Cite this article:
The aim of this study was to surveil whether the standard operating procedure created for the NHS Golden Jubilee sufficiently managed COVID-19 risk to allow safe resumption of elective orthopaedic surgery. This was a prospective study of all elective orthopaedic patients within an elective unit running a green pathway at a COVID-19 light site. Rates of preoperative and 30-day postoperative COVID-19 symptoms or infection were examined for a period of 40 weeks. The unit resumed elective orthopaedic services on 29 June 2020 at a reduced capacity for a limited number of day-case procedures with strict patient selection criteria, increasing to full service on 29 August 2020 with no patient selection criteria.Aims
Methods
The COVID-19 pandemic led to a national suspension of “non-urgent” elective hip and knee arthroplasty. The study aims to measure the effect of the COVID-19 pandemic on total hip arthroplasty (THA) and total knee arthroplasty (TKA) volume in Scotland. Secondary objectives are to measure the success of restarting elective services and model the time required to bridge the gap left by the first period of suspension. A retrospective observational study using the Scottish Arthroplasty Project dataset. All patients undergoing elective THAs and TKAs during the period 1 January 2008 to 31 December 2020 were included. A negative binomial regression model using historical case-volume and mid-year population estimates was built to project the future case-volume of THA and TKA in Scotland. The median monthly case volume was calculated for the period 2008 to 2019 (baseline) and compared to the actual monthly case volume for 2020. The time taken to eliminate the deficit was calculated based upon the projected monthly workload and with a potential workload between 100% to 120% of baseline.Aims
Methods
Virtual fracture clinics (VFCs) are being increasingly used to offer safe and efficient orthopaedic review without the requirement for face-to-face contact. With the onset of the COVID-19 pandemic, we sought to develop an online referral pathway that would allow us to provide definitive orthopaedic management plans and reduce face-to-face contact at the fracture clinics. All patients presenting to the emergency department from 21March 2020 with a musculoskeletal injury or potential musculoskeletal infection deemed to require orthopaedic input were discussed using a secure messaging app. A definitive management plan was communicated by an on-call senior orthopaedic decision-maker. We analyzed the time to decision, if further information was needed, and the referral outcome. An analysis of the orthopaedic referrals for the same period in 2019 was also performed as a comparison.Introduction
Methods
Bioresorbable orthopaedic devices with calcium phosphate (CaP) fillers are commercially available on the assumption that increased calcium (Ca) locally drives new bone formation, but the clinical benefits are unknown. Electron beam (EB) irradiation of polymer devices has been shown to enhance the release of Ca. The aims of this study were to: 1) establish the biological safety of EB surface-modified bioresorbable devices; 2) test the release kinetics of CaP from a polymer device; and 3) establish any subsequent beneficial effects on bone repair ActivaScrew Interference (Bioretec Ltd, Tampere, Finland) and poly(L-lactide-co-glycolide) (PLGA) orthopaedic screws containing 10 wt% β-tricalcium phosphate (β-TCP) underwent EB treatment. Objectives
Methods
Third-body wear is believed to be one trigger for adverse results
with metal-on-metal (MOM) bearings. Impingement and subluxation
may release metal particles from MOM replacements. We therefore
challenged MOM bearings with relevant debris types of cobalt–chrome
alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate
bone cement (PMMA). Cement flakes (PMMA), CoCr and Ti6Al4V particles (size range
5 µm to 400 µm) were run in a MOM wear simulation. Debris allotments
(5 mg) were inserted at ten intervals during the five million cycle
(5 Mc) test. Objectives
Methods