Systemic metal ion monitoring (Co;Cr) has proven to be a useful screening tool for implant performance to detect failure at an early stage in metal-on-metal hip arthroplasty. Several clinical studies have reported elevated metal ion levels after total knee arthroplasty (TKA), with fairly high levels associated with rotating hinge knees (RHK) and megaprostheses1. In a knee simulator study, Kretzer2, demonstrated volumetric wear and corrosion of metallic surfaces. However, prospective in vivo data are scarce, resulting in a lack of knowledge of how levels evolve over time. The goal of this study was to measure serum Co and Cr levels in several types TKA patients prospectively, evaluate the evolution in time and investigate whether elevated levels could be used as an indicator for implant failure. The study was conducted at Ghent University hospital. 130 patients undergoing knee arthroplasty were included in the study, 35 patients were lost due to logistic problems. 95 patients with 124 knee prostheses had received either a TKA (primary or revision) (69 in 55 patients), a unicompartimental knee arthroplasty (7 UKA), a RHK (revision −7 in 6 patients) or a megaprosthesis (malignant bone tumours − 28 in 27 patients) (Fig 1). The TKA, UKA and RHK groups were followed prospectively, with serum Co and Cr ions measured preoperatively, at 3,6 and 12 months postoperatively. In patients with a megaprosthesis, metal ions were measured at follow-up (cross-sectional study design).Introduction
Patients and Methods
To determine the mechanisms and extents of popliteus impingements before and after TKA and to investigate the influence of implant sizing. The hypotheses were that (i) popliteus impingements after TKA may occur at both the tibia and the femur and (ii) even with an apparently well-sized prosthesis, popliteal tracking during knee flexion is modified compared to the preoperative situation. The location of the popliteus in three cadaver knees was measured using computed tomography (CT), before and after implantation of plastic TKA replicas, by injecting the tendon with radiopaque liquid. The pre- and post-operative positions of the popliteus were compared from full extension to deep flexion using normosized, oversized and undersized implants (one size increments). At the tibia, TKA caused the popliteus to translate posteriorly, mostly in full extension: 4.1mm for normosized implants, and 15.8mm with oversized implants, but no translations were observed when using undersized implants. At the femur, TKA caused the popliteus to translate laterally at deeper flexion angles, peaking between 80º-120º: 2.0 mm for normosized implants and 2.6 mm with oversized implants. Three-dimensional analysis revealed prosthetic overhang at the postero-superior corner of normosized and oversized femoral components (respectively, up to 2.9 mm and 6.6 mm). A well-sized tibial component modifies popliteal tracking, while an undersized tibial component maintains more physiologic patterns. Oversizing shifts the popliteus considerably throughout the full arc of motion. This study suggests that both femoro- and tibio-popliteus impingements could play a role in residual pain and stiffness after TKA.
Systemic metal ion monitoring (Co;Cr) has proven to be a useful screening tool for implant performance to detect failure at an early stage in metal-on-metal hip arthroplasty. Several clinical studies have reported elevated metal ion levels after total knee arthroplasty (TKA), with fairly high levels associated with rotating hinge knees (RHK) and megaprostheses1. In a knee simulator study, Kretzer2, demonstrated volumetric wear and corrosion of metallic surfaces. However, prospective in vivo data are scarce, resulting in a lack of knowledge of how levels evolve over time. The goal of this study was to measure serum Co and Cr levels in several types TKA patients prospectively, evaluate the evolution in time and investigate whether elevated levels could be used as an indicator for implant failure. The study was conducted at Ghent University hospital. 130 patients undergoing knee arthroplasty were included in the study, 35 patients were lost due to logistic problems. 95 patients with 124 knee prostheses had received either a TKA (primary or revision) (69 in 55 patients), a unicompartimental knee arthroplasty (7 UKA), a RHK (revision −7 in 6 patients) or a megaprosthesis (malignant bone tumours − 28 in 27 patients). The TKA, UKA and RHK groups were followed prospectively, with serum Co and Cr ions measured preoperatively, at 3,6 and 12 months postoperatively. In patients with a megaprosthesis, metal ions were measured at follow-up (cross-sectional study design). In primary knees, we did not observe an increase in serum metal ion levels at 3, 6 or 12 months. Two patients with a hip arthroplasty had elevated preTKA Co and Cr levels. There was no difference between unilateral and bilateral knee prostheses. In the revision group, elevated pre-revision levels were found in 2 failures for implant loosening. In both cases, ion levels decreased postoperatively. In revisions with a standard TKA, there was no significant increase in metal ions compared to primary knee arthroplasty. RHK were associated with a significant increase in Co levels even at short-term (3–12 months). The megaprosthesis group had the highest metal ion levels and showed a significant increase in Co and Cr with time in patients followed prospectively. With the current data, we could not demonstrate a correlation between metal ion levels, size of the implant or length of time in situ. In primary knee arthroplasty with a standard TKA or UKA, metal ion levels were not elevated till one year postoperatively. This suggests a different mechanism of metal ion release in comparison to metal-on-metal hip arthroplasties. In two cases of revision for implant loosening, pre-revision levels were elevated, possibly associated with component wear, and decreased after revision. With RHK, slightly elevated ion levels were found prospectively. Megaprostheses had significantly elevated Co and Cr levels, due to corrosion of large metallic surfaces and/or wear of components which were not perfectly aligned during difficult reconstruction after tumour resection. Further research is needed to assess the clinical relevance of metal ion levels in knee arthroplasty.
