AN ALTERNATIVE METHOD FOR THE TREATMENT OF DEFECTED TIBIA PSEUDOARTHROSIS USING CIRCULAR FIXATOR



Abstract

Introduction: Treatment of defected pseudoarthrosis tibia remains controversial due to bone loss with/without infection arises from previous interventions. In the present study we evaluated the results of acute shortening and distraction osteogenesis in the treatment of tibia pseudoarthrosis with bone loss.

Material and Methods: Eleven patients were treated with acute shortening and distraction osteogenesis. Mean age and bone loss was 27.5 years (range 10–44) and 8.9 cm (range 3.5–12) respectively. 7 of eleven patients is infected pseudoarthrosis. Enfected patients were type 4A according to Chierny-Mader classification. The 4 of infected patients were treated with two staged procedure. In the first stage antibiotic (teicoplanin) impregnated polymethylmetacrilate beads were placed to the space occurred as a result of excision of sclerotic bone segment and fixation was performed by external fixator or braces. Second stage composed of acute compression (shortening) and distraction osteogenesis. Other 3 infected and noninfected patients were treated with resection, acute shortening and distraction osteogenesis in one stage. In six cases docking site were grafted with autografts. Defects greater than 4 cm were gradually shortened 2mm/day in addition to acute shortening. Limb length inequality was solved with lengthening from proximal tibial corticotomy and achieving union of both sites about the same time.

Results: Mean follow up, external fixator time and external fixator index was 48.3 months (21–80), 8.9 months (6–13) and 1,3 month/cm respectively. results were evaluated according to Paley’s bone and functional evaluation scoring. Eleven patient revealed excellent results with regard to bone evaluation and 10 patient revealed excellent and 1 patient revealed good results in terms of functional evaluation. In one patient fracture at the pseudoartrosis site occurred due to new trauma after removal of the fixator which was treated with circular external fixator. In the another patient, the lengthening regenerate side was low quality bone which need intra-medullary fixation and grafted with autograft.

Conclusion: Acute shortening and distraction osteogenesis is a safe and successful procedure in the treatment of defected tibia pseudoarthrosis and is alternative to other treatments. Acute shortening and distraction osteogenesis was found to be successful and safe with regard to functional results in the treatment of defected tibia pseudoarthrosis. Besides we suggest it as an alternative due to lower rate of complications and less external fix-ator time compared to other Methods: