Advertisement for orthosearch.org.uk
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 87-B, Issue 9 September 2005

Head, hand and heart Pages 1169 - 1170
Access Required
D. H. A. Jones
View article
Download PDF

Review Article
Access Required
K. Trieb
View article
Download PDF

Access Required
W. J. Harrison
View article
Download PDF

Annotation
Access Required
J. L. Sher M. R. Reed P. Calvert W. A. Wallace A. Lamb
View article
Download PDF

Access Required
D. Pitts D. I. Rowley J. L. Sher
View article
Download PDF

J.-N. Argenson E. Ryembault X. Flecher N. Brassart S. Parratte J.-M. Aubaniac
View article
Download PDF

Using radiography and computer tomography (CT) we studied the morphology of 83 hips in 69 Caucasian adults with osteoarthritis secondary to developmental dysplasia of the hip (DDH). A previously published series of 310 hips with primary osteoarthritis was used as a control group. According to the Crowe classification, 33 of the dysplastic hips were graded as class I, 27 as class II and 23 as class III or class IV.

The intramedullary femoral canal had reduced mediolateral and anteroposterior dimensions in all groups compared with the control group. Only in Crowe class II hips was the femoral neck-shaft angle increased. The proximal femur had more anteversion in all the developmental dysplasia of the hip groups, ranging from 2° to 80°. Templated measurement of acetabular dimensions for plain radiography closely matched measurements taken by CT.

The results of our study confirm the observations previously confined to the Japanese population.


E. Fawzy G. Mandellos R. De Steiger P. McLardy-Smith M. K. D. Benson D. Murray
View article
Download PDF

We followed up 76 consecutive hips with symptomatic acetabular dysplasia treated by acetabular shelf augmentation for a mean period of 11 years. Survival analysis using conversion to hip replacement as an end-point was 86% at five years and 46% at ten years. Forty-four hips with slight or no narrowing of the joint space pre-operatively had a survival of 97% at five and 75% at ten years. This was significantly higher (p = 0.0007) than that of the 32 hips with moderate or severe narrowing of the joint-space, which was 76% at five and 22% at ten years. There was no significant relationship between survival and age (p = 0.37) or the pre- and post-operative centre-edge (p = 0.39) and acetabular angles (p = 0.85).

Shelf acetabuloplasty is a reliable, safe procedure offering medium-term symptomatic relief for adults with acetabular dysplasia. The best results were achieved in patients with mild and moderate dysplasia of the hip with little arthritis.


P. Mattsson A. Alberts G. Dahlberg M. Sohlman H. C. Hyldahl S. Larsson
View article
Download PDF

We undertook a multicentre, prospective study of a series of 112 unstable trochanteric fractures in order to evaluate if internal fixation with a sliding screw device combined with augmentation using a calcium phosphate degradable cement (Norian SRS) could improve the clinical, functional and radiological outcome when compared with fractures treated with a sliding screw device alone. Pain, activities of daily living, health status (SF-36), the strength of the hip abductor muscles and radiological outcome were analysed.

Six weeks after surgery, the patients in the augmented group had significantly lower global and functional pain scores (p < 0.003), less pain after walking 50 feet (p < 0.01), and a better return to the activities of daily living (p < 0.05). At follow-up at six weeks and six months, those in the augmented group showed a significant improvement compared with the control group in the SF-36 score. No other significant differences were found between the groups. We conclude that augmentation with calcium phosphate cement in unstable trochanteric fractures provides a modest reduction in pain and a slight improvement in the quality of life during the course of healing when compared with conventional fixation with a sliding screw device alone.


M. Pospischill K. Knahr
View article
Download PDF

We carried out a clinical and radiological review of 103 cementless primary hip arthroplasties with a tapered rectangular grit-blasted titanium press-fit femoral component and a threaded conical titanium acetabular component at a mean follow-up of 14.4 years (10.2 to 17.1).

The mean Harris hip score at the last follow-up was 89.2 (32 to 100). No early loosening and no fracture of the implant were found. One patient needed revision surgery because of a late deep infection. In 11 hips (10.7%), the reason for revision was progressive wear of the polyethylene liner. Exchange of the acetabular component because of aseptic loosening without detectable liner wear was carried out in three hips (2.9%).

After 15 years the survivorship with aseptic loosening as the definition for failure was 95.6% for the acetabular component and 100% for the femoral component.


N. Hogan A. Azhar O. Brady
View article
Download PDF

We have evaluated the effect of vacuum aspiration of the iliac wing on the osseointegration of cement into the acetabulum. We entered a total of 40 patients undergoing primary total hip arthroplasty into two consecutive study groups. Group 1 underwent acetabular cement pressurisation for 60 seconds before insertion of the acetabular component. Group 2 had the same pressurisation with simultaneous vacuum suction of the ilium using an iliac-wing aspirator. Standard post-operative radiographs were reviewed blindly to assess the penetration of cement into the iliac wing. Penetration was significantly greater in the group with aspiration of the iliac wing.


B. M. Wroblewski P. D. Siney P. A. Fleming
View article
Download PDF

We report the results of our continued review of 11 total hip arthroplasties using 22.225 mm alumina ceramic femoral heads on a Charnley flanged stem, articulating with chemically cross-linked polyethylene. There was an initial bedding-in of up to 0.41 mm at the articular surface in the first two years. This had not progressed further, at a minimum follow-up of 15 years. Radiographically no femoral or acetabular component showed loosening or osteolysis.


P.-Y. Sheng E. Jämsen M. U. K. Lehto Y. T. Konttinen J. Pajamäki P. Halonen
View article
Download PDF

We report a consecutive series of 16 revision total knee arthroplasties using the Total Condylar III system in 14 patients with inflammatory arthritis which were performed between 1994 and 2000. There were 11 women and three men with a mean age of 59 years (36 to 78). The patients were followed up for 74 months (44 to 122).

The mean pre-operative Knee Society score of 37 points (0 to 77) improved to 88 (61 to 100) at follow-up (t-test, p < 0.001) indicating very good overall results. The mean range of flexion improved from 62° (0° to 120°) to 98° (0° to 145°) (t-test, p < 0.05) allowing the patients to stand from a sitting position. The mean Knee Society pain score improved from 22 (10 to 45) to 44 (20 to 50) (t-test, p < 0.05). No knee had definite loosening, although five showed asymptomatic radiolucent lines. Complications were seen in three cases, comprising patellar pain, patellar fracture and infection.

These results suggest that the Total Condylar III system can be used successfully in revision total knee arthroplasty in inflammatory arthritis.


N. Bottomley A. Williams R. Birch A. Noorani A. Lewis J. Lavelle
View article
Download PDF

We reviewed the relationship between the pattern of damage to the posterolateral corner of the knee and the position of the common peroneal nerve in 54 consecutive patients with posterolateral corner disruption requiring surgery. We found that 16 of the 18 patients with biceps avulsions or avulsion-fracture of the fibular head had a displaced common peroneal nerve. The nerve was pulled anteriorly with the biceps tendon. None of the 34 proximal injuries resulted in an abnormal nerve position.

Whenever bone or soft-tissue avulsion from the fibular head is suspected, the surgeon should expect an abnormal position of the common peroneal nerve and appreciate the increased risk of iatrogenic damage.


R. W. Brouwer S. M. A. Bierma-Zeinstra A. J. van Koeveringe J. A. N. Verhaar
View article
Download PDF

Our aim was to compare the degree of patellar descent and alteration in angle of the inclination of the tibial plateau in lateral closing-wedge and medial opening-wedge high tibial osteotomy (HTO) in 51 consecutive patients with osteoarthritis of the medial compartment and varus malalignment. Patellar height was measured by the Insall-Salvati (IS) and the Blackburne-Peel (BP) ratios. The tibial inclination was determined by the Moore-Harvey (MH) method. Multivariate linear regression analysis was used to determine the influence of the type of HTO (closing vs opening wedge) on the post-operative patellar height or tibial inclination. The intra- and interobserver variability of these methods was determined before operation and at follow-up at one year.

After an opening-wedge HTO the patellar height was significantly more decreased (mean post-operative difference: IS = 0.15; 95% confidence interval (CI) 0.06 to 0.23; BP = 0.11; 95% CI 0.05 to 0.18) compared with a closing-wedge HTO.

The angle of tibial inclination differed significantly (mean post-operative difference MH = −6.40°; 95% CI −8.74 to −4.02) between the two HTO techniques, increasing after opening-wedge HTO and decreasing after closing-wedge HTO.

There was no clinically-relevant difference in the intra- and interobserver variability of measurements of patellar height either before or after HTO.


