header advert
Results 81 - 100 of 812
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 45 - 45
7 Aug 2023
Bertram W Wylde V Woodward T Gooberman-Hill R Whitehouse M Howells N
Full Access

Abstract

Introduction

Total knee replacement (TKR) aims to reduce pain and functional limitations. Despite a good outcome for many, 15–20% patients report chronic pain three months after TKR.

The STAR Care Pathway is a clinically important and cost effective treatment to improve pain outcomes over 1 year for people with chronic pain at 3 months after total knee replacement surgery. The care pathway is delivered by specially trained Extended Scope Practitioners (ESPs).

There is a gap between research findings and translation into practice. This work shows how the STAR trial findings were implemented into NHS practice at a single centre and the further work required to enable national implementation.

Methodology

Trial findings were presented to NHS managers with a business case for an implementation pilot. Trial documentation was adapted for use in usual care using the COM-B model for behaviour change and evidence-based approaches to increase the return of postal questionnaires. Trial sites were contacted to understand their capacity to implement the intervention locally.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 46 - 46
7 Aug 2023
Rahman A Heath D Mellon S Murray D
Full Access

Abstract

Introduction

In cementless UKR, early post-operative tibial fractures are 7x more common in very small tibias. A smaller keel has been shown to reduce this fracture risk, but its effect on fixation is unassessed. This mechanical study assesses the effect of keel interference and size on sagittal micromotion of the tibial component in physiological loading positions.

Method

A high-resolution Digital Image Correlation setup was developed and validated to an accuracy of 50 micrometres. Variants of tibial components were 3D-printed: standard, no-interference, no-keel, and a new small keel. Components were implanted into bone-analogue foam which was machined to a CT-reconstructed small tibia, using surgical technique. Tibias were loaded to 200N in physiological loading positions: 8mm (step-up) and 15mm (lunge) posterior to midpoint, and micromotion was assessed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 33 - 33
7 Aug 2023
Myatt D Marshall M Franklin M Robb C
Full Access

Abstract

High tibial osteotomy (HTO) is a well-recognised procedure to address medial compartment osteoarthritis (OA). There remains dispute on the impact of pre-operative patient factors on patient related outcome measures (PROMS).

Does BMI and age affect > 2 year and > 5 year oxford knee scores (OKS) and Knee injury and osteoarthritis outcome scores (KOOS).

A retrospective review of a prospectively collected database was performed. Timeframe was 26/6/2014 and 25/8/2022. BMI and age were recorded. OKS and KOOS were collected at > 2 years and > 5 years.

There were 81 procedures included, of these 50 had OKS and KOOS scores at > 2 years and 35 at > 5 years. Median BMI was 28.5kg/m2, range was 18.6–40.8kg/m2. Spearman's rank for >2 year OKS was p(df)=−0.210 p=0.157, > 5 year OKS p(df)=−0.215 p=0.230. For > 2 year and > 5 year KOOS subscales there were no statistically significant associations on Spearman's rank.

For age, median age was 52.5, range 26–71 years old. OKS at >2 year p(df)=0.068 p=0.664, OKS >5 years p(df)=0.065 p= 0.709. For >2 year and > 5 year KOOS subscales there were no statistically significant associations on Spearman's rank.

There were no adverse outcome in patients up-to the age of 71. There were no statistically significant Spearman's rank correlations between PROMS and OKS/KOOS scores. This supports recent KOG consensus statement highlighting physiological age importance vs chronological age. Of note there were more negative associations in the BMI group compared with age.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 36 - 36
7 Aug 2023
Matthews S Acton D Tucker A Graham J
Full Access

Abstract

Introduction

The Syn-VAR RCT is the first of its kind comparing hamstrings autograft v synthetic neoligament for MPFL reconstruction.

Our aim is to evaluate short and long term patient related outcomes measures (PROMs) following synthetic / autologous MPFL reconstruction in a heterogenous cohort of patients with recurrent patellar instability.