Failure of the polyethylene glenoid component is the most common complication of Total Shoulder Arthroplasty (TSA) and accounts for a majority of the unsatisfactory results after this procedure. Nowadays, most of the shoulder prostheses consist of metal on polyethylene bearing components. Repetitive contact between the metal ball and the polyethylene socket produces progressive abrasion of the implant if the moving part is made of polyethylene. Its debris may then lead to an active osteolysis and implant loosening. Failure of the glenoid component is often manifested clinically by pain, loss of function, and the presence of a clunking noise and leads to revision surgery. The use of ceramic balls aims at the reduction of this phenomenon. In many studies regarding knee and hip replacement it has been shown that the use of ceramic on polyethylene (CoP) is more beneficial in terms of polyethylene wear and failure, when compared to metal on polyethylene (MoP). Since a human shoulder is very different from a hip and a knee, it is not a self-centering, neither congruent joint. And its stability is provided by healthy muscles of the rotator cuff. We decided to compare CoP against MoP in semi- force controlled test setup. Where, for a given governing angular motion the translational motion was a function of contact (frictional) forces between the tested couple (humeral head and PE). This is to our knowledge the first study to address in direct comparison wear in TSA in semi force controlled test setup. Up today, there is no test standard for wear testing of TSA. A customised joint simulator was used to create worst-case scenario motion allowing for simulation of the muscles in two perpendicular axes: inferior – superior (I-S) and anterior – posterior (A-P). Were a governing angular motion (GAM) was the abduction – adduction (±30°) in I-S. A system of springs was created so that the I-S translation and the A-P rotation were a result of the GAM. The stiffens of the springs was tuned based on the MoP pair initial kinematic (1000 cycles) to result in: about 2mm I-S translation, and about ±10° A-P rotation. All samples were tested at the same test station in order to obtain maximal repeatability. Axial load was in range of 100N to 750 N. Three articulating couples for each material were tested for total of 2M cycles. Standard midterm gravimetric measurements were conducted at each 0.5 M cycles.Introduction
Materials and methods
External rotation of the femoral component is one factor that favors a satisfactory clinical result. New technologies have been developed to precisely implant the components of a total knee arthroplasty, including computer-assisted surgery (CAS) and patient-specific instruments (PSIs). The aim of this study was to compare the precision of CAS and PSIs when determining the orientation of the femoral component. A total of 65 patients operated on in 2008 with CAS had pre- and post-operative computed tomography (CT) in which the posterior condylar angle (PCA) was measured. The same pre- and post-operative measurements were performed for 27 patients operated on in 2010 with the assistance of PSI. For both populations, the antero-posterior femoral cuts were directed to implant the femoral component 3° of external rotation from the pre-operative posterior condylar line (PCL).Purpose
Methods
(1) to investigate the relationships between the bony contours of the knee and the Popliteus Tendon (PT) in the healthy knee and after implantation of a TKA and (2) to analyze the influence of implant sizing. With an apparently well-sized TKA, the position of the PT during knee flexion is modified compared with the preoperative situation.Goals of the study
Hypothesis
Obesity is known to influence surgical risk in total hip replacement (THR), with increased Body Mass Index (BMI) leading to elevated risk of complications and poorer outcome scores. Using a multinational trial data of a single implant, we assess the impact of BMI and regional variations on Harris Hip scores (HHS). We assessed BMI in 11 regional centres and associations with HHS at one year. Data were collected from 744 patients prospectively from 11 centres in the UK, Germany, Switzerland, Austria, New Zealand and Netherlands as part of a multicentre outcome trial. All Arthroplasties used RM Pressfit vitamys components (Mathys, Switzerland). Demographic, operative data and HHS were analysed with General Linear Model Anova, Minitab 16 (Minitab Inc, Pennsylvania).Introduction
Method
Fractures are the second commonest presentation of non-accidental injury (NAI) in children. Approximately one third of abused children will present to Acute Trauma Services (ATS) with fractures. Any cases of suspected child maltreatment should be referred to Safeguarding Services for follow-up, as outlined by Trust Guidelines. Our aim was to examine the referral of children with suspicious fractures to safeguarding and assess if cases with high risk of abuse are being missed by ATS. A comprehensive literature review identified commonly cited indicators of abuse. Inclusion criteria included age less than 18 months seen in A&E or Fracture Clinic with a long bone fracture. Patient notes were analysed to identify occurrence of these risk factors and findings cross-referenced with Safeguarding Services' records to verify whether high-risk patients were detected. The origin of each referral was also noted.Aim
Method
Assessment for and treatment of osteoporosis is recommended following hip fracture. All forms of osteoporosis treatment require an adequate calcium intake and normal vitamin D levels. This study assesses vitamin D levels in patients with hip fractures and describes guidelines on how to manage low vitamin D levels with high dose oral vitamin D3 (cholecalciferol). Circulating 25-hydroxyvitamin D levels were measured in consecutive patients with a hip fracture over an 18 month period. Substitution therapy with high dose oral cholecalciferol was started in 2 selected cohorts; one group received substitution therapy for 3 days, the second group for 7 days.Introduction
Materials and methods
compare the radiological results in sagittal balance correction obtained with pedicle subtraction osteotomy (PSO) versus anterior-posterior osteotomy (APO) by double approach in adults. between January of 2001 and July of 2009, fifty-eight vertebral osteotomies were carried out in fifty-six patients: 9 Smith-Petersen osteotomy (SPO), one vertebral resection osteotomy (VRO), 30 anterior-posterior osteotomies (APO) and 18 pedicle subtraction osteotomies (PSO), being the lasts two groups the sample studied (48 osteotomies). The mean age of the patients was 56.3 years (17–72). Initial diagnose was: 28 posttraumathic kyphosis, 7 postsurgical kyphosis, 7 adult degenerative disease, 4 ankylosing spondylitis and 2 congenital kyphoscoliosis. We evaluated the preoperative standing radiographs, the postoperative and at final follow-up by digital measurements with iPACS system viewer (© Real Time Image, USA, 2001). The mean follow-up was 54 months (6–98), and complications were analized.Purpose
Material and Methods
Despite proven advantages, pulsatile lavage seems to be used infrequently during preparation in cemented total knee arthroplasty. This remains irritating, as the technique has been suggested to improve radiological survival in cemented TKA, where aseptic loosening of the tibial component represents the main reason for revision. Furthermore, there may be a potential improvement of fixation strength for the tibial tray achieved by increased cement penetration. In this study, the influence of pulsed lavage on mechanical stability of the tibial component and bone cement penetration was analyzed in a cadaveric setting. Six pairs of cadaveric, proximal tibia specimen underwent computed tomography (CT) for assessment of bone mineral density (BMD) and exclusion of osseous lesions. Following surgical preparation, in one side of a pair, the tibial surface was irrigated using 1800ml normal saline and pulsatile lavage, while in the other side syringe lavage using the identical amount of fluid was applied. After careful drying, bone cement was hand-pressurized on the bone surface, tibial components were inserted and impacted in an identical way. After curing of cement, specimen underwent a postimplantation CT analysis). Cement distrubution was then assessed using a three-dimenionsional visualization software. Trabecular bone, cement and implant were segmented based on an automatic thresholding algorithm, which had been validated in a previous study. This allowed to determine median cement penetration for the entire cemented area. Furthermore, fixation strength of the tibial trays was determined by a vertical pull-out test using a servohydraulic material testing machine. Testing was performed under displacement control at a rate of 0,5mm/sec until implant failure. Data was described by median and range. Results were compared by a Wilcoxon matched pairs signed rank test with a type 1 error probability of 5 %. Median pull-out forces in the pulsed lavage group were 1275N (range 864–1391) and 568N (range 243–683) in the syringe lavage group (p=0.031). Cement penetration was likewise increased (p=0.031) in the pulsed lavage group (1.32mm; range 0.86–1.94), when compared to the syringe irrigated group (0.79mm; range 0.51–1.66). Failure occurred in the pulsatile lavage group at the implant-cement interface and in the syringe lavage group at the bone-cement interface, which indicates the weakness of the latter. Altogether, improved mechanical stability of the tibial implant and likewise increased bone cement interdigitation could be demonstrated in the current study, when pulsed lavage is implemented. Enhanced fixation strength was suggested being a key to improved survival of the implant. If this is the case, pulsatile lavage should be considered being a mandatory preparation step when cementing tibial components in TKA.
