Abstract
Failed internal fixation of hip fracture is a problem with varied aetiology. This becomes more complex when associated with infection. Total hip arthroplasty (THA) remains the only option to restore hip biomechanics when there is partial/complete head destruction associated with it.
A retrospective review was performed for 22 consecutive patients of THA following failed infected internal fixation between Sept. 2001 and Nov. 2007. There were 11 dynamic hip screw failures for intertrochanteric fractures, 6 failed osteotomies following proximal femoral fractures, and 5 failed screw fixations for transcervical fractures. The average age of the patients were 48.5years and average follow up period was 3.5 years (5months – 7.5years). All the patients have undergone two stage revision surgeries. The average Harris Hip Score improved from 35.5 to 82.8 at the latest follow up. None of the patients had recurrence of infection. One patient developed sciatic nerve palsy, recovered partially at 1 year following surgery. The results were comparable to primary arthroplasty in femoral neck fractures.
THA is a useful salvage procedure for failed infected internal fixation of hip fractures. Extreme care must be taken to avoid fracture and penetration of femoral shaft in such cases. Auto graft, allograft and special components like multihole cup, narrow stem should be available for reconstruction in difficult cases.
Correspondence should be addressed to ISTA Secretariat, PO Box 6564, Auburn, CA 95604, USA. Tel: 1-916-454-9884, Fax: 1-916-454-9882, Email: ista@pacbell.net