Advertisement for orthosearch.org.uk
Results 1 - 20 of 140
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 31 - 31
1 Apr 2022
Langton D Bhalekar R Joyce T Shyam N Nargol M Pabbruwe M Su E Nargol A
Full Access

Cobalt chrome alloy is commonly used in joint replacement surgery. However, it is recognised that some patients develop lymphocyte mediated delayed type hypersensitivity (DTH) responses to this material, which may result in extensive bone and soft tissue destruction. Phase 1. United Kingdom: From an existing database, we identified extreme phenotype patient groups following metal on metal (MoM) hip resurfacing or THR: ALVAL with low wearing prostheses; ALVAL with high wear; no ALVAL with high wear; and asymptomatic patients with implants in situ for longer than ten years. Class I and II HLA genotype frequency distributions were compared between these patients’ groups, and in silico peptide binding studies were carried out using validated methodology. Phase 2. United Kingdom: We expanded the study to include more patients, including those with intermediary phenotypes to test whether an algorithm could be developed incorporating “risk genotypes”, patient age, sex and metal exposure. This model was trained in phase 3. Phase 3. United Kingdom, Australia, United States. Patients from other centres were invited to give DNA samples. The data set was split in two. 70% was used to develop machine learning models to predict failure secondary to DTH. The predictions were tested using the remaining blinded 30% of data, using time-dependent AUROCs, and integrated calibration index performance statistics. A total of 606 DNA samples, from 397 males and 209 female patients, were typed. This included 176 from patients with failed prostheses, and 430 from asymptomatic patients at a mean of >10 years follow up. C-index and ROC(t) scores suggested a high degree of discrimination, whilst the IBS indicated good calibration and further backed up the indication of high discriminatory ability. At ten years, the weighted mean survival probability error was < 4%. At present, there are no tests in widespread clinical use which use a patient's genetic profile to guide implant selection or inform post-operative management. The algorithm described herein may address this issue and we suggest that the application may not be restricted to the field of MoM hip arthroplasty


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 28 - 28
10 May 2024
Warindra T
Full Access

Discoid meniscus (DM) is a congenital variant of the knee joint that involves morphological and structural deformation, with potential meniscal instability. The prevalence of the Discoid Lateral Meniscus (DLM) is higher among the Asians than among other races, and both knees are often involved. Meniscal pathology is widely prevalent in the adult population, secondary to acute trauma and chronic degeneration. The true prevalence in children remains unknown, as pathologies such as discoid menisci often go undiagnosed, or are only found incidentally. A torn or unstable discoid meniscus can present with symptoms of knee pain, a snapping or clicking sensation and/or a decrease in functional activity, although it is not known if a specific presentation is indicative of a torn DM. While simple radiographs may provide indirect signs of DLM, magnetic resonance imaging (MRI) and arthroscopy is essential for diagnosis and treatment planning. Asymptomatic patients require close follow-up without surgical treatment, while patients with symptoms often require surgery. Partial meniscectomy is currently considered the treatment of choice for DLM. For children are more likely to achieve better results after partial meniscectomy


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 8 - 8
23 Jun 2023
Baujard A Martinot P Demondion X Dartus J Girard J Migaud H
Full Access

Mechanical irritation or impingement of the iliopsoas tendon accounts for 2–6% of persistent postoperative pain cases after total hip arthroplasty (THA). The most common trigger is anterior cup overhang. CT-scan can be used to identify and measure this overhang; however, no threshold exists for symptomatic anterior iliopsoas impingement. We conducted a case–control study in which CT-scan was used to define a threshold that differentiates patients with iliopsoas impingement from asymptomatic patients after THA. We analyzed the CT-scans of 622 patients (758 CT-scans) between 2011 and 2020. Out of this population we identified 136 patients with symptoms suggestive of iliopsoas impingement. Among them, 6 were subsequently excluded: three because the diagnosis was reestablished intra-operatively (one metallosis, two anterior instability related to posterior prosthetic impingement) and three because they had another obvious cause of impingement (one protruding screw, one protruding cement plug, one stem collar), leaving 130 patients in the study (impingement) group. They were matched to a control group of 138 patients who were asymptomatic after THA. The anterior cup overhang (anterior margin of cup not covered by anterior wall) was measured by an observer (without knowledge of the clinical status) on an axial CT slice based on anatomical landmarks (orthogonal to pelvic axis). The impingement group had a median overhang of 8 mm [IQR: 5 to 11] versus 0 mm [IQR: 0 to 4] for the control group (p<.001). Using ROC curves, an overhang threshold of 4 mm was best correlated with a diagnosis of impingement (sensitivity 79%, specificity 85%, PPV = 75%, NPV = 85%). Pain after THA related to iliopsoas impingement can be reasonably linked to acetabular overhang if it exceeds 4 mm on a CT scan. Below this threshold, it seems logical to look for another cause of iliopsoas irritation or another reason for the pain after THA before concluding impingement is present


