Advertisement for orthosearch.org.uk
Results 1 - 20 of 132
Results per page:
Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 509 - 509
1 Nov 2011
Vargas P Pinedo M Zumstein M Old J Boileau P
Full Access

Purpose of the study: Posterior fracture-impaction of the humeral head (Hill-Sachs defect or Malgainge notch) is a well-known factor of failure for arthroscopic shoulder stabilisation procedures. Recently, Wolf proposed arthroscopic posterior capsulodesis and tenodesis of the infraspinatus, or what we call in French Hill-Sachs Remplissage (filling). We hypothesised that capsule and tendon healing within the bony defect could explain the efficacy of this arthroscopic technique. Material and methods: Prospective clinical study of a continuous series. Inclusion criteria:. recurrent anterior instability (dislocation or subluxation);. isolated “engaged” humeral defect;. Bankart arthroscopy and Hill-Sachs remplissage;. arthroCT or MRI at least 6 months after surgery. Exclusion criteria:. associated bone loss in the glenoid;. associated rotator cuff tear. Twenty shoulders (20 patients) met the inclusion and exclusion criteria and underwent Hill-Sachs remplissage. Four orthopaedic surgeons evaluated independently the soft tissue healing in the humeral defect. Mann-Whitney analysis was used to search for a link between rate of healing and clinical outcome. Results: Filling of the humeral defect reached 75 to 100% in 16 patients (80%°; it was 50–75% in 4 patients. Healing was never noted less than 50%. The short-term clinical outcome (mean follow-up 11.4 months, range 6–32) showed an excellent results as assessed by the Constant score (mean 92±8.9 points) and the Walch-Duplay score (91 points). The subjective shoulder value (SSV) was 50% preoperatively and 89% at last follow-up. There were no cases of recurrent instability. This study was unable to establish a relationship between minor healing and less favourable clinical outcome. Discussion: This study confirmed our hypothesis that arthroscopic Hill-Sachs remplissage provides a high rate of significant healing in a majority of patients. Capsule and tendon healing in the humeral defect yields significant shoulder stability via at least two mechanisms:. prevention of defect engagement on the anterior border of the glenoid and. posterior force via improved muscle and tendon balance in the horizontal plane. Further mid- and long-term results will be needed to establish a confirmed correlation between healing and clinical outcome


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 21 - 21
17 Jun 2024
Jamjoom B Malhotra K Patel S Cullen N Welck M Clough T
Full Access

Background. Ankle and hindfoot fusion in the presence of large bony defects represents a challenging problem. Treatment options include acute shortening and fusion or void filling with metal cages or structural allograft, which both have historically low union rates. Impaction grafting is an alternative option. Methods. A 2 centre retrospective review of consecutive series of 32 patients undergoing hindfoot fusions with impaction bone grafting of morselised femoral head allograft to fill large bony void defects was performed. Union was assessed clinically and with either plain radiography or weightbearing CT scanning. Indications included failed total ankle replacement (24 patients), talar osteonecrosis (6 patients) and fracture non-union (2 patients). Mean depth of the defect was 29 ±10.7 mm and mean maximal cross-sectional area was 15.9 ±5.8 cm. 2. Tibiotalocalcaneal (TTC) arthrodesis was performed in 24 patients, ankle arthrodesis in 7 patients and triple arthrodesis in 1 patient. Results. Mean age was 57 years (19–76 years). Mean follow-up of 22.8 ±8.3 months. 22% were smokers. There were 4 tibiotalar non-unions (12.5%), two of which were symptomatic. 10 TTC arthrodesis patients united at the tibiotalar joint but not at the subtalar joint (31.3%), but only two of these were symptomatic. The combined symptomatic non-union rate was 12.5%. Mean time to union was 9.6 ±5.9 months. One subtalar non-union patient underwent re-operation at 78 months post-operatively after failure of metalwork. Two (13%) patients developed a stress fracture above the metalwork that healed with non-operative measures. There was no bone graft collapse with all patients maintaining bone length. Conclusion. Impaction of morselised femoral head allograft can be used to fill large bony voids around the ankle and hindfoot when undertaking arthrodesis, with rapid graft incorporation and no graft collapse despite early loading. This technique offers satisfactory union outcomes without the need for shortening or synthetic cages


Bone & Joint Research
Vol. 11, Issue 2 | Pages 82 - 90
7 Feb 2022
Eckert JA Bitsch RG Sonntag R Reiner T Schwarze M Jaeger S

Aims. The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. Methods. Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. Results. At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. Conclusion. Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. Cite this article: Bone Joint Res 2022;11(2):82–90


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 48 - 48
2 Jan 2024
Emmanuel A
Full Access

