Abstract
Purpose: We report the 10 to 13 year results of the PFC knee system at our institution.
Method/Results: Between 1992 and 1995 97 PFC primary knee arthroplasties were performed consecutively in 82 patients. 32 patients have subsequently died (37 knees) and four (4 knees) are lost to follow-up. Clinical and radiological review of 46 patients (56 knees) was performed at a mean of 11.1 years post-operatively. Outcome was assessed using the Charnley modification of the Merle D’Aubigne score, with a median of 5 for pain and 4 for function. Radiological failure was defined as progressive radiolucency (1 case), lysis (1 case) or subsidence (1 case). Polyethylene wear was detectable in 10 cases, with > 50% in two. There was 100% survivorship with revision for aseptic loosening as an endpoint. There has been one revision for infection and one patella resurfacing, giving a 98% survivorship with no re-operation. In addition one periprosthetic fracture above a well fixed femoral component, required a supracondylar nail.
Conclusions: The PFC gives excellent outcome and survivorship at 13 years, regardless of the experience of the operating surgeon. This demonstrates that with careful training the PFC is a reliable knee replacement in the long-term for trainers and trainees alike.
Correspondence should be addressed to Mr Tim Wilton, BASK at the Royal College of Surgeons, 35–43 Lincoln’s Inn Fields, London WC2A 3PE.