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 67 - 67
19 Aug 2024
Millis MB Maroyan A Mendola L Matheney T
Full Access

The periacetabular osteotomy(PAO) is an effective common hip-preserving procedure to treat symptomatic acetabular dysplasia of the hip (DDH). The literature regarding truly long-term patient outcomes after PAO remains limited. We sought to evaluate our patient cohort treated by PAO 25 to 33 years ago to identify factors positively and negatively associated with durable therapeutic success. 219 dysplastic hips (183 patients) underwent PAO between August 1991 and December 1999 by a single surgeon. 164 hips in 134 patients were retrospectively evaluated at minimum of 25 years and maximum of 33 years post-operatively. Hips were evaluated using the pain subscale of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) postoperatively. Osteotomy failure was defined as WOMAC pain score of >/=10 or the need for total hip arthroplasty (THA). 7 patients (7 hips) had died - none of whom had THR. 142/176 remaining patients were located. All patients returned questionnaires; some were seen in person with images. Of patients analyzed to date, 109 hips (63%) were asymptomatic/mildly symptomatic with a preserved hip. 58 hips (33%) had undergone THA. 7 preserved hips (5%) were symptomatic (WOMAC>10). Patients with THA were slightly older than asymptomatic patients (54 ± 8 years vs. 50 ± 11 years; p=0.08), as they had been at time of PAO. Most patients were female (83%), with 89% of hip replacement patients being female. 4/58 replaced hips had been revised - 3 for instability and 1 for acetabular loosening. Data collection is ongoing as more patients are located and reviewed. Long-term follow-up of patients is challenging. Review after minimum of 25 years of the Boston cohort treated with PAO after minimum of 25 years dysplasia reveals that most at long-term follow-up report high levels of function, whether or not they had required arthroplasty, although 33% had required interim treatment with THA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 22 - 22
1 Dec 2022
Werle J Kearns S Bourget-Murray J Johnston K
Full Access

A concern of metal on metal hip resurfacing arthroplasty is long term exposure to Cobalt (Co) and Chromium (CR) wear debris from the bearing. This study compares whole blood metal ion levels from patients drawn at one-year following Birmingham Hip Resurfacing (BHR) to levels taken at a minimum 10-year follow-up. A retrospective chart review was conducted to identify all patients who underwent a BHR for osteoarthritis with a minimum 10-year follow-up. Whole blood metal ion levels were drawn at final follow-up in June 2019. These results were compared to values from patients with one-year metal ion levels. Of the 211 patients who received a BHR, 71 patients (54 males and 17 females) had long term metal ion levels assessed (mean follow-up 12.7 +/− 1.4 years). The mean Co and Cr levels for patients with unilateral BHRs (43 males and 13 females) were 3.12 ± 6.31 ug/L and 2.62 ± 2.69 ug/L, respectively, and 2.78 ± 1.02 ug/L and 1.83 ± 0.65 ug/L for patients with bilateral BHRs (11 males and 4 females). Thirty-five patients (27 male and 8 female) had metal-ion levels tested at one-year postoperatively. The mean changes in Co and Cr levels were 2.29 ug/l (p = 0.0919) and 0.57 (p = 0.1612), respectively, at one year compared to long-term. These changes were not statistically significant. This study reveals that whole blood metal ion levels do not change significantly when comparing one-year and ten-year Co and Cr levels. These ion levels appear to reach a steady state at one year. Our results also suggest that regular metal-ion testing as per current Medicines and Healthcare products Regulatory Agency (MHRA) guidelines may be impractical for asymptomatic patients. Metal-ion levels, in and of themselves, may in fact possess little utility in determining the risk of failure and should be paired with radiographic and clinical findings to determine the need for revision


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 66 - 66
17 Nov 2023
Rajab A Ponsworno K Keehan R Ahmad R
Full Access