Non-linear methods in statistical shape analysis have become increasingly important in orthopedic research as they allow for more accurate and robust analysis of complex shape data such as articulated joints, bony defects and cartilage loss. These methods involve the use of non-linear transformations to describe shapes, rather than the traditional linear approaches, and have been shown to improve the precision and sensitivity of shape analysis in a variety of applications. In orthopedic research, non-linear methods have been used to study a range of topics, including the analysis of bone shape and structure in relation to osteoarthritis, the assessment of joint deformities and their impact on joint function, and the prediction of patient outcomes following surgical interventions. Overall, the use of non-linear methods in statistical shape analysis has the potential to advance our understanding of the relationship between shape and function in the musculoskeletal system and improve the diagnosis and treatment of orthopedic conditions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 85 - 85
2 Jan 2024
Zwingenberger S
Full Access

Spinal diseases such as unstable fractures, infections, primary or secondary tumors or deformities require surgical stabilization with implants. The long-term success of this treatment is only ensured by a solid bony fusion. The size of the bony defect, the often poor bone quality and metabolic diseases increase the risk of non-union and make the case a great burden for the patient and a challenge for the surgeon. The goal of spinal fusion can only be achieved if the implants used offer sufficient mechanical stability and the local biological regeneration potential is large enough to form sufficient bone. The lecture will present challenging clinical cases. In addition, implant materials and new surgical techniques are discussed. Local therapeutic effects are achieved through the release of osteopromotive or anti-resorbtive drugs, growth factors and antibiotics. By influencing biological pathways, basic orthopedic research has strong potential to further positively change future spinal surgery


Bone & Joint Open
Vol. 3, Issue 2 | Pages 114 - 122
1 Feb 2022
Green GL Arnander M Pearse E Tennent D

Aims. Recurrent dislocation is both a cause and consequence of glenoid bone loss, and the extent of the bony defect is an indicator guiding operative intervention. Literature suggests that loss greater than 25% requires glenoid reconstruction. Measuring bone loss is controversial; studies use different methods to determine this, with no clear evidence of reproducibility. A systematic review was performed to identify existing CT-based methods of quantifying glenoid bone loss and establish their reliability and reproducibility. Methods. A Preferred Reporting Items for Systematic reviews and Meta-Analyses-compliant systematic review of conventional and grey literature was performed. Results. A total of 25 studies were initially eligible. Following screening, nine papers were included for review. Main themes identified compared 2D and 3D imaging, as well as linear- compared with area-based techniques. Heterogenous data were acquired, and therefore no meta-analysis was performed. Conclusion. No ideal CT-based method is demonstrated in the current literature, however evidence suggests that surface area methods are more reproducible and lead to fewer over-estimations of bone loss, provided the views used are standardized. A prospective imaging trial is required to provide a more definitive answer to this research question. Cite this article: Bone Jt Open 2022;3(2):114–122


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 80 - 80
7 Nov 2023
Olivier A Vicatos G
Full Access

Custom 3D printed implants can be anatomically designed to assist in complex surgery of the bony pelvis in both orthopaedic oncology and orthopaedic reconstruction surgery. This series includes patients who had major pelvic bone loss after initially presenting with tumours, fractures or infection after previous total hip arthroplasty. The extent of the bone loss in the pelvis was severe and therefore impossible to be reconstructed by conventional ‘off –the-shelve’ implants. The implant was designed considering the remaining bony structures of the contra-lateral hemi- pelvis, to provide an anatomical, secured support for the reconstructed hip joint. The latter was realised by strategically orientated screws and by porous structures (an integral part of the implant), which stimulates osseointegration. A custom pelvic implant was designed, manufactured and 3D printed. Reconstruction of the pelvis was performed together with a cemented (bipolar bearing) acetabular cup. In some cases, a proximal femoral replacement was also necessary to compensate for bony defects. All patients had sufficient range of motion (ROM) at the hip with post-operative stability. It has been verified, at six and twelve months postoperatively, that there is a strong hold of the implant due to osseointegration. Additionally, in patients whose posterior acetabular wall was missing, it was discovered that the implant assisted in bone formation and covered the entire posterior surface of the implant. All patients in this study managed with this novel treatment option, proved to have a stable pelvic reconstruction with restoration of leg lengths, improvement of strength and independent ambulation at short and medium term follow-up


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 32 - 32
1 Oct 2022
Tøstesen S Stilling M Hanberg P Thillemann TM Falstie-Jensen T Tøttrup M Knudsen M Petersen ET Bue M
Full Access

