Abstract
Total Elbow arthroplasty can be a valuable treatment option in the painful or stiff elbow but outcomes have been disappointing previously. The history of total elbow arthroplasty has been disappointing in the past. Implants initially were a coupled articulation and were a rigid hinge. There was then a move to resurfacing type of designs although there was an issue with instability postoperatively with these implants. The semiconstrained coupled implant was developed in the mid 1970s by Coonrad. The idea behind the implant was that the loose polyethylene coupling provides inherent stability while decreasing the amount of loosening that was seen with the rigid hinge implants previously. We are reporting our results of our experience with a single type of semiconstrained implant that has been used in our unit since 1999.
A semiconstrained total elbow arthroplasty was performed in thirteen patients over a period of 7 years period in our unit. Mean age at time of surgery was 60 years (44–70) M:F ratio 11:2. The aetiology of the joint pathology was Rheumatoid Arthritis (n= 10), psoriatic arthritis (n= 2) & posttraumatic (n =1).
The patients were followed up for a mean duration of 4.5 years. They were assessed for range of motion, Mayo elbow function scores and radiographic evaluation and complication rate. 9 of the 13 elbows had a good to excellent result. There were 5 complications overall. There was two ulnar neuropathies that eventually resolved and one ulnar component that had to be revised 2 weeks after initial insertion. 3 had condylar fractures none of which required further operation. One patient had evidence of radiographic loosening but was asymptomatic.
In our experience the semiconstrained total elbow replacement is a valuable option in the treatment of painful stiff the elbow.
Correspondence should be addressed to Mr Richard Wallace at Musgrave Park Hospital, 20 Stockman’s Lane, Belfast BT9 7JB, Northern Ireland.