Advertisement for orthosearch.org.uk
Bone & Joint Open Logo

Receive monthly Table of Contents alerts from Bone & Joint Open

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Bone & Joint Open at:

Loading...

Loading...

Open Access

Knee

Dorsal cortex line is more reliable than transepicondylar axis for rotation in revision total knee arthroplasty with severe bone loss



Download PDF

Abstract

Aims

The transepicondylar axis is a well-established reference for the determination of femoral component rotation in total knee arthroplasty (TKA). However, when severe bone loss is present in the femoral condyles, rotational alignment can be more complicated. There is a lack of validated landmarks in the supracondylar region of the distal femur. Therefore, the aim of this study was to analyze the correlation between the surgical transepicondylar axis (sTEA) and the suggested dorsal cortex line (DCL) in the coronal plane and the inter- and intraobserver reliability of its CT scan measurement.

Methods

A total of 75 randomly selected CT scans were measured by three experienced surgeons independently. The DCL was defined in the coronal plane as a tangent to the dorsal femoral cortex located 75 mm above the joint line in the frontal plane. The difference between sTEA and DCL was calculated. Descriptive statistics and angulation correlations were generated for the sTEA and DCL, as well as for the distribution of measurement error for intra- and inter-rater reliability.

Results

The external rotation of the DCL to the sTEA was a mean of 9.47° (SD 3.06°), and a median of 9.2° (IQR 7.45° to 11.60°), with a minimum value of 1.7° and maximum of 16.3°. The measurements of the DCL demonstrated very good to excellent test-retest and inter-rater reliability coefficients (intraclass correlation coefficient 0.80 to 0.99).

Conclusion

This study reveals a correlation between the sTEA and the DCL. Overall, 10° of external rotation of the dorsal femoral cortical bone to the sTEA may serve as a reliable landmark for initial position of the femoral component. Surgeons should be aware that there are outliers in this study in up to 17% of the measurements, which potentially could result in deviations of femoral component rotation.

Cite this article: Bone Jt Open 2024;5(12):1067–1071.

Take home message

This study introduces a novel landmark for femoral component rotation in revision total knee arthroplasty with severe bone loss.

The validity and reliability are shown in comparison to the transepicondylar axis.

This landmark can be helpful, when the condyles are destroyed or total femur replacement is planned.

Introduction

The rotational alignment of the femoral component in total knee arthroplasty (TKA) is essential for correct patellar tracking. Malpositioning may cause pain, impaired range of motion (ROM), and subluxation or dislocation of the patella.1-3 The surgical transepicondylar axis (sTEA) has been proposed as a reliable landmark to determine femoral component rotation, facilitating the appropriate balancing of both the extension and flexion gap.4-6 However, when using the sTEA, both the medial and lateral epicondyle need to be well preserved.

In revision TKA, severe bone loss of the distal femur may lack proper orientation for placing the femoral revision component or even complete distal femur components correctly. Such severe bone loss may occur in periprosthetic fracture, as well as in septic and aseptic periprosthetic loosening. The number of these cases is increasing and poses a challenge in achieving accurate alignment of the femoral component.7-10 The anterior femoral cortex has been shown to be 13.4° (SD 3.4°) externally rotated to the TEA; however, considerable variance (3.2° to 23.3°) exists, and this aspect of the femur may be compromised in revision knee arthroplasty.11 Consequently, the existence of a reliable landmark in the supracondylar region and its correlation with the surgical transepicondylar axis are the subjects of investigation in this study.

The primary aim was to study the accuracy in measuring the dorsal cortex line (DCL) and to analyze the correlation between DCL and sTEA (Figure 1). We hypothesized that the DCL could be measured reproducibly on CT scans and that there is a correlation between DCL and sTEA.

Fig. 1 
          a) Surgical transepicondylar axis in a coronal CT plane; b) dorsal cortex line measured 75 mm above the joint line in coronal plane; and c) an example of overlap between surgical transepicondylar axis and dorsal cortex line.

Fig. 1

a) Surgical transepicondylar axis in a coronal CT plane; b) dorsal cortex line measured 75 mm above the joint line in coronal plane; and c) an example of overlap between surgical transepicondylar axis and dorsal cortex line.