Method

20 patients meeting inclusion criteria were recruited and randomised. Standardised surgery was performed by a single surgeon in Altnagelvin Hospital with data collected over 3 years from 2016. Kujala score was the primary outcome measure with data captured preoperatively and 12 weeks/2 years postoperatively. Secondary outcomes included four other validated scores and complications including Norwich Patellar Instability, Lysholm, IKDC and Banff


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 38 - 38
7 Aug 2023
Haque S Downie S Ridley D Dalgleish S Nicol G
Full Access

Abstract

Introduction

There is little published literature to support the claim that a successful total knee replacement (TKR) is predictive of future good outcomes on the contralateral side. The objective was to identify whether outcome from the first of staged TKRs could be used to predict the outcome of the contralateral TKR.

Methodology

This was a retrospective cohort study of 1687 patients over a 25-year period undergoing staged bilateral TKRs in a UK arthroplasty centre. A control group of 1687 patients undergoing unilateral TKR with matched characteristics was identified.

Primary outcomes: satisfaction and Knee Society Score (KSS) at one year.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 74 - 74
7 Aug 2023
Alabdullah M Liu A Xie S
Full Access

Abstract

Rehabilitation exercise is critical for patients’ recovery after knee injury or post-surgery. Unfortunately, adherence to exercise is low due to a lack of positive feedback and poor self-motivation. Therefore, it is crucial to monitor their progress and provide supervision. Inertial measurement unit (IMUs) based sensing technology can provide remote patient monitoring functions. However, most current solutions only measure the range of knee motion in one degree of freedom. The current IMUs estimate the orientation-angle based on the integrated raw data, which might lack accuracy in measuring knee motion. This study aims to develop an IMU-based sensing system using the absolute measured orientation-angle to provide more accurate comprehensive monitoring by measuring the knee rotational angles.

An IMU sensing system monitoring the knee joint angles, flexion/extension (FE), adduction/abduction (AA), and internal/external (IE) was developed. The accuracy and reliability of FE measurements were validated in human participants during squat exercise using measures including root mean square error (RMSE) and correlation coefficient.

The RMSE of the three knee angles (FE, AA, and IE) were 0.82°, 0.26°, and 0.11°, which are acceptable for assessing knee motion. The FE measurement was validated in human participants and showed excellent accuracy (correlation coefficient of 0.99°). Further validation of AA and IE in human participants is underway.

The sensing system showed the capability to estimate three knee rotation angles (FE, AA, and IE). It showed the potential to provide comprehensive continuous monitoring for knee rehabilitation exercises, which can also be used as a clinical assessment tool.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 69 - 69
7 Aug 2023
Kumar A Stevens S Jonas S White S Agarwal S
Full Access

Abstract

Introduction

Isolated patellofemoral joint(PFJ) osteoarthritis affects approximately 10% of patients aged over 40 years and treatment remains controversial. Our aim was to evaluate long term functional and radiological outcomes following PFJ arthorplasty with the Femoro Patella Vialli (FPV) prosthesis as this evidence is lacking in literature.

Methodology

A retrospective review of prospectively collected PROMS in patients undergoing Patellofemoral arthroplasty. Single centre trial. Between 2004 and 2008, 101 FPV patellofemoral arthroplasties were performed in 80 patients with isolated patellofemoral joint osteoarthritis. Data was collected as a part of routine follow-up for up to 6 years and additional long term data was collected at 16 years.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 6 - 6
7 Aug 2023
Hampton M Balachandar V Charalambous C Sutton P
Full Access

Abstract

Introduction

Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA) and this has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA.

Methodology

A UK based, three round, online modified Delphi Expert Consensus Study was completed focussing on cementation technique in TKA. Experts were identified as having a minimum of 5 years Consultant experience in the NHS and fulfilling any one of the following three criteria:

· A ‘high volume’ knee arthroplasty practice (>150 TKA per annum) as identified from the National joint registry (NJR).

· A senior author of at least 5 peer reviewed articles related to TKA in the previous 5 years

· A named trainer for a post CCT fellowship in TKA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 4 - 4
7 Aug 2023
Khaleeq T Saeed AZ Ahmed U Ajula R Boutefnouchet T D'Alessandro P Malik S
Full Access

Abstract

Customised individually made implants(CIM) total knee arthroplasty(TKA) are custom-made to better fit patients native anatomy and aim to improve outcomes which can be variable with conventional off-the-shelf(OTS).

