VARIABILITY OF ROTATIONAL POSITION OF THE TIBIA AND POSTOPERATIVE CORONAL ALIGNMENT IN NAVIGATED TKR



Abstract

The aim of this study was to evaluate the rotational axis of the tibia and the association of its axis to tibial coronal alignment after TKR.

TKRs were performed using navigated mobile bearing system (40 knees), conventional mobile bearing (48 knees) and conventional fixed bearing (40 knees) and preoperative and postoperative CT scans were assessed using 3D image reconstruction-analysis program. The tibial AP axis which was defined as the line connecting the middle of the PCL and the medial edge of the patellar tendon attachment was measured relative to the AP axis of distal femur preoperatively and postoperatively, as well as the coronal angle of the tibia and posterior slope. The tibial coronal alignments in navigation, postoperative plain radiograph and CT were compared.

The AP axis of the tibia was in 2.10° internally rotated position relative to the AP axis of the femur preoperatively and 3.54° postoperatively (range, 19.5° internal rotation to 16.8° external rotation). The coronal angle of the tibia was 0.46° varus on plain radiograph, 0.72° varus on CT, 0.37° valgus in navigation (p=0.005). Posterior slope was 2.53° on plain radiograph and 0.67° in navigation (p< 0.001). There was no correlation between postoperative rotational position of the tibia relative to the femur and the difference in the tibial coronal angle between navigation data and CT.

The proposed anteroposterior axis of the tibia centered between 0 to 5 degrees internally rotated position relative to the femur but showed wide range of deviation. The rotation angle of the tibial cutting in navigated TKR did not influence on the postoperative measurement discrepancy between navigation and CT.

Correspondence should be addressed to ISTA Secretariat, PO Box 6564, Auburn, CA 95604, USA. Tel: 1-916-454-9884, Fax: 1-916-454-9882, Email: ista@pacbell.net