HP13: ION LEVELS IN UNI AND BILATERAL HIP RESURFACING PATIENTS



Abstract

Ion levels in the serum and urine of patients with metal-on-metal hip resurfacing implants can provide a means to monitor bearing wear. This presentation will discuss the current results, now out to 5 years for the Conserve Plus resurfacing. In particular, the effect of bilateral implantation on ion levels was examined

Forty-eight patients were studied. Forty-three of these cases were initially implanted with a unilateral resurfacing. Nine of these cases subsequently were implanted with a resurfacing implant on the contra-lateral side 4 to 48 months following the first implantation (staged implantations). Five cases had bilateral resurfacings done simultaneously. All surgeries were done in one institution by a single surgeon. Serum and urine samples were collected pre-operatively, and at 4 months, 12 months and annually thereafter. The samples were analysed for cobalt and chromium using atomic absorption spectrometry with a detection limit of 0.3 to 0.03ng/ml respectively. The data were compared between the groups and also correlated with UCLA activity scores, cup angle, BMI and component size.

All patients showed a rise in ions following implantation. The simultaneous bilateral levels were higher at all time periods compared with the staged bilaterals monitored at the same time point for the second hip, for example cobalt serum at 12 month uni = 2.24, simultaneous bilat = 2.53, staged bilat = 2.05ng/ml, and at 4 years uni = 1.20, simultaneous bilat = 2.93, staged bilat = 2.27ng/ml. There was no correlation between ion levels and UCLA activity score, gender, component size or cup angle (but only 4 hips had cups > 55 degrees).

Bilateral metal-on-metal hip resurfacings performed simultaneously resulted in higher levels of metal ions, particularly chromium, compared to staged implantations monitored at the same time periods. With the exception of a small number of outliers, the levels in this group of hip resurfacings were within the range of metal levels reported for other metal-on-metal total hips.

The abstracts were prepared by David AF Morgan. Correspondence should be addressed to him at davidafmorgan@aoa.org.au

Declaration of interest: b