header advert
Results 1 - 13 of 13
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 68 - 68
7 Aug 2023
Ball S Jones M Pinheiro VH Church S Williams A
Full Access

Abstract

Introduction

The aim of this study was to determine if elite athletes could return to professional sport after MCL or PLC reconstruction using LARS ligaments and to demonstrate the safety and efficacy of LARS by reporting sport longevity, subsequent surgeries and complications.

Methods

A retrospective review of all extra-articular knee ligament reconstructions in elite athletes utilising LARS ligaments by 3 knee surgeons between January 2013 and October 2020 was undertaken. Return to play (RTP) was defined as competing at professional level or national/ international level in amateur sport.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 73 - 73
7 Aug 2023
Shatrov J Jones M Ball S Williams A
Full Access

Abstract

Introduction

The aim of this study was to determine the factors affecting return to sport (RTS) and career longevity of elite athletes after microfracture of the knee.

Methods

A retrospective review of a consecutive series of elite athletes with chondral injuries in the knee treated with microfracture was undertaken. RTS was defined as competing in at least one event at professional level or national/ international level in amateur sport. Demographic, pre, intra and post operative factors affecting RTS were analysed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 65 - 65
7 Aug 2023
Jones M Pinheiro VH Balendra G Borque K Williams A
Full Access

Abstract

Introduction

The study aims were to demonstrate rates, level, and time taken to RTP in elite sports after ACL reconstruction (ACL-R) and compare football and rugby.

Methods

A retrospective review of a consecutive series of ACL-R between 2005 and 2019 was undertaken. Patients were included if they were elite athletes and were a minimum of 2 years post primary autograft ACL-R. The outcomes measured were return to play (RTP), (defined as participation in a professional match or in national/ international level amateur competition), time to RTP after surgery, and RTP level (Tegner score).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 76 - 76
7 Aug 2023
Borque K Han S Gold J Sij E Laughlin M Amis A Williams A Noble P Lowe W
Full Access

Abstract

Introduction

Persistent medial laxity increases the risk of failure for ACL reconstruction. To address this, multiple reconstruction techniques have been created. To date, no single strand reconstruction constructs have been able to restore both valgus and rotational stability. In response to this, a novel single strand Short Isometric Construct (SIC) MCL reconstruction was developed.

Methods

Eight fresh-frozen cadaveric specimens were tested in three states: 1) intact 2) after sMCL and dMCL transection, and 3) after SIC MCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 90N anterior drawer, 5Nm tibial external rotation torque, 8Nm valgus torque, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 77 - 77
7 Aug 2023
Borque K Han S Gold J Sij E Laughlin M Amis A Williams A Noble P Lowe W
Full Access

Abstract

Introduction

Historic MCL reconstruction techniques focused on the superficial MCL to restore valgus stability while overlooking tibial external rotation and the deep MCL. This study assessed the ability of a contemporary medial collateral ligament (MCL) reconstruction and a deep MCL (dMCL) reconstruction to restore rotational and valgus knee stability.

Methods

Six pairs fresh-frozen cadaveric knee specimens with intact soft tissue were tested in four states: 1) intact 2) after sMCL and dMCL sectioning, 3) contemporary MCL reconstruction (LaPrade et al), and 4) dMCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 8Nm valgus torque, 5Nm tibial external rotation torque, 90N anterior drawer, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 67 - 67
7 Aug 2023
Jones M Pinheiro VH Laughlin M Bourque K Williams A
Full Access

Abstract

Introduction

The aim of this study was to determine which factors affect a professional footballer's return to play performance level after ACL reconstruction (ACL-R). Additionally, to report their playing performance at 2 and 5 years post ACL-R compared to their preinjury performance.

Methods

A retrospective review of a consecutive series of primary ACL-R undertaken in professional footballers between 2005 and 2019 was undertaken. Performance was determined by the number of minutes played and the league level compared to their pre-injury baseline. Playing time (minutes) was classified as same (within 20%), more, or less playing time for each season compared to the one year prior to surgery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 70 - 70
7 Aug 2023
Bartolin PB Shatrov J Ball SV Holthof SR Williams A Amis AA
Full Access

Abstract

Introduction

Previous research has shown that, notwithstanding ligament healing, properly selected MCL reconstruction can restore normal knee stability after MCL rupture. The hypothesis of this work was that it is possible to restore knee stability (particularly valgus and AMRI) with simplified and/or less-invasive MCL reconstruction methods.

Methods

Nine unpaired human knees were cleaned of skin and fat, then digitization screws and optical trackers were attached to the femur and tibia. A Polaris stereo camera measured knee kinematics across 0o-100o flexion when the knee was unloaded then with 90N anterior-posterior force, 9Nm varus-valgus moment, 5Nm internal-external rotation, and external+anterior (AMRI) loading. The test was conducted for the following knee conditions: intact, injured: transected superficial and deep MCL (sMCL and dMCL), and five reconstructions: (long sMCL, long sMCL+dMCL, dMCL, short sMCL+dMCL, short sMCL), all based on the medial epicondyle isometric point and using 8mm tape as a graft, with long sMCL 60mm below the joint line (anatomical), short sMCL 30mm, dMCL 10mm (anatomical).


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 47 - 47
1 Jul 2022
Miyaji N Holthof S Willinger L Athwal K Ball S Williams A Amis A
Full Access

Abstract

Introduction

MCL injuries often occur concurrently with ACL rupture – most noncontact ACL injuries occur in valgus and external rotation (ER) - and conservative MCL treatment leads to increased rate of ACL reconstruction failure. There has been little work developing effective MCL reconstructions.

Methods

Cadaveric work measured MCL attachments by digitisation and radiographically, relating them to anatomical landmarks. The isometry of the superficial and deep MCL (sMCL and dMCL) and posterior oblique ligament (POL) was measured using fine sutures led to displacement transducers. Contributions to stability (restraint) were measured in a robotic testing system. Two MCL reconstructions were designed and tested: 3-strand reconstruction (sMCL+dMCL+POL), and 2-strand method (sMCL+dMCL) addressing anteromedial rotatory instability (AMRI). The resulting stability was measured in a kinematics test rig, and compared to the ‘anatomic’ sMCL+POL reconstruction of LaPrade.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 76 - 76
1 Jul 2022
Borque K Jones M Laughlin M Webster E Williams A
Full Access

Abstract

Introduction

The popularity of all-inside meniscal repair devices has led to a shift away from inside-out meniscus repair without comparative studies to support the change. The aim of this study was to compare the failure rate and time to failure of all-inside and inside-out meniscus repair performed in elite athletes.

Methodology

A retrospective review was performed of all elite athletes who underwent meniscal repair, with a minimum of two-year follow-up between 2013 and 2019. Repairs were classified as all-inside or inside-out according to the repair technique. Failure was defined as undergoing a subsequent surgery to address a persistent meniscal tear.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 78 - 78
1 Jul 2022
Borque K Jones M Balendra G Laughlin M Willinger L Williams A
Full Access

Abstract

Introduction

Anterolateral procedures can reduce the risk of re-rupture after ACL reconstruction in high risk patients however, this effectiveness has never been evaluated in elite athletes. The purpose of this study was to evaluate the effectiveness of lateral extra-articular tenodesis in reducing revision rates in ACL reconstructions in elite athletes.

Methodology

A consecutive cohort of elite athletes between 2005 and 2018 undergoing ACLR reconstruction with or without modified Lemaire lateral extra-articular tenodesis were analysed. A minimum of 2 years of follow-up was required. The association between the use of LET and ACL graft failure was evaluated with univariate and multivariate logistic regression models.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 60 - 60
1 Jul 2022
Williams A Zhu M Lee D
Full Access

Abstract

Background

Performing lateral extra-articular tenodesis (LET) with ACL reconstruction may conflict with the ACLR femoral tunnel.

Methods

12 fresh-frozen cadaveric knees were used: at 120 flexion, an 8mm ACLR femoral tunnel was drilled in the anteromedial bundle position via the anteromedial portal. A modified Lemaire LET was performed using a 1 cm-wide iliotibial band strip left attached to Gerdy's tubercle. The LET femoral fixation point was identified 10mm proximal / 5 mm posterior to the LCL femoral attachment, and a 2.4-mm guide wire was drilled, aiming at 0, 10, 20, or 30 degrees anteriorly in the axial plane, and at 0, 10, or 20 degrees proximally in the coronal plane. The relationship between the LET drilling guide wire and the ACLR femoral tunnel reamer was recorded for each combination. When collision with the femoral tunnel was recorded, the LET wire depth was measured.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 61 - 61
1 Jul 2022
Wang D Willinger L Athwal K Williams A Amis A
Full Access

Abstract

Background

Little scientific evidence is available regarding the effect of knee joint line obliquity (JLO).

Methods

10 fresh-frozen human cadaveric knees were axially loaded to 1500 N in a materials testing machine with the joint line tilted 0, 4, 8, and 12 degrees varus and valgus, at 0, and 20 degrees of knee flexion. The mechanical compression axis was aligned to the centre of the tibial plateau. Contact pressures / areas were recorded by sensors inserted between the tibia and femur below the menisci. Changes in relative femoral and tibial position in the coronal plane were obtained by an optical tracking system.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 80 - 80
1 Jul 2022
Pinheiro VH Jones M Borque K Balendra G White N Ball S Williams A
Full Access

Abstract

Introduction

Elite athletes sustaining a graft re-rupture after ACL reconstruction (ACL-R) undergo revision reconstruction to enable their return to elite sport. The aim of this study was to determine the rate of return to play (RTP) and competition levels at 2 and 5 years post revision ACL-R.

Methodology

A consecutive series of revision ACL-R in elite athletes undertaken by the senior author between 2009 and 2019 was retrospectively reviewed. Outcome measures were RTP rates and competition level.