To document the success rate of closed reduction and soft tissue release in the treatment of bilateral true dislocation in developmental dysplasia of the hip (DDH). Case-note review of 22 children (44 hips) with idiopathic bilateral hip dislocation referred to a tertiary centre before walking age. The management protocol was as follows:
Examination under general anaesthesia, arthrogram, closed reduction and appropriate soft tissue release (adductors/psoas), application of a ‘frog’ cast. CT scan at 2 weeks to confirm reduction. Change of cast and arthrogram at 6 weeks to confirm improving position and stability. Cast removal at 12 weeks, and application of an abduction brace for 6 weeks. Treatment failure could occur on day 1 (failure of reduction), at week 2 (failure to maintain reduction), at week 6, or after cast removal.Purpose
Methods
To document the incidence and nature of complications associated with hemiepiphysiodesis using a screw and plate device (8-plate, Orthofix). We reviewed case notes and radiographs of 71 children (130 segments) with lower limb deformities treated with temporary hemiepiphyseal arrest using the 8-plate. 96% of deformities were in the coronal plane, 4% sagittal. 72% of coronal deformities demonstrated valgus malalignment. We defined three types of complications: complications Complications were related to variables of patient age, gender, diagnosis, location of deformity and associated surgery.Purpose
Methods
Sleep disturbance is frequently reported by people with chronic low back pain (CLBP >12 weeks), but there is limited knowledge of their sleep quality compared to healthy people. While disturbed sleep influences patients' mood, quality of life and recovery, few studies have comprehensively investigated sleep in CLBP. This study investigated differences in sleep profiles of people with CLBP, compared to age- and gender matched controls over seven consecutive nights. Thirty-two consenting subjects (n=16 with CLBP, n=16 matched controls), aged 24-65 years (43.8% male) underwent an interview regarding sleep influencing variables (e.g. mattress firmness, caffeine consumption), completed the Pittsburgh Sleep Quality Index (PSQI), Insomnia Severity Index (ISI), Pittsburgh Sleep Diary, SF36-v2, Hospital Anxiety and Depression Scale, and CLBP measures (i.e. Oswestry Disability Index and Numerical Pain Scales), recorded seven consecutive nights of sleep in their home using actigraphy, and completed a Devices Utility Questionnaire.Background and purpose
Methods
Cadeveric studies showed that single bundle ACL reconstructions were successful in limiting anterior tibial translation but were insufficient to control a combined rotatory load of internal and valgus torque. One possible cause of these condition could be that current single bundle procedures cannot realistically reproduce the complex anatomy of the ACL, especially the different function of its anteromedial(AM)and posterolateral(PL)bundle. The hypothesis of our study is that the addition of the PL bundle to the AM bundle, in an “in vivo” double bundle computer assisted ACL reconstruction, is actually able to reduce the internal rotation of the tibia at 30° degrees of knee flexion. Computer assisted ACL reconstruction has been used because it could be very effective in evaluating the global performance of the reconstructed knee. Ten consecutive doble bundle ACL reconstructions were performed in our Hospital using hamstrings graft and the 2.0OrthoPilot-B. Braun-Aesculap ACLnavigation system. The average age of patients was 27.8 years. The double-looped semitendinosus tendon replicating the AM bundle was fixed first at 60° of knee flexion. Than the gracilis tendon replicating the PL bundle was fixed at 15° of knee flexion. Maximum manual A–P displacement at 30° of flexion, maximum internal and external rotation of the knee were evaluated using the navigation system before surgery and after single(A–M)and double (AM+PL)bundle reconstruction. Statystical anlisys was done using paired T-test. Before ACL reconstruction mean manual maximum AP displacement was 17.2mm;mean manual maximum internal rotation was 19.8mm and mean manual maximum external rotation was 16.8mm. After AM bundle reconstruction mean manual maximum AP displacement was 6.1mm;mean manual maximum internal rotation was 17.0mm and mean manual maximum external rotation was 16.3mm. After AM+PL bundles reconstruction mean manual maximum AP displacement was 5.3mm;mean manual maximum internal rotation was 16.2mm and mean manual maximum external rotation was 14.6mm. There was no statistically significant difference in the tibial internal rotation at 30° after single bundle(AM)and double bundle(AM+PL)reconstruction. In this study the effectiveness of the PL bundle in controlling the internal rotation of the tibia, responsible of rotational instability of the knee, was evaluated in “in vivo” ACL reconstruction. The navigator system allowed us to obtain “in vivo” the real and correct value of AP displacement and internal and external rotation of the tibia before and after reconstruction. Our hypothesis that the addition of the PL bundle to the AM bundle is actually able to reduce the internal rotation of the tibia at 30° degrees of knee flexion, minimizing the pivot shift phenomenon, on the basis of our study has not been confirmed.
The aim of this study was to determine if the exposure to patient and surgeon was decreased with use of the mini C arm.