A systematic review and meta-analysis was conducted searching the MEDLINE and Embase databases. Studies reporting on patient reported outcome measures, clinical or radiological outcomes were included.

23 studies satisfied the search criteria (case-control studies14, case series8, cross-sectional studies1). There were 2,856(CIM) and 1,877(OTS) implants. The overall revision-rate was higher in CIM 5.9%vs3.7%OTS [OR 1.46(95% CI 0.82–2.62)]. MUA was higher in the CIM group 2.2%vs.1.1%OTS [OR 2.95(95% CI 0.95–9.13)] and overall complications rate was also higher in the CIM group 5% vs. 4.5%OTS [OR 1.45(95% CI 0.53–3.96)]. LOS was significantly shorter in the CIM group 2.9 days vs. 3.5 days [MD −0.51(95% CI −0.82–0.20)]. Pooled analysis for KSS showed no difference between CIM and OTS groups(Knee=90.5 vs. 90.6 [MD-0.27,(95% CI −4.27–3.73)] and Function=86.1 vs. 90.6[MD 1.51 (95% CI −3.69–6.70)] component of the scores. There was no significant difference in post-operative ROM between CIM and OTS groups 117.3° vs. 115.0° [MD 0.02,(95% CI −1.70–1.74)].

CIM TKAs has theoretical benefits over OTS TKAs however in this review they were associated with higher complication, MUA and revision rates with no difference in outcome scores and no improvement in target alignment. The findings of this review does not support the use of CIM over OTS prosthesis in total knee arthroplasty.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 2 - 2
7 Aug 2023
Warder H Hall-Thompson B Sanders T Wright N Alford S Johnson D
Full Access

Abstract

The Montgomery ruling advocates patients be informed of ‘material risks’ of a procedure. With no guidelines for patients wishing to return to high activity levels after knee arthroplasty, we explore patient and surgeon perceptions in climbers.

Ethical approval was granted by the University of Central Lancashire. Anonymous questionnaires were sent via email and social media to consultant knee arthroplasty surgeons and to climbers/mountaineers across the UK. Consultants were asked about advice given for patients who participate in climbing. Climbers were asked about their experiences of knee arthroplasty and return to activity.

Of 33 knee arthroplasty surgeons, 11(33%) were firmly against any return to climbing, 10(30%) counselled against it, and 12(36%) were open to return to previous activity. Of 11(33%) surgeons who do not gather information about levels of climbing, 8 would not provide specific advice regarding risks of returning to sport. Of 28 climbers, only 5(18%) were informed to cease completely, with 11(39%) cautioned against and 12(43%) permitted to return. There was no correlation between the advice received and climbing ability post-operatively, (kappa=0.143,p=0.058), with a substantial agreement between ability 1-year post-operatively and currently, (kappa=0.689,p<0.001).

There is a discrepancy between the advice given and received by climbers/mountaineers prior to knee arthroplasty, with ability post-operatively having no relationship to advice given. Climbing is possible at high level with no reported complications following knee arthroplasty. The 1-year time point is predictive of longer-term outcome. This information should help surgeons better inform their patients preoperatively.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 31 - 31
7 Aug 2023
Myatt D Marshall M Ankers T Robb C
Full Access

Abstract

Unicompartment knee replacement (UKR) has been an effective treatment of isolated medial compartment osteoarthritis (OA). There has been several studies which suggest that patellofemoral (PFJ) wear may not be a relative contraindication for UKR with no statistical difference in failure rates. There is currently conflicting evidence on the role of BMI.

We will review if BMI and PFJ wear impacts on the post operative functional scores following UKR.

A retrospective review of a prospectively collected database was performed. Data was collected between 26/6/2014 and 25/8/2022. 159 UKR procedures were identified. BMI and PFJ cartilage wear were collected. Oxford knee scores (OKS) were collected at > 2 years. PFJ wear was split into International Cartilage Research Society (ICRS) grades I&II and III&IV.

159 UKR procedures were identified, of these 115 had 2 year follow up. There were 77 who had OKS recorded at 2 years. For PFJ wear there was no statistical difference in the median OKS at 2 years 45 vs 43.5 (p=0.408). Assessing the BMI the median was 29kg/m2, range 20–43kg/m2. Spearman's rank was performed to assess the correlation between BMI and >2 year OKS, this demonstrated a moderately negative correlation p(df)=−0.339 (CI 95% −0.538, −0.104) p=0.004.

