header advert
Results 61 - 80 of 82
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 51 - 51
1 Sep 2012
Edwards G Hall A Morgan-Jones R
Full Access

We describe the results for the management of chronic osteomyelitis in long bones using a new single stage procedure, the Cardiff technique. Fourteen consecutive patients were treated prospectively. The patients had a mean age of 52; all patients had a mean stay in hospital of 5 days with outpatient dressings. All patients had tibial fractures, 2 were infected non unions. The origin of infection was traumatic in 13 cases and haematogenous in 1 case. This one stage procedure or The Cardiff technique, uses techniques described by both Papineau's 3 stage method and Lautenbach's procedure. It involves removal of all avascular and infected tissue via marginal debridement, opening of the medullary cavity proximally and distally, compartmental debridement and copious saline irrigation. The wound is then packed with Jelonet and kaltostat and fresh dressings applied weekly. The wound is left to heal via secondary intention. There is no routine use of antibiotics. Antibiotics were only used when required, i.e. Clinical evidence of cellulitis or infection. 11 patients healed with no further surgery, no skin grafting, no bone grafting and no flap coverage. Mean time to healing was 5 months; both non unions united giving results similar to other accepted techniques. There were 3 residual infections, 2 due to inadequate debridement which required a single further compartmental debridement (Lautenbach method), 1 had an avascular bone edge requiring further local debridement. We feel this procedure confers the following advantages; minimal surgical insult, early discharge, out patient management, good outcomes and most importantly, high patient satisfaction. It also serves as a reminder that simple wounds do well with simple solutions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 85 - 85
1 Jul 2012
Jain R Majid I Liu A Jones R Johnson D
Full Access

Aim

To determine the tensile forces across the knee extensor mechanism during walking, in simulated conditions of treatment.

Methods

Gait analysis of six normal subjects was performed, with full weight bearing unilateral immobilisation of the knee during walking. Measurements were taken without then with a brace, unlocked then locked at 0°, 0-10°, 0-20° and 0-30° of flexion. Mean and maximum knee flexion angles were measured, followed by calculation of the mean and maximum forces across the extensor mechanism during loading, supporting and propulsion phases of gait.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 56 - 56
1 Jul 2012
Azam A Agarwal S Morgan-Jones R
Full Access

Purpose of the study

This study was undertaken to evaluate the early results of a new implant system - the metaphyseal sleeve - in revision total knee replacement. The femoral and tibial metaphyseal sleeves are a modular option designed to deal with metaphyseal bone loss and achieve cementless fixation over a relatively wide area in the metaphysis.

Methods

Over three years, femoral and/or tibial metaphyseal sleeves were implanted in 104 knees in 103 patients (54 male and 49 female). The clinical notes and radiographs of these patients were reviewed retrospectively. Thirty one patients had revision for infection, 42 for aseptic loosening, and 31 for instability, pain or stiffness. Eighty nine knees were revised as a single stage and 15 were done as two stage procedure. Minimum follow up is 12 months (average 18.5 months).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XV | Pages 1 - 1
1 Apr 2012
Carrothers A Gallacher P Gilbert R Kanes G Roberts S Rees D Jones R Hunt A
Full Access

Background

The mechanical disadvantage and detrimental effect to articular cartilage following meniscectomy has been well documented in the literature. Meniscal repair in the avascular (white on white zone) is controversial and would be deemed inappropriate by many.

Methods

Prospective data collection on all meniscal repairs between 1999 and 2008. 423 patients underwent meniscal repair at our unit during this time. We identified 88 patients who underwent a meniscal repair of a non peripheral tear (white on white zone) where there was no co-existent ACL injury or instability. There were 74 males and 14 females with a mean age of 26 years (13-54). There were 50 medial meniscal tears and 38 lateral tears, all in the non peripheral area of the meniscus. The criterion for failure was any reoperation on the same meniscus requiring excision or re fixation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 59 - 59
1 Mar 2012
Gallacher P Gilbert R Carrothers A Kanes G Roberts S Rees D Jones R Hunt A
Full Access

Hypothesis

Avascular meniscal tears can be repaired with good clinical outcomes.

Background

The mechanical disadvantage and detrimental effect to articular cartilage following meniscectomy has been well documented in the literature. Meniscal repair in the avascular (white on white zone) is controversial and would be deemed inappropriate by many.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 57 - 57
1 Mar 2012
Gudena R Mehta J Male K Evans C Jones R
Full Access

Introduction

Review the results of modified Lautenbach procedure (new method) to treat chronic osteomyelitis of the long bones.

Patients and methods

Retrospective analysis of sixty-seven patients with osteomyelitis of the long bones treated over 5-year period with modified Lautenbach procedure. Four patients were excluded from this study, as we were unable to retrieve the case notes. 48 men and 16 women were included and the average age was 33 years. All these patients had prior operative intervention including plating, intramedullary nailing or external fixator. Forty-seven patients had discharging sinuses and deformed leg. We noted the pre-operative inflammatory markers, bacteriology and pain score. We also recorded the duration of the hospital stay, post-operative recovery, deformity and the ability of the patient to resume his prior occupation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 78 - 78
1 Mar 2012
Jeavons RP Dowen D Jones R O'Brien S
Full Access

Simultaneous bilateral Total Knee Arthroplasty (TKA) has been reported to bring greater patient satisfaction, reduce in-patient stay and recovery, with similar outcomes to single sided or staged TKA, but higher complication rates. No validated selection criteria exist.

We report the results of a single surgeon's experience of simultaneous bilateral TKA, using set guidelines for patient selection.

A prospectively maintained database of all simultaneous bilateral TKA performed between 2002 and 2008 was retrospectively analysed, supplemented by case-note review. Outcome measures included length of stay, blood loss and transfusion rates, complications and functionality and validated outcome scores.

40 patients were included, 23 male and 17 female, all with osteoarthritis. Mean age was male 64.9 and female 61.3 years. Mean ASA grade was 1.8. All fitted selection criteria. Mean tourniquet time was right 79.1 minutes and left 83.6 minutes. Preoperative mean haemoglobin level was 141.8 g/dl and mean post operative level of 87.3 g/dl. 13 patients received purely autologous blood transfusion, 16 patients purely allogenic and 6 patients received both. There was 1 intraoperative complication (Medial collateral injury), 3 minor post operative complications which recovered prior to discharge. There were no thromboembolic events or deaths. Mean follow-up was 32.7 months (range 3-79 months). Mean in-patient stay was 7.5 days. Mean range of movement at most recent follow up was right 1.0 to 119.1 degrees flexion and left 1.0 to 120.8 degrees flexion. Mean Knee Society Scores pre- versus post-operatively were: 67 knee/62 function versus 90 knee/82 function. Oxford Knee Scores, Pre- versus post-operatively were: 43 versus 35 (Scoring 0-60, lowest best outcome).

We demonstrate that with appropriate selection criteria, simultaneous bilateral TKA is safe and successful, giving excellent functional outcomes.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 41 - 41
1 Jan 2011
Caesar B Morgan-Jones R Warren R Wade R Roberts P Richardson J
Full Access

Thirty-five patients were followed prospectively from their referral to the Problem Fracture Service with chronic osteomyelitis of diaphyseal bone between November 1994 and June 1999.

The patients were treated using a closed double-lumen suction irrigation system following reaming and arthroscopic debridement of the intramedullary canal; this is a modified system based on the work of Charles Lautenbach. Results of these procedures were regularly followed up in clinic, and between June and July 2007 the whole cohort was reviewed via postal questionnaire, telephone and case note review.

At a mean follow up of 101 months, 26 were living with no evidence of recurrence, 4 had died of unrelated causes with no evidence of recurrent infection. Four patients had persisting problems with sinus discharge requiring intermittent antibiotic therapy and 1 patient had his limb amputated for recurrent metaplastic change.

These results gave this cohort an 86% clearance of infection, with recurrence in 12%, which is comparable to the Papineau and Belfast techniques with significantly less surgical insult to the patient.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 8 - 8
1 Jan 2011
Rao M Richards O Meyer C Spencer-Jones R
Full Access

To assess the outcome of knee “arthrodesis” using cemented Endo-Model knee fusion nail in failed Total Knee Replacement (TKR) with significant bone loss due to infection. This is a retrospective case study of seven patients with infected TKR and multiple surgeries with significant bone loss.

