Abstract
Purpose of the study
To investigate the efficacy of pedicle screw instrumentation in correcting spinal deformity in patients with quadriplegic cerebral palsy. Also to assess quality of life and functional improvement after deformity correction as perceived by the parents of our patients.
Summary of Background Data
All pedicle screw constructs have been commonly used to correct adolescent idiopathic scoliosis. There is limited information on their effectiveness in treating patients with cerebral palsy and neuromuscular scoliosis.
Methods
We reviewed the medical records and serial radiographs of 45 consecutive patients with quadriplegia who underwent spinal arthrodesis using pedicle screw/rod instrumentation and a standardised surgical technique (prospectively collected single surgeon's series). All patients were wheelchair bound with collapsing thoracolumbar scoliosis and pelvic obliquity. Twenty-eight patients had associated sagittal deformities. A telephone survey was performed by an independent investigator to assess parents' perception on surgical outcome.
Results
Thirty-eight patients underwent posterior-only and 7 staged anteroposterior spinal arthrodesis. Mean age at surgery was 13.4 years (range 9-18.3) and mean postoperative follow-up 3.5 years (range 2.8-5). Pedicle screw instrumentation extended from T2/T3 to L5 with bilateral pelvic fixation using iliac bolts. Scoliosis was corrected from mean 82.5° to 21.4° (74.1%). Pelvic obliquity was corrected from mean 24° to 4° (83.3%). In posterior-only procedures, average blood loss was 0.8 blood volumes, ICU stay 3.5 days, and hospital stay 17.6 days. In anteroposterior procedures, average blood loss was 0.9 blood volumes, ICU stay 8.9 days, and hospital stay 27.4 days. Major complications included one deep infection and one re-operation to remove prominent implants but no deaths, no neurological deficit and no detected pseudarthrosis. Parents' survey demonstrated 100% satisfaction rate.
Conclusion
Pedicle screw instrumentation can achieve excellent correction of spinopelvic deformity in quadriplegic cerebral palsy with low complication and re-operation rates and high parent satisfaction. Our study has demonstrated that spinal correction using segmental pedicle screw/rod constructs can be performed safely and with lesser major complications and reoperations compared to the traditionally used Unit rod or hybrid instrumentation. The greater degree of deformity correction and lesser rate of complications and reoperations due to non-union, prominent instrumentation or failed pelvic fixation using a pedicle screw compared to the Unit rod technique should be balanced against the increased implant cost.
Ethics: Audit/service standard in trust
Interest statement: None