P. Gaston E. M. Will J. F. Keating
View article
Download PDF

We assessed the functional outcome following fracture of the tibial plateau in 63 consecutive patients. Fifty-one patients were treated by internal fixation, five by combined internal and external fixation and seven non-operatively. Measurements of joint movement and muscle function were made using a muscle dynamometer at three, six and 12 months following injury. Thirteen patients (21%) had a residual flexion contracture at one year. Only nine (14%) patients achieved normal quadriceps muscle strength at 12 months, while 19 (30%) achieved normal hamstring muscle strength. Recovery was significantly slower in patients older than 40 years of age. We conclude that there is significant impairment of movement and muscle function after fracture of the tibial plateau and that the majority of patients have not fully recovered one year after injury.


M. H. Mehta
View article
Download PDF

This prospective study of 136 children with progressive infantile scoliosis treated under the age of four years, and followed up for nine years, shows that the scoliosis can be reversed by harnessing the vigorous growth of the infant to early treatment by serial corrective plaster jackets.

In 94 children (group 1), who were referred and treated in the early stages of progression, at a mean age of one year seven months (6 to 48 months) and with a mean Cobb angle of 32° (11° to 65°), the scoliosis resolved by a mean age of three years and six months. They needed no further treatment and went on to lead a normal life. At the last follow-up, their mean age was 11 years and two months (1 year 10 months to 25 years 2 months), 23 (24.5%) were at Risser stages 4 and 5 and 13 girls were post-menarchal.

In 42 children (group 2), who were referred late at a mean age of two years and six months (11 to 48 months) and with a mean Cobb angle of 52° (23° to 92°), treatment could only reduce but not reverse the deformity. At the last follow-up, at a mean age of ten years and four months (1 year 9 months to 22 years 1 month), eight children (19%) were at Risser stages 4 and 5 and five girls were post-menarchal. Fifteen children (35.7%) had undergone spinal fusion, as may all the rest eventually.


J. N. Awad K. M. Kebaish J. Donigan D. B. Cohen J. P. Kostuik
View article
Download PDF

In order to identify the risk factors and the incidence of post-operative spinal epidural haematoma, we analysed the records of 14 932 patients undergoing spinal surgery between 1984 and 2002. Of these, 32 (0.2%) required re-operation within one week of the initial procedure and had an International Classification of Diseases (ICD)-9 code for haematoma complicating a procedure (998.12). As controls, we selected those who had undergone a procedure of equal complexity by the same surgeon but who had not developed this complication. Risks identified before operation were older than 60 years of age, the use of pre-operative non-steroidal anti-inflammatories and Rh-positive blood type. Those during the procedure were involvement of more than five operative levels, a haemoglobin < 10 g/dL, and blood loss > 1 L, and after operation an international normalised ratio > 2.0 within the first 48 hours. All these were identified as significant (p < 0.03). Well-controlled anticoagulation and the use of drains were not associated with an increased risk of post-operative spinal epidural haematoma.


A. Alam K. Willett S. Ostlere
View article
Download PDF

Incomplete intertrochanteric fractures do not extend across to the medial femoral cortex and are stable, without rotational deformity or shortening of the lower limb. The aim of our study was to establish whether they can be successfully managed conservatively. A total of 68 patients over a five-year period presented with a suspected fracture of the femoral neck and underwent an MRI scan for further assessment. From these, we retrospectively reviewed eight patients with normal plain radiographs but with an incomplete, intertrochanteric fracture on MRI scan. Five were managed conservatively and three operatively.

The mean length of hospital stay was 16 days for the conservatively-treated group and 15 days for those who underwent surgery; this was not statistically significant (p > 0.5) and all patients were mobilised on discharge. Although five patients were readmitted at a mean of 3.2 years after discharge, none had progressed to a complete fracture. We believe that patients with incomplete intertrochanteric fractures should be considered for conservative treatment.


M. Al-Maiyah D. Hill A. Bajwa S. Slater P. Patil A. Port P. J. Gregg
View article
Download PDF

We have investigated the contaminating bacteria in primary hip arthroplasty and their sensitivity to the prophylactic antibiotics currently in use. Impressions (627) of the gloved hands of the surgical team in 50 total hip arthroplasties were obtained on blood agar. The gloves were changed after draping, at intervals of 20 minutes thereafter, and before using cement. Changes were also undertaken whenever a visible puncture was detected. The culture plates were incubated at 37°C for 48 hours. Isolates were identified and tested for sensitivity to flucloxacillin, which is a recognised indicator of sensitivity to cefuroxime. They were also tested against other agents depending upon their appearance on Gram staining.