Aim. Deadspace is the tissue and bony defect in a surgical wound after closure. This space is presumably poorly perfused favouring bacterial proliferation and biofilm formation. In arthroplasty surgery, an obligate deadspace surrounding the prosthesis is introduced and deadspace management, in combination with obtaining therapeutic prophylactic antibiotic concentrations, is important for limiting the risk of acquiring a periprosthetic joint infection (PJI). This study aimed to investigate cefuroxime distribution to an orthopaedic surgical deadspace in comparison with plasma and bone concentrations during two dosing intervals (8 h × 2). Method. In a setup imitating shoulder arthroplasty surgery, but without insertion of a prosthesis, microdialysis catheters were placed for cefuroxime sampling in a deadspace in the glenohumeral joint and in cancellous bone of the scapular neck in eighteen pigs. Blood samples were collected from a central venous catheter as a reference. Cefuroxime was administered according to weight (20 mg/kg). The primary endpoint was time above the cefuroxime minimal inhibitory concentration of the free fraction of cefuroxime for Staphylococcus aureus (fT > MIC (4 µg/mL)). Results. During the two dosing intervals, mean fT > MIC (4 µg/mL) was significantly longer in deadspace (605 min) compared with plasma (284 min) and bone (334 min). For deadspace, the mean time to reach 4 µg/mL was prolonged from the first dosing interval (8 min) to the second dosing interval (21 min), while the peak drug concentration was lower and half-life was longer in the second dosing interval. Conclusions. In conclusion, weight-adjusted cefuroxime fT > MIC (4 µg/mL) and elimination from the deadspace was longer in comparison to plasma and bone. Our results suggest a deadspace consolidation and a longer diffusions distance, resulting in a low cefuroxime turn-over. Based on theoretical targets, cefuroxime appears to be an appropriate prophylactic drug for the prevention of PJI. Acknowledgments. We would like to thank Department of Clinical Medicine, the surgical research laboratories, Aarhus University Hospital and Department of Clinical Biochemistry, Lillebaelt Hospital, Vejle, Denmark, for supporting this study. This research was funded by Novo Nordisk Foundation, grant number [NNF20OC0062032, 2020]


Full Access

Abstract. Approximately 20% of primary and revision Total Knee Arthroplasty (TKA) patients require multiple revisions, which are associated with poor survivorship, with worsening outcomes for subsequent revisions. For revision surgery, either endoprosthetic replacements or metaphyseal sleeves can be used for the repair, however, in cases of severe defects that are deemed “too severe” for reconstruction, endoprosthetic replacement of the affected area is recommended. However, endoprosthetic replacements have been associated with high complication rates (high incidence rates of prosthetic joint infection), while metaphyseal sleeves have a more acceptable complication profile and are therefore preferred. Despite this, no guidance exists as to the maximal limit of bone loss, which is acceptable for the use of metaphyseal sleeves to ensure sufficient axial and rotational stability. Therefore, this study assessed the effect of increasing bone loss on the primary stability of the metaphyseal sleeve in the proximal tibia to determine the maximal bone loss that retains axial and rotational stability comparable to a no defect control. Methods. to determine the pattern of bone loss and the average defect size that corresponds to the clinically defined defect sizes of small, medium and large defects, a series of pre-operative x-rays of patients with who underwent revision TKA were retrospectively analysed. Ten tibiae sawbones were used for the experiment. To prepare the bones, the joint surface was resected the typical resection depth required during a primary TKA (10mm). Each tibia was secured distally in a metal pot with perpendicular screws to ensure rotational and axial fixation to the testing machine. Based on X-ray findings, a fine guide wire was placed 5mm below the cut joint surface in the most medial region of the plateau. Core drills (15mm, 25mm and 35mm) corresponding to small, medium and large defects were passed over the guide wire allowing to act at the centre point, before the bone defect was created. The test was carried out on a control specimen with no defect, and subsequently on a Sawbone with a small, medium or large defect. Sleeves were inserted using the published operative technique, by trained individual using standard instruments supplied by the manufacturers. Standard axial pull-out (0 – 10mm) force and torque (0 – 30°) tests were carried out, recording the force (N) vs. displacement (mm) curves. Results. A circular defect pattern was identified across all defects, with the centre of the defect located 5mm below the medial tibial base plate, and as medial as possible. Unlike with large defects, small and medium sized defects reduced the pull-out force and torque at the bone-implant interface, however, these reductions were not statistically significant when compared to no bony defect. Conclusions. This experimental study demonstrated that up to 35mm radial defects may be an acceptable “critical limit” for bone loss below which metaphyseal sleeve use may still be appropriate. Further clinical assessment may help to confirm the findings of this experimental study. This study is the first in the literature to aim to quantify “critical bone loss” limit in the tibia for revision knee arthroplasty. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 150 - 150
1 Mar 2017
Shon W Dwivedi C Kim T Kim H
Full Access

