There is a large amount of evidence available
about the relative merits of unicompartmental and total knee arthroplasty
(UKA and TKA). Based on the same evidence, different people draw
different conclusions and as a result, there is great variability
in the usage of UKA. The revision rate of UKA is much higher than TKA and so some
surgeons conclude that UKA should not be performed. Other surgeons
believe that the main reason for the high revision rate is that
UKA is easy to revise and, therefore, the threshold for revision
is low. They also believe that UKA has many advantages over TKA
such as a faster recovery, lower morbidity and mortality and better
function. They therefore conclude that UKA should be undertaken
whenever appropriate. The solution to this argument is to minimise the revision rate
of UKA, thereby addressing the main disadvantage of UKA. The evidence
suggests that this will be achieved if surgeons use UKA for at least
20% of their knee arthroplasties and use implants that are appropriate
for these broad indications. Cite this article:
The patient with a painful arthritic knee awaiting
total knee arthroplasty (TKA) requires a multidisciplinary approach.
Optimal control of acute post-operative pain and the prevention
of chronic persistent pain remains a challenge. The aim of this
paper is to evaluate whether stratification of patients can help
identify those who are at particular risk for severe acute or chronic
pain. Intense acute post-operative pain, which is itself a risk factor
for chronic pain, is more common in younger, obese female patients
and those suffering from central pain sensitisation. Pre-operative
pain, in the knee or elsewhere in the body, predisposes to central
sensitisation. Pain due to osteoarthritis of the knee may also trigger
neuropathic pain and may be associated with chronic medication like
opioids, leading to a state of nociceptive sensitisation called
‘opioid-induced hyperalgesia’. Finally, genetic and personality
related risk factors may also put patients at a higher risk for
the development of chronic pain. Those identified as at risk for chronic pain would benefit from
specific peri-operative management including reduction in opioid
intake pre-operatively, the peri-operative use of antihyperalgesic
drugs such as ketamine and gabapentinoids, and a close post-operative
follow-up in a dedicated chronic pain clinic. Cite this article:
Periprosthetic joint infection (PJI) is one of
the most feared and challenging complications following total knee arthroplasty.
We provide a detailed description of our current understanding regarding
the management of PJI of the knee, including diagnostic aids,
pre-operative planning, surgical treatment, and outcome. Cite this article:
Partial knee arthroplasty (PKA), either medial
or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty
(PFA) are a good option in suitable patients and have the advantages
of reduced operative trauma, preservation of both cruciate ligaments
and bone stock, and restoration of normal kinematics within the
knee joint. However, questions remain concerning long-term survival.
The goal of this review article was to present the long-term results
of medial and lateral UKA, PFA and combined compartmental arthroplasty
for multicompartmental disease. Medium- and long-term studies suggest
reasonable outcomes at ten years with survival greater than 95% in
UKA performed for medial osteoarthritis or osteonecrosis, and similarly
for lateral Cite this article:
This pilot study reports the clinical outcomes
of a combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty in patients with rotatator cuff arthropathy. A
total of 30 patients (30 shoulders; eight men and 22 women) with
a mean age of 74 years (55 to 84) were assessed at a mean follow-up
of 31 months (24 to 60). The inclusion criteria were painful cuff
tear arthropathy with normal deltoid function and a non-degenerative subscapularis
muscle and tendon and a preserved teres minor. Outcome was assessed using the University of California Los Angeles
score, the Japanese Orthopaedic Association score, and the Oxford
Shoulder Score. Radiographic measurements included the centre of
rotation distance and the length of the deltoid. All clinical scores were significantly improved post-operatively.
The active flexion and external rotation improved significantly
at the most recent follow-up (p <
0.035). Although the mean centre
of rotation distance changed significantly (p <
0.001), the mean
length of the deltoid did not change significantly from the pre-operative
value (p = 0.29). The change in the length of the deltoid with <
100° flexion was significantly less than that with >
100° (p <
0.001). Progressive erosion of the glenoid was seen in four patients.
No patient required revision or further surgery. A combination of partial subscapularis tendon transfer and small-head
hemiarthroplasty effectively restored function and relieved pain
in patients with rotator cuff arthropathy. Cite this article: 2015;97-B:1090–5.
In this Cite this article:
Total knee arthroplasty (TKA) is an established
and successful procedure. However, the design of prostheses continues
to be modified in an attempt to optimise the functional outcome
of the patient. The aim of this study was to determine if patient outcome after
TKA was influenced by the design of the prosthesis used. A total of 212 patients (mean age 69; 43 to 92; 131 female (62%),
81 male (32%)) were enrolled in a single centre double-blind trial
and randomised to receive either a Kinemax (group 1) or a Triathlon
(group 2) TKA. Patients were assessed pre-operatively, at six weeks, six months,
one year and three years after surgery. The outcome assessments
used were the Oxford Knee Score; range of movement; pain numerical
rating scales; lower limb power output; timed functional assessment
battery and a satisfaction survey. Data were assessed incorporating
change over all assessment time points, using repeated measures
analysis of variance longitudinal mixed models. Implant group 2
showed a significantly greater range of movement (p = 0.009), greater
lower limb power output (p = 0.026) and reduced report of ‘worst
daily pain’ (p = 0.003) over the three years of follow-up. Differences
in Oxford Knee Score (p = 0.09), report of ‘average daily pain’
(p = 0.57) and timed functional performance tasks (p = 0.23) did
not reach statistical significance. Satisfaction with outcome was
significantly better in group 2 (p = 0.001). These results suggest that patient outcome after TKA can be influenced
by the prosthesis used. Cite this article:
Arthroplasty registries are important for the
surveillance of joint replacements and the evaluation of outcome. Independent
validation of registry data ensures high quality. The ability for
orthopaedic implant retrieval centres to validate registry data
is not known. We analysed data from the National Joint Registry
for England, Wales and Northern Ireland (NJR) for primary metal-on-metal
hip arthroplasties performed between 2003 and 2013. Records were
linked to the London Implant Retrieval Centre (RC) for validation.