All patients had antibiotic loaded cement with a temporary K-nail as a first stage procedure to eradicate infection. All seven patients had “arthrodesis” performed using cemented modular Endo-Model Knee Fusion nail (Waldemar Link, Hamburg) by the senior author. Cement was used to hold the stems in the diaphyses and not used around the coupling mechanism. The “arthrodesis” relied entirely on the coupling mechanism which has been shown to have good axial and torsional rigidity by mechanical testing. Outcome was assessed using pre and post Visual Analogue Score (VAS).

Mean age was 72.3 years(62–86). Mean follow up was 39.6 months (7–68). The VAS pain score improved from pre-operative mean score of 7.9 to a postoperative score of 1.5. One patient suffered fracture of femoral cement mantle at 50 months who underwent a technically easy exchange revision. One patient had recurrent infection with distal femoral fracture at 36 months and was revised to distal femoral replacement.

The Endo-Model knee arthrodesis nail restores limb lengths, has good early results in terms of pain relief and provides a stable knee “arthrodesis” in cases where there is significant bone loss and extensor mechanism insufficiency following an infected TKR.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 409 - 410
1 Jul 2010
Kotwal RS Prasad N Morgan-Jones R
Full Access

Purpose of the study: The purpose of this study is to present our initial experience of single stage revision surgery for infected total knee arthroplasty (TKA).

Methods and results: 12 patients underwent single stage revision for infected TKA. The average patient age was 72.5 years and M: F was 2:1. 5 of the 12 patients had frank infection with presence of discharging sinuses pre-operatively. The procedure involved explantation, debridement, subtotal synovectomy, use of high pressure carbon dioxide (Carbojet) and re-implantation using revision prosthesis and antibiotic laden cement. Utmost care was taken to restore the balance and stability of the revised knee. All the patients were given appropriate intravenous and oral antibiotics in the peri-operative period. Oxford knee scores (OKS) were obtained pre-operatively and at the latest follow-up. Patient satisfaction was also assessed.

At the latest follow-up, none of the patients had recurrence of the infection nor did they need any further surgical procedure. There was no radiographic evidence of loosening of the prosthesis. The OKS had improved from a mean of 17 pre-operative to 41 at the latest follow-up. All the patients were extremely satisfied with the outcome.

Conclusion: Knee function and patient satisfaction improved significantly after single stage revision for infected TKA. None of the patients needed further surgery in the short term. Early results are very encouraging and this change in practice may save on costs and patient morbidity associated with the second stage.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 419 - 419
1 Jul 2010
Kotwal RS Fairclough J Morgan-Jones R
Full Access

Purpose of the study: We report an unusual complication of patella tendon rupture that occurred secondary to the use of static cement spacer blocks in a series of three patients undergoing staged revision total knee arthroplasty (TKA) for infection.

Methods and results: 3 male patients developed patella tendon injury secondary to anterior subluxation of static cement spacer blocks used at the first of a two-stage revision procedure for infected TKA. Average patient age was 70 years. The interval between the 1st and the 2nd stages varied between 3.5 to 24 months. At the second stage, it was observed that the patella tendon was completely severed and irreparable in one case, whereas it was partially injured and repairable in the other two cases. In the case with irreparable tendon injury, stable joint reconstruction could not be achieved at the second stage and ultimately resulted in knee arthrodesis. In the other two cases, 2nd stage revision was performed using hinged revision knee components and the tendon injury was repaired and protected with a circlage wire. None of the patients were satisfied with their outcome at the final review.

Conclusion: This is the first report in the literature reporting the complication of patella tendon rupture secondary to the use of static cement spacer blocks in staged revision knee arthroplasty. The injury can either be repairable or irreparable. The functional outcome and satisfaction is not good after the salvage procedures. Therefore, we recommend that these spacer blocks should not be used in revision knee arthroplasty.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 327 - 327
1 May 2010
Richards O Rao M Spencer-jones R
Full Access

Aim: To assess the outcome of knee arthrodesis using cemented Endo-Model knee fusion nail in failed total knee arthroplasty with significant bone loss due to infection.

Methods: A Retrospective case study of seven patients with infected TKR and multiple surgeries and significant bone loss (Type III AORI classification). All patients had antibiotic loaded cement with a temporary K-nail as a first stage procedure to eradicate infection. All seven patients had arthrodesis performed using cemented modular Endo-Model Knee Fusion nail (Waldemar Link, Hamburg) by senior author (RSJ). The arthrodesis relied on the strong coupling mechanism of the nail and not on bony union, providing pain relief while mainting leg length. Outcomes assessed using pre–and post Visual Analogue Score (VAS) and Oxford knee scores.

