header advert
Results 21 - 40 of 47
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 105 - 105
1 Feb 2020
Gabor J Tesoriero P Padilla J Schwarzkopf R Davidovitch R
Full Access

INTRODUCTION

Proponents of the THA anterior approach have advocated for the use of dedicated surgical tables similar to those used in lower extremity fracture care that allow for traction, rotation, and angulation of the limb during surgery. Some tables require a specially-trained assistant to manipulate the table, whereas some may be manipulated by the surgeon. The purpose of this study is to compare the clinical outcomes in patients who underwent THA through an anterior approach on an assistant-controlled (AC) versus a surgeon-controlled (SC) table.

METHODS

This is a retrospective study of 343 consecutive THA patients from January 2017 – October 2017. Surgical and clinical data included surgical time, LOS, presence of pain (groin, hip, or thigh pain) at latest follow-up, and revision for any reason. Immediate postoperative radiographs were compared with latest follow-up radiographs to assess for LLD, stem alignment, and stem subsidence.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 138 - 138
1 Feb 2020
Schwarzkopf R Chow J Burkhardt J Gittins M Kaper B Fabi D Hanson B Kopjar B
Full Access

Background

The JOURNEY™ II Cruciate-Retaining Total Knee System (JIICR) and the JOURNEY™ II Bi-Cruciate Stabilized Total Knee System (JIIBCS) (both, Smith & Nephew, Memphis, TN, USA) are used for the treatment of end-stage degenerative knee arthritis. Belonging to the JOURNEY family of knee implants, the relatively new devices are designed to provide guided motion. Studies suggest that long-term outcomes of robotic-assisted navigation in total knee arthroplasty (TKA) are superior to the classical approach. This is the first report describing early postoperative outcomes of the NAVIO® robotic-assisted surgical navigation using the JOURNEY™ II family of knee implants.

Materials & Methods

In this ongoing study, six investigational sites in the US prospectively enrolled 122 patients (122 TKAs, 64 JIIBCS and 58 JIICR). Patients underwent TKA using the NAVIO system (Figure 1), a next-generation semi-autonomous tool that uses handheld miniaturized robotic-assisted instrumentation that the surgeon manipulates in 6 degrees of freedom, but restricts cutting to within the confines of the pre-designated resection area of the patient's bone. The primary outcome was postoperative mechanical alignment on long leg X-ray at one month postoperative compared to operative target alignment. Alignment within ±3 degrees of the target alignment was considered a success.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 13 - 13
1 Oct 2019
Bedard NA DeMik DE Carender CN Browne JA Schwarzkopf R Callaghan JJ
Full Access

Introduction

In 2015, the healthcare system transitioned from International Classification of Diseases, Ninth Revision (ICD-9) coding to the Tenth Revision (ICD-10). Given that administrative claims are used for quality initiatives, risk adjustment models and clinical research, we sought to determine the effect of new, more detailed coding on the incidence of complications following primary total knee arthroplasty (TKA).

Methods

The Humana administrative claims database was queried from 2-years prior to October 1, 2015 (ICD-9 cohort) and for 1-year after this date (ICD-10 cohort) to identify all primary TKA procedures. Each TKA was then tracked for occurrence of an arthroplasty specific post-operative complication within 6 months of surgery using the respective coding systems. Laterality and joint specific codes were utilized for the ICD-10 cohort to ensure complications occurred on the same side and joint as the index procedure. Incidence of each complication was compared between cohorts using risk ratios (RR) and 95% confidence intervals.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 17 - 17
1 Oct 2019
Roof MA Adnan M Feng JE Anoushiravani AA Schoof LH Friedlander S Vigdorchik J Slover JD Schwarzkopf R
Full Access

Introduction

Previous studies have reported an increased risk for postoperative complications in the Medicaid population undergoing total hip arthroplasty (THA). These studies have focused on payer type and have not controlled for the surgeon's practice or patient care setting. This study aims to evaluate whether patient point of entry plays a role in quality outcomes and discharge disposition following THA.

Methods

The electronic medical record at our institution was retrospectively reviewed for all primary, elective, unilateral THA between January 2016 and June 2018. THA recipients were categorized as either Hospital Ambulatory Clinic Centers (HACC) with Medicaid as the primary payer or private office patients with a non-Medicaid primary payer based on a previous visit to our institution's HACC within the 6-months prior to surgery. Only patients who had been operated on by a surgeon with at least 10 HACC and 10 private office patients were included.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 73 - 73
1 Oct 2019
Sershon RA Fillingham Y Abdel MP Malkani AL Schwarzkopf R Padgett DE Vail TP Nam D Nahhas CR Culvern C Valle CJD
Full Access

Background

The purpose of this multicenter, randomized clinical trial was to determine the optimal dosing regimen of tranexamic acid (TXA) to minimize perioperative blood loss for revision total hip arthroplasty (THA).