Methods

A total of 75 CT scans of the knee were randomly selected from patients who underwent patient-specific TKA in the database of our university hospital. These CT scans were conducted using a ten-slice CT scanner (Philips Brilliance, MRC 600 8.0 MHU, Netherlands).

This study was carried out in accordance with the World Medical Association Declaration of Helsinki.12 Separate ethical approval was not necessary as all data were handled anonymously within the whole data collection process.

Three experienced orthopaedic surgeons (MS, EK, MA) were assigned to measure a group of 25 CT scans twice, with a two-week interval between the measurements. In addition, each surgeon was asked to measure 25 scans from a different group once. There was no interaction between the surgeons. Consequently, each scan was measured twice by one rater and once by another rater, ensuring that no interaction effects were present.

First, the angles of the posterior condylar line (PCL) and the sTEA were measured in relation to the coronal plane. The DCL was defined in the coronal plane as a tangent to the dorsal femoral cortex located 75 mm above the joint line in the frontal plane. Subsequently, the angles between sTEA and PCL and the angles between sTEA and DCL were measured by subtracting the respective measured angles.

Statistical analysis

A researcher (RP) who was not involved in the measurement process received the collected data and performed the analysis in a blinded fashion (RP), unaware of the purpose of the study and the raters who provided the datasets. Descriptive statistics and angulation correlations were generated for the sTEA and DCL, as well as for the distribution of measurement error for intra- and inter-rater reliability. Pearson correlation coefficient was calculated to assess the interchangeability of the sTEA and DCL, while the intraclass correlation coefficient (ICC) two-way random single measure was calculated to evaluate intra- and inter-rater reliability, respectively. SPSS Statistics v. 28.0 (IBM, USA) was used for these calculations.

Results

All 75 randomly selected CT scans were successfully measured without any drop-outs. In the coronal plane, the PCL was 2.51° (SD 9.00°) referenced to the horizontal line, while the mean external rotation angles were 0.85° (SD 8.57°) for the sTEA and 8.26° (SD 8.28°) for the DCL. On average, an additional external rotation of 2.09° (1.47°) was observed between the sTEA and PCL. The mean external rotation of the DCL to the sTEA was a mean 9.47° (SD 3.06°), a median of 9.2° (IQR 7.45° to 11.60°), with a minimum value of 1.7° and maximum of 16.3°.

The measurements of the DCL demonstrated very good to excellent test-retest and inter-rater reliability coefficients, with correlation values ranging from r = 0.81 to r = 0.98, and ICC ranging from 0.80 to 0.99. The mean intra-rater measurement error for DCL was 0.59° (SD 1.22°), and between raters it was 0.58° (SD 1.30°). The IQR for the DCL measurements was between -0.10° and 1.20° of external rotation (Figure 2). Outliers were identified, with a minimum value of -2.30° (considered as an outlier, falling below 1.5-times the IQR below the first quartile) and a maximum value of 4.80°. Overall, a very good to excellent correlation between the sTEA and DCL was observed, ranging from 0.89 to 0.94. The results are summarized in Table I.

Fig. 2 
          Intra- and inter-rater measurement differences for the measured angles between dorsal cortex line (DCL) and surgical transepicondylar axis (sTEA).

Fig. 2

Intra- and inter-rater measurement differences for the measured angles between dorsal cortex line (DCL) and surgical transepicondylar axis (sTEA).

Table I.

Main results.

Variable PCL sTEA DCL
Mean α angle (SD)* 2.51 (9.00) 0.85 (8.57) 8.26 (8.28)
Mean ER to PCL (SD) 2.09 (1.47)
Mean ER sTEA (SD) 9.47 (3.06)
Mean ICC, range 0.89 to 0.94
Mean ITE (SD) 1.09° (1.15°)
  1. *

    α angle measured to horizontal line in coronal plane.

  1. DCL, dorsal cortex line; ER, external rotation; ICC, interclass correlation; ITE, average test-retest error; PCL, posterior condylar line; sTEA, surgical transepicondylar axis.

Discussion

The main finding of this study demonstrates good to excellent inter- and intra-rater reliability for identifying the DCL of the distal femur. This finding suggests that the DCL can serve as a reliable landmark in revision TKA when both femoral condyles are absent. The DCL was found to be approximately 10° externally rotated relative to the sTEA, with very good to excellent test-retest and inter-rater reliability coefficients observed in CT scans.

