Cobalt chrome alloy is commonly used in joint replacement surgery. However, it is recognised that some patients develop lymphocyte mediated delayed type hypersensitivity (DTH) responses to this material, which may result in extensive bone and soft tissue destruction. Phase 1. United Kingdom: From an existing database, we identified extreme phenotype patient groups following metal on metal (MoM) hip resurfacing or THR: ALVAL with low wearing prostheses; ALVAL with high wear; no ALVAL with high wear; and
Discoid meniscus (DM) is a congenital variant of the knee joint that involves morphological and structural deformation, with potential meniscal instability. The prevalence of the Discoid Lateral Meniscus (DLM) is higher among the Asians than among other races, and both knees are often involved. Meniscal pathology is widely prevalent in the adult population, secondary to acute trauma and chronic degeneration. The true prevalence in children remains unknown, as pathologies such as discoid menisci often go undiagnosed, or are only found incidentally. A torn or unstable discoid meniscus can present with symptoms of knee pain, a snapping or clicking sensation and/or a decrease in functional activity, although it is not known if a specific presentation is indicative of a torn DM. While simple radiographs may provide indirect signs of DLM, magnetic resonance imaging (MRI) and arthroscopy is essential for diagnosis and treatment planning.
Mechanical irritation or impingement of the iliopsoas tendon accounts for 2–6% of persistent postoperative pain cases after total hip arthroplasty (THA). The most common trigger is anterior cup overhang. CT-scan can be used to identify and measure this overhang; however, no threshold exists for symptomatic anterior iliopsoas impingement. We conducted a case–control study in which CT-scan was used to define a threshold that differentiates patients with iliopsoas impingement from
The periacetabular osteotomy(PAO) is an effective common hip-preserving procedure to treat symptomatic acetabular dysplasia of the hip (DDH). The literature regarding truly long-term patient outcomes after PAO remains limited. We sought to evaluate our patient cohort treated by PAO 25 to 33 years ago to identify factors positively and negatively associated with durable therapeutic success. 219 dysplastic hips (183 patients) underwent PAO between August 1991 and December 1999 by a single surgeon. 164 hips in 134 patients were retrospectively evaluated at minimum of 25 years and maximum of 33 years post-operatively. Hips were evaluated using the pain subscale of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) postoperatively. Osteotomy failure was defined as WOMAC pain score of >/=10 or the need for total hip arthroplasty (THA). 7 patients (7 hips) had died - none of whom had THR. 142/176 remaining patients were located. All patients returned questionnaires; some were seen in person with images. Of patients analyzed to date, 109 hips (63%) were asymptomatic/mildly symptomatic with a preserved hip. 58 hips (33%) had undergone THA. 7 preserved hips (5%) were symptomatic (WOMAC>10). Patients with THA were slightly older than
A concern of metal on metal hip resurfacing arthroplasty is long term exposure to Cobalt (Co) and Chromium (CR) wear debris from the bearing. This study compares whole blood metal ion levels from patients drawn at one-year following Birmingham Hip Resurfacing (BHR) to levels taken at a minimum 10-year follow-up. A retrospective chart review was conducted to identify all patients who underwent a BHR for osteoarthritis with a minimum 10-year follow-up. Whole blood metal ion levels were drawn at final follow-up in June 2019. These results were compared to values from patients with one-year metal ion levels. Of the 211 patients who received a BHR, 71 patients (54 males and 17 females) had long term metal ion levels assessed (mean follow-up 12.7 +/− 1.4 years). The mean Co and Cr levels for patients with unilateral BHRs (43 males and 13 females) were 3.12 ± 6.31 ug/L and 2.62 ± 2.69 ug/L, respectively, and 2.78 ± 1.02 ug/L and 1.83 ± 0.65 ug/L for patients with bilateral BHRs (11 males and 4 females). Thirty-five patients (27 male and 8 female) had metal-ion levels tested at one-year postoperatively. The mean changes in Co and Cr levels were 2.29 ug/l (p = 0.0919) and 0.57 (p = 0.1612), respectively, at one year compared to long-term. These changes were not statistically significant. This study reveals that whole blood metal ion levels do not change significantly when comparing one-year and ten-year Co and Cr levels. These ion levels appear to reach a steady state at one year. Our results also suggest that regular metal-ion testing as per current Medicines and Healthcare products Regulatory Agency (MHRA) guidelines may be impractical for
Abstract. Background. Post operative radiographs following total joint arthroplasty are requested as part of routine follow up in many institutions. These studies have a significant cost to the local departments, in terms of financial and clinic resources, however, previous research has suggested they may not alter the course of the patients treatment. The purpose of this study was to assess the significance of elective post operative radiographs on changes in management of patients who underwent total joint arthroplasty. Method. All patients who underwent total knee arthroplasty and total hip arthroplasty at a District General Hospital from 2019 to 2020 were included. Data was collected retrospectively from medical records and radiograph requests. Alterations to clinical management based on radiographic findings were reviewed in clinic letters. Results. A total of 227 Total joint arthroplasty were retrieved. With 111(49%) total hip arthroplasty and 116 (51%) total knee arthroplasty. 54 were excluded due to having no clinical follow up and 173 met inclusion criteria. 56 (32%) had their post operative elective radiograph, while 93 (53.8%) patients had none. There were no abnormalities detected from the elective radiographs and none of the patients returned to the theatre. 24 patients (13%) presented with symptoms and had non-elective radiographs, 16 (67%) did not have any interventions and 8 (4.6%) required intervention and were taken to theatre. Discussion: Not performing these radiographs saves time, cost, and prevents unnecessary radiation exposure. In our institution, a 2-view joint radiograph costs £29 and takes roughly 15 minutes. This does not include indirect costs of additional clinic time and patient waiting time. In the larger context, the cost associated with elective radiographs is significant and our data suggests that routine post-operative radiographs are not beneficial as part of standard post-operative protocol for
Traditional radiographic criteria might underestimate or fail to detect subtle types of acetabular dysplasia. Acetabular sector angles (ASA) can measure the degree of anterior and posterior coverage of the femoral head on computed tomography (CT). This study aims to determine ASA values at different axial levels in a cohort of (1) asymptomatic, high-functioning hips without underlying hip pathology (controls); and (2) symptomatic, dysplastic hips that underwent periacetabular osteotomy (PAO). Thereby, we aimed to define CT-based thresholds for hip dysplasia and its subtypes. This is an IRB approved cross-sectional study of 51 high functioning,
Guidelines for the use of preoperative blood tests for elective surgery were established. However, there is less evidence and no guidelines regarding using these tests when a young, healthy patient undergoes minor orthopaedic trauma surgery. Bloodwork is often ordered routinely, regardless of medical history or the nature of the injury. We hypothesized that unnecessary blood work is requested for younger pre-operative patients, and their results will not change peri-operative management. This practice is not a judicious use of healthcare resources. This study aimed to evaluate the frequency, type, cost, and impact on clinical decisions if standard preoperative bloodwork was completed in healthy patients requiring surgical management of a minor fracture or dislocation. After the approval of our institutional ethics board, a retrospective chart review was conducted. Inclusion criteria were patients aged 18-60 years, who had an isolated minor orthopaedic trauma requiring outpatient surgery, who were American Society of Anesthesiologists (ASA) class 1. ASA class 1 is defined as “a normal healthy patient, without any clinically important comorbidity and without a clinically significant past/present medical history.” Data records from January 1, 2016, to December 31, 2018, were extracted from a provincial database (the Analytics Data Integration, Measurement and Reporting) for five hospitals. Data including demographics, surgical treatment, type and number of blood tests ordered, and ordering physician were collected. Any abnormal test results were checked to see whether they led to a change in patient management or related to a postoperative adverse event. Independent samples t-tests and Chi-square tests were used to compare the characteristics of patients who had preoperative bloodwork versus those who did not. The cost of preoperative blood work was estimated. During these two years, 627 patients met inclusion criteria, and 27% (n=168) of these patients had bloodwork completed pre-operatively, while only 34% (n=57) of these had one or more abnormal laboratory parameters. These abnormalities were minor and did not alter clinical management or result in repeated bloodwork peri-operatively. Patients who had bloodwork were significantly older (40.2 years) compared with patients without preoperative blood work (37.8 years; p=0.03), but there was no difference in sex between those who had bloodwork (53.4% male) and those who did not (51.4% male; p=0.63). The most common blood test ordered was a complete blood count, and the most commonly abnormal result was a mildly elevated white blood cell count (19%; n= 29). The most common patients to receive bloodwork were those with ankle (34%) and distal radius (34%) fractures. The bloodwork was primarily ordered by clinical associates (26%; n=46) and emergency department physicians (22%; n=38). Without considering lab personnel, consumables, and analysis time, the cost of this bloodwork was approximately $7685, an average of $45 per patient. Pre-operative bloodwork in young, healthy,