Methods

Six centers prospectively randomized 155 revisions to one of four regimens: 1g of intravenous (IV) TXA prior to incision, a double dose regimen of 1g IV TXA prior to incision and 1g IV TXA during wound closure, a combination of 1g IV TXA prior to incision and 1g intraoperative topical TXA, or three doses of 1950mg oral TXA administered 2 hours preoperatively, 6 hours postoperatively, and on the morning of postoperative day one. Randomization was based upon revision subgroups to ensure equivalent group distribution, including: femur only, acetabulum only, both component, explant/spacer, and second stage reimplantation. Patients undergoing an isolated modular exchange were excluded. An a priori power analysis (alpha = 0.05; beta = 0.80) determined 40 patients per group were required to identify a 1g/dL difference in postoperative hemoglobin reduction between groups. Per-protocol analysis involved an analysis of variance, Fisher's exact tests, and two one-sided t-tests for equivalence.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 67 - 67
1 Oct 2019
Padilla JA Gabor JA Orio A Slover JD Schwarzkopf R Macaulay WB
Full Access

Introduction

Patients who undergo total joint arthroplasty (TJA) are at a high risk for the development of thromboembolic complications. The rate at which venous thromboembolism occurs following TJA has been reported to be between 1.3–9.4%. As a result, the utilization of prophylactic therapies is considered standard of care in this patient population. The primary purpose of the current study was to 1) evaluate patient satisfaction with the use of intermittent compression devices 2) evaluate the risk of self-reported falls secondary to the use of these devices following TJA.

Methods

This is a single institution, prospective study on patients who underwent TJA at an urban, academic orthopedic specialty hospital. Patients were surveyed using an electronic patient rehabilitation application regarding their use and satisfaction with their home intermittent compression devices with a battery and power cord attachment that the patient must wear while using the devices. They were also asked if any falls or near-falls they may have experienced. Surveys were administered on postoperative Day 14, and patients were given 10 days to submit their responses. Using our institutions data warehouse, patient demographics were also collected (Table 1).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 46 - 46
1 Oct 2019
Iorio R Feder O Schwarzkopf R Einhorn TA
Full Access

Introduction

Without intervention 80% of hips with osteonecrosis (ON) will progress. Core decompression has shown favorable results (60–80% survivorship) in early stage ON, and recently, bone marrow aspirate concentration (BMAC) injection into the decompressed femoral head has been proposed to stimulate healing of the necrotic lesion and improve outcomes and survivorship.

Methods

We retrospectively reviewed the clinical and radiographic outcomes of 42 hips in 26 patients who underwent core decompression with BMAC for ON with a minimum of 1 year follow up. We evaluated pre-op visual analog pain scores (VAS), Steinberg class based on radiographs, as well as Kerboul angle as measured on MRI. Clinical outcomes were reported as change in VAS at final follow up, advancement in Steinberg classification based on radiographs at final follow up, or decision to proceed with THA.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 69 - 69
1 Oct 2019
Macaulay W Feng JE Mahure S Waren D James S Long WJ Schwarzkopf R Davidovitch R
Full Access

Introduction

Total hip arthroplasty (THA) candidates have received high doses of opioids within the perioperative period for the management of surgical pain. Healthcare systems have responded by improving opioid administration documentation and are now implementing opioid-sparing protocols (OSP) into THA integrated care pathways (ICP). Here we evaluate the effectiveness of a novel OSP in primary THA at out institution.

Methods

Between January 2019 to April 2019, all patients undergoing primary THA were placed under a novel OSP (Table 1). Patient demographics, inpatient/surgical factors, and inpatient opiate administration events were collected. A historical 2:1 cohort was subsequently derived from patients undergoing THA between January 2018 to August 2018.

Opiate administration events collected from our EDW were converted into Morphine Milligram Equivalences (MMEs) and transformed into average MME's per patient per 24-hour interval. Nursing documented visual analog scale (VAS) pain scores were also queried and averaged per patient per 12-hour interval. To assess immediate postoperative functional status, the validated Activity Measure for Post-Acute Care (AM-PAC) Short Forms tool was utilized.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 40 - 40
1 Apr 2019
Vigdorchik J Cizmic Z Elbuluk A Jerabek SA Paprosky W Sculco PK Meere P Schwarzkopf R Mayman DJ
Full Access

Introduction

Computer-assisted hip navigation offers the potential for more accurate placement of hip components, which is important in avoiding dislocation, impingement, and edge-loading. The purpose of this study was to determine if the use of computer-assisted hip navigation reduced the rate of dislocation in patients undergoing revision THA.

