Abstract
The treatment of patients with arthritis of the glenohumeral joint with an associated massive irreparable cuff tear is challenging. Since these patients usually have proximal migration of the humerus, the CTA extended head allows a surface with a low coefficient of friction to articulate with the acromion.
Between 2001 and 2006 a total of 48 patients with arthritis of the shoulder joint associated with a massive cuff tear, were treated with a CTA head. The indications for use being Seebauer Type 1a and 1b appearances on x-ray and active abduction of the arm to more than 60° with appropriate analgesia. Preoperatively, a Constant score and an ASES pain and function score were completed as well as standard radiological assessment. These were repeated at follow up. Paired t tests were carried out for all the variables. A Kaplan-Meier survival analysis was performed.
Follow up varied between 2 and 8 years. Improvements in pain, function and all movement parameters were significant at p< 0.001. There was no change in the strength component. Survival analysis showed 94% survival at 8 years (95% CL 8%) there were 2 revisions and 5 deaths. Radiological assessment at follow up revealed no evidence of humeral stem loosening. In 5 (17%) cases however there was evidence of erosion in the surface of the acromion and in 13 (45%) erosion of the glenoid. Finally one component was also seen to have subluxed anteriorly.
This head design has been in use for a number of years. To date there appears to be no reported outcome of their use. This series shows that in an appropriately selected patient a satisfactory clinical outcome can be maintained in the short to medium term. The presence of erosion of the glenoid but also the under surface of the acromion does require continuing monitoring.
The abstracts were prepared by Mr Matt Costa and Mr Ben Ollivere. Correspondence should be addressed to Mr Costa at Clinical Sciences Research Institute, University of Warwick, Clifford Bridge Road, Coventry CV2 2DX, UK.