There is no statistically significant difference in >2 year OKS following UKR regardless of PFJ wear. There is a moderately negative correlation between BMI and >2 year OKS which was significant p=0.004. Therefore BMI is a more important consideration when counselling patients for UKR.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 34 - 34
7 Aug 2023
Afzal I Radha S Mitchell P
Full Access

Abstract

Multidisciplinary team (MDT) meetings in orthopaedic surgery are evolving. The goals include patient optimisation, surgical planning and discharge arrangements, individually on a patient specific basis. In line with British Association Surgery of the Knee and GIRFT guidelines, we report our regional experience on the implementation and evolution of our regional Revision Knee Arthroplasty MDT.

We undertook a retrospective review of the process, cases discussed and quality assurance conducted in the weekly MDT.

Since implementation of the MDT meeting in January 2019, 550 patients with painful joint replacements have been discussed. In May 2021, we formalised our ‘terms of reference’ and ‘standard operating procedures’ which are adhered to by the consultants operating within the network, all of whom attend the meeting. A proforma has been developed and is completed for all cases capturing all pertinent information. All cases are graded according to R1, R2, or R3 complexity scale. Since its inception, the MDT has looked at all post-operative imaging, we now describe a new classification system for grading the appearances. Confirmation of the pre-operative plan and actual surgical intervention is reviewed and audited. In addition, confirmation of indication of revision at the time of operation is reviewed and validated for accuracy with benefits to the unit, individual surgeon and the NJR.

In conclusion, the implementation of the revision MDT facilitating pre-operative revision arthroplasty discussion and post-operative quality assurance processes enable surgeons to educate, reflect on their practice and ensure that the highest standards of care are being provided.


Abstract

Introduction

Revision total knee arthroplasty (RTKA) is a complex procedure with higher rates of re-revision, complications and mortality compared to primary TKA. We report the effects of the establishment of a Revision Arthroplasty Network (The East Midlands Specialist Orthopaedic Network; EMSON).

Methodology

The Revision Arthroplasty Network was established in January 2015 and covered the Nottinghamshire and Lincolnshire areas of England. This comprises a collaborative weekly multidisciplinary meeting where upcoming RTKA procedures are discussed, and a plan agreed.

Using the Hospital Episode Statistics database, RTKA procedures carried out between 2011 and 2018 from the five EMSON hospitals were compared to all other hospitals in England. Age, sex, and Hospital Frailty Risk scores were used as covariates.

The primary outcome was re-revision surgery within 1 year of the index revision. Secondary outcomes were re-revision surgery within two years, any complication within one and two years and median length of stay.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 56 - 56
7 Aug 2023
Nicholls K Wilcocks K Shean K Anderson J Matthews A Vachtsevanos L
Full Access

Abstract

Introduction

Compared to the standard Tomofix plate, the anatomical Tomofix medial high tibial (MHT) plate has been shown to improve anatomical fit and post correction tibial contour, following high tibial osteotomy (HTO). Clinical data on surgical complications, osteotomy union rates and survivorship with the anatomical Tomofix MHT plate however remain limited. This study reports mid-term results of HTO surgery, using the anatomical Tomofix MHT plate.

Methods

All patients undergoing HTO surgery using the anatomical Tomofix MHT plate between 2017 and 2022 were included in the study. Data on complications, osteotomy union rates and survivorship were collected prospectively and retrospectively analysed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 63 - 63
7 Aug 2023
Kumar D Agarwal A Kushwaha N
Full Access

Abstract

Purpose

Since arthroscopic reconstruction of the anterior cruciate ligament (ACL) started, the use of peroneus longus grafts for primary ACL reconstruction (ACLR) was never thought of as there is very scant literature on it. So, our study aims to compare the functional outcome and complications in patients with ACL injury managed by ACLR with peroneus longus tendon (PLT) and hamstring tendons (HT) respectively.