Although total hip arthroplasty is highly successful for treatment of osteoarthrosis of hip joint, it is skill demanding surgery to perform and even more challenging in case of revision with bone defects. There are many options available for reconstruction of acetabular bony defects. Here, we evaluate the outcome of acetabular bony defect reconstructed with trabecular metal augments in short term. We performed, 22 revision total hip arthroplasties and 6 primary total hip arthroplasties (total 28 in 28 patients) using trabecular metal augments to reconstruct acetabular defect between 2011 to 2015. Out of these 28 patients, 18 were males and 10 were females. Mean age of these patients was 61.2 years (range: 46 years to 79 years). Pre-operative templating was done for all cases and need for trabecular metal augments was anticipated in all cases. All cases were classified according to Paprosky classification for acetabular bone defects. Out of 28 patients, 3 had type 2B, 1 had type 2C, 18 had type 3A and 6 had type 3B acetabular defects. Post operatively, all patients were followed at regular interval for their clinical and radiological outcome. An average follow up was 20.1 months (range: 6 months to 42.5 months). We assessed clinical outcome in the form of Herris hip score (HHS) and radiological outcomes in form of osteolysis in acetabular zones and osseointegration, according to the criteria of Moore. The average Harris hip score (HHS) was improved from 58.0 preoperatively to 87.2 postoperatively. The average degree of cup abduction at the final follow up was 44.29. The centre of rotation of the hip joint was corrected from average 38.90mm (range: 22.15mm to 66.35mm) above the inter-teardrop line preoperatively to average 23.85mm (range: 11.82mm to 37.69mm) above the inter-teardrop line postoperatively. Out of 28 patients, 18 patients had three or more signs of osseointegration, according to the criteria of Moore, at the time of final follow up. Rest of patients, had one or two signs of osseointegration (5 patients had one sign and 5 patients had two signs). We had no patient with migration or loosening of acetabular components. No patient has osteolysis of acetabulum in any zone. Trabecular metal augments provide good initial stability to acetabular cup as well as helpful to bring down the centre of rotation of the hip joint within limit of 35mm above the inter-teardrop line. They also facilitate osseointegration. Our study showed that the results of the trabecular metal augments in reconstruction of acetabular bony defects were successful even in short term. However, long term study is required for better evaluation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 121 - 121
1 Jan 2016
Kokubo Y Uchida K Sugita D Oki H Negoro K Inukai T Miyazaki T Nakajima H Yoshida A Baba H
Full Access

Total hip arthroplasty (THA) is one of the preferable solutions for regaining ambulatory activity for patients with end-stage osteoarthritis, and the procedure is well developed technically and large numbers of patients benefit from THA worldwide. However, despite the improvements in implant designs and surgical techniques, revision rates remain high, and the number of revisions is expected to increase in the future as a result of the increase in the volume of primary THA and the increase in the proportion of younger, more active patients who are likely to survive longer than their prosthetic implants. In revision THA, associated loss of bone stock in the acetabulum presents one of the major challenges. The aim of the present study was to analyze the clinical and radiographic outcomes and Kaplan-Meier survivorship of patients underwent revision surgeries of the acetabular cup sustaining aseptic loosening. We reviewed consecutive 101 patients (120 hips; 10 men 11 hips; 91 women 109 hips; age at surgery, 66 years, range, 45–85) who underwent acetabular component revision surgery, at a follow-up period of 14.6 years (range, 10–30). For the evaluation of the state of the acebtabulum, acetabular bony defects were classified according to the classification of the AAOS based on the intraoperative findings as follows; type I [segmental deficiencies] in 24 hips, type II [cavity deficiency] in 48 hips, type III [combined deficiency] in 46, and type IV [pelvic discontinuity] in 2. Basically, we used the implant for acetabular revision surgery that cement or cementless cups were for the AAOS type I acetabular defects, cementless cup, or cemented cup with reinforcement device were for type II, cemented cup with reinforcement device were for type III. Follow-up examination revealed that Harris Hip score improved from 42.5±7.8 points before surgery to 76±16.2 points (p<0.05). The survival rates of the acetabular revision surgery with cemented cups, cementless cups, and cemented cups with reinforcement devices were 65.1%, 72.8%, and 79.8%, respectively, however, there was no significant differences between the groups. There were nine cases, which failed in the early stage in the groups of cementless cups and cemented cups with reinforcement devices, because of the instability of the cementless cups or breakage of reinforcement plates caused by inadequate bone grafting. We conclude that the usage of the cementless cups for type I and II acetabular bony defects, and the cemented cups with reinforcement devices for type III bony defects will demonstrate durable long-term fixation in case of adequate contact between acetabular components and host-bone with restoration of bone stock by impaction bone grafting


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 81 - 81
1 Jan 2016
Choi CH Chung KS Lee JK Lee HJ
Full Access

