Abstract
Purpose: The mechanical behavior of human scapholunate ligaments is not described well in the literature regarding torsion. Presently, intact scapholunate specimens were mechanically tested in torsion to determine if any tensile forces were generated as a result.
Method: Scapholunate specimens (n=19) were harvested and inspected visually. Scaphoid and lunate bones were potted in square chambers using epoxy cement. The interposing ligaments remained exposed. Specimens were mounted in a specially designed test jig and remained at a fixed axial length during testing. Using angular displacement control, ligaments were subjected to a torsional motion regime that included cyclic preconditioning (25 cycles, 1 Hz, triangular wave, 5 deg max), ramp-up to 15 deg at 180 deg/min, stress relaxation for 120 sec duration, ramp-down to 0 angulation at 180 deg/min, rest period for 5–10 minutes, and torsion-to-failure at 180 deg/min. Torque and axial tension were monitored simultaneously.
Results: Tests showed a coupled linear relationship between applied torsion and the resultant tensile forces generated for the ligament during ramp-up (Torsion/Tension Ratio = 38.86 +/− 29.00 mm, Linearity Coefficient R-squared = 0.89 +/− 0.15, n=19), stress relaxation (Ratio = 23.43 +/− 15.84 mm, R-squared = 0.90 +/− 0.09, n=16), and failure tests (Ratio = 38.81 +/− 26.39 mm, R-squared = 0.77 +/− 0.20, n=16). No statistically significant differences were detected between the Torsion/Tension ratios (p=0.13) or between the linearity (R-squared) of the best-fit lines (p> 0.085).
Conclusion: A strong linear relationship between applied torsion and resulting tensile forces for the ligament was exhibited during all testing phases. This may suggest that there is interplay between torsion and tension in both the stabilization of the scapholunate ligament during normal physiological motion and during resistance to injury processes. This is the first report in the literature of the coupling of torsion with tension for the scapholunate ligament.
Correspondence should be addressed to Meghan Corbeil, Meetings Coordinator Email: meghan@canorth.org