Abstract. Introduction.
Introduction. Patients with FNF may be treated by either total hip arthroplasty (THA) or hemiarthroplasty (HA). Utilizing American Joint Replacement Registry (AJRR) data, we aimed to evaluate outcomes in FNF treatment. Methods. Medicare patients with FNF treated with HA or THA reported to the AJRR database from 2012–2019 and CMS claims data from 2012–2017 were analyzed in this retrospective cohort study. “Early” was defined as less than 90 days from index procedure. A logistic regression model, including index arthroplasty, age, sex, stem fixation method, hospital size. 1. , hospital teaching affiliation. 1. , and Charlson comorbidity index (CCI), was utilized to determine associations between index procedure and revision rates. Results. Of 75,333 FNF procedures analyzed, 82.2% had HA. 8.4% had cemented fixation. 36.9% had
Cementless femoral fixation in total knee replacement has proven to be successful in many studies. There is a recent report by Berger et al, on failure of
The aim of this study is to present the early results of our department’s experience, about
In properly chosen patients, cementless total knee arthroplasty has achieved success rates equal to cemented designs. The initial variable results of early cementless total knee replacements were a function of design, surgical technique and patient selection. Important design considerations that have enhanced biologic ingrowth include the use of commercially pure titanium with optimal pore size and porosity, and avoidance of porous-coated stems and plugs that cause stress shielding of the bone-implant interface. Factors in surgical technique that enhance bone ingrowth include precise bone cuts that maximize bone-implant contact, and the application of autogenous bone slurry to cut surfaces. Additional factors are restoration of normal alignment, appropriate ligament balance, and the reproduction of the patient's native tibial slope in order to prevent tibial component subsidence. Young and active patients are ideal biological hosts for the use of
Antibiotic-impregnated cement is frequently used for fixation of total knee prostheses as a measure to prevent postoperative infection. In recent years, more cementless knee prostheses have been implanted especially for younger patients. In 1997 to June 2004, 35044 primary total knee arthroplasties for primary or secondary osteoarthritis were performed in Finland and registered in nationwide arthroplasty register. The patients aged 70 years (range 21–96) on average, and 71.7% were women. During the median follow-up of 39 months (range 0–104), 978 (2.8%) knees were revised. There were 188 (0.58%), 21 (1.09%) and 10 (1.18%) reoperations due to infection after cemented, hybrid and cementless arthroplasties, respectively (p=0.003). In hybrid arthroplasties with cemented tibial component, the septic reoperation rate did not significantly differ from cemented arthroplasties. Instead, the higher number of infections after hybrid arthroplasty was related to use of cementless tibial components (5.3% vs. 0.9%, p<
0.008). In Cox regression model adjusted for age, gender and diagnosis, the hazard ratio for septic reoperation after knee replacement with cementless tibial component was 2.4 (95% CI 1.4–4.1) compared to the cemented alternative. The fixation method did not affect the rate of septic reoperations occurring after the first postoperative year.
Purpose of Study. To assess the incidence of radiolucency in cemented and cementless Oxford unicompartmental knee replacement at two years. Introduction. Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring
Introduction: The information in the literature about the relative merits of cemented and cementless unicompartmental knee replacement (UKR) is contradictory, with some favouring
Introduction: Intramedullary
Introduction. Few studies are published about total hip arthroplasties (THA) in Parkinson's disease as it is often considered as a contraindication for hip replacement. THA for fracture is reported as a high complication rate surgery. Regarding bone quality these cases are assimilated to elderly patients and cemented implants are generally preferred. However, due to the improved length and quality of life, we face more potential indications for joint replacement. The aim of this study is to report our experience of cementless dual mobility implants for primary THAs for osteoarthrosis and THA revisions focusing on the risks and benefits of surgery. Material and methods. 65 THA were performed in 59 patients (34 men, 25 women, mean age 73 years, 55–79). Mean latest follow-up was 8,3 years (4–14). Indications were 42 primary THA (osteoarthrosis) and 21 revisions (11 recurrent dislocation, 6 acetabular PE wear, 4 femoral loosening). Surgical approach was always antero-lateral. All patients were implanted with the same dual mobility cementless cup. The same cementless corail-type stem was used for primary THA cases. All the cemenless implants were hydroxyapatite coated. The disability caused by the disease was classified according to Hoehn and Yahr. (19 stage 1, 21 stage 2,16 stage 3). Results. 2 patients were lost for follow-up before 2 years. general complications were 3 pulmonary infection, 7 urinary tract infection, 12 cognitive impairment and 2 sacral pressure ulcer. A post-op. wound infection (E Coli) required an early revision in 2 cases without secondary consequencies (7 and 9 years follow-up). We did not observe early or late THA dislocation except in one case at 9 years follow-up (intraprosthetic dislocation due to an increase of ilio psoas muscle retraction requiring a revision of the dual mobility mechanism). We did not observe loosening cases of the cementless cup. 4 patients fell and fractured the femur. The cementless cup was not affected. 10 patients died. Good to excellent pain relief was achieved in 53/57cases at 2 years and in 40/47 cases at latest follow-up. The progression of neurological disability was observed in most of cases. At the latest follow-up for the 47 remaining patients, we had 5 stage 1, 12 stage 2, 21 stage 3,9 stage 4. Discussion. According to literature infection and dislocation are the main concerns for THA in Parkinson patients. This study does not report any trauma cases; this may explain the rather good results on a mean follow-up to more than 8 years. Nevertheless progression of Parkinson's disease is the rule, with significant disability or even death (10 /57 cases).