Methods and Materials

We retrospectively reviewed 72 patients who underwent computer-navigated revision THA [Fig. 1] between January 2015 and December 2016. Demographic variables, indication for revision, type of procedure, and postoperative complications were collected for all patients. Clinical follow-up was performed at 3 months, 1 year, and 2 years. Dislocations were defined as any episode that required closed or open reduction or a revision arthroplasty. Data are presented as percentages and was analyzed using appropriate comparative statistical tests (z-tests and independent samples t- tests).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 97 - 97
1 Apr 2019
Vigdorchik J Cizmic Z Novikov D Meere PA Schwarzkopf R Buckland A
Full Access

Introduction

A comprehensive understanding of pelvic orientation prior to total hip arthroplasty is necessary to allow proper cup positioning and mitigate the risks of complications associated with component malpositioning. Measurements using anteroposterior (AP) radiographs have been described as effective means of accurately predicting pelvic orientation. The purpose of our study was to describe the inter- and intra-observer reliability and predictive accuracy of predicting pelvic tilt using AP radiographs.

Methods

Five fellowship-trained orthopaedic surgeons independently analyzed pelvic tilt, within 10 degrees, for 50 different AP pelvis radiographs. All surgeons were blinded to patient information, diagnosis, and correct measurements prior to analysis. Responses were then compared to correct measurements using sitting-standing AP and lateral stereoradiographs.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 58 - 58
1 Oct 2018
Feng JE Anoushiravani AA Waren D Hutzler L Iorio R Bosco J Schwarzkopf R Slover J
Full Access

Summary

Narcotic administration within the inpatient setting is highly variable any may benefit from the implementation of standardized multi-modal pain management protocols.

Introduction

Total joint arthroplasty (TJA) candidates have historically received high doses of opioids within the perioperative period for the management of surgical pain. Healthcare systems have responded by improving opioid prescribing documentation and implementing narcotic-sparing pain protocols into TJA integrate care pathways (ICP). Despite these efforts, there are few technological platforms designed to curtail excessive inpatient narcotic administration. Here we present an early iteration of an inpatient narcotic administration reporting tool which normalizes patient narcotic consumption as an average daily morphine milligram equivalence (MME) per surgical encounter (MME/day/encounter) among total hip arthroplasty (THA) recipients. This information may help orthopaedic surgeons visualize their individual granular inpatient narcotic prescribing habits individually and compared to other surgeons, while taking into consideration patient and procedure specific variables.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 53 - 53
1 Oct 2018
Walker PS Einhorn T Schwarzkopf R Hooper J Werner J Fernandez E
Full Access

Introduction

In major orthopaedic departments, typically several total knee systems are used. Each system requires several sets of instruments, each set with many trays of complicated and expensive parts. The logistics and costs of maintainance are considerable. Our overall goal is to investigate the feasibility of autoclavable single-use 3D printed instruments made from a polymeric material, used for any type of total knee design. The procedure will be standardized and adjustments easy to implement. Each set will be packaged individually, and used for a single case. There are many aspects to this study; in this part, the aims are to identify suitable materials for autoclavability and strength, and then to compare the accuracy of a novel design of 3D printed tibial cutting guide with a current metallic guide.

Methods

Test samples were designed to simulate shapes in current instruments, such as mating pegs and holes, threaded screws, and slotted blocks. Each set was produced in biocompatible materials, ABS-M30i, VeroClear (MED610), Ultem1010, and Nylon 12. Each part was laser scanned, and then imaged virtually using a reverse engineering software (GeoMagic). Manual measurements of key dimensions were also made using calipers. The parts were autoclaved using a standardized protocol, 30 minutes at 250° F. All parts were re-scanned and measured to determine any changes in dimensions. To test for strength and abrasion resistance, the slotted blocks were pinned to sawbones model tibias, and an oscillating saw used to cut through the slot. A compact 3D printed tibial cutting guide was then designed which fitted to the proximal tibia and allowed varus-valgus, tibial slope and height adjustments. A small laser attached to the guide projected to a target at the ankle. Tests were made on 20 sawbones, and compared with 20 with a standard metal cutting guide. Digitization was used to measure the angles of the cuts.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 33 - 33
1 Oct 2018
Iorio R Aggarwal V Stachel A Phillips M Schwarzkopf R Vigdorchik JM Bosco JA Long WJ
Full Access

Introduction

There has been a renewed interest in the surgical approach used for total hip arthroplasty (THA). Risk factors for periprosthetic joint infection (PJI) have been well studied over the past decade, yet PJI remains one of the most devastating complications following THA. We studied the impact of direct anterior (DA) versus non-direct anterior (NA) surgical approaches on PJI, and examined the impact of new perioperative protocols on PJI rates following all surgical approaches at a single institution.

