Receive monthly Table of Contents alerts from The Bone & Joint Journal
Comprehensive article alerts can be set up and managed through your account settings
View my account settings
The two main categories of tendo Achillis tendon disorder are broadly classified by anatomical location to include non-insertional and insertional conditions. Non-insertional Achilles tendinopathy is often managed conservatively, and many rehabilitation protocols have been adapted and modified, with excellent clinical results. Emerging and popular alternative therapies, including a variety of injections and extracorporeal shockwave therapy, are often combined with rehabilitation protocols. Surgical approaches have developed, with minimally invasive procedures proving popular. The management of insertional Achilles tendinopathy is improved by recognising coexisting pathologies around the insertion. Conservative rehabilitation protocols as used in non-insertional disorders are thought to prove less successful, but such methods are being modified, with improving results. Treatment such as shockwave therapy is also proving successful. Surgical approaches specific to the diagnosis are constantly evolving, and good results have been achieved.
Adolescent idiopathic scoliosis affects about
3% of children. Non-operative measures are aimed at altering the natural
history to maintain the size of the curve below 40° at skeletal
maturity. The application of braces to treat spinal deformity pre-dates
the era of evidence-based medicine, and there is a paucity of irrefutable
prospective evidence in the literature to support their use and
their effectiveness has been questioned. This review considers this evidence. The weight of the evidence
is in favour of bracing over observation. The most recent literature
has moved away from addressing this question, and instead focuses
on developments in the design of braces and ways to improve compliance. Cite this article:
Most posterior hindfoot procedures have been
described with the patient positioned prone. This affords excellent access
to posterior hindfoot structures but has several disadvantages for
the management of the airway, the requirement for an endotracheal
tube in all patients, difficulty with ventilation and an increased
risk of pressure injuries, especially with regard to reduced ocular
perfusion. We describe use of the ‘recovery position’, which affords equivalent
access to the posterior aspect of the ankle and hindfoot without
the morbidity associated with the prone position. A laryngeal mask
rather than endotracheal tube may be used in most patients. In this
annotation we describe this technique, which offers a safe and simple alternative
method of positioning patients for posterior hindfoot and ankle
surgery. Cite this article:
We investigated differences in the location and
mode of labral tears between dysplastic hips and hips with femoroacetabular
impingement (FAI). We also investigated the relationship between
labral tear and adjacent cartilage damage. We retrospectively studied
72 symptomatic hips (in 68 patients: 19 men and 49 women) with radiological
evidence of dysplasia or FAI on high-resolution CT arthrography.
The incidence and location of labral tears and modes of tear associated
with the base of the labrum (Mode 1) or body of the labrum (Mode
2) were compared among FAI, mildly dysplastic and severely dysplastic
hips. The locations predominantly involved with labral tears were
different in FAI and mild dysplastic hips (anterior and anterosuperior
zones) and in severely dysplastic hips (anterosuperior and superior
zones) around the acetabulum. Significant differences were observed
in the prevalence of Mode 1 Hip pathology is significantly related to the locations and modes
of labral tears. Mode 1 tears may be a risk factor for the development
of adjacent acetabular cartilage damage. Cite this article:
Orientation of the acetabular component influences
wear, range of movement and the incidence of dislocation after total
hip replacement (THR). During surgery, such orientation is often
referenced to the anterior pelvic plane (APP), but APP inclination
relative to the coronal plane (pelvic tilt) varies substantially