Unicompartmental Knee Replacement (UKR) is associated with fewer complications, faster recovery and better function than Total Knee Replacement (TKR). However, joint registries demonstrate a higher revision rate in UKR, limiting its use. Currently most UKRs are cemented and performed using a minimally invasive technique. In joint registries, common reasons for revision include aseptic loosening and pain. These problems could potentially be addressed by using cementless implants, which may provide more reliable fixation. The objectives of this study were to compare the quality of fixation (determined by the incidence and appearance of radiolucencies), and clinical outcomes of cemented and cementless UKR at five years. A randomised controlled trial was established with 63 knees (62 patients) randomised to either cemented (32 patients) or cementless UKR (30 patients). Fixation was assessed with fluoroscopic radiographs aligned to the bone-implant interface at one and five years. Outcome scores were collected pre-operatively and at one, two and five years, including Oxford Knee Score (OKS), American Knee Society Score, objective and functional (AKSS-O/F) and Tegner Activity Scale (TAS), expressed as absolute scores and 0–5 year change (δ) scores. Four patients died during the study period. There were no revisions. Mean operative time was 11 minutes shorter in the cementless group (p=0.029). At five years, there was no significant difference in any outcome measure except AKSS-F and δAKSS-F which were significantly better in the cementless group (both p=0.003). There were no femoral radiolucencies in either group. There were significantly more tibial radiolucencies in the cemented group (20/30 vs 2/27, p< 0.001). There were nine complete radiolucencies in the cemented group and none in the cementless group (p< 0.001).
Introduction: The new anatomical adapted stem system OptanTM (Zimmer) is presented, showing the first mid-term-results for cemented and
Introduction: Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components to the bone. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring
The Oxford Unicompartmental Knee Replacement's (OUKR's) fully-congruent design minimises polyethylene wear. Consequently, wear is a rare failure mechanism. Phase-3 OUKR linear wear at 5 years was higher than previous OUKR phases, but very low compared to fixed-bearing UKRs. This study aimed to measure OUKR bearing wear at 10 years and investigate factors that may affect wear. Bearing thickness for 39 OUKRs from a randomised study was calculated using radiostereometric analysis at regular intervals up to 10 years. Data for 39 and 29 OUKRs was available at 5 and 10 years, respectively. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years. Relationships between wear and patient factors, fixation method, Oxford Knee Score (OKS), bearing position, and component position were analysed.Abstract
Introduction
Methodology
Experience has demonstrated in the hip and knee, related to total joint replacement arthroplasty, polymethyl methacrylate cement fixation can provide problems in terms of loosening, fragmentation, particulate wear and ultimate failure. These same problems have been recognised in total shoulder arthroplasty related to cement fixation of the glenoid. While cement fixation of the humeral component has proven much less problematic, there has been a swelling towards avoidance of using cement to secure the humeral component for fear of difficulty if revision is required. Surprisingly, with the high incidence of lucent lines, bone resorption and frank loosening, representing the most common source of failure in total shoulder arthroplasty,
Biological fixation through bone ingrowth and ongrowth to implants can be achieved with a variety of surface treatments and technologies. This study evaluated the effect of two different three dimensional surface coatings for CoCr where porosity was controlled through the use of different geometry of CoCr beads in the sintering process. Test specimens in Group A were coated with conventional spherical porous-bead technology. The porous coating technology used on Group B was a variation of the conventional porous-bead technology. Instead of spherical beads, cobalt-chromium particles in irregular shapes were sieved for a particular size range, and were sintered onto the specimen substrate using similar process as Group A. The geometry and the size variation of the particles resulted in a unique 3D porous structure with widely interconnected pores. Three implants were placed bicortically in the tibia. Two implants were placed in the cancellous bone of the medial distal femur and proximal tibia bilaterally with 4 implantation conditions (2 mm gap, 1 mm gap line-to-line, and press fit). Animals were euthanized at 4 or 12 weeks for standard mechanical, histological and histomorphometric endpoints.Introduction
Methods
The acknowledged benefit of the direct anterior (DA) approach is early functional return. Most surgeons in the U.S. use cementless femoral replacement given the negative track record of some cemented designs. However, delayed osseointegration of a femoral stem typically seen in older patients with poor bone quality will delay recovery, diminishing the benefits of the DA approach. Registry studies have shown a higher revision rate and complications in this patient population leading to a renewed interest in cemented fixation. To achieve the functional benefits of the DA approach and the fixation benefits of cemented replacement, this study combined the 2 techniques posing the following questions:1) Does the limited access of the DA approach adversely affect the cement technique? 2) Does such a cementing technique reduce the incidence of cementless complications?Background
Questions posed
The cementless Oxford unicompartmental knee replacement
has been demonstrated to have superior fixation on radiographs and
a similar early complication rate compared with the cemented version.
However, a small number of cases have come to our attention where,
after an apparently successful procedure, the tibial component subsides into
a valgus position with an increased posterior slope, before becoming
well-fixed. We present the clinical and radiological findings of
these six patients and describe their natural history and the likely
causes. Two underwent revision in the early post-operative period,
and in four the implant stabilised and became well-fixed radiologically with
a good functional outcome. This situation appears to be avoidable by minor modifications
to the operative technique, and it appears that it can be treated
conservatively in most patients. Cite this article: