Introduction. Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. However, there are few studies evaluating outcomes out to five years with a sufficient cohort. The purpose of this study was to evaluate implant survivorship and complications in revision TKAs with tibial cones. Methods. A retrospective review was completed from September 2006 through March 2018 evaluating 149 revision TKAs that received a tibial cone. The mean follow-up was 5.3 years. According to the AORI classification: 8% were 1, 18% were 2A, 55% were 2B, and 19% were 3. Results. Survival analysis at 6 years showed 96% free of revision for
Cementless fixation is an alternative to cemented unicompartmental knee replacement (UKR), with several advantages over cementation. This study reports on the 15-year survival and 10-year clinical outcomes of the cementless Oxford unicompartmental knee replacement (OUKR). This prospective study describes the clinical outcomes and survival of first 693 consecutive cementless medial OUKRs implanted in New Zealand. The sixteen-year survival was 89.2%, with forty-six knees being revised. The commonest reason for revision was progression of arthritis, which occurred in twenty-three knees, followed by primary dislocation of the bearing, which occurred in nine knees. There were two bearing dislocations secondary to trauma and a ruptured ACL, and two tibial plateau fractures. There were four revisions for polyethylene wear. There were four revisions for
Abstract. Background. Oxidized zirconium (OxZr) has been introduced as an alternative bearing for femoral components in Total Knee Arthroplasty (TKA). It has a ceramic-like zirconium oxide outer layer with a low coefficient of friction. Early studies have found OxZr TKA to have a low incidence of early failure in young high demand patients. Currently no study has reported on the outcome of these implants beyond ten years. Objectives. The purpose of our study was to present an in-depth 15-year survival analysis of cemented Profix II OxZr TKA. Study Design & Methods. Data was collected prospectively and survival analysis undertaken with multiple strict end points. Complication rates were recorded and patient reported outcomes were measured. Results. 617 Profix II OxZr TKAs were performed over four years. Forty-nine patients underwent reoperation.
Introduction. Recent total knee arthroplasty (TKA) designs have featured more anatomic morphologies and shorter tibial keels. However, several reports have raised concerns regarding the impact of these modifications on implant longevity. This study's purpose is to report the early performance of a modern, cemented TKA design. Methods. All patients who received a primary, cemented TKA from 2012 to 2017 with a minimum two-year follow-up were included. This implant features an asymmetric tibial baseplate and a shortened keel. Patient demographics, Knee Society Scores (KSS), and component alignment were recorded, and Kaplan-Meier survivorship analyses were performed. Results. 720 of 754 primary TKAs (95.5%) were included for analysis (mean follow-up: 3.9 ± 1.3 years; 562 cruciate-retaining, 158 posterior-stabilized). Eleven (1.5%) were revised for periprosthetic infection and seven (1.0%) for
Introduction. Tibial component loosening is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include isolated tibial component revision or full component revision. A full component revision is frequently selected by surgeons who are unfamiliar with the existing implant or have a “let's just start over attitude.” This option adds morbidity versus isolated tibial exchange. While isolated tibial exchange has lower morbidity, it is technically more challenging with regard to exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options. Methods. Patients revised for isolated
Background. Secondary osteonecrosis of the knee (SOK) generally occurs in relatively young patients in their working years; at advanced stages of SOK, the only viable surgical option is total knee arthroplasty (TKA). We conducted a retrospective study to investigate implant survivorship, clinical and radiographic outcomes, and complications of cemented TKA with/without patellar resurfacing for SOK. Methods. Thirty-eight cemented TKAs in 27 patients with non-traumatic SOK with a mean age 43 years (range 17–65) were retrospectively reviewed. Twenty-one patients (78%) were female. Mean body mass index was 31 kg/m. 2. (range 20–48); 11 patients (41%) received bilateral TKAs. Twenty patients (74%) had a history of corticosteroid use and 18% had a history of alcohol abuse. Patellar osteonecrosis was coincidentally found in six knees (16%), all of which had no anterior knee pain and had no patellofemoral joint collapse. The mean follow-up was 7 years (range 2–12). Knee Society Score (KSS) and radiographic outcomes were evaluated at 6 weeks, 1 year, then every 2–3 years thereafter. Results. Ninety-two percent had implant survivorship free from revision with significant improvement in KSS. Causes of revision included