Abstract. Background. Post operative radiographs following total joint arthroplasty are requested as part of routine follow up in many institutions. These studies have a significant cost to the local departments, in terms of financial and clinic resources, however, previous research has suggested they may not alter the course of the patients treatment. The purpose of this study was to assess the significance of elective post operative radiographs on changes in management of patients who underwent total joint arthroplasty. Method. All patients who underwent total knee arthroplasty and total hip arthroplasty at a District General Hospital from 2019 to 2020 were included. Data was collected retrospectively from medical records and radiograph requests. Alterations to clinical management based on radiographic findings were reviewed in clinic letters. Results. A total of 227 Total joint arthroplasty were retrieved. With 111(49%) total hip arthroplasty and 116 (51%) total knee arthroplasty. 54 were excluded due to having no clinical follow up and 173 met inclusion criteria. 56 (32%) had their post operative elective radiograph, while 93 (53.8%) patients had none. There were no abnormalities detected from the elective radiographs and none of the patients returned to the theatre. 24 patients (13%) presented with symptoms and had non-elective radiographs, 16 (67%) did not have any interventions and 8 (4.6%) required intervention and were taken to theatre. Discussion: Not performing these radiographs saves time, cost, and prevents unnecessary radiation exposure. In our institution, a 2-view joint radiograph costs £29 and takes roughly 15 minutes. This does not include indirect costs of additional clinic time and patient waiting time. In the larger context, the cost associated with elective radiographs is significant and our data suggests that routine post-operative radiographs are not beneficial as part of standard post-operative protocol for asymptomatic patients. However, performing imaging remains beneficial for patients who re-present with symptoms. Conclusion. Routine elective post-operative joint radiographs did not detect any true abnormalities. Information from elective radiographs has no clinical significance and did not change management. Therefore, this study recommends that there is no rationale requesting elective post-operative joint radiographs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 3 - 3
7 Jun 2023
Verhaegen J Devries Z Horton I Slullitel P Rakhra K Beaule P Grammatopoulos G
Full Access

Traditional radiographic criteria might underestimate or fail to detect subtle types of acetabular dysplasia. Acetabular sector angles (ASA) can measure the degree of anterior and posterior coverage of the femoral head on computed tomography (CT). This study aims to determine ASA values at different axial levels in a cohort of (1) asymptomatic, high-functioning hips without underlying hip pathology (controls); and (2) symptomatic, dysplastic hips that underwent periacetabular osteotomy (PAO). Thereby, we aimed to define CT-based thresholds for hip dysplasia and its subtypes. This is an IRB approved cross-sectional study of 51 high functioning, asymptomatic patients (102 hips) (Oxford Hip Score >43), without signs of osteoarthritis (Tönnis grade≤1), who underwent a CT scan of the pelvis (mean age: 52.1±5.5 years; 52.9% females); and 66 patients (72 hips) with symptomatic hip dysplasia treated with peri-acetabular osteotomy (PAO) (mean age: 29.3±7.3 years; 85.9% females). Anterior and posterior acetabular sector angles (AASA & PASA) were measured by two observers at three CT axial levels to determine equatorial, intermediate, and proximal ASA. Inter- and intra-observer reliability coefficient was high (between 0.882–0.992). Cut-off values for acetabular deficiency were determined based on Receiver Operating Characteristic (ROC) curve analysis, area under the curve (AUC) was calculated. The dysplastic group had significantly smaller ASAs compared to the Control Group, AUC was the highest at the proximal and intermediate PASA. Controls had a mean proximal PASA of 162°±17°, with a cut-off value for dysplasia of 137° (AUC: 0.908). At the intermediate level, the mean PASA of controls was 117°±11°, with a cut-off value of 107° (AUC 0.904). Cut-off for anterior dysplasia was 133° for proximal AASA (AUC 0.859) and 57° for equatorial AASA (AUC 0.868). Cut-off for posterior dysplasia was 102° for intermediate PASA (AUC 0.933). Measurement of ASA on CT is a reliable tool to identify dysplastic hips with high diagnostic accuracy. Posterior ASA less than 137° at the proximal level, and 107° at the intermediate level should alert clinicians of the presence of dysplasia


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 82 - 82
1 Dec 2022
Negm A Schneider S Vaile K Yee S Lienhard K Schneider P
Full Access

Guidelines for the use of preoperative blood tests for elective surgery were established. However, there is less evidence and no guidelines regarding using these tests when a young, healthy patient undergoes minor orthopaedic trauma surgery. Bloodwork is often ordered routinely, regardless of medical history or the nature of the injury. We hypothesized that unnecessary blood work is requested for younger pre-operative patients, and their results will not change peri-operative management. This practice is not a judicious use of healthcare resources. This study aimed to evaluate the frequency, type, cost, and impact on clinical decisions if standard preoperative bloodwork was completed in healthy patients requiring surgical management of a minor fracture or dislocation. After the approval of our institutional ethics board, a retrospective chart review was conducted. Inclusion criteria were patients aged 18-60 years, who had an isolated minor orthopaedic trauma requiring outpatient surgery, who were American Society of Anesthesiologists (ASA) class 1. ASA class 1 is defined as “a normal healthy patient, without any clinically important comorbidity and without a clinically significant past/present medical history.” Data records from January 1, 2016, to December 31, 2018, were extracted from a provincial database (the Analytics Data Integration, Measurement and Reporting) for five hospitals. Data including demographics, surgical treatment, type and number of blood tests ordered, and ordering physician were collected. Any abnormal test results were checked to see whether they led to a change in patient management or related to a postoperative adverse event. Independent samples t-tests and Chi-square tests were used to compare the characteristics of patients who had preoperative bloodwork versus those who did not. The cost of preoperative blood work was estimated. During these two years, 627 patients met inclusion criteria, and 27% (n=168) of these patients had bloodwork completed pre-operatively, while only 34% (n=57) of these had one or more abnormal laboratory parameters. These abnormalities were minor and did not alter clinical management or result in repeated bloodwork peri-operatively. Patients who had bloodwork were significantly older (40.2 years) compared with patients without preoperative blood work (37.8 years; p=0.03), but there was no difference in sex between those who had bloodwork (53.4% male) and those who did not (51.4% male; p=0.63). The most common blood test ordered was a complete blood count, and the most commonly abnormal result was a mildly elevated white blood cell count (19%; n= 29). The most common patients to receive bloodwork were those with ankle (34%) and distal radius (34%) fractures. The bloodwork was primarily ordered by clinical associates (26%; n=46) and emergency department physicians (22%; n=38). Without considering lab personnel, consumables, and analysis time, the cost of this bloodwork was approximately $7685, an average of $45 per patient. Pre-operative bloodwork in young, healthy, asymptomatic patients requiring outpatient surgery for minor orthopaedic trauma had no clinical significance and did not change patient management. Rigorous prospective research is warranted to establish national guidelines for appropriate pre-operative bloodwork ordering to minimize unnecessary and costly investigations