Introduction. The purpose of this study was to evaluate the mid-term clinical and radiological results in patients who were managed by double metal augmentations in proximal tibial uncontained bony defects undergoing primary or revision total knee arthroplasty. Materials and Methods. We performed double metal augmentations in proximal tibial uncontained bony defects undergoing total knee arthroplasty. Out of total 14 patients, 8 patients (4 priamry arthroplasty, 4 revision arthroplasty), mean 61.3 (50–80) years, were available for review at least 5 years follow up. The average follow up period was 86.3(60–99) months. Range of motion, American Knee Society Score were evaluated pre- and postoperatively as a clinical values. Another clinical assessments undertaken at the final reviews, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford knee score (OKS), Short Form-36 (SF-36), Lower extremity functional scale (LEFS), and Lower extremity activity scale (LEAS) were checked. Radiological results, involving presence of radiolucent lines (RLLs) > 1mm in width, and osteolysis at the block-cement-bone interface were taken under fluoroscopic images at postoperatively and annually thereafter. Results. At the final follow-up, range of motion was increased from 97.5° to 121.3° and American Knee society score was significantly improved from 30.4 to 92.6 (p=0.03) and functional score from 43.1 to 86.9 (p=0.03). At the final follow-up, average WOMAC score was 10(2–20), OKS was 40.5(33–47), LEFS was 55.8(34–75), and LEAS was 10.9(7–15). There was no broken or deterioration sign at between first and second metal block at radiographically. RLLs at the block-cement-bone interfaces under fluoroscopic images were examined in 3 knees, but didn't cause any failure sign such as osteolysis, or collapse, or instability at final reviews. Conclusions. The clinical and radiological evaluations showed that the double metal augmentations is a favorable and useful way to manage severe uncontained proximal tibial bony defects at least 5 years mid-term follow up period. Preoperative standing anteroposterior (AP) radiograph (Fig 1) shows severe uncontained proximal tibial bone defects, approximately 23 mm compared with unaffected lateral tibial condyle. AP view of fluoroscopy with medial double metal blocks (10 mm block + down sized 10 mm block) combined intramedullary stem at 60-month follow-up after primary total knee arthroplasty, demonstrating radiolucent line (white arrow) of 2.5 mm width bottom the block (Fig 2). AP view at 92-month follow-up indicating non-progressive stable radiolucent lines (white arrow) at same area without any radiographic failure signs and broken sign between first and second metal block (Fig 3)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 53 - 53
1 Dec 2017
Henckel J Durand-Hill M Noory S Skinner J Hart A
Full Access

Additive manufacturing has enabled a radical change in how surgeons reconstruct massive acetabular defects in revision hip surgery. We report on the early clinical and radiological results from our methods for surgical planning, design, and implantation of 3D printed trabecular titanium implants in a cohort of patients with large unclassifiable pelvic defects. We set up a prospective investigation involving 7 consecutive patients. Inclusion criteria was the following: 1) A history of previous total hip replacement; and 2) Current imaging showing at least a Paprosky 3B defect. Planned acetabular inclination and version was 40° and 20° respectively. Post operatively all patients had a CT scan which was analysed with software to determine component position and compared to planned. Outpatient review was done at 2 weeks (For wound), 6 weeks (for weight bearing and fixation) and 52 weeks (for fixation and infection) post-operative. The median age at surgery was: 65 years (40–78). The median bone defect volume was 140cm. 3. Median surgery length was 5.2 hours (3–6.25). Median blood loss was 1300mL (450– 2000). Radiologically, components were stable and no screw breakages were identified. Achieved inclination was 41.0° (29.0–55.6) and achieved version was 15.8° (3.8–43.6). Median Oxford Hip score improved from 9 (2–44) to 25 (18–32). We have demonstrated a new series of pre, intra and post-operative methods for reconstruction of unclassifiable acetabular bony defects. Initial clinical and radiological results are excellent considering the severity of the bony defects. We recommend the use of our or similar methods when trying to reconstruct these defects


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 91 - 91
1 May 2016
Nurkovic J Ramovic A Nurkovic S Kurtagic I Dolicanin Z
Full Access

Bone is capable of regeneration, and defects often heal spontaneously. However, cartilage, tendon, and ligament injuries usually result in replacement if the site by organized scar tissue, which is inferior to the native tissue. The osteogenic potential of mesenchymal stem cells (MSCs) has already been verified. MSCs hold great potential for the development of new treatment strategies for a host of orthopedic conditions. The multi-lineage potential and plasticity of MSCs allow them to be building blocks for a host of nonhematopoietic tissues, including bone. More recently, several groups have reported on the successful clinical application of tissue engineering strategies in the repair of bony defects in patients secondary to trauma and tumor resection. Advances in fabrication of biodegradable scaffolds that serve as beds for MSC implantation will hopefully lead to better biocompatibility and host tissue integration. Current strategies for bone tissue engineering include the use of osteoconductive matrix devices that promote bony ingrowth, and the delivery of osteoinductive growth factors, including bone morphogenetic protein (BMP) family, BMP-2 and BMP-7, to bony defect sites. Minimal toxicity has been observed in animal models involving genetically-manipulated stem cells transduced with retroviral and adenoviral vectors. Gene therapy using stem cells as delivery vehicles is a powerful weapon that can be used in a plethora of clinical situations that would benefit from the osteoinductive, proliferative, and angiogenic effects of growth factors. With better understanding of the biology of stem cells in the future and with enhancement of technologies that are capable to influence, modify, and culture these cells, a new field of regenerative skeletal medicine may emerge


