Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 39 - 39
1 May 2019
Ewen A Deep K Jeldi A Leonard H
Full Access

Introduction

Body mass index (BMI) is a topical area of interest in the field of lower limb arthroplasty. It has been well established that BMI can influence post-operative outcomes. This study compares post-operative outcomes, including satisfaction rates, length of stay (LOS) and radiographic findings in different BMI groups following total hip arthroplasty (THA).

Methods

We retrospectively evaluated all non-navigated THAs performed at our institution from 2006–2016. Case-notes were reviewed for dichotomised satisfaction score, LOS and radiographic parameters including inclination, anteversion, limb length discrepancy (LLD) and offset discrepancy. Patients were classified into 4 groupings based on BMI (underweight (<24.5), healthy (24.5–30), obese (30–40), severely obese (>40)). Appropriate statistical analyses were performed to identify between group differences.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 68 - 68
1 Dec 2017
Deep K Picard F Shankar S Ewen A
Full Access

Background

The literature quotes up to 20% dissatisfaction rates for total knee replacements (TKR). Swedish registry and national joint registry of England and Wales confirm this with high volumes of patients included. This dissatisfaction rate is used as a basis for improving/changing/modernising knee implant designs by major companies across the world.

Aim

We aimed to compare post TKR satisfaction rates for navigated and non navigated knees.


Bone & Joint Research
Vol. 4, Issue 1 | Pages 6 - 10
1 Jan 2015
Goudie ST Deakin AH Deep K

Objectives

Acetabular component orientation in total hip arthroplasty (THA) influences results. Intra-operatively, the natural arthritic acetabulum is often used as a reference to position the acetabular component. Detailed information regarding its orientation is therefore essential. The aim of this study was to identify the acetabular inclination and anteversion in arthritic hips.

Methods

Acetabular inclination and anteversion in 65 symptomatic arthritic hips requiring THA were measured using a computer navigation system. All patients were Caucasian with primary osteoarthritis (29 men, 36 women). The mean age was 68 years (SD 8). Mean inclination was 50.5° (SD 7.8) in men and 52.1° (SD 6.7) in women. Mean anteversion was 8.3° (SD 8.7) in men and 14.4° (SD 11.6) in women.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 19 - 19
1 Dec 2014
Khan H Goudie S Deep K
Full Access

Introduction:

Restoration of normal hip biomechanics is vital for success of total hip arthroplasty (THA). This requires accurate placement of implants and restoration of limb length and offset. The purpose of this study was to assess the accuracy of computer navigation system in predicting cup placement and restoring limb length and offset.

Material and Methods:

An analysis of 259 consecutive patients who had THA performed with imageless computer navigation system was carried out. Acetabular cup abduction and anteversion, medialisation or lateralisation of offset and limb length change were compared between navigation measurements and follow-up radiographs. Sensitivity, specificity, accuracy and PPV were calculated to assess navigation for cup orientation and student t-test used for evaluation of offset and limb length change.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 46 - 46
1 Oct 2014
Deep K Siramanakul C Mahajan V
Full Access

The problem associated with ceramic on ceramic total hip replacement (THR) is audible noise. Squeaking is the most frequently documented sound. The incidence of squeaking has been reported to wide range from 0.7 to 20.9%. Nevertheless there is no study to investigate on incidence of noise in computer assisted THR with ceramic on ceramic bearing. The purpose of this study was to determine the incidence and risks factors associated with noise. We retrospectively reviewed 200 patients (202 hips) whom performed computer assisted THR (Orthopilot, B. Braun, Tuttlingen, Germany) with ceramic on ceramic bearing between March 2009 and August 2012. All procedures underwent uncemented THR with posterior approach by single surgeon. All hips implanted with PLASMACUP and EXIA femoral stem (B. Braun, Tuttlingen, Germany). All cases used BIOLOX DELTA (Ceramtec, AG, Plochingen, Germany) ceramic liner and head. The incidence and type of noise were interviewed by telephone using set of questionnaire. Patient's age, weight, height, body mass index, acetabular cup size, femoral offset size determined from medical record for comparing between silent hips and noisy hips. The acetabular inclination angle, acetabular anteversion angle, femoral offset, hip offset were reviewed to compare difference between silent hips and noisy hips. The audible noise was reported for 13 hips (6.44%). 5 patients (5 hips) reported click (2.47%) and 8 patients (8 hips) squeaked (3.97%). The mean time to first occurrence of click was 13.4 months and squeak was 7.4 months after surgery. Most common frequency of click was less than weekly (60%) and squeak was 1–4 times per week (50%). Most common activity associated with noise was bending; 40% in click and 75% in squeaking. No patients complained for pain or social problem. Moreover, no patient underwent any intervention for the noise. The noise had not self-resolved in any of the patients at last follow up. Age, weight, height and BMI showed no statistically significant difference between silent hips and click hips. In addition, there was also same result between silent hips and squeaking hips. Acetabular cup insert size and femoral offset stem size the results showed that there was no statistically significant difference between silent hips and click hips, also with squeaking hips. Acetabular inclination, angle acetabular anteversion angle, femoral offset, hip offset the results shown that only acetabular anteversion angle differed significantly between silent hips (19.94±7.78 degree) and squeaking hips (13.46±5.54 degree).

The results can conclude that incidence of noise after ceramic on ceramic THR with navigation was 6.44 %. Squeaking incidence was 3.97% and click incidence was 2.47%. The only associated squeaking risk factor was cup anteversion angle. In this study, squeaking hip had cup anteversion angle significant less than silent hip.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 6 - 6
1 Apr 2014
Johnstone C Fogg Q Deep K
Full Access

Introduction:

The transverse acetabular ligament (TAL) antomy is not a well explored aspect of the hip joint with limited morphological description in the reviewed literature. It is often used as an anatomical landmark for orientation of the acetabular component in total hip arthroplasty (THA). There is debate as to whether it represents an appropriate guide to cup placement in THA. Present descriptions in orthopaedic literature conside it as a single plane structure to which the surgeon can align the cup. The aim of the current study was to investigate the morphology of the TAL and it was hypothesised that the current description of it being a plane would prove insufficient.

Materials and methods:

Seven dry bone hemi-pelves were reconstructed using a microscribe and rhinoceros 4.0 3D software to visualise attachment sites. Three hips from two female donors were dissected to expose the acetabulum and the TAL. This structure was removed and a footprint taken of its perimeter and attachment sites for measurement of ligament length, breadth and area of attachment from digital photographs. Finally, 3D models of the dissected acetabuli with an outline of the TAL and attachment sites were created as before.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 46 - 46
1 Aug 2013
Khan M Jilani L Deep K
Full Access

Introduction

Malalignment of lower limb is a common feature in patients with osteoarthritis (OA). This, either cause or effect of OA, is known to alter the normal anatomy of knee and affects progression of wear and tear in mechanically stressed compartment. We investigated the relationship of mechanical axis to wear and tear in varus, neutral and valgus knees.

Materials and Methods

A retrospective analysis of 136 consecutive patients, with OA, who underwent total knee replacement using computer navigation. The thickness of medial and lateral cuts of distal femur and proximal tibia were recorded. Pre-op coronal deformity was assessed using long leg radiographs and Femoral Tibial Mechanical Angle (FTMA) calculated. Patients were evaluated as one group and three subgroups based on preop varus, neutral or valgus lower limb alignment. Student t test and Pearson's correlation coefficient were used for statistical analysis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 80 - 80
1 Aug 2013
Sankar B Venkataraman R Changulani M Sapare S Deep K Picard F
Full Access

In arthritic knees with severe valgus deformity Total Knee Arthroplasty (TKA) can be performed through medial or lateral parapatellar approaches. Many orthopaedic surgeons are apprehensive of using the lateral parapatellar approach due to lack of familiarity and concerns about complications related to soft tissue coverage and vascularity of the patella and the overlying skin. However surgeons who use this approach report good outcomes and no added complications. The purpose of our study was to compare outcomes following TKA performed through a medial parapatellar approach with those performed through a lateral parapatellar approach in arthritic knees with severe valgus deformity.

We conducted a retrospective review of patients from two consultants using computer navigation for all their TKAs. All patients with severe valgus deformities (Ranawat 2 & 3 grades) operated on between January 2005 and December 2011 were included. 66 patients with 67 TKAs fulfilled the inclusion criteria. Patients were group by approach; Medial = 34TKAs (34 patients) or Lateral = 33 TKAs (32 patients). Details were collected from patients' records, AP hip-knee-ankle (HKA) radiographs and computer navigation files. Outcome measures included lateral release rates, post-operative range of knee movements, long leg mechanical alignment measurements, post-operative Oxford scores at six weeks and one year, patient satisfaction and any complications. Comparisons were made between groups using t-tests.

The total cohort had a mean age of 69 years [42–82] and mean BMI of 29 [19–46]. The two groups had comparable pre-operative Oxford scores (Medial 41[27–56], Lateral 44 [31–60]) and pre-operative valgus deformity measured on HKA radiographs (Medial 13° [10°–27.6°], Lateral 12° [6°–22°]). Three patients in the Medial group underwent intra-operative lateral patellar release to improve patellar tracking. Seven patients in the Lateral group had a lateral condyle osteotomy for soft tissue balancing (one bilateral). There was no statistically significant difference between groups at one year follow up for maximum flexion (Medial 100° [78°–122°], Lateral 100° [85°–125°], p=0.42), fixed flexion deformity (Medial 1.2° [0°–10°], Lateral 0.9° [0°–10°], p=0.31) or Oxford score (Medial 23 [12–37], Lateral 23 [16–41], p=0.49). Similarly there was no difference in the patient satisfaction rates between the two groups at one year follow up. However there was a statistically significant difference in the mean radiographic post-operative alignment angle measurement (Medial 1.8° valgus [4° varus to 10° valgus], Lateral 0.3° valgus [5° varus to 7° valgus], p=0.02). One patient in the Medial group had a revision to hinged knee prosthesis for post-operative instability. There was no wound breakdown or patellar avascular necrosis noted in either of the groups.

The lateral parapatellar approach resulted in slightly better valgus correction on radiographs taken six weeks post-operatively. We found no major complications in the Lateral parapatellar approach group. Specifically we did not encounter any difficulties in closing the deep soft tissue envelope around the knee and there were no cases of patellar avascular necrosis or skin necrosis. Hence we conclude that lateral parapatellar approach is a safe and reliable alternative to the medial parapatellar approach for correction of severe valgus deformity in TKA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 29 - 29
1 Aug 2013
Duffy S Deep K Goudie S Freer I Deakin A Payne A
Full Access

This study measured the three bony axes usually used for femoral component rotation in total knee arthroplasty and compared the accuracy and repeatability of different measurement techniques.

Fresh cadaveric limbs (n=6) were used. Three observers (student, trainee and consultant) identified the posterior condylar (PCA), anteroposterior (AP) and the transepicondylar (TEA) axes, using a computer navigation system to record measurements. The AP axis was measured before and after being identified with an ink line. The TEA was measured by palpation of the epicondyles both before and after an incision was made in the medial and lateral gutters at the level of the epicondyles, allowing the index finger to be passed behind the gutters. In addition the true TEA was identified after dissection of all the soft tissues. Each measurement was repeated three times. For all axes and each observer the repeatability coefficient was calculated.

The identification of the PCA was the most reliable (repeatability coefficient: 1.1°) followed by the AP after drawing the ink line (4.5°) then the AP before (5.7°) and lastly the TEA (12.3°) which showed no improvement with the incisions (13.0°). In general the inter-observer variability for each axis was small (average 3.3°, range 0.4° to 6°), being best for the consultant and worst for the student. In comparison to the true TEA, the recorded TEA and AP axis averaged within 1.5° whilst the PCA was consistently 2.8° or more internally rotated.

This study echoed previous studies in demonstrating that palpating the PCA intra-operatively is highly precise but was prone to errors in representing the true TEA if there was asymmetrical condylar erosion. The TEA was highly variable irrespective of observer ability and experience. The line perpendicular line to the AP axis most closely paralleled the true TEA when measured after being identified with an ink line.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 45 - 45
1 Aug 2013
Sankar B Deep K Changulani M Khan S Atiya S Deakin A
Full Access

INTRODUCTION

Leg length discrepancy following total hip arthroplasty (THA) can be functionally disabling for affected patients and can lead on to litigation issues. Assessment of limb length discrepancy during THA using traditional methods has been shown to produce inconsistent results. The aim of our study was to compare the accuracy of navigated vs. non navigated techniques in limb length restoration in THA.

METHODS

A dataset of 160 consecutive THAs performed by a single surgeon was included. 103 were performed with computer navigation and 57 were non navigated. We calculated limb length discrepancy from pre and post op radiographs. We retrieved the intra-operative computer generated limb length alteration data pertaining to the navigated group. We used independent sample t test and descriptive statistics to analyse the data.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 47 - 47
1 Aug 2013
Deep K Khan M Goudie S
Full Access

Introduction

Restoration of normal hip biomechanics is vital for success of total hip arthroplasty (THA). This requires accurate placement of implants and restoration of limb length and offset. The purpose of this study was to assess the precision and accuracy of computer navigation system in predicting cup placement and restoring limb length and offset.

Material and Methods

An analysis of 259 consecutive patients who had THA performed with imageless computer navigation system was carried out. All surgeries were done by single surgeon (KD) using similar technique. Acetabular cup abduction and anteversion, medialisation or lateralisation of offset and limb length change were compared between navigation measurements and follow-up radiographs. Precision, accuracy, sensitivity and specificity were calculated to assess navigation for cup orientation and student t-test used for evaluation of offset and limb length change. A p value of <0.05 was considered significant for evaluation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 48 - 48
1 Aug 2013
Deep K
Full Access

Introduction

Malalignment of cup in total hip replacement (THR) increases rates of dislocation, impingement, acetabular migration, pelvic osteolysis, leg length discrepancy and polyethylene wear. Many surgeons orientate the cup in the same anteversion and inclination as the inherent anatomy of the acetabulum. The transverse acetabular ligament (TAL) and acetabular rim can be used as a reference. No study has yet defined the exact orientation of the TAL. The aim of this study was to describe the orientation of acetabular margin and compare it with TAL orientation.

Materials and Methods

Sixty eight hips with osteoarthritis undergoing THR with computer navigation were investigated. Anterior pelvic plane was registered using anterior superior iliac spines and pubic symphysis. Orientation of the natural acetabulum as defined by the acetabular rim with any osteophytes excised was measured. Since TAL is a rectangular band like structure, three recordings were done for each corresponding to the outer middle and inner margin of the band. All the readings were given by software as radiological anteversion and inclination.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_20 | Pages 21 - 21
1 Apr 2013
Deep K Duffy S Freer I Goudie S Nalwad H Deakin A Payne A
Full Access

Introduction

Soft tissue balancing is an important aspect of total knee replacement surgery. Traditionally sequential medial soft tissue release is performed for balancing in varus deformity. Its effects on kinematics and dynamic Femoro-Tibial-Mechanical-Angle (FTMA) have been described in extension and 90° flexion in coronal plane. However most studies have missed what happens when the knee flexes from 0 to 90 degrees This study is one of the first to describe its effects on knee kinematics throughout flexion. The aim was to look at deviation of FTMA in coronal plane with traditional sequential medial release with and without measured stress applied in varus and valgus at each point of measurement through the range of flexion.

Methods

12 cadaveric knees were studied using a computer navigation system. Rigid bodies were fixed to femur and tibia. The knee was exposed as per doing TKR surgery with medial parapatellar approach with no disturbance to the collateral ligaments. The anatomy was registered using a infra red waves based passive tracker navigation system. FTMA was studied in extension, 0°, 5°, 30°,45°,60°,90° and maximum flexion. Sequential medial release was performed in 7 steps as described by Luring et al. The sequential steps were Step 1: 2 cm release (antero medial tibial sleeve), Step 2: Postero-medial release, Step 3: 4 cm medial sleeve release, Step 4: 6 cm medial sleeve release, Step 5: Deep medial collateral ligament, Step 6: posterior cruciate ligament (PCL) medial half only, Step 7: entire PCL.

At each step FTMA was measured with and without stressing at each point of flexion. A 10 Newton Meter moment arm was applied for varus and valgus stress force.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 15 - 15
1 Apr 2013
Nalwad H Goudie S Deep K
Full Access

Introduction

Success of total hip replacement (THR) is closely linked to positioning of the acetabular component. Malalignment increases complication rates. Our aim was to describe the anteversion and inclination of the inherent acetabulum in arthritic hips and identify the number that fall out with the ‘safe zone’ of acetabular position described by Lewinnek et al. (anteversion 15±10 degrees; inclination 40±10 degrees).

Materials/Methods

A series of 65 hips undergoing non-image based computer navigated THR for Osteoarthritis were investigated. Anteversion and inclination was measured with the help of cup trials fixed with computer trackers aligned in orientation of the natural acetabulum. The acetabular inclination in all hips was measured on pre-operative digital radiographs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_20 | Pages 13 - 13
1 Apr 2013
Goudie S Deep K Picard F
Full Access

Introduction

The success of total hip replacement (THR) is closely linked to the positioning of the acetabular component. Malalignment increases rates of dislocation, impingement, acetabular migration, pelvic osteolysis, leg length discrepancy and polyethylene wear. Many surgeons orientate the cup to inherent anatomy of the acetabulum. Detailed understanding of the anatomy and orientation of the acetabulum in arthritic hips is therefore very important. The aim of this study was to describe the anteversion and inclination of the inherent acetabulum in arthritic hips and to identify the number that fall out with the ‘safe zone’ of acetabular position described by Lewinnek et al. (anteversion 15°±10°; inclination 40°±10°).

Materials and Methods

A series of 65 hips all with symptomatic osteoarthritis undergoing THR were investigated. Patients with dysplastic hips were excluded. All patients had a navigated THR as part of their normal clinical treatment. A commercially available non image based computer navigation system (Orthopilot BBraun Aesculap, Tuttlingen, Germany) was used. Anterior pelvic plane was registered using the two anterior superior iliac spines and pubic symphysis. Inner size of the empty acetabulum was sized with cup trials and appropriately size trial fixed with a computer tracker was then aligned in the orientation of the natural acetabulum as defined by the acetabular rim ignoring any osteophytes. The inclination and anteversion were calculated by the software.

The acetabular inclination in all hips was also measured on pre-operative anteroposterior pelvic digital radiographs. Acetabular inclination was measured using as the angle between a line passing through the superior and inferior rim of the acetabulum and a line parallel to the pelvis as identified by the tear drops, using the method described by Atkinson et al.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 177 - 177
1 Jan 2013
Deep K Duffy S Freer I Goudie S Nalwad H Deakin A Payne A
Full Access

Traditionally sequential medial soft tissue release is performed for balancing in total knee arthroplasty for varus knees. Its effects on kinematics have been described in extension and 90° flexion in coronal plane. This is the first study to describe its effects on kinematics throughout flexion. 12 cadaveric knees were studied using a computer navigation system to assess kinematics. Femoro-Tibial-Mechanical-Angle(FTMA) was studied in extension, 0°, 5°, 30°,45°,60°,90° and maximum flexion. Sequential medial release was performed in 7 steps, described by Luring et al(Ref). At each step FTMA was measured without and with stressing. A 10 Newton Meter moment arm was applied for varus and valgus stress. Most of the initial release steps had little effect on FTMA without force applied, especially in the initial 60° of flexion. Application of varus force demonstrated very small changes. Application of valgus force demonstrated little change in initial arc of flexion until step 5 was reached (Table 1). Our study concludes the present sequence of medial release may not be correct and should be further investigated to modify the sequence for soft tissue balancing in TKR surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 62 - 62
1 Oct 2012
Deep K Menna C Picard F
Full Access

The aim of the study was to investigate rotational behaviour of the arthritic knee before (preimplant) and after (postimplant) total knee replacement (TKR) using (image-free navigation system as a measurement tool which recorded the axial plane alignment between femur and tibia, in addition to the coronal and sagittal alignment as the knee is flexed through the range of motion. The data on the rotation of the arthritic knee was collected after the knee exposure and registration of the lower limb (preimplant data). The position of rotation between the femur and tibia was recorded in 30° flexion, 45°, 60°, 90° and maximum degrees of flexion of the knee. The data was divided into subsets of varus and valgus knees and these were analysed pre and postimplant for their rotational position using SPSS for statistics.

The system was used in 117 knees of which 91 had full data set available (43 male 48 female). These included 71 varus knees, 16 valgus knees and 4 neutral knees to start in extension. Preimplant data analysis revealed there is tendency for the arthritic knees to first go in internal rotation in the initial part of flexion to 30 degrees and then the rotation is reversed back. This happens irrespective of the initial starting rotational relationship between femur and tibia in full extension. This happens in both varus as well as valgus arthritic knees. This trend of internal rotation in this initial part of flexion is followed in TKR as well implanted with fixed bearing CR knees irrespective of the preoperative deformity. Also noteworthy was the difference in rotation at 30°, 60° and 90 degrees of flexion between preimplant and postimplant knees (irrespective of varus and valgus groups).

When calculated at different points of flexion, there was statistically significant difference in the change of rotation at each point of flexion except 45 degree of flexion. The pre-operative values of change in rotation (internal being positive) at each step from the extended position being 5.4° (SD 4.5°) at 30 ° flexion, 4.7°(5.2°) at 45°, 3.6°(6.1°) at 60°, 3.5°(7.2°) at 90° and 4.2°(8.3°) at maximum flexion. Corresponding post-operative rotations were 2.2°(4.8°), 4.1°(6.4°), 6.6°(7.3°), 9.9°(8.8°) and 7.7°(8.9°). There was also an increase in the total range of rotation that the knee goes through after it has been implanted with prosthesis although it may not happen in every knee. This is statistically significant (p value <0.001) and seems more so in valgus group. The rotational movements and interrelationship of the femur and tibia is a complex issue, especially in the arthritic knees. Preimplant arthritic knee behaved generally similarly to normal knees according to the literature. Normal gait pattern demonstrates that the tibia moved through a 4° to 8° arc of internal rotation relative to the femur. The overall range (10.2° =/−4.2°) of knee rotation in this study greater than 8° might be explained by preimplant data acquired after the knee was approached and therefore releasing knee soft tissue envelop. This study confirmed that during the first 30° both varus and valgus knees moved internally. In our study there is increased range of total rotation postimplant (14° =/−6.8°) which may be explained by the fact that the anterior cruciate ligament is lost in all the TKRs and the posterior cruciate ligament may be dysfunctional as well. Thus the constraints on the knee rotation are decreased postimplant leading to increased rotation. We found some difference between varus and valgus post implant knees in that internal rotation seen in initial 30 degrees of flexion is much more pronounced in valgus knees as compared to varus knees (p value <0.001). This study confirmed knee internal rotation in initial stages of flexion, preimplant in arthritic knees during a passive knee flexion assessment. Varus and valgus knee seemed to behave similarly. This mimics the normal knee rotation. Postimplant knees in TKR behave differently.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 61 - 61
1 Oct 2012
Goudie S Deep K
Full Access

The success of total hip replacement (THR) is closely linked to the positioning of the acetabular component. Malalignment increases rates of dislocation, impingement, acetabular migration, pelvic osteolysis, leg length discrepancy and polyethylene wear. Many surgeons orientate the cup in the same anteversion and inclination as the inherent anatomy of the acetabulum. The transverse acetabular ligament and acetabular rim can be used as a reference points for orientating the cup this way. Low rates of dislocation have been reported using this technique. Detailed understanding of the anatomy and orientation of the acetabulum in arthritic hips is therefore very important. The aim of this study was to describe the anteversion and inclination of the inherent acetabulum in arthritic hips and to identify the number that fall out with the ‘safe zone’ of acetabular position described by Lewinnek et al. (anteversion 15°±10°; inclination 40°±10°).

A series of 65 hips, all with symptomatic osteoarthritis undergoing THR were investigated. Patients with developmental dysplastia of hip (DDH) were excluded. All patients had a navigated THR as part of their normal clinical treatment. A posterior approach to the hip was used. A commercially available non image based computer navigation system (Orthopilot BBraun Aesculap, Tuttlingen, Germany) was used. Rigid bodies (using active trackers) were attached to pelvis and femur. Anterior pelvic plane was registered using the two anterior superior iliac spines and pubic symphysis. The femoral head dislocated and removed and the labrum and soft tissue were excised to clear floor and rim of the acetabulum. Inner size of the empty acetabulum was sized with cup trials and appropriately size trial fixed with a computer tracker was then aligned in the orientation of the natural acetabulum as defined by the acetabular rim ignoring any osteophytes. The inclination and anteversion were calculated by the software. Surgery then proceeded with guidance of the computer navigation system. The computer software defines the anatomical values of orientation, to allow comparison with radiographs these were converted to radiological values as described by Murray et al. The acetabular inclination in all hips was also measured on pre-operative anteroposterior pelvic radiographs. This was done using digital radiographs analysed with the PACS system (Kodak, Carestream PACS Client, version 10.0). Acetabular inclination was measured using as the angle between a line passing through the superior and inferior rim of the acetabulum and a line parallel to the pelvis as identified by the tear drops, using the method described by Atkinson et al.

All patients were Caucasian and had primary osteoarthritis. There were 29 males and 36 females. The average age was 68 years (SD 8). Mean anteversion was 9.3° (SD 10.3°). Anteversion for males was significantly lower than females with a mean difference of −5.5° (95%CI −10.5°,−0.5°) p = 0.033 but there was no significant difference in the number falling outside the “safe zone”. Mean inclination was 50.4° (SD 7.4°). There was no significant difference between males and females with respect to inclination angle or the number that fell outside the “safe zone”. Overall 69% of patients had a combined inclination and anteversion of the native acetabulum that fell outside the “safe zone” of Lewinnek.

Mean acetabular inclination falls out with the ‘safe zone’. This trend has been seen in a recent study of arthritic hips using CT scans which found that the average angle of inclination in both males and females was greater than the upper limit of the safe zone. This study using CT also demonstrated a statistically significant 5.5° difference between males and females in terms of anteversion. This is the same as the figure we have found in our work. Inherent acetabular orientation in arthritic hips falls out with the safe zone defined by Lewinnek in 69% of cases. When using the natural acetabular orientation as a guide for positioning implants it should therefore not be assumed this will fall with in the safe zone although the validity of safe zones itself is questionable. Variation between patients must be taken into account and the difference between males and females, particularly in terms of anteversion, should also be considered.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 3 - 3
1 Jun 2012
Goudie S Deep K
Full Access

Native anatomy of the arthritic hip is an important consideration in hip replacement surgery and implant design. Acetabular component orientation in total hip replacement (THR) is the single greatest factor that influences dislocation rate. Detailed knowledge regarding orientation of the native acetabulum is therefore essential. Native acetabular orientation in healthy hips is well documented but we could not find any papers detailing native acetabular orientation in the arthritic hip.

A commercially available computer navigation system (Orthopilot BBraun Aesculap, Tuttlingen, Germany) was used to assess acetabular inclination and anteversion in 65 hips with symptomatic arthritis requiring THR. Acetabular inclination in all hips was also measured on pre op anteroposterior pelvic radiographs.

Patients with DDH were excluded. All patients were Caucasian and had primary osteoarthritis, 29 males and 35 females. Average age 68(SD 8). Mean values as recorded by computer navigation were: inclination 51.4°(SD 7.1); anteversion 11.7°(SD 10.7). As recorded from radiographs mean acetabular inclination was 58.8°(SD 5.7). There was a difference between males and females. Mean navigated inclination: male 50.5°(SD 7.8); female 52.1°(SD 6.7). Mean navigated anteversion: male 8.3°(SD 8.7); female 14.39°(SD 11.6) Mean radiographic inclination: male 57.4°(SD 5.1) and female 59.8°(SD 6)

Natural acetabular orientation in arthritic hips falls out with the safe zones defined by Lewinnek. When compared with healthy hips, as described in current literature, the arthritic hip appears to have a smaller angle of inclination and anteversion, by approximately 5° and 10° respectively, in both males and females. This is useful when positioning the cup during surgery. The difference between males and females, particularly in terms of anteversion, should also be considered.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 12 - 12
1 Apr 2012
Menna C Deep K
Full Access

Total knee arthroplasty (TKA) is a common orthopaedic procedure. Traditionally the surgeon, based on experience, releases the medial structures in knees with varus deformity and lateral structures in knees with valgus deformity until subjectively they feel that they have achieved the intended alignment. The hypothesis for this study was that deformed knees do not routinely require releases to achieve an aligned lower limb in TKA.

A single surgeon consecutive cohort of 74 patients undergoing computer navigated TKA was examined. The mechanical axes were taken as the references for distal femoral and proximal tibial cuts. The trans-epicondylar axis was taken as the reference for frontal femoral and posterior condylar cuts. A soft tissue release was undertaken after the bony cuts had been made if the mechanical femoro-tibial (MFT) angle in extension did not come to within 2° of neutral as shown by computer readings. The post-operative alignment was recorded on the navigation system and also analysed with hip-knee-ankle (HKA) radiographs.

The range of pre-operative deformities on HKA radiographs was 15° varus to 27° valgus with a mean of 5° varus (SD 7.4°). Only two patients required a medial release. None of the patients required a lateral release. The post implant navigation value was within 2° of neutral in all cases. Post-operative HKA radiographs was available for 71 patients. The mean MFT angle from radiographs was 0.1° valgus (SD 2.1°). The range was from 6° varus to 7° valgus but only six patients (8.5%) were outside the ±3° range. The kinematic analysis also showed it to be within 2 degrees of neutral throughout the flexion making sure it is well balanced in 88% cases.

This series has shown that over 90% of patients had limbs aligned appropriately without the need for routine soft tissue releases. The use of computer assisted bone cuts leads to a low level of collateral release in TKA.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 391 - 391
1 Jul 2011
Deep K Picard F Baines J Deakin A Kinninmonth A Sarungi M
Full Access

Arthritic knees, for the purpose of surgical correction during arthroplasty, are generally thought to be either varus knees or valgus knees and soft tissue releases are done in accordance with the same concept. This view is dependent on the clinical deformity in extended knee and the plain AP radiograph of the extended knee. This concept is now challenged by the observations from our study of the arthritic knee kinematics using computer aided navigation when performing total knee replacement arthroplasty. We performed 283 total knee replacements with computer aided navigation. Imageless navigation was used with Stryker and Orthopilot systems. Bone trackers were fixed to the bones and through real time infrared communication the data was collected. The knee kinematics were recorded before and at the end of surgery. This included measurement of biomechanical axis with the knee extended and then gradually flexed. The effect of flexion on the coronal alignment was recorded real time on the computer. The results were then analysed and compared with plain radiographic deformity on long leg films.

Majority of the knees did not behave in a true varus or valgus fashion. We classified the deformity into different groups depending on the behavior of the knee in coronal plane as it moves from extension to flexion. 2 degree was taken as minimum deviation to signify change, as the knee bends from full extension to flexion. The classification system is as follows

Neutral

Deformity - Varus/Valgus to start with in extension

Gp1

Deformity remains the same as the knee flexes

Increasing deformity as the knee flexes

Gp2

Decreasing deformity but does not reach neutral in flexion

Decreasing deformity reaches neutral in flexion

Gp3

Decreasing deformity and crosses to opposite (Varus to valgus or valgus to varus) deformity in flexion

Gp4

Deformity first increases and then decreases but does not reach neutral

Deformity first increases and then decreases to neutral

Deformity first increases and then decreases to cross over to opposite deformity in flexion

Traditional releases of medial or lateral structures without realising the true picture of what happens when the knee is flexed, may not be correct. From our study it is clear that not all arthritic varus or valgus knees behave in the same way. Some of the releases we perform conventionally may not be required or need to be modified depending on the knee kinematics.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 389 - 389
1 Jul 2011
Nunag P Willcox N Deakin A Deep K
Full Access

The recognition of the correct pattern and severity of deformity in knee osteoarthritis has important implications in its surgical management. Our unit routinely uses standing long leg films and computer navigation. However, these modalities are not widely available and most surgeons rely on clinical assessment and short films. Our experience is that clinical assessment can give the opposite impression of the true deformity pattern particularly among obese patients and there is evidence that short knee films are not reliable. Our study aims to compare clinical, radiographic and computer measurements of knee deformity, assess the influence of Body Mass Index and asses the relationship between coronal and flexion deformity.

We measured 52 consecutive knees prior to arthroplasty using clinical, long leg radiographs and computer navigation methods. Systematic clinical measurement was done with patient standing. Standing radiographs stored in a Picture Archiving System were measured by two independent observers. The senior surgeon performed computer measurement while applying axial load to the foot to simulate weight bearing.

Using long leg films as baseline, clinical and X-ray measurement had a mean error of 0.8° (−12 to +12). Seven clinically valgus knees turned out varus on X-ray. Mean BMI for this group was the same as the rest. Using navigation as baseline, clinical and navigation coronal measurements had a mean error of 0.3° (+9 to −10.5). Four clinically valgus knees turned out varus with navigation. Mean BMI for this group was the same as the rest. Flexion deformity was similar between clinical and computer measurement. Three clinically normal knees showed significant varus in both X-ray and navigation. Compared directly, radiographic and navigation coronal deformity showed significant difference in the degree of deformity but not in the pattern of deformity. There was no correlation between BMI and both the error in clinical assessment of coronal deformity and navigation coronal alignment. If flexion deformity was > 5°, higher BMI indicates higher flexion deformity. There was a weak correlation between navigation coronal and flexion deformity.

Although error in clinical measurement did not reach statistical significance, based on our result, clinical assessment can give an incorrect pattern of deformity in up to 13% and hence should not be the sole basis of assessing deformity. Contrary to expectation, BMI did not influence error of clinical assessment or severity of coronal deformity. It however appeared to influence larger flexion deformities. The discrepancy between radiographic and navigation measurements reflects the absence of true weight bearing with navigation even though we tried to simulate this by applying axial load to the foot.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 392 - 392
1 Jul 2011
Deep K Willcox N Smith B Deakin A
Full Access

It is generally accepted that Hip-Knee-Ankle (long-leg) radiographs are a good measurement tool for biomechanical axis of the knee and they have been used as the outcome measure for many studies. Most of the surgeons recommend having pre operative and post operative long leg radiographs for total knee replacement surgery, although practice is not as common. We studied the biomechanical axis on long-leg films and compared it with computer navigation.

The objectives were to find out repeatability of measurements of biomechanical axis with inter observer readings on long leg radiographs and to compare biomechanical axis measurements with Navigation values obtained during total knee replacement surgery.

Our institution routinely uses long-leg radiographs for total knee replacement (TKR) surgery both pre- and post-operatively. A series of 209 patients who had navigated TKR between Jan 2007 and 2008 were selected. Stryker and Orthopilot systems for navigation were used. The intra-operative biomechanical axis measurements from the computer navigation files both pre-and post- implant were recorded. The long leg films were measured with a defined protocol from the digital images on PACS system. Centre of the head of femur was taken as the upper point. For the knee centre the midpoint of a line joining the distal femoral notch centre and upper tibia was used. For the ankle centre midpoint of the upper talar margin was used. An angle between the three points represented the radiological biomechanical axis. To investigate inter-observer error, two observers measured the pre- and post-operative biomechanical axis on long leg radiographs independently on 57 patients.

For the inter-observer measurements on 57 patients, the intraclass correlation coefficient was 0.99 for pre-operative radiographs and 0.98 for post-operative radiographs. Maximum difference between the two observers was 2° in four cases. All other cases showed the same readings or 1° difference.

There was a strong correlation, which was statistically significant, between the pre-operative radiographic and navigated measurements with Pearson correlation coefficient of 0.810 (p< 0.001). The maximum difference between the radiographic and navigated measurement was 24 degrees. The relationship between the postoperative measurements was weaker but statistically significant with Pearson correlation coefficient of 0.323 (p< 0.001). The maximum difference between the two methods of measurement was larger 15.5.

It can be concluded from this study that biomechanical axis on a long leg radiograph is a repeatable measure with good inter-observer correlation.

Although it is statistically significantly correlated with navigated readings, the absolute values may be different with both the methods. This raises the question on the reliability of long leg radiographs for the prediction of true biomechanical axis. Most of the larger value differences had a fixed flexion deformities (9 – 45 degrees). This can affect the readings on the long leg radiographs and make the deformity look either smaller or bigger. Also as our knee kinematic study has proven that the deformity does not remain the same in flexion as it was in extended knee that could also account for the difference in the readings. Other reasons for difference in the pre operative readings could be weight bearing status and surgical opening of the joint before taking the pre operative biomechanical axis measurements. Difference in the post operative readings could be attributed to weight bearing status, time length between navigation and radiographic measurements (6–12 wks), scarring of the soft tissues in the time and flexed posture of knee in the early post operative period.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 391 - 391
1 Jul 2011
Deep K Menna C
Full Access

Total knee arthroplasty (TKA) is one of the commonest orthopaedic procedures. Traditionally the surgeon, based on experience, releases the medial structures in knees with varus deformity and lateral structures in knees with valgus deformity until subjectively they feel that they have achieved the intended alignment. The aim of this prospective study was to record the frequency of medial and lateral releases for computer navigated TKAs.

Seven four consecutive patients operated on by a single surgeon were included in this study. All patients had TKA using either Stryker or Orthopilot computer navigation systems. The implants used were Scorpio NRG or Columbus. The biomechanical axis was taken as the reference for distal femoral and proximal tibial cut. The trans-epicondylar axis was taken as the reference for frontal femoral and posterior condylar cuts. A soft tissue release was undertaken after the bony cuts had been made if the biomechanical axis did not come to within 2° of neutral as shown by computer readings in extension. The post-operative alignment was recorded on the navigation system and also analysed with long leg hip knee ankle radiographs.

There were 43 female and 31 males in the study, 34 left and 40 right knees with an age range of 43 to 87 years. The range of pre-operative deformities on long leg radiographs was 15° varus to 27° valgus with a mean of −5.0° and SD 7.4°. Only two patients needed a medial release. None of the patients needed a lateral release. The fixed flexion deformities needed posterior release. None of the patients needed lateral release for patellar tracking. Post-operative alignment was available for 71 patients. The post implant navigation value was within 2° of neutral in all cases. The mean biomechanical axis on radiographs was 0.1° valgus with a SD 2.1° and range from 6° varus to 7° valgus. From the radiographs six patients were outside the ±3° range.

If one sticks to biomechanical axis and transepicondylar axis as the reference for bony cuts, there will be minimal requirement for medial or lateral soft tissue release. According to our results the use of computer navigation gives a low frequency of medial and lateral release in total knee replacement. Other authors have also found that navigation data can help to give a lower rate of soft tissue release, such as Picard et al. who had decreased their soft tissue release to 25%.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 65 - 65
1 Jan 2011
Deep K Willcox N Smith B
Full Access

It is generally accepted that Hip-Knee-Ankle (long-leg) radiographs are a good measurement tool for biomechanical axis of the knee and they have been used as the outcome measure for many studies. Most of the surgeons recommend having pre operative and post operative long leg radiographs for total knee replacement surgery, although practice is not as common. We studied the biomechanical axis on long-leg films and compared it with computer navigation. The aims were

To find out repeatability of measurements of biomechanical axis with inter observer readings on long leg radiographs

To compare X-ray biomechanical axis measurements with Navigation values obtained during total knee replacement surgery.