Full Access

Recent case reports have described V40 taper failure with clinically relevant adverse reaction to metal debris (ARMD). The real incidence of V40 taper damage and potential consequences are currently unclear, however. Aim of this study is therefore, to evaluate the long-term incidence of pseudotumors in a consecutive series of THA with V40 taper and identify potential influencing factors. From 2006 to 2007 a total number of 120 patients (127 hips) received either an uncemented (Accolade©) or cemented hip stem (ABGII©), both with V40 taper (Stryker© Mahwah, New Jersey, USA). They all were combined with 36 mm Vitallium (CoCrMo) heads and uncemented cups (Trident©) with XLPE inlays. 11,2 +/− 0,5 years post-op 82 patients with 87 hips (mean age 74 years, 58 % female) underwent clinical (PROMs) and radiographic evaluation. In 71 patients (75 hips) MARS- MRI of the hip was performed. 38 patients were lost to follow-up. In 81 patients (86 hips) chrome and cobalt levels were determined. MRI-investigation revealed 20 pseudotumors (26%) and 18 of them had a diameter of >2cm. Patients with pseudotumors had significant higher median cobalt ion levels compared to those without (2,85 μg/l vs. 1,32 μg/l; p=0,022) and a significant correlation between pseudotumors and cobalt levels was found. Radiographic osteolysis was associated with pseudotumors as well (p= 0,014). Neither approach, BMI, gender, age, type of stem, head length, inclination nor heterotope ossification showed a significant correlation to pseudotumor occurrence. Due to the high incidence of local ARMD in in asymptomatic patients with V40 taper and metal heads we recommend regular post-operative follow-up investigations including routine metal ion screening and consecutive MRI investigation upon elevation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 3 - 3
10 Feb 2023
Sundaram A Woods J Clifton L Alt V Clark R Carey Smith R
Full Access

Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany). At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both patients remain asymptomatic. 3 patients were readmitted for dislocations, 1 of whom had 5 dislocations within 3 weeks post-operatively and was immobilised in an abduction brace to address a lack of muscle tone and has not had a revision of their components. Utilising navigation with meticulous implant design and construction; augmented with an ultrathin plasma coating of silver particles embedded between layers of siloxane with controlled and long-term generation of silver ion diffusion has led to outstanding outcomes in this series of 12 custom acetabular and hemipelvis reconstructions. No patients were revised for infection and no patients show signs of failure of bone on growth and incorporation. Hip instability remains a problem in these challenging mechanical environments and we continue to reassess our approach to this multifaceted problem


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 11 - 11
1 Jun 2023
Doherty C McKee CM Foster A
Full Access

Introduction. Non-union is an unfortunate outcome of the fracture healing process for some patients; with an estimated annual incidence of 17.4- 18.9 per 100,00. The management of these patients depicts a significant clinical challenge for surgeons and financial burden to health services. External ultrasound stimulation devices (Exogen. TM. ) have been highlighted as a novel non invasive therapy to achieve union in cases of delayed and non-union. The aim of the current study was to assess the rate of union in patients using Exogen. TM. therapy for delayed fracture union in a district general hospital. Materials & Methods. This is a single centre retrospective continuous cohort study. Patients were identified from a prospective database of all patients prescribed Exogen. TM. therapy between June 2013- September 2021 in a district general hospital. Patient data was collected retrospectively using electronic patient records. Fracture union was assessed both clinically and radiographically and recorded in patient records. Failure of treatment was defined as progression to operative treatment due to lack of progression with ultrasound therapy or established asymptomatic non-union. Patient were excluded from the study if Exogen. TM. therapy was prescribed within 6 weeks of injury. Results. 142 potential patient were identified from the database. 35 patients were excluded from the data set (17 patients due to insufficient data available, 9 lost to follow up, 4 died and 5 excluded due to early application of Exogen. TM. therapy). 58 Patients progressed to union with an average time to union of 41 weeks. 49 cases failed to progress to union, of which 7 cases had conversion to operative management prior to completion of single course of Exogen. TM. therapy and were excluded from all other data review. 12% of cases that failed to unite with ultrasound therapy required multiple operations to establish union. Conclusions. A union rate of 58% was reported by the current study, which is lower than previously published. This likely reflects the heterogenous nature of the patient population and fracture distribution included. However, this is potentially a more reflective union rate for the general population than previously published. There were no adverse events associated with the use of Exogen. TM. therapy in the current study. Therefore supporting its use as a first line management to promote union in delayed fracture union in the general population. Additionally, failure to achieve fracture union with utilisation of Exogen. TM. therapy was associated with risk for requirement of multiple surgeries to achieve union. This could serve as an indicator for surgeon to consider the requirement additional measures at the initial surgical procedure


Bone & Joint Open
Vol. 1, Issue 6 | Pages 287 - 292
19 Jun 2020
Iliadis AD Eastwood DM Bayliss L Cooper M Gibson A Hargunani R Calder P

Introduction. In response to the COVID-19 pandemic, there was a rapidly implemented restructuring of UK healthcare services. The The Royal National Orthopaedic Hospital, Stanmore, became a central hub for the provision of trauma services for North Central/East London (NCEL) while providing a musculoskeletal tumour service for the south of England, the Midlands, and Wales and an urgent spinal service for London. This study reviews our paediatric practice over this period in order to share our experience and lessons learned. Our hospital admission pathways are described and the safety of surgical and interventional radiological procedures performed under general anaesthesia (GA) with regards to COVID-19 in a paediatric population are evaluated. Methods. All paediatric patients (≤ 16 years) treated in our institution during the six-week peak period of the pandemic were included. Prospective data for all paediatric trauma and urgent elective admissions and retrospective data for all sarcoma admissions were collected. Telephone interviews were conducted with all patients and families to assess COVID-19 related morbidity at 14 days post-discharge. Results. Overall, 100 children underwent surgery or interventional radiological procedures under GA between 20 March and 8 May 2020. There were 35 trauma cases, 20 urgent elective orthopaedic cases, two spinal emergency cases, 25 admissions for interventional radiology procedures, and 18 tumour cases. 78% of trauma cases were performed within 24 hours of referral. In the 97% who responded at two weeks following discharge, there were no cases of symptomatic COVID-19 in any patient or member of their households. Conclusion. Despite the extensive restructuring of services and the widespread concerns over the surgical and anaesthetic management of paediatric patients during this period, we treated 100 asymptomatic patients across different orthopaedic subspecialties without apparent COVID-19 or unexpected respiratory complications in the early postoperative period. The data provides assurance for health care professionals and families and informs the consenting process. Cite this article: Bone Joint Open 2020;1-6:287–292


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 57 - 57
1 Apr 2019
Borton Z Nicholls A Mumith A Pearce A Briant-Evans T Stranks G Britton J Griffiths J
Full Access

Aims. Metal-on-metal total hip replacements (MoM THRs) are frequently revised. However, there is a paucity of data on clinical outcomes following revision surgery in this cohort. We report on outcomes from the largest consecutive series of revisions from MoM THRs and consider pre-revision factors which were prognostic for functional outcome. Materials and Methods. A single-centre consecutive series of revisions from MoM THRs performed during 2006–2015 was identified through a prospectively maintained, purpose-built joint registry. The cohort was subsequently divided by the presence or absence of symptoms prior to revision. The primary outcome was functional outcome (Oxford Hip Score (OHS)). Secondary outcomes were complication data, pre- and post-revision serum metal ions and modified Oxford classification of pre-revision magnetic resonance imaging (MRI). In addition, the study data along with demographic data was interrogated for prognostic factors informing on post-revision functional outcome. Results. 180 revisions in 163 patients were identified at a median follow-up of 5.48 (2–11.7) years. There were 152 (84.4%) in the symptomatic subgroup and 28 (15.6%) in the asymptomatic group. Overall median OHS improved from 29 to 37 with revision (P<0.001). Symptomatic patients experienced greater functional benefit (DOHS 6.5 vs. 1.4, p=0.012) compared to asymptomatic patients, though they continued to report inferior outcomes (OHS 36.5 vs 43, p=0.004). The functional outcome of asymptomatic patients was unaffected by revision surgery (pre-revision OHS 41, post-revision OHS 43, p=0.4). Linear regression analysis confirmed use of a cobalt-chrome (CoCr)-containing bearing surface (MoM or metal-on- polyethylene) at revision and increasing BMI were predictive of poor functional outcome (R. 2. 0.032, p=0.0224 and R. 2. 0.039, p=0.015 respectively). Pre- and post-revision serum metal ions and pre-revision MRI findings were not predictive of outcome. The overall complication rate was 36% (n=65) with a re-revision rate of 6.7%. The most common complication was ongoing adverse reaction to metal debris (ARMD, defined as positive post-revision MRI) in 21.1%. The incidence of ongoing ARMD was not significantly different between those with CoCr reimplanted and those without (p=0.12). Conclusions. To our knowledge, our study represents the largest single-centre consecutive series of revision THRs from MoM bearings in the literature. Symptomatic patients experience the greatest functional benefit from revision surgery but do not regain the same level of function as patients who were asymptomatic prior to revision. The re-implantation of CoCr as a primary bearing surface and increasing BMI was associated with poorer functional outcome