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 166 - 166
1 Mar 2010
Jerosch J
Full Access

Introduction: Shoulder surface replacement arthroplasty has been established for several decades as a mean to restore comfort and function of the shoulder for many afflictions that derange the normal anatomy. The surface replacement may offer some advantages over the stemmed prostheses. Purpose: The purpose of the study was to evaluate the clinical and radiological results of Copeland cementless surface replacement arthroplasty (CSRA) applied in patients with bony defects of the humeral head. Patients and Methods: The study was conducted on 18 patients (2 patients with chronic posterior dislocation, 8 patients with AVN, 8 patients with posttraumatic head necrosis) with bony head defects that were operated on between 1999 and 2006. The patients were followed up clinically and radiologically for a mean of 24.8 months (range, 10–78 months). There were 8 female and 10 male shoulders. The mean age was 55.3 years (range, 27–71). The clinical assessment was performed with the Constant score. Results: The constant score significantly improved from a mean of 14.83 points preoperatively to 64.34 points postoperatively. The average pain score increased from 0.3 points to 9.8 points. The average ROM score increased from 8.21 points to 23.21 points. The humeral offset increased from 22.3 mm to 28.8 mm. Conclusion: The shoulder surface replacement arthroplasty shows good mid-term results in patients with bony defects


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 4 - 4
1 May 2016
Lo H
Full Access

Introduction. Osteoporotic intertrochanteric fracture (ITF) is frequent injuries affecting elderly, osteoporotic patients leading to significant morbidity and mortality. Successful prognosis including union and alignment is challenging even though initial successful reduction with internal fixation. Although many factors are related to the patient's final prognosis. Well reduction with stable fracture fixation is still the goal of treatment to improve the quality of life and decrease morbidity in patients with hip fractures, but this in turn depends on the type of fracture and bone quality. Poor bone quality is responsible for common complications, such as failure of fixation, varus collapse and lag screw cut-out, in elderly patients. Kim et al. found that the complication rate when using conventional DHS in unstable ITFs can be as high as 50% because of screw cut-out. We used the dynamic hip screws (DHS) strengthened by calcium phosphate cement (CPC) for treatment femoral intertrochanteric fracture and review the prognosis of our patients. Materials and Methods. From January of 2011 to January of 2014, 42 patients with femoral intertrochanteric fracture underwent surgery with DHS strengthened by CPC. Comparisons were made between the DHS plus CPC group with the other patients with only DHS used in our department. All patients were followed up for an average time of 14.8(6 to 24) months. X-ray was reviewed for the conditions of union and implant failure. Results. In DHS group, fixation failure happened in 3 case, delayed union and coax varus deformity in 2 cases. IN DHS plus CPC group, all fractures healed uneventfully, there is no non-union or malunion in this group. There is only 1 fixation cut-out and 1 secondary lag screw sliding was noted, however, union was still well over fracture site in this case, the patient had no clinical symptoms. Discussion. Residual bony defects present after DHS fixation in intertrochanteric fracture may lead to postoperative complications, including nonunion or implant failure. DHS strengthened by CPC is reliable fixation for old patients with intertrochanteric fracture, We demonstrated that augmentation of the bony defect with dynamic hip screw by reinforced calcium phosphate cement significantly improved the strength of osteoporotic bone, prevent screw loosening, and promote early healing of fracture. The patients can be decreased the risk of refracture and allow early weight bearing, especially in elderly patients with osteoporotic bone


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 28 - 28
1 Dec 2014
van der Jagt D Pietzrak J Hanna M Mokete L
Full Access

Background:. Massive acetabular defects remain an unresolved challenge in revision arthroplasty surgery of the hip. We report on 7 patients treated with custom made acetabular components to manage these massive boney defects. Methods:. After high resolution CT scans were done, custom made implants were designed in collaboration between the surgeons and the manufacturer. All implants matched the bony defects as designed. Results:. There were 6 female and 1 male patients. The average age was 54 years, and on average each patient had had 9 previous revision procedures to the hip. All had Paprosky type 111B defects. The average surgical time for the procedure was 2.6 hours. The average time in hospital post-operation was 6 days. The average follow-up post index procedure was 13 months. Two implants needed to be explanted because of sepsis. One device was re-implanted after the infection was eradicated. One patient needed re-operation because of recurrent dislocations. All 6 surviving implants have remained well fixed with no radiological evidence of loosening. We did a cost analysis including the cost of the previous revision procedures, the cost of alternative acetabular hardware constructs, and the cost of the custom made implants. These custom made implants are cost effective in the clinical setting. Conclusion:. Massive acetabular bony defects remain an ongoing challenge, and we have presented a viable option in respect of these cases which is cost effective and durable in the short term


