Abstract
Rotator cuff or long head of biceps tendon tears are common in patients with degenerative shoulder rotator cuff disease. Most often they are investigated with an MRI scan. Diagnosis prior to surgery is useful for the appropriate surgical planning.
We present 63 consecutive patients who had arthroscopic shoulder surgery and prior to that had MRI investigation between 1994 and 2001. Their medical records were reviewed; arthroscopic operative findings as well as the report of the MRI scan were recorded and compared retrospectively. The aim of our study was to assess the accuracy of MRI findings comparing the arthroscopic ones regarding rotator cuff and biceps tendon pathology.
There were 63 patients with mean age 58 years. All of these had MRI scan investigation and the waiting time prior to surgery was 10 months. It was found that there were 6 false (−)ve, 1 false (+)ve and two cases with full thickness cuff tears which were reported as probable tears. Further to that, there were 11 frayed biceps tendons, 8 partially ruptured, 3 subluxed, 4 complete ruptures and 1 SLAP lesion. All biceps lesions were not commented in the MRI scan reports.
MRI scan is very sensitive detecting soft tissue pathology in shoulder investigation. However, even on that basis, rotator cuff and in particular biceps tendon pathology can be missed. The shoulder arthroscopy is the best method to accurately diagnose those lesions. However, it should be noted that often the surgeon has got to alter to working surgical plan in order to address the problem intraoperatively.
In this study it is demonstrated the MRI scan often misses rotator cuff or long head of biceps tendon pathology. The most sensitive method for the diagnosis of it is the shoulder arthroscopy, which address its treatment in the same time.
These abstracts were prepared by Mr Cormac Kelly. Correspondence should be addressed to him c/o British Orthopaedic Association, Royal College of Surgeons, 35-43 Lincoln’s Inn Fields, London WC2A 3PN.