Our institution routinely uses long-leg radiographs for total knee replacement (TKR) surgery both pre- and postoperatively. A series of 209 patients who had navigated TKR between Jan 2007 and 2008 were selected. Stryker and Orthopilot systems for navigation were used. The intra-operative biomechanical axis measurements from the computer navigation files both pre-and post- implant were recorded. The long leg films were measured with a defined protocol from the digital images on PACS system. Centre of the head of femur was taken as the upper point.

For the knee centre the midpoint of a line joining the distal femoral notch centre and upper tibia was used. For the ankle centre midpoint of the upper talar margin was used. An angle between the three points represented the radiological biomechanical axis. To investigate inter-observer error, two observers measured the pre- and postoperative biomechanical axis on long leg radiographs independently on 57 patients. For the inter-observer measurements on 57 patients, the intraclass correlation coefficient was 0.99 for pre-operative radiographs and 0.98 for post-operative radiographs. Maximum difference between the two observers was 2° in four cases. All other cases showed the same readings or 1° difference. There was a strong correlation, which was statistically significant, between the pre-operative radiographic and navigated measurements with Pearson correlation coefficient of 0.810 (p< 0.001). The maximum difference between the radiographic and navigated measurement was 24 degrees. The relationship between the post-operative measurements was weaker but statistically significant with Pearson correlation coefficient of 0.323 (p< 0.001). The maximum difference between the two methods of measurement was larger 15.5.

It can be concluded from this study that biomechanical axis on a long leg radiograph is a repeatable measure with good inter-observer correlation. Although it is statistically significantly correlated with navigated readings, the absolute values may be different with each method. This raises the question of the reliability of long leg radiographs for the prediction of true biomechanical axis. Most of the larger value differences had a fixed flexion deformities (9 – 45 degrees). This can affect the readings on the long leg radiographs and make the deformity look either smaller or bigger. Also, our knee kinematic study has proven that the deformity does not remain the same in flexion and in the extended knee. This could also account for the difference in the readings. Other possible reasons for differences in the pre operative readings: the weight bearing status and the surgical opening of the joint, before taking the pre operative biomechanical axis measurements. Differences in the post operative readings could be attributed to: weight bearing status, time length between navigation and radiographic measurements (6–12 wks), scarring of the soft tissues in the meantime and flexed posture of knee in the early post operative period.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 535 - 535
1 Oct 2010
Deep K Bains J Deakin A Kinninmonth A Munro N Picard F Sarungi M Smith B Wilson C
Full Access

Introduction: The knee joint replacement arthroplasty is a very successful procedure. Traditionally we aim to perform the arthroplasty and recreate the patients’ biomechanical axis and correct the coronal plain alignment deformity. Unfortunately till recently there was no fine way of controlling the exact alignment and depending on surgeon to surgeon, a valgus (to anatomical axis) of 3 to 7 degrees is aimed for using mechanical intra or extramedullary jigs. On proper measurements only 70–80% of knees achieve the aimed result at best as can be seen in the literature. With the advent of computer aided navigation we can now achieve the desired alignment in a much higher percentage of patients.

Material: We performed 1000 total knee arthroplasties at our hospital. Out of these 500 were performed using computer navigation and 500 using conventional mechanical jigs. Pre op and post op long leg alignment films were taken using standardised method. The data was collected using oxford scores and from computer navigation machines and plain radiographic analysis. The observers doing the radiographic analysis were blinded as to whether the patient had procedure done by conventional means or by computer navigation. Sub grouping of the deformities was done depending on the amount of deformity.

Results: 500 patients had the operation done by conventional means and the other 500 with computer navigation guidance. Further subgroups were made depending on the amount of pre-existing radiological deformity 0–5, 6–10, 11–15 and more than 15 degrees of varus or valgus deformity. The effect of gender, bmi, surgeon experience, clinical oxford score outcome was also considered. It was clear that the patients who had more severe deformities and valgus deformities had better post operative alignments after the procedure was performed with computer navigation as compared with the conventional means. There was statistically significant difference observed between the subgroups.

Discussion: Orthopaedic surgery has improved with technical advancements over the number of years. With any new procedure it takes a long time to shed the old beliefs and adapt the new concepts. While we have plenty of evidence in literature and from our study that computer navigation can give better desired alignment after total knee arthroplasty especially with more severe deformities, it still needs to be taken up by majority of orthopaedic surgeons. Ours is the first study to demonstrate the difference in the specific subgroups.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 558 - 558
1 Aug 2008
Deep K Fleetcroft J Zouralidis H Rehman N
Full Access

Introduction: Computer aided surgery has been used in orthopaedics for over a decade now. It has mainly found its use in knee and hip arthroplasty. Its use in other areas is still under development. There has been only one published report in literature on its use in patello femoral joint replacement arthroplasty. We did a study to evaluate its use in patello-femoral arthroplasty.

Methods: A retrospective group of patients was selected who had patello-femoral joint arthroplasty under one of the authors with non navigated standard technique. This was compared with another group which was followed prospectively and had it done with minimally invasive technique using computer aided navigation. The main factors compared were blood loss, incision size and hospital stay.

Results: Thirteen patients had patello-femoral arthroplasty. Seven had with aid of computer aided navigation technique. There was a distinct advantage of computer aided surgery in blood loss, hospital stay and size of incision. It had no bearing on the surgical outcome in short term. Long term results are still awaited.

Conclusion: While our study is only short term and does not have many patients, there seems to be a distinct advantage in terms of hospital stay and size of incision.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 440 - 440
1 Oct 2006
Deep K Donnelly W
Full Access

Computer aided joint replacement surgery is being used increasingly. It is more commonly used at present in the knee replacement surgery as compared to hip replacement arthroplasty. It is still under developmental phase. The published literature shows there is increased accuracy of the component placement of acetabular cup and femoral stem. We describe the technique for the Stryker navigation system as used in total hip arthroplasty.

The technique used by us presently is an active tracker system. This is a both way communication system of infrared waves between the trackers and the sensors. The trackers are fixed to the bones, then the registration of patient specific anatomy is done and hip arthroplasty is performed with aid of the computer navigation.

The computer navigation gives the values of the component orientation in space. It gives the implant position in the pelvis and femur models generated by the computer but fed in and created by the surgeon. It is important that the data fed to the computer in making the model of pelvis and femur is accurate. It is surgeon dependent. At the end of surgery one can also evaluate impingement and range of motion. It also shows the change in offset of the centre of rotation of the hip as well as leg lengthening. While it can aid in the technical performance it is essential that the surgeon does not go blind to his operating environment as the computer navigation is to help the surgeon, not replace.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 442 - 442
1 Oct 2006
Deep K
Full Access

Computer aided joint replacement surgery is being used increasingly. It has found its most common use in the total knee replacement arthroplasty. Although the literature has proven its accuracy in the alignment of the components, we still await the long term benefits in terms of patient outcome and longevity of the prosthesis.

