S09.3 SILVER-COATED MEGAENDOPROSTHESIS – A NOVEL TECHNIQUE TO PREVENT IMPLANT ASSOCIATED INFECTIONS



Abstract

Early and late infections are the most uneventfull complications after tumor resection and implantation of a maegaendoprosthesis. Therefore, silver-coating was introduced by our department years ago with successful reduction in infection rates. After promising results in animal and Phase exclusion of side effects in our Phase I trial, we would like to share our knowledge about latest research, especially the actual results of the Phase II study. We included the results off all implanted silver-coated Megaendoprosthesis since introduction in our department. Implantation had to be more than 12 months ago to guarantee a acceptable minimum follow up for calculation of the infection rate. Actually our infection rate lies at 3,1% (N=131) in the prevention group (no previous infection in medical history) and at 19% (N=36) in our “Highest-Risk” and previous infection group. Still no side-effects could be noticed. In one case we examined retrieved samples of three silver-coated Megaendoprosthesis. Macroscopically a leopard shaped figures could be noticed on the silver-coated surface in shiny and dark areas after being implanted in an infected region. Electron microscopy pictures show still intact surface and remaining silver with dark staining. Biofilm formation coulod not be noticed, though some few dead single bacteria could be found without any signs of proliferation or matrix production after adhesion. Signs of biofilm couldn’t be seen anywhere. Despite the discoloration silver is still intact in these areas without any loss of antibacterial properties. Blisterings or even flaking off the silver coating cannot be noticed. The thickness of the silver was not thinned in a significant way leading to a breakdown after a few years.

Up to these days we have no experience in covering the whole prosthesis including the stem in human beings. Concerning osteointegration of silver-coated stems, our animal trial could not prove their effectiveness in comparison to titanium. Pull-out tests showed high significant discrepancies in osteointegration between titanium and silver coated stems in a dog model after a period of 12 months after implantation.

Summarizing we recommend silver as a safe adjuvant therapy in patients undergoing endoprosthetic reconstruction after tumor resection. Intramedullary use of silver can be done only in experimental cases and needs further changes in the technical design of the coating.