Bone & Joint Research
Vol. 8, Issue 10 | Pages 451 - 458
1 Oct 2019
Kuroda Y Tanaka T Miyagawa T Kawai T Goto K Tanaka S Matsuda S Akiyama H

Objectives. Using a simple classification method, we aimed to estimate the collapse rate due to osteonecrosis of the femoral head (ONFH) in order to develop treatment guidelines for joint-preserving surgeries. Methods. We retrospectively analyzed 505 hips from 310 patients (141 men, 169 women; mean age 45.5 years . (sd. 14.9; 15 to 86)) diagnosed with ONFH and classified them using the Japanese Investigation Committee (JIC) classification. The JIC system includes four visualized types based on the location and size of osteonecrotic lesions on weightbearing surfaces (types A, B, C1, and C2) and the stage of ONFH. The collapse rate due to ONFH was calculated using Kaplan–Meier survival analysis, with radiological collapse/arthroplasty as endpoints. Results. Bilateral cases accounted for 390 hips, while unilateral cases accounted for 115. According to the JIC types, 21 hips were type A, 34 were type B, 173 were type C1, and 277 were type C2. At initial diagnosis, 238/505 hips (47.0%) had already collapsed. Further, the cumulative survival rate was analyzed in 212 precollapsed hips, and the two-year and five-year collapse rates were found to be 0% and 0%, 7.9% and 7.9%, 23.2% and 36.6%, and 57.8% and 84.8% for types A, B, C1, and C2, respectively. Conclusion. Type A ONFH needs no further treatment, but precollapse type C2 ONFH warrants immediate treatment with joint-preserving surgery. Considering the high collapse rate, our study results justify the importance of early diagnosis and intervention in asymptomatic patients with type C2 ONFH. Cite this article: Y. Kuroda, T. Tanaka, T. Miyagawa, T. Kawai, K. Goto, S. Tanaka, S. Matsuda, H. Akiyama. Classification of osteonecrosis of the femoral head: Who should have surgery?. Bone Joint Res 2019;8:451–458. DOI: 10.1302/2046-3758.810.BJR-2019-0022.R1


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 21 - 21
1 Jul 2020
Nandra R Ahmed U Berryman F Brash L Dunlop D Matharu G
Full Access

Introduction. Many worldwide regulatory authorities recommend regular surveillance of metal-on-metal hip arthroplasty patients given high failure rates. However concerns have been raised about whether such regular surveillance, which includes asymptomatic patients, is evidence-based and cost-effective. We determined: (1) the cost of implementing the 2015 MHRA surveillance in “at-risk” Birmingham Hip Resurfacing (BHR) patients, and (2) how many asymptomatic hips with adverse reactions to metal debris (ARMD) would have been missed if patients were not recalled. Methods. All BHR patients subject to the 2015 MHRA recall (all females, and males with head sizes 46mm or below, regardless of symptoms) at one specialist centre were invited for review (707 hips). All patients were investigated (Oxford Hip Score, radiographs, blood metal ions, and targeted cross-sectional imaging) and managed accordingly. Surveillance costs were calculated using finance department data, as was the number needed to treat (NNT) to avoid missing one case of asymptomatic ARMD. Results. The overall institutional surveillance cost to investigate all patients once was £105,922 (range £148 to £258 per patient). The most expensive aspects of surveillance were radiographs (£39,598), advanced nurse practitioner assistance (£23,618), cross-sectional imaging (£14,828), and blood metal ions (£14,825). 31 hips had imaging evidence of ARMD (12 revised, with 19 under surveillance). Seven hips were asymptomatic, however all revisions were symptomatic. The NNT to avoid missing one case of asymptomatic ARMD (on imaging and/or requiring revision) was 101 patients, equating to a screening cost of £18,041 to avoid one case of asymptomatic ARMD. Conclusions. Implementing MHRA surveillance for “at-risk” BHR patients was extremely costly, both financially and logistically. As the risk of asymptomatic ARMD was low, our data suggests the 2015 MHRA surveillance is not cost-effective. We therefore have concerns about the increasingly intensive surveillance recommended in the 2017 MHRA guidance for all metal-on-metal hip arthroplasty patients


Bone & Joint Open
Vol. 4, Issue 1 | Pages 3 - 12
4 Jan 2023
Hardwick-Morris M Twiggs J Miles B Al-Dirini RMA Taylor M Balakumar J Walter WL

Aims

Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation.