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 66 - 66
1 Jul 2020
Tat J Chong J Powell T Martineau PA
Full Access

Anterior shoulder instability is associated with osseous defects of the glenoid and/or humeral head (Hill-Sachs lesions). These defects can contribute to the pathology of instability by engaging together. There is a need to continue to develop methods to preoperatively identify engaging Hill-Sachs lesions for determining appropriate surgical management. The objective was to created a working moveable 3D CT model that allows the user to move the shoulder joint into various positions to assess the relationship between the Hill-Sachs lesion and the anterior glenoid rim. This technique was applied to a cohort series of 14 patients with recurrent anterior dislocation: 4 patients had undergone osteoarticular allografting of Hill-Sachs lesions and 10 control patients had undergone CT scanning to quantify bone loss but had no treatment to address bony pathology. A biomechanical analysis was performed to rotate each 3D model using local coordinate systems through a functional range using an open-source 3D animation program, Blender (Amsterdam, Netherlands). A Hill-Sachs lesion was considered “dynamically” engaging if the angle between the lesion's long axis and anterior glenoid was parallel. In the classical vulnerable position of the shoulder (abduction=90, external rotation=0–135), none of the Hill-Sachs lesions aligned with the anterior glenoid in any of our patients (Figure 1). Therefore, we considered there to be a “low risk” of engagement in these critical positions, as the non-parallel orientation represents a lack of true articular arc mismatch and is unlikely to produce joint instability. We then expanded our search and simulated shoulder positions throughout a physiological range of motion for all groups and found that 100% of the allograft patients and 70% of the controls had positions producing alignment and were “high risk” of engagement (p = 0.18) (Table 1). We also found that the allograft group had a greater number of positions that would engage (mean 4 ± 1 positions of engagement) compared to our controls (mean 2 ± 2 positions of engagement, p = 0.06). We developed a 3D animated paradigm to dynamically and non-invasively visualize a patient's anatomy and determine the clinical significance of a Hill-Sachs lesion using open source software and CT images. The technique demonstrated in this series of patients showed multiple shoulder positions that align the Hill-Sachs and glenoid axes that do not necessarily meet the traditional definition of engagement. Identifying all shoulder positions at risk of “engaging”, in a broader physiological range, may have critical implications towards selecting the appropriate surgical management of bony defects. We do not claim to doubt the classic conceptual definition of engagement, but we merely introduce a technique that accounts for the dynamic component of shoulder motion, and in doing so, avoid limitations of a static criteria assumed traditional definition (like size and location of lesion). Further investigations are planned and will help to further validate the clinical utility of this method. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 405 - 405
1 Jul 2010
O’Toole P Noonan M North A Stratton J Kiely P Noel J Fogarty E Moore D
Full Access

Introduction: Bone transport, or distraction osteogenesis, is a recognised technique to reconstruct extensive bony defects resulting from excision of bony tumours. Ilizarov demonstrated bone formation under tension allowing the movement of a free segment of living bone to fill intercalary defects. This study assesses the use of bone transport in the management of patients with resectable long bone tumours. Methods: We retrospectively reviewed patients who underwent bone transport in two institutions, performed by a single surgeon. A total of 14 patients were included in the study. There were 11 males and 3 females. Histological results demonstrated osteosarcoma (n=7), Ewing’s sarcoma (n=6), and parosteal chondrosarcoma (n=1). The site of the tumour was the femur and tibia in 8 and 6 cases respectively. Results: Bone transport was fully completed in 9 patients. Of the 5 patients remaining, 3 are currently in cast, 1 is currently undergoing tibial lengthening, and 1 patient died from local recurrence and distant spread of disease. The average length of bone resected in the tibia was 11 cm (range 8–15 cm), while in the femur the average was higher at 16.5 cm (range 12–27 cm). All patients underwent autologous bone grafting of their docking site from either the anterior or posterior iliac crest on the ipsilateral side. The average time in frame was 24.8 months. One patient undergoing tibial bone transport fell and sustained an ipsilateral supracondylar femoral fracture which was successfully treated with an external ring fixator. Discussion: Bone transport is a recognised method of reconstructing extensive bony defects and is beneficial for patients with a good prognosis. It is a specialised technique and requires a multidisciplinary approach. Other techniques can be less time consuming however distraction osteogenesis avoids the complications associated with prosthetic or allograft replacements


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 1 - 1
1 Oct 2012
Fieten L Eschweiler J Kabir K Gravius S Randau T Radermacher K
Full Access

