Abstract. Objective. Short-stem total hip arthroplasty (THA) aims to preserve the proximal bone stock for future revisions, so that the first revision should resemble a primary intervention rather than a revision. This study aimed to compare the clinical and radiological outcomes in revision THA after failed short stem versus after failed
OBJECTIVE OF THE STUDY. The objective of this study is to establish the medium-term clinical and radiological results with the cementless three-dimensional Vektor-Titan stem compared with
Introduction: Disagreement exists in the literature as to whether hip resurfacing requires more acetabular reaming than uncemented hip replacement. Materials and Methods: Thirty-nine patients underwent total hip arthroplasty with a large metal on metal resurfacing acetabular cup and large metal head with a conventional uncemented femoral stem. Although there was no change in routine operative technique the femoral neck was measured (as if for resurfacing) before being cut. The size of the acetabular component actually inserted was compared with the smallest size which could have been used had a resurfacing been carried out for each patient. A two tailed paired t test was carried out. Results: We found that there was no difference in female patients but in men the actual cup used was 2.44mm smaller than the smallest possible resurfacing cup which equates to 6.39cm. 3. less bone (p <
0.0001). Discussion: By using paired samples we have reduced confounding factors and shown that a large metal on metal bearing on a
Adverse Local Tissue Reactions (ALTR) have been reported in association with both wear and corrosion. Tissue reactions have been reported in association with corrosion at CoCr head-CoCr neck, CoCr head-TiAl6V4 neck, and CoCr modular neck on beta-titanium (TMZF) stem junctions. The current abstract reports on 3 cases of ALTR in association with CoCr modular necks on convention titanium (TiAl6V4) stem junctions. Case 1. A 67 year old male (87 kg, 1.73 m, BMI 29.1) presented with new onset hip irritation 11 months after surgery. Radiographs show no abnormalities. Further investigation revealed the following: ESR = 95, CRP = 5, Cr level = 1.0, Co level = 4.1, leukocyte transformation testing = highly reactive to nickel. Hip aspiration was culture negative with 11,250 wbc. Metal artifact reduction MR showed cystic local reaction in the region of the greater trochanter. Case 2. A 52 year old male (89 kg, 1.83 m, BMI 26.5) presented with new onset hip irritation 30 months after surgery. Radiographs show no abnormalities. Further investigation revealed the following: ESR = 7, CRP = 5.4, Cr level = 2.1, Co level = 4.8, leukocyte transformation testing = reactive to nickel. Hip aspiration was culture negative with 3995 wbc. Metal artifact reduction MR showed cystic local reaction in the region of the iliopsoas. Case 3. A 52 year old male (104 kg, 1.85 m, BMI 30.1) presented with new onset hip irritation 26 months after surgery. Radiographs show no abnormalities. Further investigation revealed the following: ESR = 33, CRP = 34.9, Cr level = 1.0, Co level = 3.7, leukocyte transformation testing = no reactivity to any of the biomaterials. Hip aspiration was culture negative with 3,780 wbc. Metal artifact reduction MR showed cystic local reaction in the region of the iliopsoas. All three of these patients are scheduled for revision surgery. All three had ceramic-ceramic bearings. We have experience with 1029 ceramic-ceramic THA with fixed neck conventional titanium and modular titanium neck implants with minimum 2 yr f/u and have never diagnosed an adverse reaction in any of these patients. It is possible that corrosion at the CoCr neck on TiAl6V4 stem junction is the root cause of these reactions. Although the incidence of diagnosed reactions is roughly 1%, it appears that the use of CoCr at any junction under significant mechanical stress can result in adverse local tissue reaction and therefore should either be avoided or used with great caution and compelling indications.Introduction
Discussion
Post-operative peri-prosthetic femoral fracture (PO-PPFF) is one of the most relevant complications in primary Total Hip Arthroplasty (pTHA), accountable for a significant clinical and socio-economic burden both in revision and fixation settings. We retrospectively reviewed of our series of 1586 cementless total hip arthroplasty performed between 1999 and 2019 (achieving a minimum of 5-years follow-up) with different short stems. We have observed a cumulative low incidence of PO-PPFF of 0,33% (5 cases): we divided Po-PPFF in two groups: fracture occurred around a short stem (A) and around a standard shortened stem (B), according to French Hip & Knee Classification of Short Stems. Despite the length of observed period (mean follow-up 12 years, min 5 years max 24 years) a total of 1512 cases (mean age at surgery 61 years, max 74, min 40 years) were available to clinical and radiographic follow-up, being this population enrolled in elective surgery clinical protocols. Our data exceed the low incidence of post-operative femoral fracture around bone -preserving previously reported by Kim in 2018 (12 fracture out of 1089 cases:1.1%). No correlation have been observed among occurrence of PO-PPF age of the patient and no fracture occurred around cemented short stems despite patient's characteristics were unfavourable in term of age and bone quality. This result is not unexpected, giving the lower incidence of peri-prosthetic fracture even cemented
Short stems have been developed to conserve bone stock, especially in younger populations undergoing a total hip arthroplasty (THA), and showed similar functional outcomes compared to
Background. Short bone-conserving femoral stem implants were developed to achieve more physiological, proximal bone loading than
Introduction: Aim of the study was to investigate the fixation patterns of cementless short-stem designs compared to the fixation patterns of well-known
Background. Total Hip Arthroplasty (THA) has long been the standard treatment for cases in which non-surgical alternatives have failed to improve pain and function in hip osteoarthritis (OA) patients. Outcomes from THA have improved over time with better surgical techniques and improved implant designs. While conventional neck-sacrificing implants have been associated with favorable outcomes, there is evidence to suggest biomechanical advantages of newer, femoral neck-preserving short-stem implants, including the Corin MiniHip. However, there is a still a gap of knowledge regarding the potential benefits of the MiniHip
Introduction:. Significant proximal femoral remodeling occurs after total hip arthroplasty (THA), with regions of bone loss, and regions of hypertrophy. This study compared three implants for changes in femoral bone mineral density over 2 years following primary uncemented hip arthroplasty with a
The Exeter. ™. V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and
Aims. The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and
INTRODUCTION. Short femoral stem use in total hip arthroplasty (THA) has increased due to positive short-term clinical and biomechanical success. A neck preserving femoral stem not only preserves proximal bone volume, but preserves the high quality bone of the medial neck. The short stem design allows for less invasive surgical exposure and less invasive violation of the femoral canal (Figure 1). Additionally, it facilitates future revision THA, if needed, with a
Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane. Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.Aims
Methods
Introduction:. In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the load to fracture of a new polished tapered cemented short stem in comparison to the conventional polished tapered Exeter stem. Method:. A total of forty-two stems, twenty-one short stems and twenty-one
There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning. In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition.Aims
Methods
Hip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an anatomical and medialized hip rotation centre. Using 3D templating software in 49 CT scans of non-deformed femora, we virtually implanted: 1) small uncemented calcar-guided stems with two offset options (Optimys, Mathys), 2) uncemented straight stems with two offset options (Summit, DePuy Synthes), 3) cemented undersized stems (Exeter philosophy) with three offset options (CPT, ZimmerBiomet), and 4) cemented line-to-line stems (Kerboul philosophy) with proportional offsets (Centris, Mathys). We measured the distance between the templated and the anatomical and 5 mm medialized hip rotation centre.Aims
Methods
Introduction. Femoral neck fracture is a common injury in elderly patients. To restore the activity with an acceptable morbidity and to decrease of mortality, surgical procedures are thought to be superior to conservative treatments. Osteosynthesis with internal fixation for nondisplaced type, and hemiarthroplasty or total hip replacement (hip arthroplasties) for displaced type are commonly performed. Cemented arthroplasty has been preferred over non-cemented arthroplasty because of less postoperative pain, better mobility and excellent initial fixation of the implant, especially for osteoporotic and stove-pipe bones. However, pressurizing bone cement may cause cardiorespiratory and vascular complications, and occasionally death, which has been termed as “bone cement implantation syndrome”. To avoid the occurrence of this syndrome, non-cemented implants have been developed. However, most implants with the press fit concepts and flat wedge taper designs have a risk of intraoperative and early postoperative periprosthetic fracture. Recently, we have employed a non-cemented femoral component, which has a lateral expansion to the proximal body as compared to a
Total hip arthroplasty is well established as a successful treatment modality for end stage arthritis, with a variety of components currently available. However, utilising traditional stemmed implants in patients with distorted proximal femoral geometry can be technically challenging with increased risk of complications. We present seven patients with distorted proximal femoral anatomy or failed hip arthroplasty in whom a technically challenging primary or revision operation was simplified by use of a Proxima stem. This is a short, stemless, metaphyseal loading implant with a pronounced lateral flare. At twelve months follow up there have been no complications with average improvement in Oxford and Harris scores of forty and forty-nine respectively. Radiological analysis shows all stems to be stable and well fixed. Designed primarily as a bone conserving implant for primary hip arthroplasty we propose that the Proxima prosthesis also be considered in cases where a
Over the past 10 years, the orthopedic community has witnessed an increased interest in more conservative surgical techniques for hip arthroplasty. During this time, second-generation hip resurfacing and minimally invasive surgery enjoyed extensive marketing attention. After a decade of this renewed interest, both of these methods have met with serious concerns. As hip resurfacing numbers decline, both patients and surgeons are looking for other potentially successful conservative treatments to THA. This search has focused surgeon interest toward short-stem designs. Today, a variety of short-stem implants are available with very little clarification of design rationale, fixation features, surgical technique, and clinical outcomes. Virtually every major implant company now offers a “short stem,” and now there are a plethora of different designs. It is important to note, however, that not all short stems achieve initial fixation at the same bone interface region. Furthermore, surgical techniques vary greatly, and postoperative radiographic interpretation of short-stem position and fixation need to be carefully scrutinized. The purpose of this paper is to review past, present, and potential future developments of short femoral stems and to present a classification system that can offer guidance when reporting on the many different stem variations. Short Curved neck-sparing stem (JISRF classification 2a). Recently, new designs are following Pipino's Biodynamic stem style of saving the femoral neck. These designs feature a short curved stem that finds its stabilization contact region in the femoral neck and saves considerable bone in the medial calcar region. In addition, the curvature of the stem prevents violation of the lateral trochanteric region. The shorter stem also reduces blood loss by not reaming the femoral canal distally. These style stems generally have a variable stem length between 90 and 135 mm. This might not appear much shorter than