General Orthopaedics

10 YEAR RESULTS FOR THE PRESS FIT CONDYLAR SIGMA TOTAL KNEE ARTHROPLASTY

Combined Services Orthopaedic Society (CSOS) - 32nd Meeting



Abstract

The DuPuy Sigma total knee arthroplasty (TKA) is a modification of the well-established Press Fit Condylar (PFC) TKA and is used extensively in the UK and worldwide. This study reports the first 10-year clinical and radiological follow-up data for the Sigma PFC.

A total of 235 consecutive Sigma TKAs were performed in 203 patients between October 1998 and October 1999, in our unit. Patients were seen at a specialist nurse-led clinic 1 week before admission and at 6 months, 18 months, 3 years, 5 years and 7-10 years after surgery. Data was recorded prospectively at each clinic visit.

Of 235 knees, 171 (147 patients) were alive at 10 years. Twelve were lost to follow up. Eight knees (3.4%) were revised; four for infection and four underwent isolated change of polyethylene insert. Ten-year survival with an end point of revision for any reason was 95.9%, and with an endpoint of revision for aseptic failure was 98.7%. The mean American Knee Society score was 62 at 8-10 years compared with 31 out of 100 pre-operatively.

Our results show that the PFC Sigma knee arthroplasty performs well over the first 10 years post-implantation.