Cup position planning for total hip replacement (THR) is a complex task which is influenced by several factors. Whereas aspects like appropriate implant fixation and bone stock preservation are rather evaluated according to intra-operative findings, functional analyses using biomechanical hip models can rely on pre-operative imaging. Due to the wide availability and cost-efficiency of X-ray imaging technology along with the common restriction of biomechanical evaluations to the frontal plane, pre-operative imaging for such purposes is usually limited to AP radiographs. One example is biomechanical optimisation based on the so-called BLB score, which has already been introduced into clinical practice. In this approach, the assumed suitability of potential hip centres of rotation (CORs) is presented to the surgeon by applying colour-coding within the pre-operative AP radiograph. However, to realise the plan, the surgeon has to transfer the 2D positions presented in the radiograph into the 3D surgical site. We developed a CT-based simulation tool allowing for the generation of 3D bone surface models as well as standardised digitally reconstructed radiographs (DRRs). Within a 3D view, the cup, which is represented as a hemisphere, can freely be shifted in the coronal plane. The 2D point corresponding to the COR defined by the hemisphere is then automatically computed. In our study, four CT datasets of hips with large bony defects were used. After segmentation 3D bone surface models were generated. These bone surface models were aligned on the basis of the pelvic coordinate system [3], and standardised AP DRRs were computed. BLB score evaluation in intact hips assumes that the central beam passes through the centroid of both hip CORs. As only the contra-lateral hip COR was available due to the defects, a virtual ipsi-lateral COR was obtained by mirroring the contra-lateral hip across the mid-sagittal plane. Twelve surgeons (divided into two groups of six each according to their experience) had the task to shift the cup such that its 3D position would best match a predefined 2D target position, which was close to the virtual ipsi-lateral COR and displayed as a cross within the standardised DRR. However, the current 2D position corresponding to the current 3D position was not revealed during positioning. Once the user was satisfied with the 3D position, the corresponding 2D position was recorded. The following results were obtained (mean ± SD across six surgeons of the respective group) for the four patients:. x-error, more experienced: 2.0 ± 6.1; −3.0 ± 5.9; 4.1 ± 4.8; 2.1 ± 5.2; x-error, less experienced: 4.3 ± 4.2; −3.1 ± 1.8; 1.9 ± 4.0; 5.2 ± 4.1; |x-error|, more experienced: 5.2 ± 3.0; 5.4 ± 3.2; 5.5 ± 2.7; 4.3 ± 3.0;|x-error|, less experienced: 4.3 ± 4.2; 3.1 ± 1.8; 3.3 ± 2.7; 5.7 ± 3.3; y-error, more experienced: 12.0 ± 9.1; 0.3 ± 4.3; 6.2 ± 6.6; 1.9 ± 3.2;. y-error, less experienced: 6.1 ± 3.1; 0.8 ± 4.0; 2.4 ± 5.5; 1.4 ± 4.1;|y-error|, more experienced: 12.0 ± 9.1; 3.2 ± 2.6; 6.2 ± 6.6; 3.0 ± 1.9;|y-error|, less experienced: 6.1 ± 3.1; 3.4 ± 1.6; 4.6 ± 3.3; 3.2 ± 2.6;total error, more experienced: 13.5 ± 8.9; 6.6 ± 3.5; 9.8 ± 4.1; 5.4 ± 3.4;total error, less experienced: 8.5 ± 2.7; 4.9 ± 1.5; 6.5 ± 2.5; 6.7 ± 3.8. Our experimental results show that mental 2D/3D matching for cup positioning in pelvises with bony defects is a difficult task, and that mental 2D/3D matching cannot be expected to yield the correct 3D cup positions corresponding to positions predefined in radiographs. The largest errors were found in the patient with the lowest image quality suggesting that image quality plays an important role. On contrary, experience was not found to be an important factor. We believe that in clinical practice mental 2D/3D matching between pre-operative radiographs and the surgical site without the help of 3D imaging or special tools would be more difficult than the task given in this study because only small portions of the pelvis would be exposed. Furthermore, as additional aspects of cup positioning would need to be taken into consideration simultaneously, the mental load could be expected to be higher. We conclude that in hips with large bony defects cup positioning based on pre-operative radiographs is highly unreliable without additional computer-assistance or intra-operative imaging. If pre-operative radiographs are needed for functional analyses, combination with 3D image data seems attractive: Firstly, 3D images can easily be used for navigation; secondly, they allow for the generation of highly standardised views, which is essential for comparability across multiple patients. Future studies relying on more datasets with a wider range of defects could also investigate whether cranio-caudal or medio-lateral positioning errors prevail. This is an interesting question since the BLB score usually is much more specific in the medio-lateral direction than in the cranio-caudal direction, implying that correct 2D/3D matching for the cranio-caudal direction appears less important. In the current study involving only four hips, however, no clear tendency could be observed. This work has been funded in part by the German Ministry for Education and Research (BMBF) in the framework of the orthoMIT project under grant No. BMBF 01EQ0802/BMBF 01IBE02C