The axial alignment of TKA is not well understood,13,14 but the sTEA is recognized as a reliable parameter for determining femoral component rotation in both in situ and CT scan assessments.15,16 However, identifying the transepicondylar axis underlies a certain intra- and inter-rater variation. In a study involving six cadaver specimens, Stoeckl et al17 reported that, even under ideal conditions, the identification of the TEA can vary by up to 5 mm, with the identification points distributed over an area of up to 298 mm2. This variation could lead to potential external or internal rotation of the femoral component by up to 8° in the worst-case scenario. In the present study, the angle between the PCL and sTEA was used as a reference parameter, and the reported angles were consistent with those found in the literature.18 It is important to note that the current study used the sTEA, which differs from the anatomical transepicondylar axis,which is more externally rotated relative to the sTEA.19,20

Reliable landmarks in the supracondylar region are scarce. The distal anterior femoral cortical axis (DAFCA), as described by Sathappan et al,11 is one of the few bony landmarks above the epicondyles suggested for femoral component rotation in revision TKA cases involving distal femur deterioration. The DAFCA was measured approximately 60 mm from the joint line, with the limitation of being unclear when significant notching of the ventral femur from previous surgery is present. Our study introduced a suggested landmark located even higher along the dorsal cortex (75 mm above the joint line), which is independent of femoral notching. However, accessing the dorsal cortex of the distal femur requires meticulous preparation and the near absence of the distal femur, which commonly occurs in cases of severe periprosthetic fractures or malignant tumours requiring complete prosthetic reconstruction of the distal femur.21,22

Even though axial alignment may be normal, internal component rotation is a predominant cause of patellofemoral complications. Berger et al23 showed that small amounts of combined internal rotation (tibial plus femoral component) of 1° to 4° are associated with lateral tracking and patellar tilting, while moderate (3° to 8°) and severe (7° to 17°) combined component internal rotation are correlated with patellar subluxation and early patellar dislocation or late patellar prosthesis failure. The severity of the patellofemoral problem was directly proportional to the amount of internal component rotation.23 Similar results were reported by Matsuda et al,24 who found a statistically significant correlation between internal component rotation and patellar maltracking.

In revision situations with significant bone loss or destruction, the aforementioned landmarks may not be available, posing challenges in accurately determining the rotational axis of the distal femur.25-28 There were no outliers in the box-plot model evaluating DCL to sTEA angles. Clinically, it is noteworthy that 13 out of 75 measurements showed deviations greater than 4° from the mean of 9.47° external rotation between DCL and sTEA. According to Berger et al,15 this could result in complications with femoral component rotation. The minimum observed external rotation between DCL and sTEA was 1.7° and the maximum was 16.3°. Ultimately, the method allows the surgeon to identify the component rotation, which may be sufficient for patella tracking, but the tracking needs to be analyzed throughout the knee’s ROM before placing the final components.

There are limitations to our study. First, all CT scans analyzed involved patients with severe osteoarthritis who required primary TKA, and bony morphology changes in arthritic knees have been documented in the literature.29 Second, the study’s sample size of 75 CT scans is limited, necessitating further research to confirm our findings. Third, and most importantly, the reliability of the landmark was not investigated in a real surgical setting, meaning that identification of the landmark under surgical conditions might yield different results.

In conclusion, the DCL at 75 mm above the joint line can be measured reproducibly and is approximately 10° externally rotated to the sTEA. This may serve as a valuable landmark for determining femoral component rotation in revision TKA with significant bone loss, when the epicondyles are difficult to assess radiologically, or when the epicondyles are absent. Surgeons should be aware that there are outliers in this study in up to 17% and the trochlea design of the of the implant does not match the natural knee.