Methods

6086 continuous patients undergoing primary THA at a single institution from 2013–2016 were retrospectively evaluated. Data obtained from electronic patient medical records included age, sex, body mass index (BMI), medical comorbidities, surgical approach, and presence of deep PJI. Deep PJI was defined according to National Healthcare Safety Network's (NHSN) criteria for joint space infection following prosthetic hip replacement. Infection rates were calculated yearly for the DA and NA approach groups. Covariates were assessed and used in multivariate analysis to calculate adjusted odds ratios for risk of development of PJI with DA compared to NA approaches. In order to determine the effect of adopting a set of infection prevention protocols and patient optimization on PJI, we calculated odds ratios for PJI comparing patients undergoing THA for two distinct time periods: 2013–2014 and 2015–2016. These periods corresponded to before and after we implemented a set of perioperative infection protocols.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 66 - 66
1 Oct 2018
Vigdorchik JM Novikov D Abdel MP Mercuri J Long WJ Bosco J Schwarzkopf R
Full Access

Introduction

Complications can be defined as preventable, potentially preventable, or non-preventable. While often discussed, there are virtually no data whether or not the most common causes of revision total hip arthroplasty (THA) are preventable or not. The goal of this study was to identify and report preventable causes of revision THA within 5 years of the index THA.

Methods

We conducted a retrospective review of 128 consecutive revision THAs between August 2015 and August 2017, with 62% being referred from another institution. Mean time to revision THA from the index arthroplasty was 10 months. Mean age at revision THA was 61 years, with 67% being female. Three fellowship-trained adult reconstruction surgeons reviewed the radiographs and operative notes and classified the revision THAs into two categories: preventable vs. non-preventable. Reviewers were instructed to be extremely lenient with the benefit of the doubt given to the operative surgeon. Inter-observer reliability was assessed by Cohen's kappa analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 63 - 63
1 Oct 2018
Bedair H Schurko B Dwyer M Novikov D Anoushiravani AA Schwarzkopf R
Full Access

Introduction

Interferon (IFN) based treatments for chronic hepatitis C (HCV) have been the standard of care until 2014 when direct antiviral agents (DAA) were introduced. Patients with HCV have had extremely high complication rates after total hip arthroplasty (THA). It is unknown whether HCV is a modifiable risk factor for these complications prior to THA. The purpose of this study was 1) to compare perioperative complication rates between untreated and treated HCV in THA and 2) to compare these rates between patients treated with two different therapies (IFN vs. DAA).

Methods

A multicenter retrospective database query was used to identify patients diagnosed with chronic hepatitis C virus who underwent total hip arthroplasty from 2006–2016. All patients (n=105) identified were included and were divided into two groups: untreated HCV (n=63) and treated (n=42); the treated group were further subdivided into those receiving IFN based therapies (n=16) or DAA therapies (n=26). Comparisons between the treated and untreated groups were made with respect to demographic data, comorbidities, preoperative viral load, MELD score, and all surgical (≤1 yr) and medical (≤90d) complications; a sub-group analysis of the treated patients was also performed. Separate independent t-tests were conducted for dependent variables that were normally distributed, and Mann-Whitney U tests were conducted for variables which were not normally distributed. Categorical variables were compared through the chi-square test of independence. The level of statistical significance was set at p<0.05.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 8 - 8
1 Oct 2018
Feng JE Anoushiravani AA Waren D Hutzler L Bosco JA Schwarzkopf R Slover J
Full Access

Summary

Despite adoption of robust clinical pathways, narcotic administration within the inpatient setting is highly variable and may benefit from the implementation of standardized multi-modal pain management protocols.

Introduction

Total knee arthroplasty (TKA) candidates have historically received high doses of opioids within the perioperative period for the management of surgical pain. Healthcare systems have responded by improving opioid prescribing documentation and implementing narcotic-sparing pain protocols into TKA integrated care pathways (ICP). Despite these efforts, there are few technological platforms specifically designed to measure the narcotic burden immediately postoperatively. Here we present an early iteration of an inpatient narcotic administration-reporting tool, which normalizes patient narcotic consumption as an average daily morphine-milligram-equivalence (MME) per surgical encounter (MME/day/encounter) among total knee arthroplasty (TKA) recipients. This information may help orthopaedic surgeons visualize their individual granular inpatient narcotic prescribing habits individually and compared to other surgeons, while taking into consideration patient and procedure specific variables in order to optimize use and curtail unnecessary narcotic prescriptions.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2018
Fillingham YA Darrith B Calkins T Abdel MP Malkani AL Schwarzkopf R Padgett DE Sershon RA Bini S Della Valle CJ
Full Access

Introduction

Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA that is associated with greater blood loss. The purpose of this multi-center randomized trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA.