between individuals. In contrast, the change in pelvic tilt from
supine to standing (dPT) is small for nearly all individuals. Therefore,
in THR performed with the patient supine and the patient’s coronal
plane parallel to the operating table, we propose that freehand placement
of the acetabular component placement is reliable and reflects standing
(functional) cup position. We examined this hypothesis in 56 hips
in 56 patients (19 men) with a mean age of 61 years (29 to 80) using
three-dimensional CT pelvic reconstructions and standing lateral
pelvic radiographs. We found a low variability of acetabular component
placement, with 46 implants (82%) placed within a combined range
of 30° to 50° inclination and 5° to 25° anteversion. Changing from
the supine to the standing position (analysed in 47 patients) was associated
with an anteversion change <
10° in 45 patients (96%). dPT was
<
10° in 41 patients (87%). In conclusion, supine THR appears
to provide reliable freehand acetabular component placement. In
most patients a small reclination of the pelvis going from supine
to standing causes a small increase in anteversion of the acetabular component Cite this article:
A retrospective study was conducted to investigate
the changes in metal ion levels in a consecutive series of Birmingham
Hip Resurfacings (BHRs) at a minimum ten-year follow-up. We reviewed
250 BHRs implanted in 232 patients between 1998 and 2001. Implant
survival, clinical outcome (Harris hip score), radiographs and serum chromium
(Cr) and cobalt (Co) ion levels were assessed. Of 232 patients, 18 were dead (five bilateral BHRs), 15 lost
to follow-up and ten had been revised. The remaining 202 BHRs in
190 patients (136 men and 54 women; mean age at surgery 50.5 years
(17 to 76)) were evaluated at a minimum follow-up of ten years (mean
10.8 years (10 to 13.6)). The overall implant survival at 13.2 years
was 92.4% (95% confidence interval 90.8 to 94.0). The mean Harris
hip score was 97.7 (median 100; 65 to 100). Median and mean ion
levels were low for unilateral resurfacings (Cr: median 1.3 µg/l,
mean
1.95 µg/l (<
0.5 to 16.2); Co: median 1.0 µg/l, mean 1.62 µg/l
(<
0.5 to 17.3)) and bilateral resurfacings (Cr: median 3.2 µg/l,
mean 3.46 µg/l (<
0.5 to 10.0); Co: median 2.3 µg/l, mean 2.66
µg/l (<
0.5 to 9.5)). In 80 unilateral BHRs with sequential ion
measurements, Cr and Co levels were found to decrease significantly
(p <
0.001) from the initial assessment at a median of six years
(4 to 8) to the last assessment at a median of 11 years (9 to 13),
with a mean reduction of 1.24 µg/l for Cr and 0.88 µg/l for Co.
Three female patients had a >
2.5 µg/l increase of Co ions, associated with
head sizes ≤ 50 mm, clinical symptoms and osteolysis. Overall, there
was no significant difference in change of ion levels between genders
(Cr, p = 0.845; Co, p = 0.310) or component sizes (Cr, p = 0.505;
Co, p = 0.370). Higher acetabular component inclination angles correlated
with greater change in ion levels (Cr, p = 0.013; Co, p = 0.002).
Patients with increased ion levels had lower Harris hip scores (p
= 0.038). In conclusion, in well-functioning BHRs the metal ion levels
decreased significantly at ten years. An increase >
2.5 µg/l was
associated with poor function. Cite this article:
As many as 25% to 40% of unicompartmental knee
replacement (UKR) revisions are performed for pain, a possible cause
of which is proximal tibial strain. The aim of this study was to
examine the effect of UKR implant design and material on cortical
and cancellous proximal tibial strain in a synthetic bone model.
Composite Sawbone tibiae were implanted with cemented UKR components
of different designs, either all-polyethylene or metal-backed. The tibiae
were subsequently loaded in 500 N increments to 2500 N, unloading
between increments. Cortical surface strain was measured using a
digital image correlation technique. Cancellous damage was measured
using acoustic emission, an engineering technique that detects sonic
waves (‘hits’) produced when damage occurs in material. Anteromedial cortical surface strain showed significant differences
between implants at 1500 N and 2500 N in the proximal 10 mm only
(p <
0.001), with relative strain shielding in metal-backed implants.