A total of 67 045 procedures on the NJR and 782 revised pairs of
components from the RC were included. We were able to link 476 procedures
(60.9%) recorded with the RC to the NJR successfully. However, 306
procedures (39.1%) could not be linked. The outcome recorded by the
NJR (as either revised, unrevised or death) for a primary procedure
was incorrect in 79 linked cases (16.6%). The rate of registry-retrieval
linkage and correct assignment of outcome code improved over time.
The rates of error for component reference numbers on the NJR were
as follows: femoral head category number 14/229 (5.0%); femoral head
batch number 13/232 (5.3%); acetabular component category number
2/293 (0.7%) and acetabular component batch number 24/347 (6.5%). Registry-retrieval linkage provided a novel means for the validation
of data, particularly for component fields. This study suggests
that NJR reports may underestimate rates of revision for many types
of metal-on-metal hip replacement. This is topical given the increasing
scope for NJR data. We recommend a system for continuous independent
evaluation of the quality and validity of NJR data. Cite this article:
Instability is the reason for revision of a primary
total knee replacement (TKR) in 20% of patients. To date, the diagnosis
of instability has been based on the patient’s symptoms and a subjective
clinical assessment. We assessed whether a measured standardised
forced leg extension could be used to quantify instability. A total of 25 patients (11 male/14 female, mean age 70 years;
49 to 85) who were to undergo a revision TKR for instability of
a primary implant were assessed with a Nottingham rig pre-operatively
and then at six and 26 weeks post-operatively. Output was quantified
(in revolutions per minute (rpm)) by accelerating a stationary flywheel.
A control group of 183 patients (71 male/112 female, mean age 69
years) who had undergone primary TKR were evaluated for comparison. Pre-operatively, all 25 patients with instability exhibited a
distinctive pattern of reduction in ‘mid-push’ speed. The mean reduction
was 55 rpm ( Cite this article:
There is a high rate of mortality in elderly
patients who sustain a fracture of the hip. We aimed to determine
the rate of preventable mortality and errors during the management
of these patients. A 12 month prospective study was performed on
patients aged >
65 years who had sustained a fracture of the hip.
This was conducted at a Level 1 Trauma Centre with no orthogeriatric
service. A multidisciplinary review of the medical records by four
specialists was performed to analyse errors of management and elements
of preventable mortality. During 2011, there were 437 patients aged
>
65 years admitted with a fracture of the hip (85 years (66 to
99)) and 20 died while in hospital (86.3 years (67 to 96)). A total
of 152 errors were identified in the 80 individual reviews of the
20 deaths. A total of 99 errors (65%) were thought to have at least
a moderate effect on death; 45 reviews considering death (57%) were thought
to have potentially been preventable. Agreement between the panel
of reviewers on the preventability of death was fair. A larger-scale
assessment of preventable mortality in elderly patients who sustain
a fracture of the hip is required. Multidisciplinary review panels
could be considered as part of the quality assurance process in
the management of these patients. Cite this article
Satisfaction with care is important to both patients
and to those who pay for it. The Net Promoter Score (NPS), widely
used in the service industries, has been introduced into the NHS
as the ‘friends and family test’; an overarching measure of patient
satisfaction. It assesses the likelihood of the patient recommending
the healthcare received to another, and is seen as a discriminator
of healthcare performance. We prospectively assessed 6186 individuals
undergoing primary lower limb joint replacement at a single university
hospital to determine the Net Promoter Score for joint replacements
and to evaluate which factors contributed to the response. Achieving pain relief (odds ratio (OR) 2.13, confidence interval
(CI) 1.83 to 2.49), the meeting of pre-operative expectation (OR
2.57, CI 2.24 to 2.97), and the hospital experience (OR 2.33, CI
2.03 to 2.68) are the domains that explain whether a patient would
recommend joint replacement services. These three factors, combined
with the type of surgery undertaken (OR 2.31, CI 1.68 to 3.17),
drove a predictive model that was able to explain 95% of the variation
in the patient’s recommendation response. Though intuitively similar,
this ‘recommendation’ metric was found to be materially different
to satisfaction responses. The difference between THR (NPS 71) and
TKR (NPS 49) suggests that no overarching score for a department
should be used without an adjustment for case mix. However, the
Net Promoter Score does measure a further important dimension to
our existing metrics: the patient experience of healthcare delivery. Cite this article:
The cementless Oxford unicompartmental knee replacement
has been demonstrated to have superior fixation on radiographs and
a similar early complication rate compared with the cemented version.
However, a small number of cases have come to our attention where,
after an apparently successful procedure, the tibial component subsides into
a valgus position with an increased posterior slope, before becoming
well-fixed. We present the clinical and radiological findings of
these six patients and describe their natural history and the likely
causes. Two underwent revision in the early post-operative period,
and in four the implant stabilised and became well-fixed radiologically with
a good functional outcome. This situation appears to be avoidable by minor modifications
to the operative technique, and it appears that it can be treated
conservatively in most patients. Cite this article: