Abstract
Purpose: Acetabular component revision in the context of large, contained bone defects with less than 50% host-bone-contact traditionally required roof reinforcement or antiprotrusio cages. Trabecular Metal (TM) cups (Zimmer, Warsaw, Indiana) may offer a viable treatment alternative. The objective of this study was to evaluate the clinical and radiological outcome of this mode of treatment.
Method: Fifty-four hip revision acetabular arthroplasty procedures performed with TM cups for contained defects offering ≤50% contact with native bone were prospectively followed. Average follow-up was 45 months (range 24–71). All patients were clinically and radiographically evaluated for evidence of loosening or failure.
Results: Contact with bleeding host bone ranged from 0 to 50% (average 23%). At latest follow up 43 (79.6%) arthroplasties had excellent or good results, 8 (14.8%) cases had medium or fair results and 3 cases (5.6%) had poor results. Two cups failed and had to be revised. Two additional cups had radiological evidence of probable loosening. Overall preliminary survivorship of the revision acetabulae was 96%. Complications included 4 dislocations and 1 sciatic nerve palsy.
Conclusion: Treatment of cavitary defects with less than 50% host-bone contact with using TM cups, without structural support by augments or structural bone grafts, is a viable option.
Correspondence should be addressed to CEO Doug C. Thomson. Email: doug@canorth.org