Acoustic emission showed significant differences in cancellous bone
damage between implants at all loads (p = 0.001). All-polyethylene implants
displayed 16.6 times the total number of cumulative acoustic emission
hits as controls. All-polyethylene implants also displayed more
hits than controls at all loads (p <
0.001), more than metal-backed
implants at loads ≥ 1500 N (p <
0.001), and greater acoustic
emission activity on unloading than controls (p = 0.01), reflecting
a lack of implant stiffness. All-polyethylene implants were associated
with a significant increase in damage at the microscopic level compared
with metal-backed implants, even at low loads. All-polyethylene
implants should be used with caution in patients who are likely
to impose large loads across their knee joint. Cite this article:
The outcome of high tibial osteotomy (HTO) deteriorates
with time, and additional procedures may be required. The aim of
this study was to compare the clinical and radiological outcomes
between unicompartmental knee replacement (UKR) and total knee replacement
(TKR) after HTO as well as after primary UKR. A total of 63 patients (63
knees) were studied retrospectively and divided into three groups:
UKR after HTO (group A; n = 22), TKR after HTO (group B; n = 18)
and primary UKR (group C; n = 22). The Oxford knee score (OKS),
Knee Society score (KSS), hip–knee–ankle angles, mechanical axis
and patellar height were evaluated pre- and post-operatively. At
a mean of 64 months (19 to 180) post-operatively the mean OKS was
43.8 (33 to 49), 43.3 (30 to 48) and 42.5 (29 to 48) for groups
A, B and C, respectively (p = 0.73). The mean KSS knee score was
88.8 (54 to 100), 88.11 (51 to 100) and 85.3 (45 to 100) for groups
A, B and C, respectively (p = 0.65), and the mean KSS function score
was 85.0 (50 to 100) in group A, 85.8 (20 to 100) in group B and
79.3 (50 to 100) in group C (p = 0.48). Radiologically the results
were comparable for all groups except for patellar height, with
a higher incidence of patella infra following a previous HTO (p
= 0.02). Cite this article:
The optimal management of the tibial slope in
achieving a high flexion angle in posterior-stabilised (PS) total
knee replacement (TKR) is not well understood, and most studies
evaluating the posterior tibial slope have been conducted on cruciate-retaining
TKRs. We analysed pre- and post-operative tibial slope differences,
pre- and post-operative coronal knee alignment and post-operative
maximum flexion angle in 167 patients undergoing 209 TKRs. The mean
pre-operative posterior tibial slope was 8.6° (1.3° to 17°) and
post-operatively it was 8.0° (0.1° to 16.7°). Multiple linear regression
analysis showed that the absolute difference between pre- and post-operative
tibial slope (p <
0.001), post-operative coronal alignment (p
= 0.02) and pre-operative range of movement (p <
0.001) predicted post-operative
flexion. The variance of change in tibial slope became larger as
the post-operative maximum flexion angle decreased. The odds ratio
of having a post-operative flexion angle <
100° was 17.6 if the
slope change was >
2°. Our data suggest that recreation of the anatomical
tibial slope appears to improve maximum flexion after posterior-stabilised
TKR, provided coronal alignment has been restored. Cite this article:
Pre-operative variables are increasingly being
used to determine eligibility for total knee replacement (TKR).
This study was undertaken to evaluate the relationships, interactions
and predictive capacity of variables available pre- and post-operatively
on patient satisfaction following TKR. Using nationally collected
patient reported outcome measures and data from the National Joint
Registry for England and Wales, we identified
22 798 patients who underwent TKR for osteoarthritis between August
2008 and September 2010. The ability of specific covariates to predict
satisfaction was assessed using ordinal logistic regression and
structural equational modelling. Only 4959 (22%) of 22 278 patients
rated the results of their TKR as ‘excellent’, despite the majority
(71%, n = 15 882) perceiving their knee symptoms to be much improved.
The strongest predictors of satisfaction were post-operative variables.
Satisfaction was significantly and positively related to the perception
of symptom improvement (operative success) and the post-operative
EuroQol-5D score. While also significant within the models pre-operative
variables were less important and had a minimal influence upon post-operative
satisfaction. The most robust predictions of satisfaction occurred
only when both pre- and post-operative variables were considered
together. These findings question the appropriateness of restricting
access to care based on arbitrary pre-operative thresholds as these
factors have little bearing on post-operative satisfaction. Cite this article:
We performed a retrospective review of a consecutive
series of 178 Mobility total ankle replacements (TARs) performed
by three surgeons between January 2004 and June 2009, and analysed
radiological parameters and clinical outcomes in a subgroup of 129
patients. The mean follow-up was 4 years (2 to 6.3). A total of
ten revision procedures (5.6%) were undertaken. The mean Ankle Osteoarthritis
Scale (AOS) pain score was 17 (0 to 88) and 86% of patients were
clinically improved at follow-up. However, 18 patients (18 TARs,
14%) had a poor outcome with an AOS pain score of >
30. A worse
outcome was associated with a pre-operative diagnosis of post-traumatic degenerative
arthritis. However, no pre- or post-operative radiological parameters
were significantly associated with a poor outcome. Of the patients
with persistent pain, eight had predominantly medial-sided pain.
