The use of MCL “pie-crusting” (selective release of the superficial MCL) to improve arthroscopic access to the posteromedial compartment of the knee for isolated meniscal surgery has been demonstrated. However, there are concerns that MCL pie-crusting with concomitant ACL reconstruction (ACLR) might affect knee stability and outcomes postoperatively. The aim of this study was to compare the functional outcomes between patients who underwent MCL pie-crusting at ACLR with those that did not. We performed a retrospective review of prospectively collected data from on the National Ligament Registry. 55 patients (33 male and 22 female) who had MCL pie-crusting(PC group) to address a meniscal lesion at the time of ACLR were compared with 65 patients (38 male and 27 female) who underwent isolated primary ACLR. All procedures were performed by a single surgeon at a tertiary centre between October 2013 and March 2019.Abstract
Introduction
Methods
Patella Baja is a known complication of TKR. In this study, we report the effect of the senior author's change of practice from total excision to minimal resection of Hoffa's fat pad on patellar height. Retrospective analysis of a prospective series of TKRs performed or directly supervised by the senior author. Group 1 included 72 patients performed before April 2011 who had complete excision of Hoffa's fat pad to improve exposure during their TKR procedures. Group 2 included 138 patients performed after April 2011 who had the minimum excision of Hoffa's fat pad to allow exposure. There were no other changes in surgical technique, implant choice or rehabilitation protocol during this time. Patellar height was measured using the Caton–Deschamps Index (CDI) on standard lateral radiographs immediately postoperative and at a minimum follow up of 1 year.Abstract
Introduction
Methods
In revision knee arthroplasty, rotating hinge implants (RHK) have been considered to result in higher complication rates and lower survivorship when compared to constrained condylar implants (CCK). The aims of this study were to compare patient reported outcome measures (PROMs), complication rates and survivorship of RHK and CCK used in revision arthroplasty at a single, high volume elective orthopaedic centre with previously validated bespoke database. One hundred and eight patients who underwent revision knee arthroplasty with either CCK or RHK and matched our inclusion criteria were identified. EQ5D, Health State and Oxford Knee Scores were collected pre-operatively and at 1 year post-operatively. Complication data was collected at 6 weeks, 6 months, 1 year and 2 years post-operatively. NJR data was interrogated, in addition to our own database, to investigate implant survival.Abstract
Introduction
Methodology
The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up. This was a multicentre registry study from October 2016 to June 2021 that included 861 primary RA-TKA patients who completed at least one pre- and postoperative patient-reported outcome measure (PROM) questionnaire, including Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR), and pain out of 100 points. The mean age was 67 years (35 to 86), 452 were male (53%), mean BMI was 31.5 kg/m2 (19 to 58), and 553 (64%) cemented and 308 (36%) cementless implants.Aims
Methods
We present a case series of patients that underwent knee ligament reconstruction with graft reinforcement using FibreTape (Arthrex), a 2mm wide non-biodegradable polyethylene tape. Outcomes and safety of this novel technique are reported. Data were collected from a prospectively maintained database from 03/2011 to 11/2019. All skeletally mature patients that underwent reinforced knee ligament reconstruction surgery at Basingstoke and North Hampshire Hospital were included. The cohort was interrogated for outcomes including failure, complications, and subjective patient reported outcomes at 6,12 and 24 months postoperatively.Abstract
Introduction
Methods
MCL injuries often occur concurrently with ACL rupture – most noncontact ACL injuries occur in valgus and external rotation (ER) - and conservative MCL treatment leads to increased rate of ACL reconstruction failure. There has been little work developing effective MCL reconstructions. Cadaveric work measured MCL attachments by digitisation and radiographically, relating them to anatomical landmarks. The isometry of the superficial and deep MCL (sMCL and dMCL) and posterior oblique ligament (POL) was measured using fine sutures led to displacement transducers. Contributions to stability (restraint) were measured in a robotic testing system. Two MCL reconstructions were designed and tested: 3-strand reconstruction (sMCL+dMCL+POL), and 2-strand method (sMCL+dMCL) addressing anteromedial rotatory instability (AMRI). The resulting stability was measured in a kinematics test rig, and compared to the ‘anatomic’ sMCL+POL reconstruction of LaPrade.Abstract
Introduction
Methods
Controversy exists regarding the optimal tibial coronal alignment in total knee arthroplasty. Many believe navigation or robotics are required to set kinematic alignments or to ensure they remain within ‘safe’ limits e.g. maximum 5° varus on the tibia. Given most navigation or robotic systems require the surgeon to identify the ankle malleoli, this study aimed to radiographically analyse standardly used intra-operative landmarks around the ankle, assessing their value in achieving kinematic alignment / setting safety boundaries. Long leg alignment radiographs were analysed independently by two orthopaedic surgeons at two time points, eight weeks apart. Angles were measured between the long axis of the tibia (TB) and: 1. lateral malleolus (TB-LM), 2. lateral border of the talus (TB-LT) and 3. medial aspect of the medial malleolus (TB-MM). Intra- and inter-rater reliabilities were assessed.Abstract
Introduction
Materials and Methods
In recent years, CTA has been an effective training adjunct for orthopaedic procedures. ACLR is a complex procedure with a steep learning curve. To design a multimedia CTA learning tool for ACLR using a modified Delphi methodology.Abstract
Introduction
Aim
Failing total knee replacement management has included isotope bone scan to identify infection or loosening. BASK guidance suggests bone scans have a poor positive predictive value and are not advised. We assessed isotope bone scanning as a negative predictor to exclude loosening or infection in failing total knee replacement. Retrospective review of consecutive bone scans performed to investigate painful total knee replacements for a one-year period (June 2017 to June 2018). 166 bone scans performed. 33 excluded (no notes or scan for other reasons). Demographic information, age of prosthesis, clinic review date, serological markers, results of aspiration and subsequent intraoperative findings also recorded.Abstract
Introduction
Methodology
Prospective single-surgeon case-series evaluating patients undergoing surgery by this technique. 76 cases (mean age of 33.2 years) who had primary ACL reconstruction with BTB or quadriceps tendon with bone block, were divided into 2 matched groups (age, sex and type of graft) of 38 each based on the method of femoral fixation used (interference screw or adjustable cortical suspension). Patients were followed up clinically and using PROMS from NLR with EQ-5D, KOOS, IKDC and Tegner scores. Complications and return to theatre were noted. Paired two-tailed student t-tests and Chi-square tests were employed for statistical analysis. At a mean follow-up of 82 months, peri-operative mean EQ-5D VAS, EQ-5D Index, KOOS, IKDC and Tegner activity scores showed significant improvement (p<0.05), but no significant difference between the two groups (p>0.05). Mean graft length and diameter was 77mm and 9.3 respectively. Mean interval from injury to surgery was 10.5 months. 18(23.7%) patients had associated meniscal tear with 73.3 % undergoing repair. 10 cases (13.2 %) returned to theatre including, MUA for arthrofibrosis (n=2) and intra-substance graft failure (n=2). 3 cases had to be converted to interference screw fixation due to the tightrope cutting through from the femoral bone block as a result of a technical pitfall.Abstract
Methodology
Results
Fracture dislocation of the knee involves disruption of knee ligaments with associated tibial plateau fracture. If these injuries are not evaluated swiftly, can result in a limb-threatening injury. The aim of this study is to look at the clinical outcomes of a single surgeon case series at a major trauma centre. Prospectively collected data was analysed for a 5-year period. Primary outcome measures used were International Knee Documented Committee (IKDC) score and Knee Injury & Osteoarthritis Outcome Score (KOOS). The secondary outcome measures include Tegner activity scale, knee range of movements and complications.Abstract
Background
Methods
COVID-19 reduced availability of cross-sectional imaging, prompting the need to clinically justify pre-operative computed tomography (CT) in tibial plateau fractures (TPF). The study purpose was to establish to what extent does a CT alter the pre-operative plan in TPF compared to radiographs. There is a current paucity of evidence assessing its impact on surgical planning 50 consecutive TPF with preoperative CT were assessed by 4 consultant surgeons. Anonymised radiographs were assessed defining the column classification, planned setup, approach, and fixation technique. At a 1-month interval, randomised matched CT scans were assessed and the same data collected. A tibial plateau disruption score (TPDS) was derived for all 4 quadrants (no injury=0,split=1,split/depression=2 and depression=3). Radiograph and CT TPDS were assessed using an unpaired T-test.Abstract
INTRODUCTION
METHODOLOGY
Spinal local anaesthesia and opioids have long been used as peri-operative analgesia for patients undergoing arthroplasty procedures. However, intrathecal opioids are associated with numerous complications. ERAS® society guidelines for elective knee replacement (2019) strongly discourage the use of spinal opioids. This study aims to report the impact of low-dose spinal and local infiltrative analgesia on patients undergoing elective knee replacement. Retrospective cohort study of patients undergoing knee replacement under the ERAS protocol over 2 years, at a district general hospital under the care of a single surgeon.Abstract
Introduction
Methodology
