Abstract
Revision of a failed femoral component in the face of extensive bone loss is a major challenge. When the bone loss extends down below the isthmus it may be difficult to obtain longitudinal stability with a tapered or fully porous coated prosthesis. If subsidence occurs then recurrent dislocation can be an insoluble problem. This study reviews the use of a distally interlocked femoral component designed to address this challenging situation.
We have reviewed 21 cases in which extensive bone loss made the use of an interlocking prosthesis desirable. The average time from surgery was over four years. All patients completed an Oxford hip score and an EO-50. All radiographs were reviewed.
There were 14 males and seven females with an overall average age of 74 years at the time of surgery. Patients had had an average of two previous THR’s, and up to nine previous hip operations. One patient underwent re-revision because of subsidence related to screw cut out. There was one dislocation. Patient satisfaction was high with low Oxford hip scores compared with other revision prostheses, and good EO – 50 ratings.
This type of prosthesis offers a very satisfactory solution to difficult revision situations when bone loss makes the use of regular prostheses difficult. The prosthesis used in this study has a low offset and thus dislocation precautions should be emphasised.
Correspondence should be addressed to Associate Professor N. Susan Stott, Orthopaedic Department, Starship Children’s Hospital, Private Bag 92024, Auckland, New Zealand.