Thirty TARs (29%) had a radiolucency in at least one zone. The outcome of the Mobility TAR at a mean of four years is satisfactory
in >
85% of patients. However, there is a significant incidence
of persistent pain, particularly on the medial side, for which we
were unable to establish a cause. Cite this article:
The aims of this study were to assess the efficacy
of a newly designed radiological technique (the radial groove view)
for the detection of protrusion of screws in the groove for the
extensor pollicis longus tendon (EPL) during plating of distal radial
fractures. We also aimed to determine the optimum position of the
forearm to obtain this view. We initially analysed the anatomy of
the EPL groove by performing three-dimensional CT on 51 normal forearms.
The mean horizontal angle of the groove was 17.8° (14° to 23°).
We found that the ideal position of the fluoroscopic beam to obtain
this view was 20° in the horizontal plane and 5° in the sagittal
plane. We then intra-operatively assessed the use of the radial groove
view for detecting protrusion of screws in the EPL groove in 93
fractures that were treated by volar plating. A total of 13 protruding
screws were detected. They were changed to shorter screws and these
patients underwent CT scans of the wrist immediately post-operatively.
There remained one screw that was protruding. These findings suggest
that the use of the radial groove view intra-operatively is a good
method of assessing the possible protrusion of screws into the groove
of EPL when plating a fracture of the distal radius. Cite this article:
Osteoarthritis results in changes in the dimensions
of the glenoid. This study aimed to assess the size and radius of curvature
of arthritic glenoids. A total of 145 CT scans were analysed, performed
as part of routine pre-operative assessment before total shoulder
replacement in 91 women and 54 men. Only patients with primary osteoarthritis and
a concentric glenoid were included in the study. The CT scans underwent
three-dimensional (3D) reconstruction and were analysed using dedicated
computer software. The measurements consisted of maximum superoinferior height,
anteroposterior width and a best-fit sphere radius of curvature
of the glenoid. The mean height was 40.2 mm ( With current shoulder replacement systems using a unique backside
radius of curvature for the glenoid component, there is a risk of
undertaking excessive reaming to adapt the bone to the component
resulting in sacrifice of subchondral bone or under-reaming and
instability of the component due to a ’rocking horse‘ phenomenon. Cite this article:
We measured the tension in the interosseous membrane
in six cadaveric forearms using an Cite this article:
There have been a few reports of patients with
a combination of lumbar and thoracic spinal stenosis. We describe six
patients who suffered unexpected acute neurological deterioration
at a mean of 7.8 days (6 to 10) after lumbar decompressive surgery.
Five had progressive weakness and one had recurrent pain in the
lower limbs. There was incomplete recovery following subsequent
thoracic decompressive surgery. The neurological presentation can be confusing. Patients with
compressive myelopathy due to lower thoracic lesions, especially
epiconus lesions (T10 to T12/L1 disc level), present with similar
symptoms to those with lumbar radiculopathy or cauda equina lesions.
Despite the rarity of this condition we advise that patients who
undergo lumbar decompressive surgery for stenosis should have sagittal
whole spine MRI studies pre-operatively to exclude proximal neurological
compression. Cite this article:
The main form of treatment of a chordoma of the
mobile spine is total We report two patients who underwent TES after CIRT for treating
a chordoma in the lumbar spine with good medium-term outcomes. At
operation, there remained histological evidence of viable tumour
cells in both cases. After the combination use of TES following
CIRT, neither patient showed signs of recurrence at the follow-up examination.
These two cases suggest that CIRT should be combined with total
spondylectomy in the treatment of chordoma of the mobile spine. Cite this article:
We describe the routine imaging practices of
Level 1 trauma centres for patients with severe pelvic ring fractures, and
the interobserver reliability of the classification systems of these
fractures using plain radiographs and three-dimensional (3D) CT
reconstructions. Clinical and imaging data for 187 adult patients
(139 men and 48 women, mean age 43 years (15 to 101)) with a severe
pelvic ring fracture managed at two Level 1 trauma centres between July
2007 and June 2010 were extracted. Three experienced orthopaedic
surgeons classified the plain radiographs and 3D CT reconstruction
images of 100 patients using the Tile/AO and Young–Burgess systems.
Reliability was compared using kappa statistics. A total of
115 patients (62%) had plain radiographs as well as two-dimensional
(2D) CT and 3D CT reconstructions, 52 patients (28%) had plain films
only, 12 (6.4%) had 2D and 3D CT reconstructions images only, and
eight patients (4.3%) had no available images. The plain radiograph
was limited to an anteroposterior pelvic view. Patients without
imaging, or only plain films, were more severely injured. A total
of 72 patients (39%) were imaged with a pelvic binder Interobserver reliability for the Tile/AO (Kappa 0.10 to 0.17)
and Young–Burgess (Kappa 0.09 to 0.21) was low, and insufficient
for clinical and research purposes. Severe pelvic ring fractures are difficult to classify due to
their complexity, the increasing use of early treatment such as
with pelvic binders, and the absence of imaging altogether in important
patient sub-groups, such as those who die early of their injuries. Cite this article:
A consecutive series of 320 patients with an
intracapsular fracture of the hip treated with a dynamic locking
plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients
were followed for a minimum of two years. During the follow-up period
109 patients died. There were 112 undisplaced fractures, of which three (2.7%) developed
nonunion or re-displacement and five (4.5%) developed avascular
necrosis of the femoral head. Revision to an arthroplasty was required
for five patients (4.5%). A further six patients (5.4%) had elective
removal of the plate and screws. There were 208 displaced fractures, of which 32 (15.4%) developed
nonunion or re-displacement and 23 (11.1%) developed avascular necrosis.
A further four patients (1.9%) developed a secondary fracture around
the TFN. Revision to a hip replacement was required for 43 patients
(20.7%) patients and a further seven (3.3%) had elective removal
of the plate and screws. It is suggested that the stronger distal fixation combined with
rotational stability may lead to a reduced incidence of complications
related to the healing of the fracture when compared with other
contemporary fixation devices but this needs to be confirmed in
further studies. Cite this article:
The augmentation of fixation with bone cement
is increasingly being used in the treatment of severe osteoporotic fractures.
We investigated the influence of bone quality on the mechanics of
augmentation of plate fixation in a distal femoral fracture model
(AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral
models were randomly assigned to either an augmented or a non-augmented
group. Fixation was performed using a locking compression plate.
In the augmented group additionally 1 ml of bone cement was injected
into the screw hole before insertion of the screw. Biomechanical
testing was performed in axial sinusoidal loading. Augmentation significantly
reduced the cut-out distance in the osteoporotic models by about
67% (non-augmented mean 0.30 mm ( Cite this article:
To date, all surgical techniques used for reconstruction
of the pelvic ring following supra-acetabular tumour resection produce
high complication rates. We evaluated the clinical, oncological
and functional outcomes of a cohort of 35 patients (15 men and 20
women), including 21 Ewing’s sarcomas, six chondrosarcomas, three sarcomas
not otherwise specified, one osteosarcoma, two osseous malignant
fibrous histiocytomas, one synovial cell sarcoma and one metastasis.
The mean age of the patients was 31 years (8 to 79) and the latest
follow-up was carried out at a mean of 46 months (1.9 to 139.5)
post-operatively. We undertook a functional reconstruction of the pelvic ring using
polyaxial screws and titanium rods. In 31 patients (89%) the construct
was encased in antibiotic-impregnated polymethylmethacrylate. Preservation
of the extremities was possible for all patients. The survival rate
at three years was 93.9% (95% confidence interval (CI) 77.9 to 98.4),
at five years it was 82.4% (95% CI 57.6 to 93.4). For the 21 patients
with Ewing’s sarcoma it was 95.2% (95% CI 70.7 to 99.3) and 81.5%
(95% CI 52.0 to 93.8), respectively. Wound healing problems were
observed in eight patients, deep infection in five and clinically
asymptomatic breakage of the screws in six. The five-year implant survival
was 93.3% (95% CI 57.8 to 95.7). Patients were mobilised at a mean
of 3.5 weeks (1 to 7) post-operatively. A post-operative neurological
defect occurred in 12 patients. The mean Musculoskeletal Tumor Society
score at last available follow-up was 21.2 (10 to 27). This reconstruction technique is characterised by simple and
oncologically appropriate applicability, achieving high primary
stability that allows early mobilisation, good functional results
and relatively low complication rates. Cite this article:
We hypothesised that the use of computer navigation-assisted
surgery for pelvic and sacral tumours would reduce the risk of an
intralesional margin. We reviewed 31 patients (18 men and 13 women)
with a mean age of 52.9 years (13.5 to 77.2) in whom computer navigation-assisted
surgery had been carried out for a bone tumour of the pelvis or
sacrum. There were 23 primary malignant bone tumours, four metastatic
tumours and four locally advanced primary tumours of the rectum.