The parameters of the alignment are created and fed to the computers, although most of these are based on long term wisdom and on the historical observations rather than on hard scientific studies as to the ideal positioning of the implants for each specific individual. It is therefore important that while using the computer guidance we understand what are the technical assumptions and points based on which the computer is guiding us. A presentation of these will be done mainly based on Stryker knee navigation system.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 441 - 441
1 Oct 2006
Deep K Donnelly W
Full Access

The use of computer aided joint replacement surgery is increasing exponentially. Its use in hip arthroplasty is still under developmental phase. Although the available literature shows there is increased accuracy of the component placement but there can be a number of factors on which it relies.

We have used the Stryker navigation system to aid in total hip arthroplasty for more than four years. It is improving continuously with time. Still there are many factors which are completely surgeon dependent and which can cause lot of variations in the component placement. Most important factors are the registration of patient anatomy and fixity and immobility of the bone trackers during the procedure. A number of other simple things can produce errors. We carried out some studies to see the effect on navigation values which will be presented. While use of computer navigation can aid greatly in achieving the set goals, it is dependent on surgeon thought process and appropriate implementation of the procedure.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 439 - 439
1 Oct 2006
Deep K Donnelly W Morar Y Ward N Tevelan GA Dunster KR Crawford R
Full Access

Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to assess the forces needed to displace the tracker attachment devices in the bone simulators.

Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices.

The forces required to produce translation increased with the increasing diameter of the pins. These were 105 N, 185 N, and 225 N for the unicortical fixations and 130N, 200N, 225 N for the bicortical fixations for 3mm, 4mm and 5 mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210 N and 150 N respectively.

The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more than the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less than that can be produced by the accidental leaning or bang produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135 N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 154 - 154
1 Mar 2006
Agarwal A Deep K
Full Access

Traumatic rotatory atlanto-axial dislocation and subluxations are rare injuries. The diagnosis is often missed or delayed because of subtle clinical signs. Head tilt makes the interpretation of plain radiographs difficult. Delayed diagnosis often results in chronic instability necessitating surgical stabilization. A hitherto undescribed clinical sign was evaluated which should lead to increased awareness and avoid delay in the diagnosis.

Why a new clinical sign?

Easily missed injury

Uncommon but not that uncommon

Difficult to diagnose

Needs high index of suspicion

Not much emphasis given in training

Radiographs usually inconclusive because of torticollis deformity Prerequisites for test

Patient should be conscious

A Lateral radiograph should not show any facet dislocations or fractures in cervical spine

Explain the patient what you intend to do and he/she should report any paraesthesias, sensory or motor symptoms if felt during the test Clinical sign- Elastic Recoil:

Supine patient

Hold head carefully with hands on either side of the head

Instruct patient to report any neurological deterioration

Try to straighten the head tilt gently

Once it is corrected, release the supporting hand towards tilt of the head taking care not to let the head overshoot the original position

An elastic recoil of the head to previous position indicates a positive test

Methods: This study was carried out between 1997 to 2003. The test was applied to 59 patients presenting in Accident and Emergency. All this patients had head tilt even after the application of a hard cervical collar. All the 59 patients had CT scans to confirm or exclude the diagnosis of Rotatory atlanto axial dislocation/subluxation.

Results: The new clinical sign was found to be positive in all the fourteen patients with atlanto- axial rotatory dislocations/subluxations which was confirmed by CT scan. The test was also found to be positive in 5 patients with unilateral facet joint dislocation. The sensivity of the test in our study was 100%. The specificity was 89%, positive predictive value 0.73, negative predictive value 0.9 (90%).

Conclusion: This new clinical sign may help in early recognition of the injury and also act as an effective screen to indicate which patient needs a CT scan to confirm the diagnosis. This can also be applied in places where the CT scan facilities are not readily available especially in the developing nations.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 119 - 119
1 Mar 2006
Agarwal A Selven Hammer A Deep K Morar Y
Full Access

Purpose of the study: To establish the difference between AO plate osteosynthesis and Elastic Stable Intramedullary Nailing and the long-term outcome.

Design: Prospective randomised study.

Material: During 2000 and 2002 prospective randomised study was carried out where children with diaphysial fracture of long bone was either treated with osteosynthesis with AO plate or ESIN. 32 children had AO plate osteosynthesis and 34 children had ESIN procedure.

Methods: In our series of patients managed with ESIN Nailing 24 had forearm fracture 6 had femur fracture 2 had humeral and 2 had tibial fracture. The other group with AO plate osteosynthesis had 25-forearm fracture 1 humeral fracture 4 tibial fractures and 2 femoral fractures.

Results: The group treated with AO plate osteosynthesis 2 had rotational deformity and rest did well. The recovery period after removal of metal work was longer.

The group treated with ESIN procedure 1 patient fell down and bend the C-Nail, which was straightened in situ, and the fracture healed with slight curvature of the femur, which corrected slowly with growth. The forearm fractures did not have any rotational deformity. The recovery period post removal of the ESIN was very short.

Conclusion: We find that ESIN is a superior procedure for diaphysial fractures of long bone in children and AO plating should only be done in cases where ESIN is not possible.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 283 - 284
1 Mar 2004
Deep K Norris M Smart C Senior C
Full Access

Introduction: Recently there has been a trend for recommending weight bearing 30û ßexion views as the standard view in place of full extension view for the routine radiography of the Knee. It has been shown that this view can pick up more abnormalities and can show a joint space diminution, which cannot be seen on full extension views. It has not been shown by any study that this is not due to the differential thickness of cartilage in different places on femoral condyle thus implying a natural cause rather than pathological process (abnormal wearing of cartilage) of the observed decrease in joint space. So this prospective randomised double blind study was designed. Methods: 22 patients with arthroscopically proven non osteoarthritic knees were included in the study. Knee radiographs were taken in weight bearing full extension and 30û ßexion PA views. The radiographs were randomised and read by a consultant, registrar & senior house ofþcer. Results: Appropriate statistical tests were applied and results analysed. There was up to 2mm difference in the joint space on the two views. Conclusion: The decrease in the joint space if seen on 30û ßexion views as compared to full extension views may be due to the differential thickness of inherent normal cartilage and so is not always due to a pathological process. Based on this a classiþcation was devised to signify the importance of measured differential thickness in the cartilage of femoral condyle.