Methods

This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 20 - 20
1 Jul 2020
Beausejour M Parent S Dallaire P Thibeault F El-Hawary R Sanders J Yaszay B Akbarnia B Tohme P Roy-Beaudry M
Full Access

This study addresses a crucial gap in the knowledge of normative spinal growth in children. The objective of this study is to provide detailed and accurate 3D reference values for global and segmental spinal dimensions in healthy children under the age of 11. Radiographic spine examinations of healthy children conducted to rule out scoliosis were reviewed in four scoliosis referral centers in North America. All consecutive children aged three to eleven years old with EOS biplanar good quality x-rays, but without diagnosed growth-affecting pathologies, were included. Postero-Anterior and Lateral calibrated x-rays were used for spine 3D reconstruction and computation of vertebral body height and spine length. Median and interquartile range were calculated from cross-sectional data. Smooth centiles growth curves for 3D True Spinal Length (3DTSL) between T1 and S1, as well as for mid-vertebral heights of T5, T12 and L3, where fit and calibrated from data using the Lambda-Mu-Sigma method (GAMLSS package for R). This method automatically selects the best performing distribution from a familly of choices. Tables of centiles were then predicted from the computed models for selected ages. A total of 638 full spine examinations from asymptomatic patients were reconstructed in 3D, 397 in girls and 241 in boys. Medians and interquartile ranges were calculated for 3DTSL (T1-S1): 285 (24) mm, 314 (26) mm and 349 (31) mm, and for selected vertebral heights T5: 10 (1) mm, 11 (1) mm and 12 (1) mm, T12: 13 (2) mm, 14 (1) mm and 16 (2) mm, and L3: 14 (1) mm, 16 (2) mm and 18 (2) mm, respectively for the 3–6, 6–8 and 8–11 age groups. Centile curves ready for clinical use of the 3DTSL (T1-S1) and of the vertebral heights of T5, T12 and L3 as a function of age were derived for the 5, 10, 25, 50, 75, 90 and 95th centiles. In general, boys presented linear relationships between spinal dimensions and age, and girls presented more diverging trends with increased variance for older ages. Accordingly curves for boys follow the Normal distribution whereas those for girls follow the original Box-Cox-Cole-Green distribution. Model diagnostic tests (normally distributed residuals, adequate wormplots and |Z statistics| < 2) confirmed adequacy of the models and the absence of significant misfit. Accurate reference values were derived for spinal dimensions in healthy children. Spinal dimension charts showed that the spinal lengths and vertebral heights changed relatively constantly across the age groups closely resembling WHO total body height charts. The reference values will help physicians better assess their patients' growth potential. It could also be used to predict expected spinal dimensions at maturity or changes in pathologic conditions as well as to assess the impact of growth friendly interventions in the correction of spinal deformities


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 68 - 68
1 Jul 2020
Hall D Pourzal R Jacobs J Urban R
Full Access

Little is known about the relationship between head-neck corrosion and its effect on the periprosthetic tissues and distant organs of patients hosting well-functioning devices. The purpose of this study was to investigate in postmortem retrieved specimens the degree and type of taper damage, and the corresponding histologic responses in periprosthetic tissues and distant organs. Fifty postmortem THRs (34 primaries, 16 revisions) retrieved after 0.5 to 26 years were analyzed. Forty-three implants had a CoCrMo stem and seven had a Ti6Al4V stem. All heads were CoCrMo and articulated against polyethylene cups (19 XLPE, 31 UHMWPE). H&E sections of joint pseudocapsules, liver, spleen, kidneys and lymph nodes were graded 1–4 for the intensity of various inflammatory cell infiltrates and tissue characteristics. Corrosion damage of the taper surfaces was assessed using visual scoring and quantitated with an optical coordinate measuring machine. SEM analysis was used to determine the acting corrosion mode. Polyethylene wear was assessed optically. The majority of tapers had minimal to mild damage characterized by local plastic deformation of machining line peaks. Imprinting of the stem topography onto the head taper surface was observed in 18 cases. Column damage on the head taper surface occurred in three cases. All taper surfaces scored moderate or severe exhibited local damage features of fretting and/or pitting corrosion. Moderate or severe corrosion of the head and/or trunnion was present in nine hips. In one asymptomatic patient with bilateral hips, lymphocyte-dominated tissue reactions involving perivascular infiltrates of lymphocytes and plasmacytes were observed. In this patient, mild, focal lymphocytic infiltrates were also present in the liver and kidneys, and there was focal histiocytosis and necrosis of the para-aortic lymph nodes. These two implants, which had been in place for 58.6 and 60.1 months, had severe intergranular corrosion of the CoCrMo trunnion, and column damage and imprinting on the head taper. In the other 41 hips, macrophage responses in the joint pseudocapsule to metallic and/or polyethylene wear particles ranged widely from minimal to marked. Focal necrosis in the pseudocapsules of 12 arthroplasties was related to high concentrations of CoCrMo, TiAl4V, TiO, BaSO4 and polyethylene wear particles. High concentrations of these particles were also detected in para-aortic lymph nodes. Rare to mild macrophages were observed in liver and spleen. This is a comprehensive study of wear and corrosion within well-functioning postmortem retrieved THRs, and the resulting local and distant tissue reactions. One of eight patients with moderate or severe corrosion did have a subclinical inflammatory response dominated by lymphocytes after five years. To what extent such an inflammatory process might progress to become symptomatic is not known. Ionic and particulate products generated by corrosion disseminated systemically. The minor lymphocytic infiltrate in the liver and kidneys of one subject with bilateral severely corroded head-neck junctions might suggest possible metal toxicity. The diagnosis of adverse tissue reactions to corrosion of modular junctions can be challenging. Postmortem retrieval studies add to our understanding of the nature and progression of lymphocyte-dominated adverse local and potentially systemic tissue reactions to corrosion of modular junctions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 109 - 109
1 Sep 2012
Masri BA Williams DH Greidanus NV Duncan CP Garbuz DS
Full Access