Knee osteotomy, both high tibial and distal femoral osteotomy, is a well-recognised treatment for young, active patients with unicompartmental knee osteoarthritis. Osteotomy around the knee is usually performed as an inpatient procedure. The aim of this study was to assess the effectiveness and patient satisfaction of our day-case protocol for knee osteotomy. All patients who underwent day-case knee osteotomy at the study unit, over a three-year period, were reviewed to assess the success of ambulatory care for knee osteotomy. Patients were sent questionnaires to assess functional outcome and patient satisfaction with our day-case process.Abstract
Introduction
Methodology
A revision knee replacement (rKR) network model has been introduced in the UK to improve clinical outcomes for patients and reduce healthcare costs. However, the current practice of different types of surgical unit is not well understood. The aim of this study was to answer: “How complex are rKR cases at a Major Revision Centre (MRC)?” Retrospective cohort study at the Nuffield Orthopaedic Centre, Oxford from 2015 - 2018. Case complexity was classified using the Revision Knee Complexity Classification (RKCC). Referral source, technical details of surgery and hospital admission impact were recorded.Abstract
Introduction
Methodology
The Wells score is commonly used to assess the risk of proximal Deep Vein Thrombosis (DVT) following Knee Arthroplasty (KA). The National Institute for Health and Care Excellence (NICE) guidelines recommend an Ultrasound scan in patients with a Wells score of 2 points or more. We wanted to assess how often this protocol resulted in a scan being done and how many were negative. Details of all postoperative Ultrasound scans performed up to 90 days were audited in a high-volume unit between 1st January 2016 and 31st December 2020. This included all Lower Limb Arthroplasty patientsAbstract
Introduction
Methodology
The radiographic or bony landmark techniques are the two most common methods to determine Medial patellofemoral ligament (MPFL) femoral tunnel placement. Their intra/inter-observer reliability is widely debated. The palpation technique relies on identifying the medial epicondyle (ME) and adductor Tubercle (AT). The central longitudinal artery and associated vessels (CLV) are consistently seen in the surgical dissection during MPFL reconstruction. The aim of this study was to investigate the anatomic relationship of CLV to ME-AT and thereby use CLV as an important vascular landmark during MPFL reconstruction. A retrospective review of MRI scans in skeletally mature patients presenting to a tertiary referral knee clinic was undertaken. Group-N consisted of any presentation without patellofemoral instability or malalignment (PFI). Group-P with PFI. MRI's were reviewed and measured by two Consultant Radiologists for the CLV-ME-AT anatomy and relationship. Following exclusions 50 patients were identified in each group. The CLV passed anterior to the AT and ME in all patients. ME morphology did not differ greatly between the groups except in the tubercle height, where there was a statically but not clinically significant difference (larger in the non-PFI group, 2.95mm vs 2.52mm, p=0.002). The CLV to ME Tip distance was consistent between the groups (Group PFI group 3.8mm & ‘normal’ non-PFI Group 3.9mm). The CLV-ME-AT relationship remained consistent despite patients presenting pathology. The CLV consistently courses anterior to ME and AT. The CLV could be used as a vascular landmark assisting femoral tunnel placement during MPFL reconstruction.Abstract
The popularity of all-inside meniscal repair devices has led to a shift away from inside-out meniscus repair without comparative studies to support the change. The aim of this study was to compare the failure rate and time to failure of all-inside and inside-out meniscus repair performed in elite athletes. A retrospective review was performed of all elite athletes who underwent meniscal repair, with a minimum of two-year follow-up between 2013 and 2019. Repairs were classified as all-inside or inside-out according to the repair technique. Failure was defined as undergoing a subsequent surgery to address a persistent meniscal tear.Abstract
Introduction
Methodology
In cementless UKR, primary fixation of the tibial component is achieved by press-fitting a keel (i.e. with interference) into a vertical slot cut into the proximal tibia. This may adversely affect the structural integrity of surrounding bone. Early post-operative peri-prosthetic tibial fractures are 7x more common in very small knees, but the aetiology of these fractures is unknown - such sizes are rarely used in the UK but more common in Asian populations. This study explores the effect of keel-related features in fracture risk of these very small tibias. This Abstract
Introduction
Method
Anxiety and depression are risk factors for poor outcome following knee replacement surgery. The aim of this study was to investigate the prevalence of anxiety and depression before and after primary (pKR) and revision knee replacement (rKR). Retrospective cohort study. 315,720 pKR and 12,727 rKR recruited from the NHS Patient Reported Outcome Measures (PROMs) programme from 2013–2021. Anxiety and depression were defined using: (i) Survey question: “Have you been told by a doctor that you have depression? Yes/No”; (ii) EQ-5D anxiety/depression domain. Rates of EQ-5D anxiety/depression were investigated at baseline and at 6-months following surgery. The prevalence of depression was investigated by patient age and gender.Abstract
Introduction
Methodology