Recent case reports have described V40 taper failure with clinically relevant adverse reaction to metal debris (ARMD). The real incidence of V40 taper damage and potential consequences are currently unclear, however. Aim of this study is therefore, to evaluate the long-term incidence of pseudotumors in a consecutive series of THA with V40 taper and identify potential influencing factors. From 2006 to 2007 a total number of 120 patients (127 hips) received either an uncemented (Accolade©) or cemented hip stem (ABGII©), both with V40 taper (Stryker© Mahwah, New Jersey, USA). They all were combined with 36 mm Vitallium (CoCrMo) heads and uncemented cups (Trident©) with XLPE inlays. 11,2 +/− 0,5 years post-op 82 patients with 87 hips (mean age 74 years, 58 % female) underwent clinical (PROMs) and radiographic evaluation. In 71 patients (75 hips) MARS- MRI of the hip was performed. 38 patients were lost to follow-up. In 81 patients (86 hips) chrome and cobalt levels were determined. MRI-investigation revealed 20 pseudotumors (26%) and 18 of them had a diameter of >2cm. Patients with pseudotumors had significant higher median cobalt ion levels compared to those without (2,85 μg/l vs. 1,32 μg/l; p=0,022) and a significant correlation between pseudotumors and cobalt levels was found. Radiographic osteolysis was associated with pseudotumors as well (p= 0,014). Neither approach, BMI, gender, age, type of stem, head length, inclination nor heterotope ossification showed a significant correlation to pseudotumor occurrence. Due to the high incidence of local ARMD in in
Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany). At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both
Introduction. Non-union is an unfortunate outcome of the fracture healing process for some patients; with an estimated annual incidence of 17.4- 18.9 per 100,00. The management of these patients depicts a significant clinical challenge for surgeons and financial burden to health services. External ultrasound stimulation devices (Exogen. TM. ) have been highlighted as a novel non invasive therapy to achieve union in cases of delayed and non-union. The aim of the current study was to assess the rate of union in patients using Exogen. TM. therapy for delayed fracture union in a district general hospital. Materials & Methods. This is a single centre retrospective continuous cohort study. Patients were identified from a prospective database of all patients prescribed Exogen. TM. therapy between June 2013- September 2021 in a district general hospital. Patient data was collected retrospectively using electronic patient records. Fracture union was assessed both clinically and radiographically and recorded in patient records. Failure of treatment was defined as progression to operative treatment due to lack of progression with ultrasound therapy or established
Introduction. In response to the COVID-19 pandemic, there was a rapidly implemented restructuring of UK healthcare services. The The Royal National Orthopaedic Hospital, Stanmore, became a central hub for the provision of trauma services for North Central/East London (NCEL) while providing a musculoskeletal tumour service for the south of England, the Midlands, and Wales and an urgent spinal service for London. This study reviews our paediatric practice over this period in order to share our experience and lessons learned. Our hospital admission pathways are described and the safety of surgical and interventional radiological procedures performed under general anaesthesia (GA) with regards to COVID-19 in a paediatric population are evaluated. Methods. All paediatric patients (≤ 16 years) treated in our institution during the six-week peak period of the pandemic were included. Prospective data for all paediatric trauma and urgent elective admissions and retrospective data for all sarcoma admissions were collected. Telephone interviews were conducted with all patients and families to assess COVID-19 related morbidity at 14 days post-discharge. Results. Overall, 100 children underwent surgery or interventional radiological procedures under GA between 20 March and 8 May 2020. There were 35 trauma cases, 20 urgent elective orthopaedic cases, two spinal emergency cases, 25 admissions for interventional radiology procedures, and 18 tumour cases. 78% of trauma cases were performed within 24 hours of referral. In the 97% who responded at two weeks following discharge, there were no cases of symptomatic COVID-19 in any patient or member of their households. Conclusion. Despite the extensive restructuring of services and the widespread concerns over the surgical and anaesthetic management of paediatric patients during this period, we treated 100
Aims. Metal-on-metal total hip replacements (MoM THRs) are frequently revised. However, there is a paucity of data on clinical outcomes following revision surgery in this cohort. We report on outcomes from the largest consecutive series of revisions from MoM THRs and consider pre-revision factors which were prognostic for functional outcome. Materials and Methods. A single-centre consecutive series of revisions from MoM THRs performed during 2006–2015 was identified through a prospectively maintained, purpose-built joint registry. The cohort was subsequently divided by the presence or absence of symptoms prior to revision. The primary outcome was functional outcome (Oxford Hip Score (OHS)). Secondary outcomes were complication data, pre- and post-revision serum metal ions and modified Oxford classification of pre-revision magnetic resonance imaging (MRI). In addition, the study data along with demographic data was interrogated for prognostic factors informing on post-revision functional outcome. Results. 180 revisions in 163 patients were identified at a median follow-up of 5.48 (2–11.7) years. There were 152 (84.4%) in the symptomatic subgroup and 28 (15.6%) in the asymptomatic group. Overall median OHS improved from 29 to 37 with revision (P<0.001). Symptomatic patients experienced greater functional benefit (DOHS 6.5 vs. 1.4, p=0.012) compared to