Purpose. There is a postulated association between increased serum metal ions and pseudotumour formation in patients with metal-on-metal hip replacements. The primary aim of this study was to assess the prevalence of pseudotumour in 31 asymptomatic patients with a large femoral head (LFH) metal-on-metal hip implant. This was compared to the prevalence of pseudotumour in 20 matched asymptomatic patients with a hip resurfacing (HRA) and 24 matched asymptomatic patients with a standard metal-on-polyethylene (MOP) total hip. A secondary objective was to assess possible correlation between increased serum metal ions and pseudotumour formation. Method. Ultrasound examination of the three groups was performed at a minimum follow up of two years. Serum metal ions were measured in the metal-on-metal LFH and HRA groups at a minimum of two years. Results. There were 10 (32%) solid or cystic masses in the LFH group with a mean size of 89.3 (8 to 437) cm3. In the HRA group there were five (25%) masses with a mean size of 41.6 (6 to 119) cm3. In the MOP group there was one cystic mass measuring 9.8 cm3. Median serum cobalt and chromium ion levels in the LFH group were 4.50 gL (interquartile range, 2.38 to 7.47) and 2.82 gL (interquartile range, 1.48 to 3.18) compared to 0.83 gL (interquartile range, 0.65 to 1.12) and 1.08 gL (interquartile range, 0.78 to 1.31) in the HRA group. Conclusion. This study demonstrates a significantly higher prevalence of pseudotumours in patients with large head metal-on-metal total hips. The higher levels of metal ions in this group suggest that elevated metal ions may lead to pseudotumour formation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 23 - 23
1 Oct 2019
Lawrie CM Barrack TR Abu-Amer W Adelani MA Clohisy JC Barrack RL Nunley RM
Full Access

Introduction. The utility and yield of the current practice of routine screening of asymptomatic patients after primary total hip arthroplasty (THA) and total knee arthroplasty (TKA) is unclear. The purpose of this prospective survey study was to determine the utility of the routine on year follow up visit primary THA and TKA. Methods. We prospectively enrolled all patients undergoing primary THA and TKA. At one-year follow-up, patients were asked to complete a survey that asked about satisfaction with the and if they thought the visit was worthwhile. Surgeons also completed a survey which asked if any intervention was done, if any problems were diagnosed/avoided, and if the visit was worthwhile. Data was analyzed and compared between patients and surgeons, and was also compared to the need for any additional interventions. Results. Between October 2017 and June 2018, 512 patients underwent primary THA or TKA. Of these, passive one-year follow-up was obtained in 195 (38%). The final cohort consisted of 195 patients; 102 THAs and 94 TKAs with mean follow-up of 378 days (range, 276–480 days). Patients reported a mean 4.64 rating when asked if the visit was worthwhile (5-point scale, 1=not worthwhile, 5=very worthwhile). No interventions were performed or ordered at 56.3% of visits. Physicians reported that complications were avoided because of the visit at 23.03% of visits and 66.8% of visits were worthwhile (yes/no). 49.44% of visits where no intervention was ordered were rated as worthwhile, whereas 90.3% of visits with interventions ordered were rated as worthwhile. Conclusions. Patients generally thought that their follow up visit was worthwhile, even when no intervention was ordered or issue was addressed. In the visits without any interventions, over half of physicians thought the visit was not worthwhile. Surgeons may consider restricting their one year postoperative visits to symptomatic patients only. For any tables or figures, please contact the authors directly