Methods

233 Septic and aseptic revision TKA from six-centers were randomized to either receive 1g pre-incision intravenous (IV) TXA, 1g pre- and post-incision IV TXA, 1g pre-incision IV and 1g intra-operative topical TXA, or three doses of 1950mg oral TXA given 2 hours pre-operatively, 6 hours post-operatively, and the morning of postoperative day 1. Randomization was performed based on type of revision to ensure equivalent distribution among groups. The primary outcome was reduction in hemoglobin. Power analysis determined 40 patients per group were necessary to identify a 1g/dL difference with an alpha of 0.05 and beta of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 117 - 117
1 Mar 2017
Yu S Bolz N Buza J Saleh H Murphy H Rathod P Iorio R Schwarzkopf R Deshmukh A
Full Access

Introduction

Revision Total Knee Arthroplasty (TKA) is becoming increasingly prevalent as the number of TKA procedures grow in a younger, higher-demand population. Factors associated with patients requiring multiple revision TKAs are not yet well understood. The purpose of this study is to investigate the epidemiology of re-revision TKA, and identify risk factors that are associated with failure of re-revision TKA.

Methods

A retrospective analysis was performed on 358 patients who underwent revision TKA at a single institution between 1/2012 and 12/2013. Patients who underwent revision knee arthroplasty two or more times were included. Patients were excluded if their indication for the first revision was periprosthetic joint infection (PJI). Patient demographics, surgical indications, revision details, and available follow-up information were collected. Re-revision failure was defined as the need for any additional operative intervention. A logistic regression analysis was performed to assess for significant predictors of re-revision failure.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 20 - 20
1 Mar 2017
Milone M Vigdorchik J Schwarzkopf R Jerabek S
Full Access

INTRODUCTION

Acetabular cup malpositioning has been implicated in instability and wear-related complications after total hip arthroplasty. Although computer navigation and robotic assistance have been shown to improve the precision of implant placement, most surgeons use mechanical and visual guides to place acetabular components. Authors have shown that, when using a bean bag positioner, mechanical guides are misleading as they are unable to account for the variability in pelvic orientation during positioning and surgery. However, more rigid patient positioning devices may allow for more accurate free hand cup placement. To our knowledge, no study has assessed the ability of rigid devices to afford surgeons with ideal pelvic positioning throughout surgery. The purpose of this study is to utilize robotic-arm assisted computer navigation to assess the reliability of pelvic position in total hip arthroplasty performed on patients positioned with rigid positioning devices.

METHODS

100 hips (94 patients) prospectively underwent total hip Makoplasty in the lateral decubitus position from the posterior approach; 77 stabilized by universal lateral positioner, and 23 by peg board. After dislocation but prior to reaming, one fellowship trained arthroplasty surgeon manually placed the robotic arm parallel to both the longitudinal axis of the patient and the horizontal surface of the operating table, which, if the pelvis were oriented perfectly, would represent 0 degrees of anteversion and 0 degrees of inclination. The CT-templated computer software then generated true values of this perceived zero degrees of anteversion and inclination based on the position of the robot arm registered to a preoperative pelvic CT. Therefore, variations in pelvic positioning are represented by these robotic navigation generated values. To assure the accuracy of robotic measurements, cup anteversion and inclination at times of impaction were recorded and compared to those calculated via the trigonometric ellipse method of Lewinnek on standardized 3 months postoperative X-rays.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 140 - 140
1 Mar 2017
Laster S Schwarzkopf R Sheth N Lenz N
Full Access

Background

Total knee arthroplasty (TKA) surgical techniques attempt to achieve equal flexion and extension gaps to produce a well-balanced knee, but unexplainable unhappy patients persist. Mid-flexion instability is one proposed cause of unhappy patients. There are multiple techniques to achieve equal flexion and extension gaps, but their effects in mid-flexion are largely unknown.

Purpose of study

The purpose of the study is to determine the effects that changing femur implant size and/or adjusting the femur and tibia proximal -distal and femur anterior-posterior implant positions have on cruciate retaining (CR) TKA mid-flexion ligament balance when equal flexion and extension gaps are maintained.