Materials and Methods

Patients with 16–50 years of either gender presenting with symptomatic ACL deficiency were admitted for arthroscopic single bundle ACLR and allocated into two groups (PLT and HT) operated and observed. Functional scores (IKDC and Lysholm score), clinical knee evaluation, donor site morbidity (AOFAS score) and thigh circumference were recorded preoperatively and at six months, one year post-operatively. The same post-op rehabilitation protocol was followed in both groups.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 77 - 77
7 Aug 2023
Borque K Han S Gold J Sij E Laughlin M Amis A Williams A Noble P Lowe W
Full Access

Abstract

Introduction

Historic MCL reconstruction techniques focused on the superficial MCL to restore valgus stability while overlooking tibial external rotation and the deep MCL. This study assessed the ability of a contemporary medial collateral ligament (MCL) reconstruction and a deep MCL (dMCL) reconstruction to restore rotational and valgus knee stability.

Methods

Six pairs fresh-frozen cadaveric knee specimens with intact soft tissue were tested in four states: 1) intact 2) after sMCL and dMCL sectioning, 3) contemporary MCL reconstruction (LaPrade et al), and 4) dMCL reconstruction. In each state, four loading conditions were applied at varying flexion angles: 8Nm valgus torque, 5Nm tibial external rotation torque, 90N anterior drawer, and combined 90N anterior drawer plus 5Nm tibial external rotation torque.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 81 - 81
7 Aug 2023
Bliddal H Beier J Hartkopp A Conaghan P Henriksen M
Full Access

Abstract

Introduction

The effectiveness of single intra-articular injections of polyacrylamide hydrogel (iPAAG) and hyaluronic acid (HA) was compared in subgroups of participants from an RCT based on baseline age, BMI or Kellgren-Lawrence (KL) grade.

Methodology

239 participants were randomised to 6 mL iPAAG (Arthrosamid; n=119) or 6 mL HA (Synvisc-One; n=120). Participants continued analgesics (except 48 hours prior to visits) and non-pharmacological therapy. Topical therapies and intra-articular corticosteroids were not allowed. Pre-specified subgroup analyses (age: <70 years, ≥70 years; BMI: normal, overweight, obese; KL grade: 2, 3, 4, 2–3) of change from baseline in WOMAC pain subscale at 52 weeks were based on the least squares means for the treatment-by-week interaction effect using a mixed model for repeated measurement with a restricted maximum likelihood-based approach.


Abstract

Introduction

Transforming outpatient services is a key commitment set out in the NHS Long Term Plan, with particular emphasis on digital solutions to reduce outpatient follow-up (FU) by 25%. This study looks at the potential for removing knee arthroscopy FU by providing a bespoke multimedia report for each individual patient, generated using the Synergy™ Surgeon App (Arthrex)

Methodology

Single District Hospital using a 3 Phase study

Phase 1 – Assessment of cost and environmental impact of outpatient follow up appointments

Phase 2 – Bench marking of existing pathways and patient experience.

Phase 3 – Qualitative assessment of multimedia report feedback of 30 patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 89 - 89
7 Aug 2023
Ahmed I Dhaif F Bowes M Parsons N Hutchinson C Staniszewska S Price A Metcalfe A
Full Access

Abstract

Introduction

Previous research has demonstrated no clinically significant benefit of arthroscopic meniscectomy in patients with a meniscal tear, however, patients included in these studies would not meet current treatment recommendations. Prior to further randomised controlled trials (RCTs) research is needed to understand a younger population in more detail.

Aim

To describe the baseline characteristics of patients with a meniscal tear and explore any association between baseline characteristics and outcome.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 15 - 15
7 Aug 2023
Deo S Jonas S Jhaj J
Full Access

Abstract

INTRODUCTION

The most frequent mode of aseptic failure of primary total knee replacements is tibial baseplate loosening. This is influenced by stresses across the implant-bone interface which can be increased in obese patients leading to potentially higher rates of early failure. The evidence is mixed as to the true effect of elevated BMI (body mass index) on revision rates. We present the experience of early tibial failures in our department and how our implant choices have evolved.

METHODOLOGY

We retrospectively reviewed our unit's arthroplasty database and identified all patients who had sustained mechanical tibial failure. Data were collected on patient demographics, operative details of primary and revision operations, components used, alignment pre and post operatively and indication. Complications and further surgery performed were recorded.