Abstract
To assess the outcome of knee “arthrodesis” using cemented Endo-Model knee fusion nail in failed Total Knee Replacement (TKR) with significant bone loss due to infection. This is a retrospective case study of seven patients with infected TKR and multiple surgeries with significant bone loss.
All patients had antibiotic loaded cement with a temporary K-nail as a first stage procedure to eradicate infection. All seven patients had “arthrodesis” performed using cemented modular Endo-Model Knee Fusion nail (Waldemar Link, Hamburg) by the senior author. Cement was used to hold the stems in the diaphyses and not used around the coupling mechanism. The “arthrodesis” relied entirely on the coupling mechanism which has been shown to have good axial and torsional rigidity by mechanical testing. Outcome was assessed using pre and post Visual Analogue Score (VAS).
Mean age was 72.3 years(62–86). Mean follow up was 39.6 months (7–68). The VAS pain score improved from pre-operative mean score of 7.9 to a postoperative score of 1.5. One patient suffered fracture of femoral cement mantle at 50 months who underwent a technically easy exchange revision. One patient had recurrent infection with distal femoral fracture at 36 months and was revised to distal femoral replacement.
The Endo-Model knee arthrodesis nail restores limb lengths, has good early results in terms of pain relief and provides a stable knee “arthrodesis” in cases where there is significant bone loss and extensor mechanism insufficiency following an infected TKR.
Correspondence should be addressed to Editorial Secretary Mr ML Costa or Assistant Editorial Secretary Mr B.J. Ollivere at BOA, 35–43 Lincoln’s Inn Fields, London WC2A 3PE, England; Email: mattcosta@hotmail.com or ben@ollivere.co.uk