Modular femoral stem provides significant flexibility in total hip revision arthroplasty. There have been few clinical studies that have dealt with modular stem. We have evaluated the clinical and radiographic performance of 59 patients with distal fix modular Link MP stem. The average follow-up period was 6.4 years. The average Harris hip score was improved from 47 to 87.6. Of 19 patients with trochanteric osteotomy, greater trochanter was displaced in four patients. Re-revision was done to five patients. Three were for subsidence, one of them showed dissociation of the coupling part and the other two were for a nonunion of osteotomy site. There was no statistical relation (p=0.40) between stem subsidence and bone deficiency; the subsidence may have been too small for the canal. As a result of last follow-up, survival rate was 91.5 %(CI 95%, 89–101), but there was no case of recurrent dislocation or femoral stem fracture.
Correspondence should be addressed to ISTA Secretariat, PO Box 6564, Auburn, CA 95604, USA. Tel: 1-916-454-9884, Fax: 1-916-454-9882, Email: ista@pacbell.net