The registration error when using computer navigation was <
1 mm
in each case. There were no complications related to the navigation,
which allowed the preservation of sacral nerve roots (n = 13), resection
of otherwise inoperable disease (n = 4) and the avoidance of hindquarter
amputation (n = 3). The intralesional resection rate for primary
tumours of the pelvis and sacrum was 8.7% (n = 2): clear bone resection
margins were achieved in all cases. At a mean follow-up of 13.1
months (3 to 34) three patients (13%) had developed a local recurrence.
The mean time alive from diagnosis was 16.8 months (4 to 48). Computer navigation-assisted surgery is safe and has reduced
our intralesional resection rate for primary tumours of the pelvis
and sacrum. We recommend this technique as being worthy of further
consideration for this group of patients. Cite this article:
We evaluated the clinical results and complications
after extra-articular resection of the distal femur and/or proximal
tibia and reconstruction with a tumour endoprosthesis (MUTARS) in
59 patients (mean age 33 years (11 to 74)) with malignant bone or
soft-tissue tumours. According to a Kaplan–Meier analysis, limb
survival was 76% (95% confidence interval (CI) 64.1 to 88.5) after
a mean follow-up of 4.7 years (one month to 17 years). Peri-prosthetic infection
was the most common indication for subsequent amputation (eight
patients). Survival of the prosthesis without revision was 48% (95%
CI 34.8 to 62.0) at two years and 25% (95% CI 11.1 to 39.9) at five years
post-operatively. Failure of the prosthesis was due to deep infection
in 22 patients (37%), aseptic loosening in ten patients (17%), and
peri-prosthetic fracture in six patients (10%). Wear of the bearings
made a minor revision necessary in 12 patients (20%). The mean Musculoskeletal
Tumor Society score was 23 (10 to 29). An extensor lag >
10° was
noted in ten patients (17%). These results suggest that limb salvage after extra-articular
resection with a tumour prosthesis can achieve good functional results
in most patients, although the rates of complications and subsequent
amputation are higher than in patients treated with intra-articular
resection. Cite this article:
We evaluated results at one year after surgical
correction of internal rotation deformities in the shoulders of
270 patients with obstetric brachial plexus palsy. The mean age
at surgery was 6.2 years (0.6 to 35). Two techniques were used:
open subscapularis elongation and latissimus dorsi to infraspinatus
transfer. In addition, open relocation was performed or attempted
in all patients with subluxed or dislocated joints. A mixed effects
model approach was used to evaluate the effects of surgery on internal
and external rotation, abduction, flexion and Mallet score. Independent
factors included operative status (pre- or post-operative), gender,
age, the condition of the joint, and whether or not transfer was
performed. The overall mean improvement in external rotation following
surgery was 84.6° (95% confidence interval (CI) 80.2 to 89.1) and
the mean Mallet score improved by 4.0 (95% CI 3.7 to 4.2). There was
a mean decrease in internal rotation of between 27.6° and 34.4°
in the relocated joint groups and 8.6° (95% CI 5.2 to 12.0) in the
normal joint group. Abduction and flexion were unchanged following
surgery. Adding a latissimus dorsi transfer did not result in greater
improvement in the mean external rotation compared with elongation
of the subscapularis alone. Cite this article:
The FRCS (Tr &
Orth) examination has three components: MCQs, Vivas and Clinical Examination. The Vivas are further divided into four sections comprising Basic Science, Adult Pathology, Hands and Children’s Orthopaedics and Trauma. The Clinical Examination section is divided into Upper and Lower limb cases. The aim of this section in the Journal is to focus specifically on the trainees preparing for the exam and to cater to all the sections of the exam. The vision is to complete the cycle of all relevant exam topics (as per the syllabus) in four years.