Results: Mean age 76.8 years (62–85). Mean follow up 23.7 months (3–42). The mean VAS pain score improved from 7.6 (6.5–8.5) pre-operatively to 1.1 (0–3.2) post-operatively. The mean post-operative Oxford score was 30.3 (27–36). One patient required revision for asceptic loosening. All but one of the patients thought that arthrodesis was preferable to amputation post-operatively.

Conclusion: The Endo-Model knee fusion nail has good early results in terms of pain relief and knee arthrodesis where there is significant bone loss and extensor mechanism insufficiency following an infected total knee replacement.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 78 - 78
1 Mar 2009
Gudena R Mehta J Morgan-Jones R
Full Access

Introduction: Sequential staged distraction with fixed rate and rhythm, alternative compression and distraction is well described in the literature to treat non-unions. However we looked the union in established non-unions of tibia using one stage distraction without further manipulation at the fracture site maintaining the stability.

Materials and Methods: 12 patients with established tibial non-unions were referred during the period of 2001–2005. 2 cases were infected non unions. All patients were symptomatic and exhibited deformity at the non-union site. Ten males, two females were in the study group with a mean age of 39.2 years. The location of non-union was distal 1/3 of tibia in 8 cases and 2 cases of proximal and middle 1/3. External fixation was used to acutely distract the fracture (one stage) and tension the soft tissues to attain fracture stability. Infection at the fracture site required further operative debridement. Regular followup with radiographs to assess the union.

Results: Osseous union was achieved in all the cases at an average time period of 17.2 weeks. There was no recurrence of osteomyelitis in the infected cases following secondary debridement. All the patients were pain free and fully mobile without aid at review.

Conclusion: We concluded that acute distraction osteogenesis produces fracture union in selected established cases of non union. This method can be used to obtain impressive gains in the lengths of the long bones. Bone is uniformly produced regardless of the location of the non union. This is more patient compliant, effective and relatively easy to perform.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 538 - 539
1 Aug 2008
Kaye M Howells K Skidmore S Warren R Warren P McGeoch C Gregson P Spencer-Jones R Graham N Richardson J Steele N White S
Full Access

Introduction: etiology of late infection after arthroplasty can be difficult to establish. Histology is the gold standard for infection in patients without inflammatory arthritis but diagnosis in inflammatory arthritis depends on culture (Atkins et al). Real-time PCR offers a rapid and direct assessment for staphylococci and enterococci infection but has not been widely assessed.

The aims of this study were

to develop the Roche lightcycler Staphylococcal and Enterococcal PCR kits to facilitate diagnosis of hip and knee prosthetic infections

To analyse results together with bacteriological and histological findings.

Methods: uplicate, multiple tissue samples were taken (with separate sterile instruments) at the 1st stage of revision after informed consent. One set were cultured and results interpreted by the Oxford criteria. The second set were extracted using the Qiagen DNA kit, purified (in-house method) and tested using the Roche lightcycler kits.

Results:53 patients undergoing 2 stage revision for suspected infection were recruited.15 (28.3%) had negative histology and no inflammatory arthritis; 3 with single positive cultures and negative PCR – considered contaminants.

29 patients had non-inflammatory arthritis. 14/18 (77.8%) with positive cultures had staphylococci +/or enterococci isolated and 10 PCR results correlated. The other 11 patients had negative cultures.

9 patients had inflammatory arthritis. Six were culture negative and of the other three, 2 were positive for staphylococci on culture with 1 positive by PCR.

Discussion: Negative staphylococcal PCR correlates with the isolation of staphylococci from only one sample. This agrees with the Oxford criteria that such samples may be considered contaminants. Additional positives detected by staphylococcal PCR alone are rare.

Enterococcal PCR confirmed culture positivity in 2/3 patients. An additional 5 positive PCR’s were obtained from patients’ culture negative for enterococci. It is not clear if these are false positives or more sensitive detection of enterococcal isolation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 323 - 323
1 Jul 2008
Khan W Jones R Nokes L Johnson D
Full Access

Introduction: In this study the optimal angle of fixation or splintage for partially weight bearing fractures of the patella was determined by a gait analysis measurement system.

Subjects and Methods: A knee brace was applied to eight subjects and locked at 0, 10, 20 and 30 degrees. Measurements were also taken for an unlocked brace and in the absence of a brace. The subjects were instructed on partial weight bearing mobilisation. Three dimensional motion analyses were performed using an infrared 8-camera system. The ground reaction force was recorded by two 3-dimensional force plates embedded in the walkway. Kinematic and kinetic data was collected and the data was transferred to a computer programme for further analysis and the forces acting on the patella were calculated.

Results: The results showed that the forces acting on the patella were directly proportional to the knee flexion angle. The results also showed that the knee flexion angle does not always correspond with the angle set at the knee brace; however they did exhibit a direct relationship.

Conclusion: Our findings show that, for partially weight bearing patella fractures, the optimum form of splintage corresponds with a low knee flexion angle.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 373 - 373
1 Jul 2008
Khan W Jones R Nokes L Johnson D
Full Access

Patella and extensor mechanism injuries are common injuries and are generally managed with some degree of immobilisation and partial weight bearing to facilitate healing. The aim of this project was to determine the type of immobilisation or splintage during partial weight bearing that results in minimal forces acting through the extensor mechanism.

Gait analysis studies were performed on eight healthy male subjects mobilising partially weight bearing. Measurements were taken for six types of immobilisation: locked at 0, 10, 20, 30 degrees and unlocked in an orthotic knee brace, and without a brace. The ground reaction force, knee joint angle and the knee flexion moment were measured using Qualisys Track Manager and Visual 3D Software. The extensor mechanism moment and the extensor mechanism force were calculated using static equilibrium equations and documented data. A one-way analysis of variance statistical test was performed to determine the statistical significance of the differences between the six types of immobilisation.

There was a direct relationship between the knee flex-ion angle and the extensor mechanism force. The extensor mechanism force at 0 degrees of immobilisation was significantly lower than that for 20 and 30 degrees (p< 0.05). The increase in the extensor mechanism moment arm with increasing knee flexion was not suf-ficient to offset the increase in the extensor mechanism force caused by the increase in the knee flexion moment. The results also showed that the knee flexion angle does not always correspond with the angle set at the knee brace; however they did exhibit a direct relationship.

These results have important implications for the management of patients with patella and extensor mechanism injuries. The results suggest that improvements in knee brace design to allow 0 degrees of knee flexion, rather than the 10 degrees as seen in this study, are likely to result in significantly reduced extensor mechanism tensile forces.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 322 - 322
1 May 2006
Malham G Varma D Jones R Williamson OD
Full Access

To investigate the diagnostic properties of magnetic resonance imaging (MRI) scans in detecting surgically verified disruptions of the cervical intervertebral disc and anterior (ALL) and posterior longitudinal (PLL) ligaments.

Data were extracted from the reports of cervical spine MRI scans of patients who subsequently underwent surgical stabilization for presumed instability following disco-ligamentous injuries of the cervical spine. The level and severity of disc, ALL and PLL disruption was compared with surgical findings. Unweighted kappa statistics were used to assess agreement. The sensitivity, specificity, positive (PPV) and negative (NPV) predictive values were calculated after findings where dichotomised into complete rupture, yes/no. Sensitivity analyses were performed to account for missing data.

The MRI and surgical findings were compared on 31 consecutive patients. The kappa values for intervertebral disc disruption, ALL and PLL disruption were 0.22, 0.25 and 0.31 respectively, indicating fair agreement. Sensitivity, specificity, PPV and NPV are shown in Table 1. The false negative rates for diagnosing complete disruption of the disc, ALL and PLL were 0.18, 0.40 and 0.14 respectively.

The ability of cervical MRI scans to detect surgically verified disruptions of the intervertebral disc, ALL and PLL varied depending on the structure examined. In this series, the cervical MRI scan reliably detected disruption of the intervertebral disc disruption and ALL. The false negative rates are of concern and indicate the need for additional investigations to exclude instability in the absence of negative MRI findings.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2005
DAY M MOHANTY K SPENCER-JONES R
Full Access

Revision hip surgery is becoming increasingly common, 300 procedures being performed in 2001 at our institution. In order to achieve a good outcome bone stock needs to be of good quantity frequently necessitating the use of impaction bone grafting using allograft bone.