Objectives. Using a simple classification method, we aimed to estimate the collapse rate due to osteonecrosis of the femoral head (ONFH) in order to develop treatment guidelines for joint-preserving surgeries. Methods. We retrospectively analyzed 505 hips from 310 patients (141 men, 169 women; mean age 45.5 years . (sd. 14.9; 15 to 86)) diagnosed with ONFH and classified them using the Japanese Investigation Committee (JIC) classification. The JIC system includes four visualized types based on the location and size of osteonecrotic lesions on weightbearing surfaces (types A, B, C1, and C2) and the stage of ONFH. The collapse rate due to ONFH was calculated using Kaplan–Meier survival analysis, with radiological collapse/arthroplasty as endpoints. Results. Bilateral cases accounted for 390 hips, while unilateral cases accounted for 115. According to the JIC types, 21 hips were type A, 34 were type B, 173 were type C1, and 277 were type C2. At initial diagnosis, 238/505 hips (47.0%) had already collapsed. Further, the cumulative survival rate was analyzed in 212 precollapsed hips, and the two-year and five-year collapse rates were found to be 0% and 0%, 7.9% and 7.9%, 23.2% and 36.6%, and 57.8% and 84.8% for types A, B, C1, and C2, respectively. Conclusion. Type A ONFH needs no further treatment, but precollapse type C2 ONFH warrants immediate treatment with joint-preserving surgery. Considering the high collapse rate, our study results justify the importance of early diagnosis and intervention in
Introduction. Many worldwide regulatory authorities recommend regular surveillance of metal-on-metal hip arthroplasty patients given high failure rates. However concerns have been raised about whether such regular surveillance, which includes
Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC).Aims
Methods
This study addresses a crucial gap in the knowledge of normative spinal growth in children. The objective of this study is to provide detailed and accurate 3D reference values for global and segmental spinal dimensions in healthy children under the age of 11. Radiographic spine examinations of healthy children conducted to rule out scoliosis were reviewed in four scoliosis referral centers in North America. All consecutive children aged three to eleven years old with EOS biplanar good quality x-rays, but without diagnosed growth-affecting pathologies, were included. Postero-Anterior and Lateral calibrated x-rays were used for spine 3D reconstruction and computation of vertebral body height and spine length. Median and interquartile range were calculated from cross-sectional data. Smooth centiles growth curves for 3D True Spinal Length (3DTSL) between T1 and S1, as well as for mid-vertebral heights of T5, T12 and L3, where fit and calibrated from data using the Lambda-Mu-Sigma method (GAMLSS package for R). This method automatically selects the best performing distribution from a familly of choices. Tables of centiles were then predicted from the computed models for selected ages. A total of 638 full spine examinations from
Little is known about the relationship between head-neck corrosion and its effect on the periprosthetic tissues and distant organs of patients hosting well-functioning devices. The purpose of this study was to investigate in postmortem retrieved specimens the degree and type of taper damage, and the corresponding histologic responses in periprosthetic tissues and distant organs. Fifty postmortem THRs (34 primaries, 16 revisions) retrieved after 0.5 to 26 years were analyzed. Forty-three implants had a CoCrMo stem and seven had a Ti6Al4V stem. All heads were CoCrMo and articulated against polyethylene cups (19 XLPE, 31 UHMWPE). H&E sections of joint pseudocapsules, liver, spleen, kidneys and lymph nodes were graded 1–4 for the intensity of various inflammatory cell infiltrates and tissue characteristics. Corrosion damage of the taper surfaces was assessed using visual scoring and quantitated with an optical coordinate measuring machine. SEM analysis was used to determine the acting corrosion mode. Polyethylene wear was assessed optically. The majority of tapers had minimal to mild damage characterized by local plastic deformation of machining line peaks. Imprinting of the stem topography onto the head taper surface was observed in 18 cases. Column damage on the head taper surface occurred in three cases. All taper surfaces scored moderate or severe exhibited local damage features of fretting and/or pitting corrosion. Moderate or severe corrosion of the head and/or trunnion was present in nine hips. In one
Purpose. There is a postulated association between increased serum metal ions and pseudotumour formation in patients with metal-on-metal hip replacements. The primary aim of this study was to assess the prevalence of pseudotumour in 31
Introduction. The utility and yield of the current practice of routine screening of