We found contamination in 57 (9%) impressions and 106 bacterial isolates. Coagulase-negative staphylococci were seen most frequently (68.9%), but we also isolated Micrococcus (12.3%), diphtheroids (9.4%), Staphylococcus aureus (6.6%) and Escherichia coli (0.9%). Of the coagulase-negative staphylococci, only 52.1% were sensitive to flucloxacillin and therefore to cefuroxime. We believe that it is now appropriate to review the relevance of prophylaxis with cefuroxime and to consider the use of other agents.


C. W. B. Steinlechner N. C. Mkandawire
View article
Download PDF

The management of chronic osteomyelitis requires the excision of necrotic and infected material followed by the prolonged administration of antibiotics. Sequestrectomy may be required before an involucrum has formed, resulting in a longitudinal bone defect. This can be difficult to fill. Vascularised grafts are complicated by a high rate of recurrent infection and thrombosis.

We have managed defects of long bones in children after sequestrectomy by the use of non-vascularised fibular grafts harvested subperiosteally and held by an intramedullary Kirschner wire. Eight children underwent this procedure. In six the tibia was involved and in one each the humerus and radius. One patient was lost to follow-up. Six grafts united at both ends within 12 weeks. The seventh developed an infected nonunion distally which united after further debridement. One patient required a further sequestrectomy which did not compromise union.

We have found this to be a straightforward technique with reliable results and were able to salvage the limb in all the seven patients who were reviewed.


R. W. Paton K. Hinduja C. D. Thomas
View article
Download PDF

Of the 34 723 infants born between 1 June 1992 and 31 May 2002, the hips of 2578 with clinical instability or at-risk factors for developmental dysplasia of the hip were imaged by ultrasound.

Instability of the hip was present in 77 patients, of whom only 24 (31.2%) had an associated risk factor. From the ‘at-risk’ groups, the overall risk of type-III dysplasia, instability and irreducibility was 1:15 when family history, 1:27 when breech delivery and 1:33 when foot deformity were considered as risk factors. Of those hips which were ultrasonographically stable, 88 had type-III dysplasia.

A national programme of selective ultrasound screening of at-risk factors for the diagnosis of hip dislocation or instability alone cannot be recommended because of its low predictive value (1:88). However, the incidence of type-III dysplasia and hip dislocation or dislocatability in the groups with clinical instability, family history, breech position and possibly postural foot deformity as risk factors could justify a programme of selective ultrasound imaging.


General Orthopaedics
Access Required
M. K. Allami W. Jamil B. Fourie V. Ashton P. J. Gregg
View article
Download PDF

The Department of Health and the Public Health Laboratory Service established the Nosocomial Infection National Surveillance Scheme in order to standardise the collection of information about infections acquired in hospital in the United Kingdom and provide national data with which hospitals could measure their own performance. The definition of superficial incisional infection (skin and subcutaneous tissue), set by the Center for Disease Control (CDC), should meet at least one of the defined criteria which would confirm the diagnosis and determine the need for specific treatment.

We have assessed the interobserver reliability of the criteria for superficial incisional infection set by the CDC in our current practice. The incisional site of 50 patients who had an elective primary arthroplasty of the hip or knee was evaluated independently by two orthopaedic clinical research fellows and two orthopaedic ward sisters for the presence or absence of surgical-site infection. Interobserver reliability was assessed by comparison of the criteria for wound infection used by the four observers using kappa reliability coefficients. Our study demonstrated that some of the components of the current CDC criteria were unreliable and we recommend their revision.


Access Required
M. A. El Masry A. Saha S. J. Calder
View article
Download PDF

Transient osteoporosis is an uncommon, self-limiting, reversible condition. We report a case involving the knee following trauma. The aetiology is unknown, but the association between transient osteoporosis and trauma has not been documented previously. The clinical presentation represents a degree of overlap among various clinical syndromes, including reflex sympathetic dystrophy and avascular necrosis. The diagnosis was confirmed by bone scan and MRI. The patient, a 47-year-old man, was treated with non-steroidal anti-inflammatory medication, protected weight-bearing and physiotherapy. He made a full clinical recovery and bone quality returned to virtual normality.


N. J. Coupe S. N. Patel S. McVerry C. H. Wynn-Jones
View article
Download PDF

We report a case of fatal haemorrhage following a low-energy fracture of the pubic ramus in an 85-year-old woman.


T. Irie T. Aizawa S. Kokubun
View article
Download PDF

Sex hormones play important roles in the regulation of the proliferation, maturation and death of chondrocytes in the epiphyseal growth plate. We have investigated the effects of male castration on the cell kinetics of chondrocytes as defined by the numbers of proliferating and dying cells. The growth plates of normal rabbits and animals castrated at eight weeks of age were obtained at 10, 15, 20 and 25 weeks of age.

Our study suggested that castration led to an increase in apoptosis and a decrease in the proliferation of chondrocytes in the growth plate. In addition, the number of chondrocytes in the castrated rabbits was less than that of normal animals of the same age.


R. A. Whiteside R. P. Jakob U. P. Wyss P. Mainil-Varlet
View article
Download PDF

Surgical reconstruction of articular surfaces by transplantation of osteochondral autografts has shown considerable promise in the treatment of focal articular lesions. During mosaicplasty, each cylindrical osteochondral graft is centred over the recipient hole and delivered by impacting the articular surface. Impact loading of articular cartilage has been associated with structural damage, loss of the viability of chondrocytes and subsequent degeneration of the articular cartilage. We have examined the relationship between single-impact loading and chondrocyte death for the specific confined-compression boundary conditions of mosaicplasty and the effect of repetitive impact loading which occurs during implantation of the graft on the resulting viability of the chondrocytes.

Fresh bovine and porcine femoral condyles were used in this experiment. The percentage of chondrocyte death was found to vary logarithmically with single-impact energy and was predicted more strongly by the mean force of the impact rather than by the number of impacts required during placement of the graft. The significance of these results in regard to the surgical technique and design features of instruments for osteochondral transplantation is discussed.


S. A. Lietman N. Inoue B. Rafiee L. W. Deitz E. Y. S. Chao
View article
Download PDF

We used a canine intercalary bone defect model to determine the effects of recombinant human osteogenic protein 1 (rhOP-1) on allograft incorporation. The allograft was treated with an implant made up of rhOP-1 and type I collagen or with type I collagen alone.

Radiographic analysis showed an increased volume of periosteal callus in both test groups compared with the control group at weeks 4, 6, 8 and 10. Mechanical testing after 12 weeks revealed increased maximal torque and stiffness in the rhOP-1 treated groups compared with the control group.

These results indicate a benefit from the use of an rhOP-1 implant in the healing of bone allografts. The effect was independent of the position of the implant. There may be a beneficial clinical application for this treatment.


K. Iesaka W. L. Jaffe C. M. Jones F. J. Kummer
View article
Download PDF

We have investigated the role of the penetration of saline on the shear strength of the cement-stem interface for stems inserted at room temperature and those preheated to 37°C using a variety of commercial bone cements. Immersion in saline for two weeks at 37°C reduced interfacial strength by 56% to 88% after insertion at room temperature and by 28% to 49% after preheating of the stem. The reduction in porosity as a result of preheating ranged from 71% to 100%. Increased porosity correlated with a reduction in shear strength after immersion in saline (r = 0.839, p < 0.01) indicating that interfacial porosity may act as a fluid conduit.


Access Required
J. F. Kragh S. J. Svoboda J. C. Wenke J. A. Ward T. J. Walters
View article
Download PDF

Our aim was to compare the biomechanical properties of suturing methods to determine a better method for the repair of lacerated skeletal muscle.

We tested Kessler stitches and the combination of Mason-Allen and perimeter stitches. Individual stitches were placed in the muscle belly of quadriceps femoris from a pig cadaver and were tensioned mechanically. The maximum loads and strains were measured and failure modes recorded. The mean load and strain for the Kessler stitches were significantly less than those for combination stitches. All five Kessler stitches tore out longitudinally from the muscle. All five combination stitches did not fail but successfully elongated.

Our study has shown that the better method of repair for suturing muscle is the use of combination stitches.


Author’s reply Pages 1306 - 1307
Access Required
M. ESHETE
View article
Download PDF

Access Required
A. AGARWAL R. AGARWAL
View article
Download PDF

M. H. M. HARRISON
View article
Download PDF

W. Y. KIM
View article
Download PDF

Author’s reply Pages 1307 - 1307
Access Required
G. C. BANNISTER A. KONYVES
View article
Download PDF

I. GAVRANKAPETANOVIC Z. VUKASINOVIC
View article
Download PDF