Donor bone may frequently take three months before it becomes available for use due to the stringent screening procedure. Donor patients must have a clean bill of health, swabs taken at the time of surgery must obviously demonstrate no growth and blood samples taken at donation and an interval of three months, free from viral infectious diseases. It is thus easy to see the lag from the time of donation to availability and why, with increasing demand, need for allograft bone is rapidly exceeding supply.

We need to look for an alternative supply of human bone allograft.

We have compared the harvest of bone at the time of primary total knee replacement with that of the femoral head by both mass and volume. Sixty consecutive patients undergoing primary hip or knee arthroplasty were included in the study, and the masses and volume of the femoral heads compared with that of the total bone cuts in knee arthroplasty. The type of knee replacement used was documented as was whether the femoral head had had a bone block removed. It was found that the mass of femoral heads was 81g, that of knee cuts 95g this is a statistically significant difference; the volume of femoral heads 66ml and that of knee cuts 75ml.

The volumes of bone available from knee arthroplasty cuts are at least comparable femoral heads obtained using hip replacement and could, perhaps, provide a realistic source of bone allograft.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 209 - 209
1 Mar 2004
Kuiper J Rao C Graham N Gregson P Spencer-Jones R Richardson J
Full Access

Introduction: Impaction grafting has become a popular technique to revise implants. The Norwegian Arthroplasty Registry reports its use for a third of all revisions. Yet, the technique is seen as demanding. A particular challenge is to achieve sufficient mechanical stability of the construction. This work tests two hypotheses: (1) Graft compaction is an important determinant of mechanical stability, and (2) Graft compaction depends on compaction effort and graft properties. Methods: Impaction grafting surgery was simulated in laboratory experiments using artificial bones with realistic elastic properties (Sawbones, Malmö, Sweden). Bone stock was restored with compacted morsellised graft, and the joint reconstructed with a cemented implant. The implant was loaded cyclically and its migration relative to bone measured. In a second study, morsellised bone of various particle sizes and bone densities, with or without added ceramic bone substitutes, was compacted into a cylindrical mould by impaction of a plunger by a dropping weight. Plunger displacement was measured continuously. Results: Initial mechanical stability of the prostheses correlated most strongly with degree of graft compaction achieved. Graft compaction to similar strength was achieved with less energy for morsellised bone with larger particles, higher density, or bone mixed with ceramic substitutes. Conclusion: Initial mechanical stability of impaction-grafted joint reconstructions depends largely on degree of graft compaction achieved by the surgeon. Compaction depends partly on the vigour of impaction, and partly on graft quality. Higher bone density, larger particle size and mixing with ceramic particles all help to facilitate graft compaction, giving a stronger compacted mass with less effort.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 74 - 74
1 Jan 2004
Hart W Rees RJ Metcalfe J Spencer-Jones R
Full Access

Introduction: There are approximately 50000 hip and knee arthroplasties performed in the UK every year. With this increasing number the prevalence of periprosthetic fractures is also rising. These are often challenging problems with increased morbidity and mortality. The use of cortical strut allografts in periprosthetic fractures was first reported in the early 90’s with favourable results.The aim of this study was to assess the radiological outcome of cortical strut allografts used as the treatment for periprosthetic fractures of the femur in patients presenting to our institution.

Patients & Methods: 17 patients with who had received strut allografts as part of their treatment for a periprosthetic fracture of the femur were identified. 13 fractures were around a total hip replacement and 4 around other femoral implants (2 long stemmed TKR’s and 2 fracture fixation devices).

We undertook a radiological evaluation of this technique. We assessed fracture union and strut allograft incorporation using the radiological criteria of Emerson et al. The procedure was deemed a success if the fracture had united, with evidence of graft incorporation with a stable implant. We also undertook a notes review identifying any risk factors and any previous surgery.

Results: Two patients died in the early post-operative period. 15 patients were available for analysis. The average length of radiographic review was 16 months. 11/15 procedures (73%) were deemed a success. All these showed evidence of graft incorporation which was time dependent. There were four failures. In one patient the struts fractured at two months. There were three cases of deep sepsis, this required amputation in one and excision arthroplasty in two.

Conclusion: Cortical strut allografts are a good technique for the management of periprosthetic fractures of the femur. As well as providing initial support they also become incorporated which improves the host bone stock.