient reported outcome measures (PROMs) of the Olympia stem. Between May 2003 and December 2005, 239 patients (264 THAs) underwent a THA with an Olympia stem in our institution. PROMs were assessed using the Oxford Hip Score (OHS), EuroQol-5 dimensions (EQ-5D) score and patient satisfaction at mean 10-years following THA. Patient records and radiographs were then reviewed at a mean of 16.5 years (SD 0.7, 15.3 to 17.8) following THA to identify occurrence of complications or revision surgery for any cause. Mean patient age at surgery was 68.0 years (SD 10.9, 31–93 years). There were 156 women (65%, 176 THAs). Osteoarthritis was the indication for THA in 204 patients (85%). Stem survivorship at 10 years was 99.2% (95 % confidence interval [CI], 97.9%-100%) and at 15 years was 97.5% (94.6%–100%). The 15-year stem survival for aseptic loosening was 100%. Only one occurrence of peri-prosthetic fracture was identified, with no episodes of dislocation found. At a mean of 10 (SD 0.8, 8.7 –11.3) years follow-up, mean OHS was 39 (SD 10.3, range 7 – 48) and 94% of patients reported being very satisfied or satisfied. The Olympia stem demonstrated excellent 10-year PROMs, very
The aim of this study was to determine the long term 20 year survival and outcomes of
Aims. Orthopaedic surgery uses many varied instruments with high-speed, high-impact, thermal energy and sometimes heavy instruments, all of which potentially result in aerosolization of contaminated blood, tissue, and bone, raising concerns for clinicians’ health. This study quantifies the aerosol exposure by measuring the number and size distribution of the particles reaching the lead surgeon during key orthopaedic operations. Methods. The aerosol yield from 17 orthopaedic open surgeries (on the knee, hip, and shoulder) was recorded at the position of the lead surgeon using an Aerodynamic Particle Sizer (APS; 0.5 to 20 μm diameter particles) sampling at 1 s time resolution. Through timestamping, detected aerosol was attributed to specific procedures. Results. Diathermy (electrocautery) and oscillating bone saw use had a
Increasing femoral offset in total hip replacement (THR) has several benefits including improved hip abductor strength and enhanced range of motion. Biomechanical studies have suggested that this may negatively impact on stem stability. However, it is unclear whether this has a clinical impact. Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), the aim of this study was to determine the impact of stem offset and stem size for the three most common cementless THR prostheses revised for aseptic loosening. The study period was September 1999 to December 2020. The study population included all primary procedures for osteoarthritis with a cementless THR using the Corail, Quadra-H and Polarstem. Procedures were divided into small and large stem sizes and by standard and
Abstract.
Stem cells are known to have low levels of intracellular reactive oxygen species (ROS) and
More and more evidences showed that cartilage harbored local progenitor cells that could differentiate toward osteoblast, chondrocyte, and adipocyte. However, our previous results showed that osteoarthritis derived chondroprogenitor cells (OA-CPC) exhibited strong osteogenic potential even in chondrogenic condition. How to promote their chondrogenic potential is the key for cartilage repair and regeneration in osteoarthritis. Recently, lipid availability was proved to determine skeletal progenitor fate. Therefore, we aim to determine whether lipid inhibition under 3D culture condition could enhance OA-CPC chondrogenesis. Moreover, glucose concentration was also evaluated for chondrogenic capacity. Although there are many researches showed that lower glucose promotes chondrogenesis, in our results, we found that OA-CPC in
Background. Surgical intervention for hallux valgus and hallux rigidus is an option for patients presenting with severe pain and deformity. Literature suggest that patients with
This study aimed to examine the effect of
Introduction. Early clinical examination combined with MRI following a
Aims. Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. Methods. A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option). Results. Between 2013 and 2016, 352 NexGen TKAs were carried out on 331 patients. A total of 62 TKAs have been revised to date, giving an all-cause revision rate of 17.6% at a minimum of five years. Three of these revisions were due to infection. Overall, 59 of the revisions were performed for aseptic loosening (16.7%) of the tibial component. The tibial component was removed intraoperatively without instrumentation due to significant tibial debonding between the implant-cement interface. Conclusion. While overall, we believe that early aseptic loosening is multi-factorial in nature, the significantly
Aims. The role of N,N-dimethylformamide (DMF) in diabetes-induced osteoporosis (DM-OS) progression remains unclear. Here, we aimed to explore the effect of DMF on DM-OS development. Methods. Diabetic models of mice, RAW 264.7 cells, and bone marrow macrophages (BMMs) were established by streptozotocin stimulation,
Unicompartmental knee arthroplasty (UKA) and
Medial opening wedge
Aim. One of the surgical therapeutic options for periprosthetic joint infection (PJI) includes debridement, antibiotics, and implant retention (DAIR). Prognostically favorable criteria for DAIR include short duration of symptoms, stable implant, pathogen susceptible to a ‘biofilm-active’ antimicrobial agent, and intact soft-tissue conditions. Despite this, there is a proportion of failures after DAIR, possibly because the duration of infection is underestimated. With the hypothesis that the duration of infection correlates with the bacterial load, and hence, the bacterial load is associated with failure after DAIR, we aimed to investigate the association of bacterial load in the sonication fluid of mobile parts and clinical outcome after DAIR. Method. From our PJI cohort (2010–2021), patients with DAIR (both palliative and curative approaches) were reviewed retrospectively. Patients with hip, knee or shoulder arthroplasties fulfilling infection definition, available sonication results, and ≥2 years follow-up were included. Sonication results were categorized in ≤ or >1000 cfu/mL. Univariate analysis was performed to identify predictors for DAIR failure. Results. Out of 209 PJIs, we identified 96 patients (100 PJIs, 47.8%) with DAIR. In 67 (69.8%) patients with 71 PJIs, there was a follow-up of ≥2 years. The mean age was 72.7 (SD 12.99) years, 50% were male. The infection affected 36 hips (50.7%), 32 knees (45.1%) and 3 shoulders (4.2%). At follow-up, there were 29 (40.8%) cured and 42 (59.2%) failed cases. When comparing failed and cured cases, we found no difference in comorbidities and previously defined risk factors for PJI, ASA score, Charlson score, anatomic location, no. of previous surgeries, pathogenesis of infection or laboratory values. The proportion of patients with
This study aimed to characterise the microarchitecture of bone in different species of animal leading to the development of a physiologically relevant 3D printed cellular model of trabecular (Tb) and cortical bone (CB). Using
It is still difficult to determine an appropriate hinge position to prevent fracture in the lateral cortex of tibia in the process of making an open wedge during biplane open wedge
Introduction. The management of young patients with painful medial compartment osteoarthritis remains controversial. Opening wedge medial high-tibial osteotomy using a locking plate has shown good results in selected patients. This cohort of patients has