Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

HOW TO RESTORE ROTATION CENTRE IN TOTAL HIP ARTHROPLASTY FOR DEVELOPMENTAL DYSPLASIA OF THE HIP WITH THE ASSISTANCE OF 3D PRINTING TECHNOLOGY: A PILOT STUDY

International Society for Technology in Arthroplasty (ISTA) meeting, New Early-Career Webinar Series (NEWS), held online, November 2020.



Abstract

Background

It is technically challenging to restore hip rotation center exactly in total hip arthroplasty (THA) for patients with end-stage osteoarthritis secondary to developmental dysplasia of the hip (DDH) due to the complicated acetabular morphology changes. In this study, we developed a new method to restore hip rotation center exactly and rapidly in THA with the assistance of three dimensional (3-D) printing technology.

Methods

Seventeen patients (21 hips) with end-stage osteoarthritis secondary to DDH who underwent THA were included in this study. Simulated operations were performed on 3-D printed hip models for preoperative planning. The Harris fossa and acetabular notches were recognized and restored to locate acetabular center. The agreement on the size of acetabular cup and bone defect between simulated operations and actual operations were analyzed. Clinical and radiographic outcomes were recorded and evaluated.

Results

The sizes of the acetabular cup of simulated operations on 3-D printing models showed a high rate of coincidence with the actual sizes in the operations(ICC value=0.930) There was no significant difference statistically between the sizes of bone defect in simulated operations and the actual sizes of bone defect in THA(t value=0.03 P value=0.97). The average Harris score of the patients was improved from (38.33±6.07) preoperatively to the last follow-up (88.61±3.44) postoperatively. The mean vertical and horizontal distances of hip rotation center on the pelvic radiographs were restored to (15.12 ± 1.25 mm and (32.49±2.83) mm respectively. No case presented dislocation or radiological signs of loosening until last follow-up.

Conclusions

The application of 3-D printing technology facilitates orthopedists to recognize the morphology of Harris fossa and acetabular notches, locate the acetabular center and restore the hip rotation center rapidly and accurately.