header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

THE EFFECT OF HAEMATOMA ASPIRATION ON INTRAARTICULAR PRESSURE AND PAIN RELIEF FOLLOWING MASON I RADIAL HEAD FRACTURES



Abstract

Aim of the study: Mason type I radial head fractures are non-displaced fractures and are treated conservatively with early mobilization and excellent results. The aspiration of the accompanying haematoma is advocated by several authors in order to achieve an analgesic effect. The aim of this study was to investigate the effect of haematoma aspiration on intraarticular pressure and on pain relief after Mason I radial head fractures.

Materials and Methods: 10 patients (6 men and 4 women, age 23–47 y), who presented in the emergency department after an elbow trauma. Following plain radiographs that showed a Mason I radial head fracture, the patients were subjected to haematoma paracentesis. Initially, the intraarticular pressure was measured by using the Stryker Intra-Compartmental Pressure Monitor System. Afterwards, aspiration of the haematoma was performed, followed by a new pressure measurement without moving the needle. Finally, a brachial-elbow-wrist back slab was placed and a questionnaire was completed, including among others pain evaluation before and after haematoma aspiration by using an analogue ten point pain scale.

Results: The intraarticular elbow pressure prior to haematoma aspiration varied from 49 mmHg to 120 mmHg (mean 76.9 mmHg), while following aspiration it ranged from 9 mmHg to 25 mmHg (mean 16.7 mmHg). The mean quantity of the aspired blood was 3.45 ml (0.5 ml to 8.5 ml). Finally, the patients reported a pain decrease from 5.5 (4 to 8) before aspiration to 2.8 (1 to 4) after haematoma aspiration. Decrease for both pressure and pain was statistically significant (p< 0.001).

Conclusion: The built of an intraarticular haematoma in the elbow joint following an undisplaced Mason I radial head fracture leads to a pronounced increase of the intraarticular pressure accompanied by intense pain for the patient. The aspiration of the haematoma results in an acute pressure decrease and an immediate patient relief.

Correspondence should be addressed to: EFORT Central Office, Technoparkstrasse 1, CH – 8005 Zürich, Switzerland. Tel: +41 44 448 44 00; Email: office@efort.org

Author: Konstantinos Ditsios, Greece

E-mail: raulgarcia6974@yahoo.com