header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Research

IN VITRO EVALUATION OF STRAIN ON A SPINE SEGMENT USING A NON-CONTACT MEASUREMENT TECHNIQUE

European Orthopaedic Research Society (EORS) 2016, 24th Annual Meeting, 14–16 September 2016. Part 1.



Abstract

The causes of spine disease are often biomechanical ones (e.g. disc degeneration, vertebral fracture). Currently, a deep investigation of the spine biomechanics is missing, due to the high complexity of the spine system (Fung 1980, Brandolini, Cristofolini et al. 2014): vertebrae and intervertebral discs. Recently, the Digital Image Correlation allowed measuring in vitrothe displacement and strain on the surface of soft and hard tissues, upon a specific non-invasive preparation of their surface with a speckle pattern (Palanca, Tozzi et al. 2016). The aim of this explorative work was to evaluate the deformation on spine segments, being able to distinguish between hard and soft tissue in the elastic regime and up to fracture.

Segment of four vertebrae were extracted from porcine spines. All ligaments and muscles were removed, without damaging the spine segment (vertebrae and intervertebral discs). A suitable non-conventional white-on-black speckle pattern was prepared on the surface with airbrush airgun to track the movements of the specimen with DIC (Lionello, Sirieix et al. 2014). The endplates of the extreme vertebrae were potted in poly-methyl-methacrylate. The spine segments were tested in pure axial loading with cycles of increasing magnitude, up to fialure. A commercial 3D-DIC (Dantec Dynamics, Denmark) was used. In the present configuration, it allowed a resolution of 30 micrometers. It was used to measure the displacements and strains in a full-field and contactless way on the frontal surface of the spine segments.

DIC allowed measuring with success the displacement and strain during the entire test, in the elastic regime and up to failure. The displacements and strains could be measured on the entire specimen, both in the vertebrae (hard tissue) and in the intervertebral discs (soft tissue). The axial strain evaluated prior to failure was close to 10’000 microstrain on the vertebral body surface and exceed 70’000 microstrain on the intervertebral discs, where failure was localized.

The pattern, prepared in a dedicated way showed its suitability for both the bone and the disc. The evaluated failure strains were in agreement with the literature (Bayraktar, Morgan et al. 2004) (Spera, Genovese et al. 2011). To the authors' best knowledge, this kind of measurement including strain on soft and hard tissue simultaneously has never been performed before. This work showed the capability of DIC in providing full-field measures on the surface with complex geometry, such as the spine. The assertion of these potentialities could open the way to further application of DIC to study the behaviour of human spines, including improvement of spinal fixation devices.