Introduction. Metaphyseal fixation during revision total knee arthroplasties (TKAs) is important, but potentially challenging with historical cone designs. Material and manufacturing innovations have improved the size and shape of cones available, and simplified requisite bone preparation. In a very large series, we assessed implant survivorship, radiographic results, and clinical outcomes of new porous 3-D printed titanium metaphyseal cones featuring a reamer-based system. Methods. We reviewed 142 revision TKAs using 202 cones (134 tibial and 68 femoral) from 2015 to 2016. Sixty cases involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. Mean age was 66 years, with 54 % females. Mean BMI was 34 kg/m. 2. Patients had a mean of 2.4 prior surgeries and 48% had a history of periprosthetic infection. Mean follow-up was 2 years. Results. At 2 years, survivorship free of cone revision for aseptic loosening was 100% and free of cone revision for any reason was 98%. Survivorships free of any component revision and any reoperation were 90% and 83%. Five cones had been revised at latest follow-up: 3 for infection, 1 for periprosthetic fracture, and 1 for
Introduction. The causes of revision total knee replacement are varied. There is a subset of these revision cases (poly wear and some cases of instability for example) where the ability to retain the metal femoral and tibial components and replacing just the polyethylene is an appealing option. We report on a series of RTKR where only the poly insert was replaced and the patients were followed for a minimum of ten years. Materials and Methods. Our study group consisted of 64 consecutive non infected RTKR patients who underwent a revision of the polyethylene alone between 1998 and 2006. All patients had been treated originally with the same cemented, CR, patella resurfaced primary TKR. Reasons for revision were 51 poly wear and/or osteolysis, 7 instability, and 6 other. The average time from the primary to the revision surgery was 9.1 years (range 2.2 to 16.1 years). All patients had an isolated poly liner change. No femurs or tibial trays were revised. Average age of the cohort at revision was 72.2 (range 48 to 88). Average BMI was 31.9 (range 23.6 to 43.9). There were 36 female patients. Of the group, 42 were ASA 1 or 2 and 22 were ASA 3. Pre-op alignment averaged 6.0 (range 2 varus to 8 valgus). Patients were followed for a minimum of 10 years (range 10 to 19 years). Results. At final follow up 13 patients had died, none were lost to follow up leaving 51 patients available for review. There were 7 reoperations in 6 patients (7 knees). Reasons for reoperation were: 4
Purpose of Study. To identify the early functional outcomes, survivorship and complications associated with the Corin Uniglide Unicompartmental Knee Replacement (UKRs) from an independent centre. Methods and Results. A prospective consecutive case series of sixty Uniglide UKRs was carried out in fifty-one patients between January 2006 and March 2009. The data collected included:
. Primary outcome measures:. Pre- and post-operative American Knee Society Score (AKSS), Oxford Knee Scores (OKS), WOMAC. Survivorship. Secondary outcome measures:. X-ray error scores assessing component position. Complications. No cases were lost to follow-up. Mean follow-up time was 19 months (12 to 36months) and mean age was 66 years (39 to 78 years). Kaplan-Meier Survivorship showed 95% survival at 3 years (CI:6.4). All functional outcomes showed significant improvement p <0.05. There were two revisions within the first year, which were the main complications, secondary to
Introduction. Beneath infection, instability and malalignment,
A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits.Aims
Methods
The purpose of this study was to compare the clinical outcomes, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with or without hepatitis B virus (HBV) infection over at least ten years of follow-up. From January 2008 to December 2010, 266 TKAs were performed in 169 patients with HBV (HBV group). A total of 169 propensity score–matched patients without HBV were chosen for the control group in a one-to-one ratio. Then, the clinical outcomes, mortalities, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 11.7 years (10.5 to 13.4) in the HBV group and 11.8 years (11.5 to 12.4) in the control group.Aims
Methods
Distal femoral osteotomies (DFOs) are commonly used for the correction of valgus deformities and lateral compartment osteoarthritis. However, the impact of a DFO on subsequent total knee arthroplasty (TKA) function remains a subject of debate. Therefore, the purpose of this study was to determine the effect of a unilateral DFO on subsequent TKA function in patients with bilateral TKAs, using the contralateral knee as a self-matched control group. The inclusion criteria consisted of patients who underwent simultaneous or staged bilateral TKA after prior unilateral DFO between 1972 and 2023. The type of osteotomy performed, osteotomy hardware fixation, implanted TKA components, and revision rates were recorded. Postoperative outcomes including the Forgotten Joint Score-12 (FJS-12), Tegner Activity Scale score, and subjective knee preference were also obtained at final follow-up.Aims
Methods
The primary objective of this registry-based study was to compare patient-reported outcomes of cementless and cemented medial unicompartmental knee arthroplasty (UKA) during the first postoperative year. The secondary objective was to assess one- and three-year implant survival of both fixation techniques. We analyzed 10,862 cementless and 7,917 cemented UKA cases enrolled in the Dutch Arthroplasty Registry, operated between 2017 and 2021. Pre- to postoperative change in outcomes at six and 12 months’ follow-up were compared using mixed model analyses. Kaplan-Meier and Cox regression models were applied to quantify differences in implant survival. Adjustments were made for patient-specific variables and annual hospital volume.Aims
Methods
Varus-valgus constrained (VVC) devices are typically used in revision settings, often with stems to mitigate the risk of aseptic loosening. However, in at least one system, the VVC insert is compatible with the primary posterior-stabilized (PS) femoral component, which may be an option in complex primary situations. We sought to determine the implant survivorship, radiological and clinical outcomes, and complications when this VVC insert was coupled with a PS femur without stems in complex primary total knee arthroplasties (TKAs). Through our institution’s total joint registry, we identified 113 primary TKAs (103 patients) performed between 2007 and 2017 in which a VVC insert was coupled with a standard cemented PS femur without stems. Mean age was 68 years (SD 10), mean BMI was 32 kg/m2 (SD 7), and 59 patients (50%) were male. Mean follow-up was four years (2 to 10).Aims
Methods
Introduction. The precise indications for tibial component metal backing and modularity remain controversial in routine primary total knee arthroplasty. This is particularly true in elderly patients where the perceived benefits of metal backing such as load redistribution and the reduction of polyethylene strain may be clinically less relevant. The cost implications for choosing a metal-backed design over an all-polyethylene design may exceed USD500 per primary knee arthroplasty case. Methods. A prospective randomised clinical trial was carried out at the QEII Health Sciences Centre, Halifax, Nova Scotia, to compare modular metal-backed versus an all-polyethylene tibial component. Outcome measures included clinical range of motion, radiographs, survivorship, Knee Society Clinical Rating System, WOMAC and SF-12. Results. 116 patients requesting primary knee arthroplasty were recruited and randomised between the Smith & Nephew Genesis I non-modular (57) and modular (59) tibial designs between September 1995 and August 1997. At 10 years clinical follow-up, 4 implant revisions or intention-to-revise decisions were recorded in the metal-tray/modular group of which 2 were for
The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide. Registry data show good clinical outcome; however, concerns over the cement-tibial interface have been reported. We used retrieval analysis to give further insight into this controversial topic. We examined 12 titanium (Ti) PFC Sigma implants, eight cobalt-chromium (CoCr) PFC Sigma implants, eight cobalt-chromium PFC Sigma rotating platform (RP) implants, and 11 Attune implants. We used a peer-reviewed digital imaging method to quantify the amount of cement attached to the backside of each tibial tray. We then measured: 1) the size of tibial tray thickness, tray projections, peripheral lips, and undercuts; and 2) surface roughness (Ra) on the backside and keel of the trays. Statistical analyses were performed to investigate differences between the two designs.Objectives
Methods