Correspondence should be sent to Mikhail Salzmann. E-mail:

References

1. Perka C , Tohtz S , Matziolis G . Axial correction in knee revision arthroplasty . Orthopade . 2006 ; 35 ( 2 ): 136 142 . Crossref PubMed Google Scholar

2. Putman S , Boureau F , Girard J , Migaud H , Pasquier G . Patellar complications after total knee arthroplasty . Orthop Traumatol Surg Res . 2019 ; 105 ( 1S ): S43 S51 . Crossref PubMed Google Scholar

3. Skowronek P , Arnold M , Starke C , et al. Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review . Knee Surg Sports Traumatol Arthrosc . 2021 ; 29 ( 3 ): 772 782 . Crossref PubMed Google Scholar

4. Aglietti P , Sensi L , Cuomo P , Ciardullo A . Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis . Clin Orthop Relat Res . 2008 ; 466 ( 11 ): 2751 2755 . Crossref PubMed Google Scholar

5. Nodzo SR , Franceschini V , Cruz DS , Gonzalez Della Valle A . The flexion space is more reliably balanced when using the transepicondylar axis as compared to the posterior condylar line . Knee Surg Sports Traumatol Arthrosc . 2018 ; 26 ( 11 ): 3265 3271 . Crossref PubMed Google Scholar

6. Franceschini V , Nodzo SR , Gonzalez Della Valle A . Femoral component rotation in total knee arthroplasty: a comparison between transepicondylar axis and posterior condylar line referencing . J Arthroplasty . 2016 ; 31 ( 12 ): 2917 2921 . Crossref PubMed Google Scholar

7. Parratte S , Ollivier M , Argenson J-N . Primary total knee arthroplasty for acute fracture around the knee . Orthop Traumatol Surg Res . 2018 ; 104 ( 1S ): S71 S80 . Crossref PubMed Google Scholar

8. Hube R , Matziolis G , Kalteis T , Mayr HO . TKA revision of semiconstraint components using the 3-step technique . Oper Orthop Traumatol . 2011 ; 23 ( 1 ): 61 69 . Crossref PubMed Google Scholar

9. Klug A , Gramlich Y , Rudert M , et al. The projected volume of primary and revision total knee arthroplasty will place an immense burden on future health care systems over the next 30years . Knee Surg Sports Traumatol Arthrosc . 2021 ; 29 ( 10 ): 3287 3298 . Crossref PubMed Google Scholar

10. Ackerman IN , Busija L , Lorimer M , de Steiger R , Graves SE . Monitoring the lifetime risk of revision knee arthroplasty over a decade . Bone Joint J . 2022 ; 104-B ( 5 ): 613 619 . Crossref PubMed Google Scholar

11. Sathappan SS , Tan MWP , Ginat D , Walsh MG , Schweitzer ME , Di Cesare PE . Correlation between the distal anterior femoral cortical axis and femoral rotational alignment: an anatomic study . J Orthop Surg (Hong Kong) . 2016 ; 24 ( 2 ): 198 203 . Crossref PubMed Google Scholar

12. World Medical Association . World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects . JAMA . 2013 ; 310 ( 20 ): 2191 2194 . Crossref PubMed Google Scholar

13. Oussedik S , Abdel MP , Victor J , Pagnano MW , Haddad FS . Alignment in total knee arthroplasty . Bone Joint J . 2020 ; 102-B ( 3 ): 276 279 . Crossref PubMed Google Scholar

14. MacDessi SJ , Oussedik S , Abdel MP , Victor J , Pagnano MW , Haddad FS . The language of knee alignment: updated definitions and considerations for reporting outcomes in total knee arthroplasty . Bone Joint J . 2023 ; 105-B ( 2 ): 102 108 . Crossref PubMed Google Scholar

15. Berger RA , Rubash HE , Seel MJ , Thompson WH , Crossett LS . Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis . Clin Orthop Relat Res . 1993 ; 286 : 40 47 . PubMed Google Scholar

16. Rajgopal A , Sudarshan P , Kumar S , Aggarwal K . Failure modes in malrotated total knee replacement . Arch Orthop Trauma Surg . 2023 ; 143 ( 5 ): 2713 2720 . Crossref PubMed Google Scholar

17. Stoeckl B , Nogler M , Krismer M , Beimel C , de la Barrera J-L , Kessler O . Reliability of the transepicondylar axis as an anatomical landmark in total knee arthroplasty . J Arthroplasty . 2006 ; 21 ( 6 ): 878 882 . Crossref PubMed Google Scholar

18. Fitz DW , Johnson DJ , Hartwell MJ , Sullivan R , Keller TJ , Manning DW . Relationship of the posterior condylar line and the transepicondylar axis: a CT-based evaluation . J Knee Surg . 2020 ; 33 ( 7 ): 673 677 . Crossref PubMed Google Scholar

19. Victor J . Rotational alignment of the distal femur: a literature review . Orthop Traumatol Surg Res . 2009 ; 95 ( 5 ): 365 372 . Crossref PubMed Google Scholar

20. Yoshino N , Takai S , Ohtsuki Y , Hirasawa Y . Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees . J Arthroplasty . 2001 ; 16 ( 4 ): 493 497 . Crossref PubMed Google Scholar

21. Aebischer AS , Hau R , de Steiger RN , Holder C , Wall CJ . Distal femoral arthroplasty for native knee fractures: results from the australian orthopaedic association national joint replacement registry . Bone Joint J . 2022 ; 104-B ( 7 ): 894 901 . Crossref PubMed Google Scholar

22. Mancuso F , Beltrame A , Colombo E , Miani E , Bassini F . Management of metaphyseal bone loss in revision knee arthroplasty . Acta Biomed . 2017 ; 88 ( 2S ): 98 111 . Crossref PubMed Google Scholar

23. Berger RA , Crossett LS , Jacobs JJ , Rubash HE . Malrotation causing patellofemoral complications after total knee arthroplasty . Clin Orthop Relat Res . 1998 ; 356 : 144 153 . Crossref PubMed Google Scholar

24. Matsuda S , Miura H , Nagamine R , Urabe K , Hirata G , Iwamoto Y . Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees . Am J Knee Surg . 2001 ; 14 ( 3 ): 152 156 . PubMed Google Scholar

25. Engh GA , Parks NL . The management of bone defects in revision total knee arthroplasty . Instr Course Lect . 1997 ; 46 : 227 236 . PubMed Google Scholar

26. Mantas JP , Bloebaum RD , Skedros JG , Hofmann AA . Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplasty . J Arthroplasty . 1992 ; 7 ( 4 ): 531 535 . Crossref PubMed Google Scholar

27. Rorabeck CH , Smith PN . Results of revision total knee arthroplasty in the face of significant bone deficiency . Orthop Clin North Am . 1998 ; 29 ( 2 ): 361 371 . Crossref PubMed Google Scholar

28. Clement ND , Avery P , Mason J , Baker PN , Deehan DJ . First-time revision knee arthroplasty using a hinged prosthesis: Temporal trends, indications, and risk factors associated with re-revision using data from the national joint registry for 3,855 patients . Bone Joint J . 2023 ; 105-B ( 1 ): 47 55 . Crossref PubMed Google Scholar

29. Nagamine R , Miura H , Inoue Y , et al. Reliability of the anteroposterior axis and the posterior condylar axis for determining rotational alignment of the femoral component in total knee arthroplasty . J Orthop Sci . 1998 ; 3 ( 4 ): 194 198 . Crossref PubMed Google Scholar

Author contributions

M. Salzmann: Conceptualization, Formal analysis, Validation, Writing – original draft, Writing – review & editing

E. Kropp: Validation, Conceptualization, Formal analysis, Writing – review & editing

R. Prill: Data curation, Conceptualization, Supervision, Validation, Writing – review & editing

N. Ramadanov: Validation, Writing – original draft, Writing – review & editing

M. Adriani: Data curation, Validation, Writing – review & editing

R. Becker: Conceptualization, Supervision, Writing – review & editing

Funding statement

The author(s) received no financial or material support for the research, authorship, and/or publication of this article, other than the funding of the open access fee, as disclosed below.

ICMJE COI statement

The author(s) received no financial or material support for the research, authorship, and/or publication of this article.

Data sharing

The datasets generated and analyzed in the current study are not publicly available due to data protection regulations. Access to data is limited to the researchers who have obtained permission for data processing. Further inquiries can be made to the corresponding author.

Ethical review statement

As all CT scan data was used from the beginning anonymously and cannot be re-allocated at any time, no ethical approval or written informed consent was needed.

Open access funding

The open access fee for this paper was supported by the German Research Association (DFG).

© 2024 Salzmann et al. This article is distributed under the terms of the Creative Commons Attributions (CC BY 4.0) licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium or format, provided the original author and source are credited.