Abstract
Blood metal ion sampling can help detect poorly functioning metal-on-metal hip arthroplasties (MoMHA's) requiring revision. Little is known about the variation in these levels following bearing exchange. This study aimed to determine the changes that occur in blood and urine metal ion concentrations following MoMHA revision.
A single-centre prospective cohort study was undertaken between 2005 and 2012 of patients with failing large-diameter MoMHA's and high blood metal ions requiring revision to non-metal-on-metal articulations. All patients had normal renal function. Whole blood and urine were collected for metal ion analysis preoperatively and regularly following revision.
Twenty-three MoMHAs (21 hip resurfacings and 2 total hip arthroplasties; mean age 56.0 years and 65% female) were revised at a mean time of 7.9 years (range 2.0–14.5 years) from primary surgery. All revisions were performed by the senior author using primary total hip implants (12 ceramic-on-polyethylene bearings, 10 oxinium-on-polyethylene bearings, and 1 metal-on-polyethylene bearing implanted). Mean (range) metal ion concentrations pre-revision were: blood cobalt 13.9µg/l (1.32–74.7µg/l), blood chromium 8.9µg/l (1.29–57.3µg/l), urine cobalt 104.6µg/24 hours (4.35–747.3µg/24 hours), urine chromium 33.2µg/24 hours (4.39–235.4µg/24 hours). After revision the mean metal ion concentrations (percentage of pre-revision values) were: blood cobalt at 2 days=10.7µg/l (77%), 6 days=7.7µg/l (55%), 2 months=3.4µg/l (24%), 1 year=1.0µg/l (7%), 2 years=0.42µg/l (3%); blood chromium at 2 days=8.7µg/l (98%), 6 days=5.5µg/l (62%), 2 months=2.2µg/l (25%), 1 year=1.5µg/l (16%), 2 years=0.97µg/l (11%); urine cobalt at 2 days=31.9µg/24 hours (30%), 6 days=21.5µg/24 hours (21%), 2 months=6.1µg/24 hours (6%), 1 year=0.99µg/24 hours (1%), 2 years=0.61µg/24 hours (1%); urine chromium at 2 days=34.4µg/24 hours (103%), 6 days=15.8µg/24 hours (48%), 2 months=9.3µg/24 hours (28%), 1 year=2.8µg/24 hours (8%), 2 years=1.9µg/24 hours (6%).
Following MoM revision cobalt levels decline rapidly in an exponential pattern with a single rate of decay through the 2 year period, reaching reference levels within the first year. Chromium follows a similar pattern but starts lower and takes longer. Renal response to cobalt returns to reference level within days of revision.